• 제목/요약/키워드: System Capacity

검색결과 8,692건 처리시간 0.034초

실리카겔-물계 흡착식 냉동기에 관한 실험적 연구 (An Experimental Study of Adsorption Chiller using Silica gel-Water)

  • 권오경;윤재호;김종하
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1119-1124
    • /
    • 2006
  • The objectives of this paper are to investigate the performance of silica gel-water adsorption refrigeration system with heat recovery process from the system experiment. This system can be driven by waste heat at near ambient temperature from $60^{\circ}C$ to $90^{\circ}C$. The cooling capacity and coefficient of performance(COP) were measured from various experimental conditions. An experimental results revealed the influence of operating temperatures(hot, cooling and chilled water), water flow rates, and adsorption-desorption cycle times on cooling capacity and COP. Under the standard conditions of $80^{\circ}C$ hot water, $25^{\circ}C$ cooling water, $14^{\circ}C$ chilled water inlet temperatures and 420sec cycle time, a cooling capacity of 1.14kW and a COP for cooling of 0.55 can be achieved.

  • PDF

링크 레벨 시뮬레이션과 시스템 레벨 시뮬레이션에 의한 WCDMA TDD시스템과 cdma2000시스템 간의 상호간섭분석 (Interference Investigation between WCDMA TDD System and cdma2000 System by Link-level Simulation and System-level Simulation)

  • 차인석;장경희;김성진;최용석
    • 대한전자공학회논문지TC
    • /
    • 제41권7호
    • /
    • pp.21-30
    • /
    • 2004
  • WCDMA TDD 시스템의 Capacity는 주로 간섭에 의하여 제한되기 때문에, WCDMA TDD 시스템내의 간섭뿐만 아니라 인접 셀 간섭, 그리고 cdma2000 시스템과의 상호 간섭 효과를 최소화하여야 만이 WCDMA TDD 시스템의 기대용량을 얻을 수 있고, 현재 사용하고 있는 cdma2000 시스템과의 상호간섭을 최소화 할 수 있다. 본 논문에서는 3GPP TR 25.942 를 토대로 보다 정확한 파라미터를 사용하고, 시스템 레벨 시뮬레이션을 통해 WCDMA TDD 시스템과 cdma2000 시스템간의 상호간섭을 다양하고 실질적인 상황 하에서 해석하고, 또한 링크레벨을 고려한 시스템 레벨 시뮬레이션 결과로부터 두 시스템간의 상호간섭을 분석한다. 시뮬레이션 결과로부터 WCDMA TDD 시스템과 cdma2000 시스템 간 상호간섭을 고려한 시스템 용량의 최적화를 위한 조건을 제시한다.

열환경챔버의 냉방 시뮬레이션 프로그램 개발에 관한 연구 (A Study on the Development of Cooling Simulation Program for Thermal Environmental Chamber)

  • 이한홍
    • 한국생산제조학회지
    • /
    • 제8권5호
    • /
    • pp.108-114
    • /
    • 1999
  • The thermal environmental chamber has been using in maintaining weather condition keeping thermal capacity under heating and cooling load fluctuation and for the performance testing of cooling system or air-conditioner on artificial envi-ronment. In ordder to make the various environmental conditions in the thermal environmental chamber the proper cooling system is necessary to eliminate the heating load produced inside the chamber and to maintain the designed environmental condition. For this reason the optimal design of cooling system and the prediction of performance is also required. This paper describes the prediction of performance of cooling system in the thermal environmental chamber with the capacity of 37,000kcal/hr which is developed for the test of performance in heating mode of heat pump system, In the results this paper is trying to develop simulation program on the base of mathematical models and which can be applied effectively to the optimal design of cooling system and prediction of performance to the inside and outside change of envi-ronmetal load.

