• Title/Summary/Keyword: Switching Time

Search Result 1,898, Processing Time 0.032 seconds

A Study of Basic Design Method for High Availability Clustering Framework under Distributed Computing Environment (분산컴퓨팅 환경에서의 고가용성 클러스터링 프레임워크 기본설계 연구)

  • Kim, Jeom Goo;Noh, SiChoon
    • Convergence Security Journal
    • /
    • v.13 no.3
    • /
    • pp.17-23
    • /
    • 2013
  • Clustering is required to configure clustering interdependent structural technology. Clustering handles variable workloads or impede continuity of service to continue operating in the event of a failure. Long as high-availability clustering feature focuses on server operating systems. Active-standby state of two systems when the active server fails, all services are running on the standby server, it takes the service. This function switching or switchover is called failover. Long as high-availability clustering feature focuses on server operating systems. The cluster node that is running on multiple systems and services have to duplicate each other so you can keep track of. In the event of a node failure within a few seconds the second node, the node shall perform the duties broken. Structure for high-availability clustering efficiency should be measured. System performance of infrastructure systems performance, latency, response time, CPU load factor(CPU utilization), CPU processes on the system (system process) channels are represented.

Fault Diagnosis of Voltage-Fed Inverters Using Pattern Recognition Techniques for Induction Motor Drive (패턴인식 기법을 이용한 유도전동기 구동용 전압형 인버터의 고장진단)

  • Park, Jang-Hwan;Park, Sung-Moo;Lee, Dae-Jong;Kim, Dong-Hwa;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.75-84
    • /
    • 2005
  • Since an unexpected fault of induction motor drive systems can cause serious troubles in many industrial applications, which the technique is required to diagnose faults of a voltage-fed PWM inverter for induction motor drives. The considered fault types are rectifier diodes, switching devices and input terminals with open-circuit faults, and the signal for diagnosis is derived from motor currents. The magnitude of dq-current trajectory is used for the feature extraction of a fault and PCA LDA are applied to diagnose. Also, we show results with respect to the execution time because of the possibility to use that a diagnosis software is embedded in the controllers of medium and small size induction motors drive for real-time diagnosis. After we performed various simulations for the fault diagnosis of the inverter, the usefulness of proposed algerian was verified.

An Implementation of the Real Time Speech Recognition for the Automatic Switching System (자동 교환 시스템을 위한 실시간 음성 인식 구현)

  • 박익현;이재성;김현아;함정표;유승균;강해익;박성현
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.31-36
    • /
    • 2000
  • This paper describes the implementation and the evaluation of the speech recognition automatic exchange system. The system provides government or public offices, companies, educational institutions that are composed of large number of members and parts with exchange service using speech recognition technology. The recognizer of the system is a Speaker-Independent, Isolated-word, Flexible-Vocabulary recognizer based on SCHMM(Semi-Continuous Hidden Markov Model). For real-time implementation, DSP TMS320C32 made in Texas Instrument Inc. is used. The system operating terminal including the diagnosis of speech recognition DSP and the alternation of speech recognition candidates makes operation easy. In this experiment, 8 speakers pronounced words of 1,300 vocabulary related to automatic exchange system over wire telephone network and the recognition system achieved 91.5% of word accuracy.

  • PDF

A Feedback Control Model for ABR Traffic with Long Delays (긴 지연시간을 갖는 ABR 트래픽에 대한 피드백제어 모델)

  • O, Chang-Yun;Bae, Sang-Hyeon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.4
    • /
    • pp.1211-1216
    • /
    • 2000
  • Asynchronous transfer mode (ATM) can be efficiently used to transport packet data services. The switching system will support voice and packet data services simultaneously from end to end applications. To guarantee quality of service (QoS) of the offered services, source rateot send packet data is needed to control the network overload condition. Most existing control algorithms are shown to provide the threshold-based feedback control technique. However, real-time voice calls can be dynamically connected and released during data services in the network. If the feedback control information delays, quality of the serviced voice can be degraded due to a time delay between source and destination in the high speed link. An adaptive algorithm based on the optimal least mean square error technique is presented for the predictive feedback control technique. The algorithm attempts to predict a future buffer size from weight (slope) adaptation of unknown functions, which are used fro feedback control. Simulation results are presented, which show the effectiveness of the algorithm.

  • PDF

An ABR Service Traffic Control of Using feedback Control Information and Algorithm (피드백 제어 정보 및 알고리즘을 이용한 ABR 서비스 트래픽제어)

  • 이광옥;최길환;오창윤;배상현
    • Journal of Internet Computing and Services
    • /
    • v.3 no.3
    • /
    • pp.67-74
    • /
    • 2002
  • Asynchronous transfer mode (ATM) can be efficiently used to transport packet data services. The switching system will support voice and packet data services simultaneously from end to end applications. To guarantee quality of service (QoS) of the offered services, source rate to send packet data is needed to control the network overload condition. Most existing control algorithms are shown to provide the threshold-based feedback control technique. However, real-time voice calls can be dynamically connected and released during data services in the network. If the feedback control information delays, quality of the serviced voice can be degraded due to a time delay between source and destination in the high speed link, An adaptive algorithm based on the optimal least mean square error technique is presented for the predictive feedback control technique. The algorithm attempts to predict a future buffer size from weight (slope) adaptation of unknown functions, which are used for feedback control. Simulation results are presented, which show the effectiveness of the algorithm.

