• Title/Summary/Keyword: Switching loss

Search Result 1,110, Processing Time 0.021 seconds

Discontinuation Rate of Doxepin in Insomnia Patients (불면증 환자의 Doxepin 치료 중단율)

  • Lee, Ji Hyeon;Kim, Sung-Min;Hong, Seung-Chul;Seo, Ho-Jun;Kim, Tae-Won;Um, Yoo-Hyun;Jeong, Jong-Hyun
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.26 no.1
    • /
    • pp.51-58
    • /
    • 2018
  • Objectives : We aimed to investigate the discontinuation rate and reasons of doxepin base prescription pattern in insomnia outpatients of psychiatry department of a university hospital. Methods : 534 patients prescribed doxepin were screened. 201 patients were included and reviewed for their medical records retrospectively. The discontinuation rate and reasons of doxepin after 2 months of prescription were investigated. Patients were divided into three groups according to the prescription patterns. The initial group, prescribed doxepin as the first hypnotic, the add-on group, prescribed doxepin while maintaining existing hypnotics, and the switching group, prescribed doxepin after discontinuation of existing hypnotics. Results : The discontinuation rate after 2 months of prescription of doxepin was 56.2%. There were significant differences in the discontinuation rate among three groups. The initial group had the highest while the add-on group had the lowest (p=0.018). In reasons for discontinuation of doxepin among three groups, lack of efficacy (p<0.001) and adverse events (p<0.001) were significantly higher in the add-on group. In the initial group, patient's refusal (p=0.022) and unknown or loss to follow up (p<0.001) were significantly higher. Conclusions : The results of this study suggested that add-on is superior than switching method and gradual reduction of existing hypnotics is necessary to maintain doxepin treatment and prevent adverse events. Additional large scale prospective studies are needed to evaluate various factors and risks of discontinuation of doxepin.

The design of the high efficiency DC-DC Converter with Dynamic Threshold MOS switch (Dynamic Threshold MOS 스위치를 사용한 고효율 DC-DC Converter 설계)

  • Ha, Ka-San;Koo, Yong-Seo;Son, Jung-Man;Kwon, Jong-Ki;Jung, Jun-Mo
    • Journal of IKEEE
    • /
    • v.12 no.3
    • /
    • pp.176-183
    • /
    • 2008
  • The high efficiency power management IC(PMIC) with DTMOS(Dynamic Threshold voltage MOSFET) switching device is proposed in this paper. PMIC is controlled with PWM control method in order to have high power efficiency at high current level. DTMOS with low on-resistance is designed to decrease conduction loss. The control parts in Buck converter, that is, PWM control circuits consist of a saw-tooth generator, a band-gap reference circuit, an error amplifier and a comparator circuit as a block. The Saw-tooth generator is made to have 1.2 MHz oscillation frequency and full range of output swing from ground to supply voltage(VDD:3.3V). The comparator is designed with two stage OP amplifier. And the error amplifier has 70dB DC gain and $64^{\circ}$ phase margin. DC-DC converter, based on Voltage-mode PWM control circuits and low on-resistance switching device, achieved the high efficiency near 95% at 100mA output current. And DC-DC converter is designed with LDO in stand-by mode which fewer than 1mA for high efficiency.

  • PDF

A Study on Power Conversion System for Fuel Cell Controlled by Micro-Processor (마이크로프로세서에 의해 제어되는 연료전지용 전력변환장치에 관한 연구)

  • Kim, Ju-Yong;Jung, Sang-Hwa;Mun, Sang-Pil;Ryu, Jae-Yup;Suh, Ki-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.10-24
    • /
    • 2007
  • In the dissertation, a power conversion system for fuel cell is composed of a PWM inverter with LC filter in order to convert fuel cell voltage to a single phase 220[V]. In addition, new insulated DC-DC converters are proposed in order that fuel cell voltage is boosted to 380[V]. In this paper, it requires smaller components than existing converters, which makes easy control. The proposed DC-DC converter controls output power by the adjustment of phase-shift width using switch $S_5\;and\;S_6$ in the secondary switch which provides 93-97[%] efficiency in the wide range of output voltage. Fuel cell simulator is implemented to show similar output characteristics to actual fuel cell. Appropriate dead time td enables soft switching to the range where the peak value of excitation current in a high frequency transformer is in accordance with current in the primary circuit. Moreover, appropriate setting to serial inductance La reduces communication loss arisen at light-load generator and serge voltage arisen at a secondary switch and serial diode. Finally, TMS320C31 board and EPLD using PWM switching technique to act a single phase full-bridge inverter which is planed to make alternating current suitable for household

