• 제목/요약/키워드: Switching system

검색결과 3,329건 처리시간 0.031초

인버터의 손실저감을 위한 소프트 스위칭기법 (A Soft switching method for Loss reduction of Inverter)

  • 곽동걸;김영철;이현우
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.249-252
    • /
    • 2001
  • A large number of soft switching topologies included a resonant circuit have been proposed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this Paper, the authors propose power conversion system, DC-AC inverter of high efficiency and high power factor with soft switching mode by partial resonant method. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source for resonant operation.

  • PDF

컨트롤 샘플링 주기가 스위칭 시스템의 결합-분리 횟수에 미치는 영향을 고려한 제어 알고리듬 개발 (Development of Control Algorithms Considering the Effect of a Control Sampling Period on the Total Amount of Switching for a Switched System)

  • 정진욱;정란
    • 한국지진공학회논문집
    • /
    • 제13권4호
    • /
    • pp.67-76
    • /
    • 2009
  • 최근에 Active interaction control(AIC) 시스템이 준능동 제어 시스템의 하나로 제안되었다. AIC 시스템은 제어 대상 구조물과 보조 구조물로 구성되며, 두 구조물간의 실시간 결합-분리를 통해서 제어 대상 구조물을 제어하게 된다. 구조물간의 결합과 분리를 담당하는 장치의 실시간 변환은 스위칭 제어 알고리듬의 결합-분리 조건식에 의해 제어된다. 기존 스위칭 제어 알고리듬의 경우, 제어 대상 구조물의 응답을 효과적으로 감소시키는 반면 불필요하게 큰 제어력과 과도한 결합-분리 횟수를 필요로 하는 단점을 가지고 있다. 본 논문에서는 구조물간의 효율적인 결합-분리 조정을 위해서 스위칭 활성화 영역과 스위칭 비활성화 영역을 분리 표현하였으며, 결합-조건식에 의해 결정되는 스위칭 활성화 영역과 스위칭 비활성화 영역간의 일반적인 관계를 포괄 스위칭 틀을 이용하여 나타냈다. 과도한 결합-분리 횟수와 불필요하게 큰 제어력의 효과적인 감소를 위해서 새로운 스위칭 제어 알고리듬의 결합-분리 조건식은 포괄 스위칭 틀안에서 설계되었다. 또한 기존 논문에서 사용된 컨트롤 샘플링 주기(Control sampling period)의 역할을 결합-분리 횟수의 관점에서 재해석하였다. 제안된 알고리듬의 효용성과 컨트롤 샘플링 주기의 역할을 검증하기 위해서 단자유도 모델을 이용하여 자유진동에 대한 수치해석을 수행하였다. 수치해석결과, 총 스위칭 횟수를 감소시키기 위한 컨트롤 샘플링 주기의 인위적인 연장은 시스템의 제어 성능 향상에 필요한 구간 변환을 샘플링 주기 사이에서 억제시키는 단점을 가지고 있음을 확인하였다. 본 논문에서 제안된 알고리듬의 경우, 각각 과도한 결합-분리 횟수와 불필요하게 큰 제어력을 감소시키는데 효과적임을 알 수 있다.

Wideband Swtiching System의 Pathsearching 방법에 관한 연구

  • 김성범
    • ETRI Journal
    • /
    • 제5권1호
    • /
    • pp.3-9
    • /
    • 1983
  • 전자교환기의 통화로부분에서 free인 통화로를 선택 접속시켜주는 방법은 통화로의 구성과 기능에 따라 달라진다. 본 논문에서는 일반 전화뿐만 아니라 TV전화, 데이타전송, 비데오텍스(Videotex),스테레오방송 등을 교환 접속시켜 주는 광대역용 전자교환기(Wideband switching system)의 교환접속망(Switching matrix)을 효과적으로 구성하여 통화로 선택이 전교환접속망에 걸쳐 고루 분포될 수 있는 방법을 제안하였다. 그리고 그에 따른 pathsearching simulation program을 작성하여 실예를들어 설명함으로써 본 논문에서 제안한 통화노선택방법의 유용성을 보였다.

  • PDF

가변구조계에 대한 스윗칭 초평면 설정의 한 방법 (Construction Method of Switching Hyperplane for Variable Structure Systems)

  • 오세준;김상봉;하주식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제14권3호
    • /
    • pp.42-51
    • /
    • 1990
  • A construction method of a switching hyperplane for the Variable Structure Systems, which have robustness for parameter variations and noises in sliding mode is presented. The problem of composing a switching hyperplane is considered as a special case of the pole assignment for a closed-loop system. It is shown that the condition for constructing arbitrarily a switching hyperplane matrix C is equivalent to the controllability of the pair matrix(A, B) for the system, and then an algorithm of obtaining the switching hyperplane is proposed. It is also proved that zeros of the system are invariable in the sliding mode, and the stability for the system dynamic is equivalent to the stability of PA $\textit{ker}$ C. The applicability of the method proposed in the paper is shown by the simulation results for an example system.

