• 제목/요약/키워드: Syringe

검색결과 360건 처리시간 0.029초

Analysis and Exposure Assessment of Perchlorate in Korean Dairy Products with LC-MS/MS

  • Oh, Sung-Hee;Lee, Ji-Woo;Mandy, Pawlas;Oh, Jeong-Eun
    • Environmental Analysis Health and Toxicology
    • /
    • 제26권
    • /
    • pp.12.1-12.7
    • /
    • 2011
  • Objectives: Perchlorate is an emerging contaminant that is found everywhere, including various foods. Perchlorate is known to disturb the production of thyroid hormones and leads to mental disorders in fetuses and infants, as well as metabolic problems in adults. In this study, we attempted to establish an LC-MS/MS method for measuring perchlorate in dairy products and used this developed method to investigate perchlorate levels in Korean milk and yogurt samples. Methods: The developed method of perchlorate analysis requires a shaker and 1% acetic acid/acetonitrile as the extracting solvent. Briefly, the samples were extracted and then centrifuged (4000 rpm, 1hour), and the supernatant was then passed through a $Envi^{TM}$ Carb SPE cartridge that had been prewashed sequentially with 6 mL of acetonitrile and 6 mL of 1% acetic acid in water. The final volume of the sample extract was adjusted to 40 mL with reagent water and the final sample was filtered through a 0.20-${\mu}m$ pore size PTFE (Polytetrafluoroethylene) syringe filter prior to LC-MS/MS. Results: The average levels of perchlorate in milk and yogurt samples were $5.63{\pm}3.49\;{\mu}g/L$ and $3.65{\pm}2.42\;{\mu}g/L$, respectively. The perchlorate levels observed in milk samples in this study were similar to those reported from China, Japan, and the United States. Conclusions: The exposure of Koreans to perchlorate through the consumption of dairy products was calculated based on the results of this study. For all age groups, the calculated exposure to perchlorate was below the reference of dose (0.7 ${\mu}g/kg$-day) proposed by the National Academy of Science, USA, but the perchlorate exposure of children was higher than that of adults. Therefore, further investigation of perchlorate in other food samples is needed to enable a more exact assessment of exposure of children to perchlorate.

Development of 68Ga-human serum albumin as a PET imaging agent for diagnosis of acute inflammation

  • Lee, Ji Youn;Kim, Hoyoung;Lee, Boeun;Kim, Young Ju;Lee, Yun-Sang;Jeong, Jae Min
    • 대한방사성의약품학회지
    • /
    • 제1권2호
    • /
    • pp.104-108
    • /
    • 2015
  • Human serum albumin (HSA) has potential for diagnosis and therapy in clinical setting. The purpose of experiments was to develop and evaluate $^{68}Ga$-HSA as a PET agent for diagnosis of acute inflammation. NOTA-HSA was synthesized by conjugating 2-(p-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid to HSA in 0.1 M sodium carbonate buffer (pH 9.5) and then purified using a PD-10 size-exclusion column. NOTA-HSA was labeled with $^{68}Ga$ at room temperature for 10 min, and 8.4% sodium hydrogen carbonate buffer was added for neutralization. $^{68}Ga$-NOTA-HSA was purified using alumina N plus light cartridge and $0.22{\mu}m$ syringe filter. Labeling efficiency and radiochemical purity were determined by ITLC-SG with 0.1 M citric acid. Biodistribution study was performed in a male BALB/c mice model of Carrageenan-induced acute inflammation. Animal PET study was performed in acute inflammation mice model after tail vein injection of $^{68}Ga$-HSA. This radiotracer showed high labeling efficiency (>99%) around pH 7. Biodistribution study showed higher inflamed footpad uptake than control footpad uptake. Animal PET study revealed 2 times higher uptake on inflamed footpad compared to control footpad. In these experiments, we developed $^{68}Ga$-HSA for acute inflammation PET imaging and evaluated it in a mouse disease model. The results demonstrated that $^{68}Ga$-HSA has potential as a PET imaging agent for diagnosis of acute inflammation.