Ti:LiNbO3 three-waveguide type traveling-wave optical modulator; outer fed, anti-symmetrical Detuning (Ti:LiNbO3 세 도파로형 진행파 광변조기;바깥입사, 반대칭 Detuning)

  • 이우진;정은주;피중호;김창민
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.375-384
    • /
    • 2004
  • Switching phenomenon of a three-waveguide optical coupler was analyzed by using the coupled mode theory, and the coupling-length of the device was calculated by means of the FDM. CPW traveling-wave electrodes were designed by the CMM and SOR simulation techniques so as to satisfy the conditions of phase-velocity and impedance matching. Traveling-wave modulators were fabricated on a z-cut LiNbO$_3$ substrate. Ti was in-diffused in LiNbO$_3$ to make waveguides and Au electrodes were built on the waveguides by the electroplating technique. Insertion loss and switching voltage of the optical modulator were about 4 ㏈ and 15.6V. Network analyzer was used to obtain S parameters and corresponding RF response. From the measurement, parameters of the traveling-wave electrodes were extracted as such Z$_{c}$=39.2 $\Omega$, Neff=2.48, and a0=0.0665/cm((GHz) (1/2)). The measured optical response R(w) was compared with the theoretically estimated and both responses were shown to agree well. The measurement results revealed that the ㏈ bandwidth turned out to be about 13 GHz.

A Study on the Performance Analysis and synthesis for a Differentiated Service Networks (차등 서비스 네트워크에 대한 성능 분석과 합성에 대한 연구)

  • Jeon, Yong-Hui;Park, Su-Yeong
    • The KIPS Transactions:PartC
    • /
    • v.9C no.1
    • /
    • pp.123-134
    • /
    • 2002
  • The requirement for QoS (Quality of Service) has become an important Issue as real-time or high bandwidth services are increasing, such as Internet Telephony, Internet broadcasting, and multimedia service etc. In order to guarantee the QoS of Internet application services, several approaches are being sought including IntServ (Integrated Service) DiffServ(Differentiated Srvices), and MPLS(Multi-Protocol Label Switching). In this paper, we describe the performance analysis of QoS guarantee mechanism using the DiffServ. To analyze how the DiffServ performance was affected by diverse input traffic models and the weight value in WFQ(Weighted Fair Queueing), we simulated and performed performance evaluation under a random, bursty, and self-similar input traffic models and for diverse input parameters. leased on the results of performance analysis, it was confirmed that significant difference exist in packet delay and loss depending on the input traffic models used. However, it was revealed that QoS guarantee is possible to the EF (expedited Forwarding) class and the service separation between RF and BE (Best Effort) classes may also be achieved. Next, we discussed the performance synthesis problem. (i. e. derived the conservation laws for a DiffServ networks, and analysed the performance variation and dynamic behavior based on the resource allocation (i.e., weight value) in WFQ.

Economic Evaluations of Facility Farms by the Introduction of Mango Ultra-High Density Pot Cultivation (망고 초밀식 화분재배 도입 시설농가의 경제성 평가)

  • Jeong, U Seok;Kim, Seongsup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.279-290
    • /
    • 2021
  • This study evaluated the economic feasibility of facility farms according to the introduction of the ultra-high density pot cultivation (UHDPC) for mango. The basic model was selected as a representative farmhouse case in the Jeonnam region, and seven scenarios for conventional crops were tested. The economic feasibility of crop switching was analyzed through partial budget analysis (PBA). The PBA analysis results were supplemented by adding a sensitivity analysis and a break-even point (BEP) analysis. As a result of the analyses, it was found that crop conversion was economical because the increase in the profit coefficient was greater than the increase in the loss coefficient due to the introduction of mango for all conventional crops. The economics of introducing mango was more sensitive to changes in gross income than to changes in cost items. The results show the detailed conditions of crop selection according to the conditions and preferences of individual farms by presenting the direction of increase and decrease by budget item and information on the amount of increase or decrease. In particular, the BEP analysis result, which is about half of the farms case, is significant in that it presents the minimum target value according to production and market risks.