  • PDF

가변구조 제어계통에 의한 직류 전동기의 위치제어기 설계 (Design of Digital Position Controller for DC Motors Using Variable Structure Control System)

  • 박귀태;송명현;강대린
    • 대한전기학회논문지
    • /
    • 제38권3호
    • /
    • pp.228-236
    • /
    • 1989
  • The theroy of variable structure control system (VSS) is applied to the position control for DC servo-motors. In order to use the microcomputer as a control device, the principles of VSS for the continuous-time system are extended to the discrete-time system. A new switching law is proposed to achieve the reduction of chattering. It adds a new switching structure to the conventional switching sturctures. This switching region is set near and including the conventional switching curve. The new algorithm is obtained for single-input second order system, and applied to the position control of a DC servo-motor. Experimental results show that the transient behavior is improved due to the reduction of chattering and good robustness properties are demonstrated.

  • PDF

스위칭 제어 기법을 이용한 볼-빔 시스템의 제어 (Control of a Ball and Beam System using Switching Control Method)

  • 이경태;정민길;최호림
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.72-81
    • /
    • 2017
  • We propose a switching control scheme for the control of a ball and beam system. It was reported in [4] that a ball and beam system is a nonlinear system which has an ill-defined relative degree. So, the traditional control approaches have been mostly either Jacobian-based control or approximate input-output linearized control in nature. In this paper, motivated by [7], we combine these two traditional control approaches and operate each controller via a pre-designed switching logic so that the improved control result can be obtained without any excessive use of control input. Switching algorithm is developed based on both analysis and actual experimental observation. We verify the effectiveness of our proposed controller via actual experimental results.

A proposal of switching control system based on speculative control and its application to antiskid braking system

  • Masaaki Inaba;Ikuo Yoshinhara;Hai-jiao Guo;Kazuo Nakao;Kenichi Abe
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.585-588
    • /
    • 1997
  • This paper presents a construction method of logic-based switching control system which operates in widely changing environments. The logic-based switching controller is composed of a family of candidate controllers together with a supervisor. The system does not require any identification schemes of environments. Switching from one candidate controller to another is carried out based on monitoring the output of the system. The basic ideas of adaptation are as follows: (1)each candidate controller is prepared for each environment in advance; (2)the supervisor applies a sequence of speculative controls to a plant with candidate controllers just after the control has started and just after the change of the environment has been detected. It is important that each candidate controller can keep the system stable during a sequence of speculative controls, and the most appropriate candidate controller for the environment to which the system is exposed can be selected before the last speculative control is ended. An application to an antiskid braking system clarifies the effectiveness of the proposed method.

  • PDF

345kV 지중 및 혼합 송전계통에서의 개폐 과전압 해석 (Analysis of Switching Overvoltage in 345kV Underground and Combined Transmission Systems)

  • 정채균;이종범;강지원
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권12호
    • /
    • pp.713-721
    • /
    • 2003
  • This paper analyzes the switching overvoltage occurred on 345kV underground power cable system as well as combined transmission system using EMTP. Cable length and closing time, preinsertion resistance have effect on switching overvoltage. Therefore, this paper analyzes the switching overvoltage occurred on conductor and sheath with change of those parameters. Specially, the cross bonding position becomes discontinuity point because of the difference between surge impedance of metal sheath and that of lead cable. Thus, the transmission and the reflection of traveling wave complexly occur at this connection point. According to these influences, voltage between sheath and earth as well as voltage between joint boxes rise. Time to crest point of switching overvoltage is longer than lightning overvoltage. Even though the voltage induced by switching surge is smaller than lightning surge, that voltage may have serious effect on the metal sheath. Therefore, this paper also analyses the reduction effect of switching overvoltage when the preinsertion resistance of circuit breaker is considered.

CoMP Transmission for Safeguarding Dense Heterogeneous Networks with Imperfect CSI

  • XU, Yunjia;HUANG, Kaizhi;HU, Xin;ZOU, Yi;CHEN, Yajun;JIANG, Wenyu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권1호
    • /
    • pp.110-132
    • /
    • 2019
  • To ensure reliable and secure communication in heterogeneous cellular network (HCN) with imperfect channel state information (CSI), we proposed a coordinated multipoint (CoMP) transmission scheme based on dual-threshold optimization, in which only base stations (BSs) with good channel conditions are selected for transmission. First, we present a candidate BSs formation policy to increase access efficiency, which provides a candidate region of serving BSs. Then, we design a CoMP networking strategy to select serving BSs from the set of candidate BSs, which degrades the influence of channel estimation errors and guarantees qualities of communication links. Finally, we analyze the performance of the proposed scheme, and present a dual-threshold optimization model to further support the performance. Numerical results are presented to verify our theoretical analysis, which draw a conclusion that the CoMP transmission scheme can ensure reliable and secure communication in dense HCNs with imperfect CSI.

A Primary-Side-Assisted Zero-Voltage and Zero-Current Switching Three-Level DC-DC Converter

  • Jeon S. J.;Canales F.;Barbosa P. M.;Lee F. C.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.227-231
    • /
    • 2001
  • A new primary-side-assisted zero-voltage and zero-current switching (ZVZCS) three-level DC-DC converter with flying capacitor is proposed. The three-level converters are promising in high voltage applications, and ZVZCS is a very effective means for reducing switching losses. The proposed DC-DC converter uses only one auxiliary transformer and two diodes to obtain ZCS for the inner leg. It has a simple and robust structure, and offers soft-switching capability even in short-switching conditions. The proposed converter was verified by experiments in a 6KW prototype designed for communication applications and operating at 100kHz.

  • PDF