A Simple, Rapid, and Automatic Centrifugal Microfluidic System for Influenza A H1N1 Viral RNA Purification

  • Park, Byung Hyun;Jung, Jae Hwan;Oh, Seung Jun;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.277.1-277.1
    • /
    • 2013
  • Molecular diagnostics consists of three processes, which are a sample pretreatment, a nucleic acid amplification, and an amplicon detection. Among three components, sample pretreatment is an important process in that it can increase the limit of detection by purifying nucleic acid in biological sample from contaminants that may interfere with the downstream genetic analysis such as nucleic acid amplification and detection. To achieve point-of-care virus detection system, the sample pretreatment process needs to be simple, rapid, and automatic. However, the commercial RNA extraction kits such as Rneasy (Qiagen) or MagnaPure (Roche) kit are highly labor-intensive and time-consuming due to numerous manual steps, and so it is not adequate for the on-site sample preparation. Herein, we have developed a rotary microfluidic system to extract and purify the RNA without necessity of external mechanical syringe pumps to allow flow control using microfluidic technology. We designed three reservoirs for sample, washing buffer, and elution buffer which were connected with different dimensional microfluidic channels. By controlling RPM, we could dispense a RNA sample solution, a washing buffer, and an elution buffer successively, so that the RNA was captured in the sol-gel solid phase, purified, and eluted in the downstream. Such a novel rotary sample preparation system eliminates some complicated hardwares and human intervention providing the opportunity to construct a fully integrated genetic analysis microsystem.

  • PDF

수종 근관 충전용 시멘트의 조직반응에 관한 조직학적 연구 (HISTOLOGIC STUDY OF THE TISSUE RESPONSE TO THREE ROOT CANAL CEMENTS)

  • 조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.677-687
    • /
    • 1996
  • This study was conducted to evaluate the tissue responses histologically to three root canal cements : Sealapex, AH-26, and zinc oxide-eugenol cement. Twelve white female Sprague-Dawley rats, weighing between 350 and 400 gm, were anesthetized with an intraperitoneal injection of Ketamine hydrochloride(0.4 ml). After shaving the sites selected(left and right scapular areas, left and right pelvic areas), the animal's backs were scrubed with soap and water, and sterilized with absolute alcohol. Each material was mixed to a thin consistency to flow out easily through a 24-guage needle, and loaded into a sterile, disposable plastic 1-ml syringe. All of the rats were injected subcutaneously with 0.1 ml of the three test sealers. Normal saline was used as a control. Animals were sacrificed after 48hr, 1, 4, and 12 weeks by overanesthetization using jars containing anesthetic ether. The tested sites were surgically removed with the surrounding tissue and fixed with 10% formalin. After 48 hours specimens were embedded in paraffin, sectioned to an average thickness of $6{\mu}m$ thick, stained with hematoxylin-eosin. The slides were examined under the light microscope. The results were obtained as follows 1. All material except the control showed various degree of inflammation on 48 hr. 2. Sealapex : In early stage, severe inflammatory cell infiltration was observed. At the 4th weeks observation, graunlomatous tissue with macrophage and foreing body giant cells containing many dark particles in their cytoplasm was observed. 3. AH-26 : Mild inflammatoy reaction was observed with AH-26 throughout the experimental period. 4. Zinc oxide-eugenol cement : Severe inflammatory cell infiltration, necrosis along the material, edema could be seen in early stage. Zinc oxide-eugenol cement maintained a moderate/severe reaction throughout the experimental period.

  • PDF

Multivariate analysis of the cleaning efficacy of different final irrigation techniques in the canal and isthmus of mandibular posterior teeth

  • Yoo, Yeon-Jee;Lee, WooCheol;Kim, Hyeon-Cheol;Shon, Won-Jun;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • 제38권3호
    • /
    • pp.154-159
    • /
    • 2013
  • Objectives: The aim of this study was to compare the cleaning efficacy of different final irrigation regimens in canal and isthmus of mandibular molars, and to evaluate the influence of related variables on cleaning efficacy of the irrigation systems. Materials and Methods: Mesial root canals from 60 mandibular molars were prepared and divided into 4 experimental groups according to the final irrigation technique: Group C, syringe irrigation; Group U, ultrasonics activation; Group SC, VPro StreamClean irrigation; Group EV, EndoVac irrigation. Cross-sections at 1, 3 and 5 mm levels from the apex were examined to calculate remaining debris area in the canal and isthmus spaces. Statistical analysis was completed by using Kruskal-Wallis test and Mann-Whitney U test for comparison among groups, and multivariate linear analysis to identify the significant variables (regular replenishment of irrigant, vapor lock management, and ultrasonic activation of irrigant) affecting the cleaning efficacy of the experimental groups. Results: Group SC and EV showed significantly higher canal cleanliness values than group C and U at 1 mm level (p < 0.05), and higher isthmus cleanliness values than group U at 3 mm and all levels of group C (p < 0.05). Multivariate linear regression analysis demonstrated that all variables had independent positive correlation at 1 mm level of canal and at all levels of isthmus with statistical significances. Conclusions: Both VPro StreamClean and EndoVac system showed favorable result as final irrigation regimens for cleaning debris in the complicated root canal system having curved canal and/or isthmus. The debridement of the isthmi significantly depends on the variables rather than the canals.

