• 제목/요약/키워드: System Capacity

검색결과 8,692건 처리시간 0.036초

DS-CDMA 셀룰라 시스템의 역방향 링크에서 소프트 핸드오프 영역비율의 효과 (Effects of soft handoff region ratio on the reverse link capacity of a DS-CDMA cellular system)

  • 전형구;권오준;강창언
    • 한국통신학회논문지
    • /
    • 제26권11B호
    • /
    • pp.1534-1539
    • /
    • 2001
  • In this paper, effects of soft handoff region on the reverse link capacity of a DS-CDMA cellular system are investigated. The reverse link capacity of a CDMA cellular system is calculated at a given soft handoff region ratio (SHRR) and path loss model. The results show that the reverse link capacity increases by 1 ∼ 4 channels according to the soft handoff region ratio and the path loss model. However, in the case of the path loss model having a large attenuation exponent ($\mu$ = 5) and a small shadowing standard deviation ( $\sigma$ = 6 dB), the reverse link capacity is no more increased by increasing SHRR.

  • PDF

다중경로 페이딩을 고려한 DS/CDMA 셀룰라 시스템의 얼랑용량 분석 (Erlang Capacity Analysis For DS/CDMA Cellular System Considering Multipath Fading)

  • 김항래;김남
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.126-129
    • /
    • 1999
  • In this paper, it is assumed that a mobile radio channel is a Rayleigh distributed multipath fading channel and Erlang capacity and equivalent channel numbers are calculated for the reverse link of a imperfect power controlled DS/CDMA cellular system considering both shadowing and multipath fading. The DS/CDMA blocking probability is calculated based on a new analysis method that considers Erlang capacity and ICF(interference correction factor) using the median value of $E_{b(i)}$/ $I_{o}$ corresponding to each reverse link user. It is showed that the effect of multipath fading must not be ignored in Erlang capacity of the IS-95 DS/CDMA cellular system and the Erlang capacity is decreased according to the increase of the deviation of the imperfect power control, to the decrease of the processing gain, to the increase of the voice activity.y.

  • PDF

디지탈 X-선 촬영 시스템의 정보용량 분석 (Analysis of the information capacity of digital radiograpy system)

  • 김종효;민병구;박광석;한만청
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.564-569
    • /
    • 1990
  • In this paper, the information capacity, the Integrate performance measure of digital radiography system has been quantitatively analyzed. The effect of various factors affecting the information capacity of the digital radiography system in multi-stage detection processes has been considered and analyzed In detail. The results show that the more Information capacity can be obtained with the smaller detector cell area, despite of the decreasing signal to noise ratio due to the reduced number of X-ray photons per detector cell. And also has been Indicated that the Increase of the information capacity may be severely lost by the addition of electric noise in final read-out stage.

  • PDF

전압안정도를 고려한 경제적인 발전가능전력의 산정알고리즘에 관한 연구 (A Study on Assesment Algorithm for the Economical Generation Capability considering Voltage Stability)

  • 문현호;이종주;윤창대;안비오;최상열;신명철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.536-543
    • /
    • 2006
  • This paper uses Monte Carlo technique, which is one of probabilistic methods of estimating the economical quantity of electric power generation in consideration of voltage stability in the aspect of power generation companies. In the power exchange system in Korea, when power generation companies participate in tenders for power generation capacity at the power exchange, they need to determine their power supply capacity considering the stability of electric power system. Thus, we purposed to propose an algorithm for estimating economical power generation capacity in theaspect of power generation companies, through which we can estimate the margin for voltage stability through P-V curve analysis by capacity according to the change of power generation capacity in a simulated system and to conduct Monte Carlo simulation in consideration of the margin

신 에너지전원설비의 배전계통 연계에 의한 단락용량 검토 (Impacts on short-circuit capacity by interconnection of new energy source generation into the distribution system)

  • 김응상;김슬기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.476-479
    • /
    • 2001
  • Interconnection of new energy sources, such as photovoltaic generation, wind power generation, etc., into the electric power distribution system may result in the increasing short-circuit capacity when a short circuit fault occurs. The short-circuit capacity becomes over the interrupting ratings of circuit breakers, and then they fails to operate in the proper way they prevent fault currents from flowing into the distribution facilities and thus causing them serious damages. This study deals with impacts on the respective short-circuit capacity of both low voltage and extra high voltage distribution systems at which new energy sources are installed. In order to obtain more accurate and all-case values very close to reality in the complicated distribution system, computer simulation tools should be required. In this paper, however, its focus is placed on examining the varying trend of short-circuit capacity, which may happen owing to new energy source interconnection, as a previewing step for exhaustive simulation studies.