Hotel employee's perceptions of artificial intelligence concierge robots effect on switching cost, resistance, turnover intention (호텔 종업원의 인공지능 컨시어지로봇에 대한 인식이 전환비용, 저항 및 이직의도에 미치는 영향)

  • Wang, Danping;Chung, Namho
    • Journal of Service Research and Studies
    • /
    • v.13 no.4
    • /
    • pp.206-223
    • /
    • 2023
  • The introduction of Smart technologies such as Artificial Intelligence(AI) systems are have a powerful impact in a variety of industry fields. Some experts predict that smart technology will completely change people's daily life and work styles, causing technological innovation, productivity improvement, and discovery and emergence of new fields. On the one hand, this vision cannot ignore negative views and concerns. Despite many social debates about employment, such as job loss and rising unemployment, there have not been many studies based on employee experience that provide a fundamental solution to the conflict between AI and employment. Therefore, this study finds out the effects and related factors of AI concierge robots for hotel employees, focusing on the hotel industry, and how employees' perceptions of AI concierge robots affect user resistance and turnover intention. This study, conducted a questionnaire survey of 322 hotel employees who had experience working with AI concierge robots in China, and used SPSS and SmartPLS statistical analysis programs to draw conclusions. We found that hotel employees' perceptions of AI concierge robots were significantly related to user resistance and turnover intention, and this association was related to employee self-efficacy, perceived organizational support, quality of AI services and new tasks. In addition, it was found that the quality of AI concierge robots directly or indirectly had the greatest influence on user resistance and turnover intention. The findings of this study provide theoretical implications for academia and practical implications for industry practitioners.

A Study on Output Enhancement Method of PV Array Using Electrical Circuit Reconfiguration Algorithm (전기적 회로절체 알고리즘에 의한 태양광 어레이의 출력향상 방안에 관한 연구)

  • Kim, Byung-Mok;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.9-17
    • /
    • 2020
  • Recently, RES (renewable energy source) projects have been spreading all over the world as an alternative to solve the shortage of energy and environmental problems caused by fossil fuel consumption. The Korean government also supported the policy and demonstration project to increase the proportion of renewable energy to 63.8[GW] until 2030, which is 20[%] of the total power generation. On the other hand, output loss of a PV array can occur when the surrounding high-rise buildings and trees shade a PV array. Therefore, this paper proposes an algorithm to improve the output loss of a PV array, which electrically changes a circuit configuration of PV modules by wiring and switching devices. Furthermore, this study modeled a PV system based on PSIM S/W, which was composed of a PV array, a circuit configuration device, and a grid-connected inverter. From the simulations results with the modeling and test device, the existing method showed no output when 50% of the shade occurs in PV modules. In contrast, the proposed method could produce the output because the voltage in the PV module could be restored to 246[V], and the operation efficiency of the PV system could be improved by the operation algorithm of the circuit configuration device.

Design of pHEMT channel structure for single-pole-double-throw MMIC switches (SPDT 단일고주파집적회로 스위치용 pHEMT 채널구조 설계)

  • Mun Jae Kyoung;Lim Jong Won;Jang Woo Jin;Ji, Hong Gu;Ahn Ho Kyun;Kim Hae Cheon;Park Chong Ook
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.207-214
    • /
    • 2005
  • This paper presents a channel structure for promising high performance pseudomorphic high electron mobility transistor(pHEMT) switching device for design and fabricating of microwave control circuits, such as switches, phase shifters, attenuators, limiters, for application in personal mobile communication systems. Using the designed epitaxial channel layer structure and ETRI's $0.5\mu$m pHEMT switch process, single pole double throw (SPDT) Tx/Rx monolithic microwave integrated circuit (MMIC) switch was fabricated for 2.4 GHz and 5 GHz band wireless local area network (WLAN) systems. The SPDT switch exhibits a low insertion loss of 0.849 dB, high isolation of 32.638 dB, return loss of 11.006 dB, power transfer capability of 25dBm, and 3rd order intercept point of 42dBm at frequency of 5.8GHz and control voltage of 0/-3V These performances are enough for an application to 5 GHz band WLAN systems.

PV Inverter Operation according to DC Capacitor Aging (직류 커패시터 노후화에 따른 PV 인버터 동작)

  • Yongho Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.149-155
    • /
    • 2023
  • Photovoltaic power generation is the most familiar power generation facility among new and renewable energies, and its supply began to expand about 10 years ago, and at this point, interest in solutions and technologies for system maintenance management is increasing. In particular, it is necessary to take measures to maximize the overall efficiency of the solar power generation system, whether or not there is an abnormality in the solar power generation system, and when to replace parts. The PV inverter, one element of the photovoltaic power generation system, is a power conversion system that relies on power switching devices, and DC-Link capacitors are used according to the configuration of DC/DC converters and DC-AC inverters. These DC capacitors also affect system safety (Safety) through renewable energy facilities due to the decrease in power generation of PV inverters, power loss, and increase in harmonics (THD, total distortion of AC output current) due to aging and deterioration due to long-term use. factors can be analyzed. Therefore, in this paper, the PV inverter operating characteristics according to the DC capacitor capacity state currently operating in the photovoltaic power generation system were considered, and research contents were proposed to secure the safety and reliability of renewable energy facilities.