  • PDF

상재하중 하의 Soil Nailing System의 모형실험 (Model Tests of Soil Nailing System under Surcharges)

  • 유남재;유건선;김재일
    • 산업기술연구
    • /
    • 제14권
    • /
    • pp.77-87
    • /
    • 1994
  • This research is an experimental work of investigating the behavior of soil nailing system under surcharges whereas most of them were concentrated on evaluating its capacity under selfweight of excavated ground. Model tests in laboratory were performed to investigate the ultimate bearing capacity of soil nailing system under surcharges in forms of strip loading. Tests were carried out to find parameters controlling its capacity such as length of nail, vertical and horizontal spacings between nails, inclination of nail installation, and loading position of surcharges. Failure mechanism of forming failure line due to surcharge to soil nailing system was also observed by using dyed sand and monitoring its behavior. From results of these test, effects of parameters was analyzed qualitatively. Thus, this experimental results could provide meaningful data to analyze and design this system later.

  • PDF

System Capacity Analysis with the Retransmission Limit on ARQ in a Voice/Data DS-CDMA System

  • Lee, Chiho;Gwangzeen Ko;Kim, Kiseon
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -1
    • /
    • pp.513-516
    • /
    • 2000
  • In this paper, we investigate the effect of the retransmission limit both the system capacity and the average number of retransmissions in a voice/data DS-CDMA system. Basically, we consider the IS-95 type reverse link of the CDMA system, which supports two kinds of services: a general voice and a packetized data service. ARQ is used for the reliable data transmission. Convolutional code is used for FEC and CRC-CCITT code is used for the error detection in ARQ. The result shows that the number of concurrent data users decreases as we reduce the number of the retransmissions. However, at the same time, we can also reduce the average number of retransmissions. Concluding1y, we can select the retransmission limit so as to reduce large amount of' retransmissions with small sacrifice in the system capacity.

  • PDF

유압펌프용 SRM 구동 시스템의 특성해석 (Characteristics Analysis of SRM Drive System for Hydraulic Pump)

  • 이주현;김봉철;김태형;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.83-86
    • /
    • 2005
  • This paper proposed a hydraulic pump system which uses a variable SR drive and constant capacity pump. The base and maximum speed, torque are determined from displacement capacity of the pump and maximum pressure. The drive system is set to have a minimum power consumption having hydraulic preset pressure, which is operated within a maximum capacity and maximum preset pressure. This is achieved by controlling motor speed and power with feedback signal of pressure of the hydraulic pump. A 2.2kw, 12/8-pole SR motor and DSP based digital controller are designed and prototype drive system is manufactured. The proposed variable speed SR drive system is simulated and tested with experimental set-up. The test results show that the system has some good features such as high efficiency and high response characteristics.

  • PDF

CDMA2000시스템에서 전송률 제어에 기반한 호 수락제어 기법 (Rate Control Based Call Admission Control Scheme for CDMA2000 System)

  • 박형근
    • 한국통신학회논문지
    • /
    • 제29권9B호
    • /
    • pp.771-777
    • /
    • 2004
  • In a COMA system, the capacity is variable and mainly depends on multiple access interference. The multiple access interference has a deep relationship with transmitted or received power. The capacity of COMA2000 system is considered to be limited by the forward link capacity. In this paper, we show that the forward link cell load can be represented by the total transmitted power of base station and we propose a forward link call admission control (CAC) strategy for COMA2000 system. The proposed call admission scheme adopts the rate control algorithm for data call. This call admission scheme enables the system to utilize radio resource dynamically by controlling data rate according to the cell load status, and enhance the system throughput and grade of service (GoS). quality of service(QoS) such as blocking and outage probability.

TAC를 반영한 BIN 데이터 기반의 냉난방 부하 변화에 관한 연구 (Heating and Cooling Load Evaluation Study with TAC Based BIN Data)

