• 제목/요약/키워드: Syringe

검색결과 360건 처리시간 0.022초

치과위생사의 일회용 치과진료용품 감염관리 인지도와 재사용자율의 차이 (Differences in dental hygienists' infection control awareness and re-user rate of disposable dental care supplies)

  • 박보영;노희진
    • 한국치위생학회지
    • /
    • 제20권5호
    • /
    • pp.645-653
    • /
    • 2020
  • Objectives: The purpose of this study is to identify the difference between the awareness and reuser rate of infection control t for disposable dental care supplies (DDCS) according to general characteristics and infection management-related characteristics. Methods: A questionnaire was used for 277 dental hygienists to check the general characteristics, infection management-related characteristics, awareness of infection control disposable dental care products, syringe needle, prophylaxis cup, prophylaxis brush, plastic saliva ejector, orthodontic bracket, and gloves reuse rate. Results: The awareness of infection control for DDCS differed according to 'hospital type', 'average number of patients per day', 'presence or absence of infection control guidelines', and 'experience in infection management training in the last two years' (p<0.05). Reuser rates of disposable dental care products differed according to 'hospital type', 'average number of patients per day', 'presence or absence of infection control guidelines', and 'experience in infection management training in the last two years' (p<0.05). Conclusions: In order to manage infection of DDCS, the level of infection control system in the workplace is improved and support for related education is needed. In addition, guidelines and regulations on prohibition of reuse and classification criteria for various DDCS should be prepared.

흐름주입식 바이오센서용 기질용액 자동희석 장치 개발 (Development of an Auto Dilution Unit of Substrate Solutionfor a Flow Injection Type Biosensor)

  • 송대빈;정효석;정대홍;김성태
    • Journal of Biosystems Engineering
    • /
    • 제31권5호
    • /
    • pp.443-448
    • /
    • 2006
  • For development of an on-line monitoring unit of fermentation process, an auto dilution unit based on traditional chemical and biological analytical method was developed and the performance was evaluated. The dilution unit was constructed with two syringe pumps and flow direction change valves and fully automated. Total delivery volume of two pumps using distilled water was measured to confirm the operating stability And diluted concentrations of three substrate solutions (glucose, lactic acid, ethanol) were compared with a standard method with a high performance liquid chromatograph (glucose, lactic acid) and gas chromatograph (ethanol). Relative error values of total delivery volume of the pumps were below 3% and standard deviation values were 0.003 (n=5). Relative error values of diluted concentration of the dilution unit measurements were below 2% with 1/10 of dilution ratio and 70, $80{\mu}{\ell}$ of sample volume conditions for glucose and lactic acid, 1/30 of dilution ratio and $70{\mu}{\ell}$ of sample volume conditions for ethanol, respectively. In case of the ethanol, cause of the evaporative characteristics, the relative error values showed over 5% whole experimental conditions.

넙치(Paralichthys olivaceus) 근육 채취 방법에 따른 Kudoa septempunctata 진단 효율 비교 (Evaluation of a Non-destructive Diagnostic Test for Kudoa septempunctata in Farmed Olive Flounder Paralichthys olivaceus)

  • 송준영;정승희;최혜승
    • 한국수산과학회지
    • /
    • 제51권1호
    • /
    • pp.23-30
    • /
    • 2018
  • Kudoa septempunctata, a myxosporean parasite that infects olive flounder Paralichthys olivaceus is known to cause Kudoa food poisoning. Entire trunk muscle (ETM) is used for diagnosis of the parasite in fish and this method demands sacrifice of the host, causing a loss of commercial value. We developed a non-destructive method that uses a plastic syringe-style implanter to draw the sample, called the part-point muscle (PPM) sampling technique. We validated the PPM method in fish infected with K. septempunctata at the level detectable by the ETM method. We confirmed that the PPM method is equally sensitive in comparison to the ETM method for diagnosing K. septempunctata spores in olive flounder muscle. Our study also confirmed that the parasite is uniformly distributed in the dorsal muscle of infected fish. Over a period of 1 month, we observed no mortality of the host fish used for sampling by the PPM method. Thus, our studies demonstrate that the PPM sampling technique is an efficient, non-destructive method for diagnosing K. septempunctata in olive flounder.

