• 제목/요약/키워드: System Characteristic Constant

검색결과 268건 처리시간 0.033초

외란상쇄 관측기를 적용한 유도전동기 정속도 운전 (Driving Constant Speed of Induction Motor using Disturbance Cancellation Observer)

  • 김용주;서영수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.179-182
    • /
    • 2002
  • This Paper described a robust control of an induction motor using a disturbance cancellation observer of a feedforward control, The speed response of conventional Pl controller characteristic is affected by variations of load torque disturbance. Tn the proposed system, the speed control characteristic using a feedforward control isn't affected by a load torque disturbance.

  • PDF

계수의 특성비에 대한 선형계의 파라미터적 감도해석(II) : K-다항식의 경우 (The Parametric Sensitivity Analyses of linear System Relative to the Characteristic Ratios of Coefficient(II) : K-Polynomial Case)

  • 김영철;김근식
    • 제어로봇시스템학회논문지
    • /
    • 제10권4호
    • /
    • pp.295-303
    • /
    • 2004
  • Previously it has been shown that the all pole systems resulting good time responses can be characterized by so called K-polynomial. The polynomial is defined in terms of the principal characteristic ratio $\alpha_1$ and the generalized time constant $\tau$ . In this paper, Part II presents several sensitivity analyses of such systems with respect to $\alpha_1$ and $\tau$ changes. We first deal with the root sensitivity to the perturbation of $\alpha_1$ . By way of determining the unnormalized function sensitivity, both time response sensitivity and frequency response sensitivity are derived. Finally, the root sensitivity relative to $\tau$ change is also analyzed. These results provide some useful insight and background theory when we select of and l to compose a reference model of which denominator is a K-polynomial, which is illustrated by examples.

전자기 손실을 고려한 소형 외전형 영구자석 풍력발전기의 성능 평가 (2) - 전자기 손실 해석 및 성능 평가 - (Performance Evaluation of Small-Scaled Wind Power Generator with Outer Permanent Magnet Rotor considering Electromagnetic Losses (2) - Electromagnetic Losses and Performance Analysis -)

  • 고경진;장석명;최장영
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.50-62
    • /
    • 2011
  • In this paper, analytical techniques for performance characteristics analysis of wind power generator with outer permanent magnet rotor are proposed. Furthermore, the proposed analytical techniques are validated by performance experiments of the manufactured generator. In this part, characteristic equations of losses such as copper loss, core loss are derived. Using the derived loss characteristic equations, electrical parameters obtained in [15] and d-q axes method, constant load and constant speed characteristics of wind power generator are analyzed. And then, to analyze performance of wind power system according to wind speed, d-q analysis model considering wind turbine characteristics is proposed. Finally, the obtained performance characteristics results are validated in comparison with those by experiments.

수치 시뮬레이션을 이용한 수직밀폐형 지열시스템의 채열특성에 관한 연구 (Study on the characteristic of heat exchange for vertical geothermal system using the numerical simulation)

  • 남유진;오진환
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.66-72
    • /
    • 2014
  • Ground source heat pump system can achieve high efficiency of performance by utilizing annually constant underground temperature to provide heat source for space heating and cooling. Generally, the depth of constant-temperature zone under the ground depends on surface heat flux and soil properties. The deeper the ground heat exchanger is installed, the higher the heat exchange rate can be acquired. However, in order to optimally design the system, it is necessary to consider both the installation cost and the system performance. In this study, performance analysis of ground source heat pump system according to the depth has been conducted through the case study.

히트펌프 시스템의 시설원예 적용에 관한 실험적 연구 (An Experimental Study on Applying Heat Pump System to Facility Horticulture House)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.88-94
    • /
    • 2013
  • As the results of analysis that are applying a heat pump using underground water as heat source of facility horticulture house, temperature change in house, growth of cultivated plants and the crop characteristic, the conclusion can be acquired as follows. It was possible to maintain the chamber temperature through operating heat pump with setting goal temperature at $16^{\circ}C$ and temperature variation at ${\pm}3^{\circ}C$. And cooling and heating coefficient of performance in heat pump system are different from setting room temperature and operation condition of equipment, totally in case that the setting temperature in house is low, the coefficient of performance and the in case that temperature departure is low. In case that the house does not heated, the result of the growth characteristic of cucumber planted last 50days is that cucumber grown in house equipped with heat pump is the most favorable growth characteristic due to maintaining a constant room temperature. After 90 days, the quantity and weight cucumber harvested in each house are averagely 9.8%, 13.1% increase and more heavy weight respectively. So it is researched that crop characteristic is superior.