  • PDF

주택면적의 변화에 따른 가정용 초소형 연료전지 코제너레이션 시스템의 경제성 분석에 관한 연구 (A Study on the Economic Evaluation with Super-Micro Fuel Cell Home Cogeneration System by Varying the Floor Area of House)

  • 노철우;김민수
    • 신재생에너지
    • /
    • 제4권2호
    • /
    • pp.45-51
    • /
    • 2008
  • The fuel cell system is environment-friendly and energy efficient system. Especially, the fuel cell cogeneration systems providing heat and electricity to buildings have been developed and applied to a lot of sites in the world to cope with the global warming and $CO_2$ emission problem. This paper presents the result of study on the economic evaluation with super-micro fuel cell (SMFC) cogeneration system by varying the floor area ($132m^2{\sim}331m^2$) of the house, whose system capacity ranges from 0.10 kWe to 0.50 kWe. The electricity demand, heat demand, saved energy cost, and the simple pay-back period have been simulated for the various capacities of fuel cell cogeneration system. As a result, this study suggests the fuel cell system’s capacity decision strategy for a given house area. Contrary to conventional design assumptions, the smaller capacity fuel cell cogeneration system is appropriate for the house of large floor area to defense the progressive electricity tax, and the larger capacity fuel cell cogeneration system is appropriate for the house of small floor area to sell the electricity.

  • PDF

주택면적의 변화에 따른 가정용 초소형 연료전지 코제너레이션 시스템의 경제성 분석에 관한 연구 (A Study on the Economic Evaluation with Super-Micro Fuel Cell Home Cogeneration System by Varying the Floor Area of House)

  • 노철우;김민수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.25-28
    • /
    • 2008
  • The fuel cell system is environment-friendly and energy efficient system. Especially, the fuel cell cogeneration systems providing heat and electricity to buildings have been developed and applied to a lot of sites in the world to cope with the global warming and $CO_2$ emission problem. This paper presents the result of study on the economic evaluation with super-micro fuel cell (SMFC) cogeneration system by varying the floor area ($132m^2{\sim}331m^2$) of the house, whose system capacity ranges from 0.10 kWe to 0.50 kWe. The electricity demand, heat demand, saved energy cost, and the simple pay-back period have been simulated for the various capacities of fuel cell cogeneration system. As a result, this study suggests the fuel cell system's capacity decision strategy for a given house area. Contrary to conventional design assumptions, the smaller capacity fuel cell cogeneration system is appropriate for the house of large floor area to defense the progressive electricity tax, and the larger capacity fuel cell cogeneration system is appropriate for the house of small floor area to sell the electricity.

  • PDF

태양광발전시스템의 장기운전에 의한 성능변화 분석 (Performance Analysis of long term operation for photovoltaic system)

  • 김의환;김정삼
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.110.1-110.1
    • /
    • 2011
  • This study analyzed the performance of long term operation photovoltaic system The 50 kWp grid connected photovoltaic system which was installed at KEPRI site in 1999 has been operated more than 12 years. In order to acquire long term operation characteristics of medium size photovoltaic system, the operation test data related on power generation electricity and capacity factor of 50 kWp system, which have been collected since 1999, were analysed. From the analysing results, 57.7 MWh in annual power generation electricity of 50 kWp photovoltaic system in 1999 has been decreased 49.1 MWh in 2005 and reached 38.0 MWh in 2010. In addition to, the capacity factor of 50 kWp photovoltaic system also showed 13.2 % in 1999, 11.2% in 2005 and finally reached 8.8% in 2011. The operation test data showed a trend of decreasing of generation electricity and capacity factor during the 12 years operation time and we guessed that was caused by solar cell performance degradation and decreasing of PCS system efficiency.

  • PDF

역방향 링크에 대한 디지털 셀룰러 CDMA 시스템의 용량 평가 (Capacity Evaluation of a Digital Cellular CDMA System for Reverse Link)

  • 박용서
    • 한국음향학회지
    • /
    • 제14권1호
    • /
    • pp.48-55
    • /
    • 1995
  • 서비스 영역이 중심 셀로부터 3개의 궤도가 포함하고 있는 37개의 6각형 셀의 역방향 링크(이동체-기지국)에 대한 디지털 셀룰러 CDMA의 용량을 컴퓨터 시뮬레이션에 의하여 구하였다. 채널에는 shadow페이딩이 존재하며, 시스템은 이상적으로 전력제어가 이루어지고 있다고 가정하였다. 본 논문에서는 전파손실계수와 음성통화율 그리고 인접 셀의 통화량을 고려한 CDMA 시스템의 용량 평가를 통하여 CDMA 시스템의 용량은 전과손실계수가 증가하고 음성통화율이 감소함에 따라 증가하며 $\gamma=4일$ 때 아날로그 셀룰러 FM/FDMA와 디지털 셀룰러 TDMA의 용량에 비하여 각각 15배와 5배 가량 크며 인접하고 있는 셀의 통화량에 매우 민감하다는 결과를 얻었다.

  • PDF

방송통신융합 시스템을 위한 채널용량 분석 (Capacity Analysis for Convergence System of Broadcasting and Telecommunication)

  • 김주찬;김은철;김진영
    • 대한전자공학회논문지TC
    • /
    • 제47권7호
    • /
    • pp.67-71
    • /
    • 2010
  • 본 고에서는 방송통신융합 시스템 설계에 필요한 채널용량 분석을 다룬다. 이를 위하여 상관도를 갖는 Hoyt 페이딩 채널에서 dual-branch MRC 기법을 적용한 방송통신 융합시스템의 채널용량을 수식적으로 근사화하여 유도하고 분석한다. 부가데이터를 전송하기 위해서는 잡음 환경에 강인한 대역확산 워터마킹 기법을 적용할 수 있다. 수식적 결과로부터 부가데이터 전송시스템의 채널용량은 다양한 시스템 변수와 채널 변수에 의해 결정될 수 있음을 확인한다.