Pseudomonas syringe pv. phaseolicola로 부터 제한효소의 분리정제 및 특성 (Purification and Characterzation of a Restriction Endonuclease from Pseudomonas syringae pv.phaselicola)

  • 배무;이은영
    • 한국미생물·생명공학회지
    • /
    • 제22권5호
    • /
    • pp.485-490
    • /
    • 1994
  • A restriction endonuclease, PsyI, has been isolated from Pseudomonas syringae pv. pha- seolicola, and its catalytic properties have been studied. This enzyme was purified through strepto- mycin sulfate and ammonium sulfate fractionation, phosphocellulose Pll, DEAE-cellulose, hydroxy- apatite and Sephadex G-100 column chromatography. It's molecular weight was about 50,000 dalton as determined by 7.5% polyacrylamide gel electrophoresis containing 0.1% SDS. In catalytic proper- ties, PsyI shows stable at wide ranges of pH between 7.0 and 10.0, of temperature between 30$\circ$C and 37$\circ$C, and its thermal stability is between 25$\circ$C, and 45$\circ$C, at the presence Of 10 mM MgCl$_{2}$-PsyI essentially require Na salt for enzyme reaction, is rather inhibited in the high Na salt concent- ration. The presence of 2-mercaptoethanol is absolutely required for the enzyme activity. This endonuclease, PsyI was determined to be an isoschizomer of SalI from the results of the restriction mapping and DNA sequencing.

  • PDF

만성 창상의 치료에서 이동식 음압요법의 신고안 (The Management of Chronic Wound with Modified Portable Negative Pressure Therapy)

  • 김지수;윤인모;유중석
    • Archives of Plastic Surgery
    • /
    • 제35권2호
    • /
    • pp.223-228
    • /
    • 2008
  • Purpose: V.A.C. is a new concept which is closed dressing with negative pressure to promote wound healing. It has been widely used as the treatment of chronic and acute wounds such as pressure sores, burns, stasis ulcers, and other complicated wounds. However It has disadvantages such as high cost and the need of specific equipment. In this article, we described new method to overcome these disadvantages. Methods: We made newly innovated equipment with 50 cc syringe and spring to create negative pressure. From May 2006 to May 2007, we applied it to two patients with chronic wound. Results: The treatment period was 5 weeks for one case and 3 weeks for the other case. Both patients were healed completely without admission and wound healing was accelerated. During follow-ups, there were no complications. The mean cost for single dressing was 9,590 won. Conclusion: Modified portable negative therapy using newly innovated equipment could accelerate wound healing better than conventional dressing. It lowers the number of dressings, saves cost of treatment, and enables treatment as outpatient basis.

초콜릿 소재의 3차원 프린터 개발에 관한 연구 (A Study on Development of Three-Dimensional Chocolate Printer)

  • 김규언;박근;이치범
    • 한국정밀공학회지
    • /
    • 제34권4호
    • /
    • pp.293-298
    • /
    • 2017
  • In this study, we developed a 3D chocolate printer and studied the conditions needed for chocolate printing. Because chocolate is a mixture of cocoa mass, cocoa butter and sugar particles, its properties vary with temperature, and care is required in melting and extrusion. A chocolate supply unit is composed of a heating block and a syringe pump. It is integrated with a 3-axis linear robot. In order to be more accurate than the existing 3D chocolate printer is, the system was configured so that the printing line width became $430{\mu}m$. Printing performance was studied according to various parameters. The condition needed for printing lines with a stable width was discovered by the experimental design method and has been confirmed by a 2D line test. These 3D printing experiments showed that it was possible to build a 3D shape with an inclination angle of up to $45^{\circ}$ without support. Further, chocolate printing of a 3D shape has been successfully verified with the developed system.

마이크로 레이저 형광 여기법을 이용한 미세채널 내부에서의 산소 확산에 대한 정량적 가시화 (Quantitative Visualization of Oxygen Transfer in Micro-channel using Micro-LIF Technique)

  • 천쥐안;김현동;김경천
    • 한국가시화정보학회지
    • /
    • 제10권1호
    • /
    • pp.34-39
    • /
    • 2012
  • In the present study, oxygen transfer process across gas-liquid interface in a Y-shape micro-channel is quantitatively visualized using the micro laser induced fluorescence (${\mu}$-LIF) technique. Diffusion coefficient of Oxygen ($D_L$) is estimated based on the experimental results and compared to its theoretical value. Tris ruthenium (II) chloride hexahydrate was used as the oxygen quenchable fluorescent dye. A light-emitting diode (LED) with wavelength of 450 nm was used as the light source and phosphorescence images of fluorescent dye were captured by a CMOS high speed camera installed on the microscope system. Water having dissolved oxygen (DO) value of 0% and pure oxygen gas were injected into the Y-shaped microchannel by using a double loading syringe pump. In-situ pixel-by-pixel calibration was carried out to obtain Stern-Volmer plots over whole flow field. Instantaneous DO concentration fields were successfully mapped according to Stern-Volmer plots and DL was calculated as $2.0675{\times}10^{-9}\;m^2/s$.