  • 이광섭;김유진;민경천;이의준;강은철
    • 설비공학논문집
    • /
    • 제29권9호
    • /
    • pp.463-471
    • /
    • 2017
  • According to the Korea industrial standard of air conditioning systems (KS C 9306), cooling and heating loads for buildings can be calculated by using maximum and minimum temperature in BIN data. Cooling and heating loads can be determined by building set temperature and ambient temperature. Cooling and heating system capacity of buildings can be normally designed according to determined heating and cooling loads. Cooling and heating system capacity can be reduced by updated BIN data, applying TAC (Technical Advisory Committee) values. In this study, updated BIN data have been analyzed using ambient temperature of 19 areas in Korea for the last 10 years (2005~2014) provided by KMA (Korea Meteorological Administration). Building cooling and heating loads have been calculated following TAC based BIN data. As a result, designed system capacity decreased depending on applying TAC. Those were reduced as 7.1% ($100m^2$ building), 8.7% ($1,000m^2$ building) in cooling capacity, 11.7% in heating capacity when TAC 2.5% applied. And also, it is expected system initial and operating cost by decreasing system capacity.

대역확산 워터마킹 시스템의 채널용량 분석 (Analysis of Channel Capacity for Spread Spectrum Watermarking Systems)

  • 김주찬;배정남;김진영
    • 한국통신학회논문지
    • /
    • 제35권5C호
    • /
    • pp.439-444
    • /
    • 2010
  • 본 논문에서는 대역확산 워터마킹 시스템을 무선채널 환경에서 부가데이터를 전송하기 위하여 적용할 경우 채널에 의한 영향을 분석하기 위하여 채널용량식을 정보이론적 관점에서 유도하고 분석한다. 부가데이터를 기존의 무선통신 시스템을 통하여 전송하기 위해서는 무선채널을 통과하는 워터마킹 신호가 채널에 의해서 어떻게 영향을 받고, 어느 정도의 데이터를 신뢰할 만한 수준으로 전송가능한지를 판단하는 기준으로서의 채널용량에 관한 연구가 필수적이다. 수치적 결과로부터 대역확산 워터마킹 시스템의 채널용량은 HWR, WNR, PN 길이 및 호스트 시스템의 샘플링 주파수에 의해 결정됨을 알 수 있었다. 또한 적용된 Nakagami-m 페이딩 채널과 Log-normal 새도잉 채널에서 채널 상태 변화에 따른 채널용량의 변화를 확인하였고 다이버시티를 적용했을 경우의 채널용량의 향상 또한 확인하였다. 본 논문에서 다룬 대역확산 워터마킹 시스템의 채널용량의 수식적 결과는 PN 시퀀스를 이용하는 일반적인 대역확산 워터마킹 시스템에 적용할 수 있다.

MIMO 부분간섭 채널에서 멀티미디어 서비스를 위한 무선 네트워크의 성능 (Performance of Wireless Network for Multimedia Services in MIMO Partial Band Channel)

  • 노재성;조성준;김춘길
    • 디지털콘텐츠학회 논문지
    • /
    • 제6권3호
    • /
    • pp.137-142
    • /
    • 2005
  • CDMA 방식은 미래의 모바일 네트워크를 위한 다중접속 방식으로 많은 주목을 받고 있으며 높은 무선 용량과 유연한 데이터 전송에 대한장점을 가지고 있다. 그리고 CDMA방식은 실시간 음성 및 비실시간 데이터 서비스를 제공하는 차세대 멀티미디어 시스템 분야에서 ITU에 제안된 주요 기술이다. 본 논문에서는 무선 채널에서 다중 접속 간섭 및 부분 대역 간섭의 제거와 시스템 채널 용량의 증가를 위해 MIMO-MC/CDMA 시스템의 용량을 평가하였다. 최근에 스펙트럼 효율과 링크의 신뢰도를 증가하기 위하여 다중경로를 이용하는 MIMO 방식이 제안되고 있다. 특히, 본 논문에서는 MIMO-MC/CDMA시스템의 채널 용량을 Eb/No, Mc, p, B에 따라서 평가하였다. 얻어진 결과로부터 채널용량을 개선하기 위해서는 신호의 요소들은 서로 무상관이어야하며 만약 부적당한 공간에 의한 상관과 부분 대역 간섭에 의한 주파수 간섭이 발생하만 MIMO-MC/CDMA 시스템의 채널 용량은 상당히 감소하게 됨을 알 수 있었다.

  • PDF