A Study of Electrospun PVDF on PET Sheet

  • Chanunpanich, Noppavan;Lee, Byung-Soo;Byun, Hong-Sik
    • Macromolecular Research
    • /
    • 제16권3호
    • /
    • pp.212-217
    • /
    • 2008
  • PVDF ($Kynar^{(R)}$ 761) nanofibers were made by electrospinning with an external voltage of 6-10 kV, a traveling distance of 7-15 cm and a flow rate of 0.4-1 mL/h. Although the mean diameter of the fibers has not changed significantly, the conditions affected the change in diameter distribution. This was attributed to interactions, both attraction and repulsion, between the positive charges on the polymer solutions and the electrically grounded collector. Higher voltages and traveling distance increased the level of attraction between the positive charge on the polymer solution and the electrically grounded collector, resulting in a narrow diameter distribution, In addition, a high flow rate allowed a high population of uniformly charged solutions to travel to the grounded collector, which resulted in a narrow diameter distribution. The optimum conditions for electrospinning of PVDF in DMAc/acetone (3/7 by wt) were a collector voltage of 6 kV, a syringe tip to collector of 7 cm, a flux rate of 0.4 mL/h and 10 kV, 10 cm, 1 mL/h, Since PVDF is widely used as a filtration membrane, it was electrospun on a PET support with a rotating drum as a grounded collector. Surprisingly, some straight nanofibers were separated from the randomly deposited nanofibers. The straight nanofiber area was transparent, while the randomly deposited nanofiber area was opaque. Both straight nanofibers and aligned nanotibers could be obtained by manipulating the PET drum collector. These phenomena were not observed when the support was changed to an Al sheet. This suggests that a pseudo dual collector was generated on the PET sheet. No negative charge was created because the PET sheet was not a conductive material. However, less charge was created when the sheet was not perfectly attached to the metal drum. Hence, the nanotibers jumped from one grounded site to the nearest one, yielding a straight nanofiber.

Comparison of anxiety and pain perceived with conventional and computerized local anesthesia delivery systems for different stages of anesthesia delivery in maxillary and mandibular nerve blocks

  • Aggarwal, Kamal;Lamba, Arundeep Kaur;Faraz, Farrukh;Tandon, Shruti;Makker, Kanika
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제18권6호
    • /
    • pp.367-373
    • /
    • 2018
  • Background: Fear of local anesthesia (LA) is a significant impediment to dental care as many patients delay or avoid treatment to avert pain. Computer-controlled local anesthetic delivery system (CCLAD), with constant and controlled rate of flow, present a painless alternative. The present study aimed to compare anxiety and pain perceived with conventional and computerized systems, for different stages of anesthesia delivery when administering various nerve blocks. Methods: One hundred patients requiring bilateral LA participated in the study. One side was anesthetized using one system and the contralateral side was anesthetized using the other, in two separate appointments. Patients assigned anxiety scores on a 5-point scale and used the visual analogue scale (VAS) for pain determination at needle insertion, during delivery of anesthetic solution, immediately after injection, and at the end of the periodontal procedure. Each patient's preference for the delivery system of future injections was also recorded. Results: Patients reported significantly lower anxiety levels with CCLAD compared to the syringe. Significantly lower mean VAS scores for anesthesia deposition, pain immediately after, and at the end of the periodontal procedure were also noted. However, pain at needle insertion was comparable between the two systems, with no statistical significance. Overall, 64.4% patients preferred CCLAD for future anesthesia. Conclusion: Lower pain perceived with CCLAD and higher preference for the system suggest that CCLAD should replace conventional syringes to allow pain-free dental treatment.