Fructus Corni Officinalis water extract Ameliorates Memory Impairment and Beta amyloid (Aβ) clearance by LRP-1 Expression in the Hippocampus of a Rat model of Alzheimer’s Disease

  • Lee, Ju Won
    • 동의생리병리학회지
    • /
    • 제30권5호
    • /
    • pp.347-354
    • /
    • 2016
  • This study evaluated the effects of Fructus Corni Officinalis water extract (FCE) on congnitive impairment and Aβ clearance induced by beta amyloid Aβ (1-42) injection in the hippocampus of rat. Aβ (1-42) was injected into the hippocampus using a Hamilton syringe and micropump (5 ㎍/5 ㎕, 1 ㎕/min, each hippocampus bilaterally). FCE was administered orally once a day (100, 250, 500 mg/kg) for 4 weeks after the Aβ (1-42) injection. The acquisition of learning and retention of memory were tested using the Morris water maze. Aβ accumulation and Aβ clearance in the hippocampus were observed using immunostaining. Aβ (1-42) level in plasma was confirmed using enzyme-linked immunosorbent assay (ELISA). FCE significantly shortened the escape latencies during acquisition training trials. FCE significantly increased the number of target heading to the platform site and significantly shortened the time for the 1sttargetheadingduringtheretentiontesttrial.FCEsignificantlyattenuatedtheAβ accumulation in the hippocampus produced by Aβ (1-42) injection. FCE significantly increased LRP-1 expression around vessels in the hippocampus and Aβ (1-42) levels in plasma. The results suggest that FCE improved cognitive impairment by ameliorate Aβ clearance and Aβ accumulation in the hippocampus. FCE may be a beneficial herbal formulation in treating cognitive impairment including Alzheimer's disease.

In-vitro study on the hemorheological characteristics of chicken blood in microcirculation

  • Ji, Ho-Seong;Lee, Jung-Yeop;Lee, Sang-Joon
    • Korea-Australia Rheology Journal
    • /
    • 제19권2호
    • /
    • pp.89-95
    • /
    • 2007
  • The flow characteristics of chicken blood in a micro-tube with a $100{\mu}m$ diameter are investigated using a micro-Particle Image Velocimetry (PIV) technique. Chicken blood with 40% hematocrit is supplied into the micro-tube using a syringe pump. For comparison, the same experiments are repeated for human blood with 40% hematocrit. Chicken blood flow has a cell-free layer near the tube wall, and this layer's thickness increases with the increased flow speed due to radial migration. As a hemorheological feature, the aggregation index of chicken blood is about 50% less than that of human blood. Therefore, the non-Newtonian fluid features of chicken blood are not very remarkable compared with those of human blood. As the flow rate increases, the blunt velocity profile in the central region of the micro-tube sharpens, and the parabolicshaped shear stress distribution becomes to have a linear profile. The viscosity of both blood samples in a low shear rate condition is overestimated, while the viscosity in a high shear rate range is underestimated due to radial migration and the presence of a cell-depleted layer.

The Effect of Sample Handling on the Rheological Measurement of Regenerated Silk Fibroin Formic Acid Solution using Parallel Plate Geometry

  • Cho, Hee-Jung;Um, In-Chul
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제22권1호
    • /
    • pp.5-10
    • /
    • 2011
  • The effect of sample handling condition on the rheological measurement of regenerated silk fibroin formic acid solution using parallel plate geometry was investigated. In case of loading method, the loading by pouring sample solution resulted in the best reproducibility of rheological measurement. Loading with spoon showed a high variance of viscosity value at low shear rate region ($0.01{\sim}1sec^{-1}$) while loading with syringe exhibited a low reproducibility of viscosity at high shear region ($1{\sim}100sec^{-1}$) with a disappearance of shear thinning phenomenon. It was revealed that the sample loading with small extra amount lead to the most reproducible result. The sample loading with the exact amount for the measuring plate resulted in a lack of reproducibility of high shear viscosity, while the loading with large extra volume produced a limited consistency of low shear viscosity. It was turned out that 3 min. of waiting time before measurement was the optimum condition for reliable result. When the waiting time was less than 1 min., the low shear viscosity was obtained with a lack of consistency. On the other hand, the sample solution started drying when the waiting time increased up to 5 min.