HID 램프용 퍼지제어 전자식 안정기 (Fuzzy logic Controlled Electronic Ballast for HID Lamps)

  • 김병철;차현록;김광현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권10호
    • /
    • pp.587-594
    • /
    • 2002
  • A low frequency square wave electronic ballast for the high intensity discharge(HID) lamps using fuzzy logic controller is developed. This electronic ballast consists a buck converter, a low frequency square wave full bridge inverter, a high voltage pulse generator for the HID lamp ignition, an over current protection circuit and an 8-bit microcontroller. The ballast system is operated on the constant current mode during the HID lamp start-up process and the system is operated on the constant power mode during steady state. Experimental results show that the fuzzy logic control operation is carried out successfully by the 8-bit microcontroller PIC16F877 In this electronic ballast system, in spite of the limited control bandwidth caused by low operating speed of the microcontroller, the good performance in the constant lamp current characteristic is obtained. Acoustic resonance of the HID lamps can be effectively avoided because the instantaneous In lamp power is fully constant due to the low frequency square wave drive.

제어알고리즘 개선을 위한 3차원 반송 시스템 선형유도전동기의 동특성 해석 (Dynamic Characteristics Analysis of 3D Conveyor System Linear Induction Motor for Control Algorithm Developments)

  • 전수진;이중호
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.514-518
    • /
    • 2007
  • It is necessary to modify the state-of-the-art of speed control theory because of the phase asymmetry in the Linear Induction Motor (LIM)and for the constant speed control of mover using single vector control inverter system, it is important that primary stack is located in appropriated intervals in the 3D conveyer system using LIM. The dynamic characteristic analysis method of the vector controlled LIM using coupled FEM and control algorithm taking into account the movement is proposed. The focus of this paper is the analysis relative to selecting primary stack intervals in order to constant speed control in the 3D conveyer system using LIM.

유한요소법을 이용한 자기부상용 선형유도기의 운전 특성 분석법 (Analysis on Driving Performance of Linear Induction Motor for Maglev System by Finite Element Method)

  • 김기찬
    • 한국산학기술학회논문지
    • /
    • 제15권7호
    • /
    • pp.4469-4474
    • /
    • 2014
  • 본 논문에서는 유한요소법을 사용하여 자기부상열차용 선형 유도 전동기의 효율적인 운전곡선 도출 방법을 제안한다. 긴 시간의 동특성 해석을 위해 선형유도기 모델을 선형에서 회전형 타입으로 변환하고, 제어시 필요한 슬립 파라미터를 전자장 해석을 통하여 효과적으로 도출하였다. 견인용 선형유도전동기는 인버터에 의해 저속의 정토크 영역에서는 전압/주파수 (V/f) 일정제어를 수행하고, 고속에서의 정출력 영역에서는 전압을 고정시키고 주파수를 증가시키면서 제어한다. 따라서 논문에서는 정토크 및 정출력 영역의 운전 특성을 도출하기 위해 각 구간에서 일정한 스텝으로 슬립특성 곡선을 도출하고, 차량의 운전 상태에 따른 슬립 및 주파수를 특성곡선의 보간법에 의해 결정한다. 본 방법을 이용하면 차량의 임의의 부하상태에 따라 최적의 운전 지령을 제시할 수 있다.

위치 추적기를 사용한 태양광 발전의 전력 변환시스템 특성에 관한 연구 (A Study on Characteristic of Power Conversion System of the Photovoltaic Using a Solar Position Tracker)

  • 황락훈;장진혁;나승권;김영수;안익수;조문택;송호빈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1034-1036
    • /
    • 2006
  • In this paper, I used microprocessor and sensor and designed to improve the efficiency of the photovoltaic system the photovoltaic position tracker device, and compared the normal photovoltaic system of fixed form with the photovoltaic system of solar position tracked form. Moreover, compared the catalogue of solar cell module and the simulation through a mathematics modelling with the solar cell's characteristic interpreting and, composed an power conversion system with boost converter and voltage source inverter. Used the constant voltage control method for maximum power point tracking in boost converter control and, used the SPWM(Sinusoidal Pulse Width Modulation) control method in inverter control.

  • PDF

Studies on Cure Behaviors, Dielectric Characteristics and Mechanical Properties of DGEBA/Poly(ethylene terephthalate) Blends

  • Park, Soo-Jin
    • Macromolecular Research
    • /
    • 제17권8호
    • /
    • pp.585-590
    • /
    • 2009
  • The cure behaviors, dielectric characteristics and fracture toughness of diglycidylether of bisphenol-A (DGEBA)/poly(ethylene terephthalate) (PET) blend system were investigated. The degree of conversion for the DGEBA/PET blend system was measured using Fourier transform infrared (FTIR) spectroscopy. The cure kinetics were investigated by measuring the cure activation energies ($E_a$) with dynamic differential scanning calorimetry (DSC). The dielectric characteristic was examined by dielectric analysis (DEA). The mechanical properties were investigated by measuring the critical stress intensity factor ($K_{IC}$), critical strain energy release rate ($G_{IC}$), and impact strength test. As a result, DGEBAIPET was successfully blended. The Ea of the blend system was increased with increasing PET content to a maximum at 10 phr PET. The dielectric constant was decreased with increasing PET content. The mechanical properties of the blend system were also superior to those of the neat DGEBA. These results were attributed to the increased cross-linking density of the blend system, resulting from the interaction between the epoxy group of DGEBA and the carboxyl group of PET.