중심정맥관 삽입 시 발생하는 공기유입량의 예측: 실험연구 (Prediction of air inflow during central venous catheter insertion: experimental study)

  • 정효재;김양원;박창민;박철호;강지훈;윤유상
    • 대한응급의학회지
    • /
    • 제29권6호
    • /
    • pp.641-648
    • /
    • 2018
  • Objective: This study examined the incidence and amount of air inflow during central venous catheter (CVC) insertion. Methods: This study was an experimental study aimed at designing an apparatus to implement blood vessel and blood flow in the human body. A 1.5-m long core tube with a Teflon tube, suction rubber tube, and polyvinyl chloride tube were made. This core tube was assumed to be the blood vessel of the human body. Blood was replaced with a saline solution. The saline solution was placed higher than the core tube and flowed into the inside of the tube by gravity. The CVC was injected 15-cm deep into the core tube. The air was collected through a 3-way valve into the upper tube. The experiments were carried out by differentiating the pressure in the tube, CVC insertion step, and diameter of the end of the catheter. The experiment was repeated 10 times under the same conditions. Results: The amount of air decreased with increasing pressure applied to the tube. Air was not generated when the syringe needle was injected, and the amount of air increased with increasing size of the distal end catheter. Conclusion: To minimize the possibility of air embolism, it is necessary to close the distal end catheter at the earliest point as soon as possible.

Occupational Exposure during Intraperitoneal Pressurized Aerosol Chemotherapy Using Doxorubicin in a Pig Model

  • Wongeon Jung;Mijin Park;Soo Jin Park;Eun Ji Lee;Hee Seung Kim;Sun Ho Chung;Chungsik Yoon
    • Safety and Health at Work
    • /
    • 제14권2호
    • /
    • pp.237-242
    • /
    • 2023
  • Background: This study evaluated occupational exposure levels of doxorubicin in healthcare workers performing rotational intraperitoneal pressurized aerosol chemotherapy (PIPAC) procedures. Methods: All samples were collected during PIPAC procedures applying doxorubicin to an experimental animal model (pigs). All procedures were applied to seven pigs, each for approximately 44 min. Surface samples (n = 51) were obtained from substances contaminating the PIPAC devices, surrounding objects, and protective equipment. Airborne samples were also collected around the operating table (n = 39). All samples were analyzed using ultra-high performance liquid chromatography-mass spectrometry. Results: Among the surface samples, doxorubicin was detected in only five samples (9.8%) that were directly exposed to antineoplastic drug aerosols in the abdominal cavity originating from PIPAC devices. The telescopes showed concentrations of 0.48-5.44 ng/cm2 and the trocar showed 0.98 ng/cm2 in the region where the spraying nozzles were inserted. The syringe line connector showed a maximum concentration of 181.07 ng/cm2, following a leakage. Contamination was not detected on the surgeons' gloves or shoes. Objects surrounding the operating table, including tables, operating lights, entrance doors, and trocar holders, were found to be uncontaminated. All air samples collected at locations where healthcare workers performed procedures were found to be uncontaminated. Conclusions: Most air and surface samples were uncontaminated or showed very low doxorubicin concentrations during PIPAC procedures. However, there remains a potential for leakage, in which case dermal exposure may occur. Safety protocols related to leakage accidents, selection of appropriate protective equipment, and the use of disposable devices are necessary to prevent occupational exposure.

몰드변압기의 보이드 결함 크기 판별 (Identification of Void Diameters for Cast-Resin Transformers)

  • 정기우;김성욱
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.570-573
    • /
    • 2022
  • 본 논문에서는 신경망 모델을 적용한 몰드변압기의 보이드 결함 크기 판별에 관한 연구를 수행하였다. PCB 기반의 로고우스키 코일형 부분방전 센서를 제작하여 부분방전 신호를 측정하였고, 보이드에 의한 부분방전 결함을 모의하기 위한 PD 전극계를 제작하였다. 또한 보이드는 원통형 모양의 알루미늄 틀을 제작하여 에폭시가 경화되는 과정에서 실린지를 삽입하고 공기를 주입하여 서로다른 직경을 가지는 4개의 시편을 제작하였다. 보이드 결함 크기 판별을 위해 부분방전 전하량, 방전 펄스 수, 위상 분포의 부분방전 특성 파라미터를 추출하여 Labview 기반의 VI (Virtual Instrument)로 역전파 알고리즘을 설계하였다. 실험 결과로부터 제작된 알고리즘은 90%이상의 판별률로 결함의 직경크기를 구분할 수 있었다. 본 연구의 결과는 현장에서 PD 측정 시 몰드변압기의 유지보수 및 절연물 교체의 근거 자료로 활용될 수 있을 것으로 판단된다.

  • PDF