  • PDF

Phenomenon of the absorptive optical bistabililty in amorphous $As_2S_3$ thin film (비정질 $As_2S_3$ 박막에서의 흡수형 광쌍안정 현상)

  • 안웅득;김석원;한성홍
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.129-135
    • /
    • 1996
  • We observed the absorptive optical bistability in the single layer amorphous $As_2S_3$ thin film which has an isolated electron pairs at roomtemperature, for the frist time, $Ar^+$ laser beam (λ=514.5 nm) was used as a light source and was focused by thin lens. The experiment was performed in cavityless system and the occurrence of optical bistability in this material could be explained by the temperature-dependent absorption coefficient of the sample. Also, this effect was explained by the reversible shift of the absorption edge in this material. The condition of optical bistability is determined by detuning value ($a_0L$) and this value was 0.12 when thikness of that sample was about 0.8 ${\mu}{\textrm}{m}$. The switching was observed clealy when light intensity is 150~180 mW and the swiching time was about $10^{-4}$ s.

  • PDF

Atomic layer deposition of In-Sb-Te Thin Films for PRAM Application

  • Lee, Eui-Bok;Ju, Byeong-Kwon;Kim, Yong-Tae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.132-132
    • /
    • 2011
  • For the programming volume of PRAM, Ge2Sb2Te5(GST) thin films have been dominantly used and prepared by physical vapor deposition (PVD), chemical vapor deposition (CVD), atomic layer deposition (ALD). Among these methods, ALD is particularly considered as the most promising technique for the integration of PRAM because the ALD offers a superior conformality to PVD and CVD methods and a digital thickness control precisely to the atomic level since the film is deposited one atomic layer at a time. Meanwhile, although the IST has been already known as an optical data storage material, recently, it is known that the IST benefits multistate switching behavior, meaning that the IST-PRAM can be used for mutli-level coding, which is quite different and unique performance compared with the GST-PRAM. Therefore, it is necessary to investigate a possibility of the IST materials for the application of PRAM. So far there are many attempts to deposit the IST with MOCVD and PVD. However, it has not been reported that the IST can be deposited with the ALD method since the ALD reaction mechanism of metal organic precursors and the deposition parameters related with the ALD window are rarely known. Therefore, the main aim of this work is to demonstrate the ALD process for IST films with various precursors and the conformal filling of a nano size programming volume structure with the ALD?IST film for the integration. InSbTe (IST) thin films were deposited by ALD method with different precursors and deposition parameters and demonstrated conformal filling of the nano size programmable volume of cell structure for the integration of phase change random access memory (PRAM). The deposition rate and incubation time are 1.98 A/cycle and 25 cycle, respectively. The complete filling of nano size volume will be useful to fabricate the bottom contact type PRAM.

  • PDF

Authentication and Session Management based on Ajax (Ajax를 기반으로 한 인증 및 세션 관리)

  • Nam Sang-On;Daguil Rolyn C;Kim Gi-Weon;Song Jung-Gil
    • Journal of Internet Computing and Services
    • /
    • v.7 no.6
    • /
    • pp.157-174
    • /
    • 2006
  • Ajax interaction model changes the posture of web application to become a stateful over HTTP. Ajax applications are long-lived inthe browser. XMLHTTPRequest (XHR) is used to facilitate the data exchange. Using HTTPS over this interaction is not viable because of the frequency of data exchange. Moreover, switching of protocols form HTTP to HTTPS for sensitive information is prohibited because of server-of-origin policy. The longevity, constraint, and asynchronous features of Ajax application need to hove a different authentication and session fondling mechanism that invoke re-authentication. This paper presents an authentication and session management scheme using Ajax. The scheme is design lo invoke periodic and event based re-authentication in the background using digest authentication with auto-generated password similar to OTP (One Time Password). The authentication and session management are wrapped into a framework called AWASec (Ajax Web Application Security) for coupling to avoid broken authentication and session management.

  • PDF

A Study on The Development and Function Test of Digital Transformer Protection Relay Using The Induced Voltage (유기전압비를 이용한 디지털형 변압기 보호계전기 개발 및 성능시험에 관한 연구)

  • Jung, Sung-Kyo;Lee, Jae-Kyung;Kim, Han-Do;Choi, Dae-Gil;Kang, Yong-Chul;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.216-218
    • /
    • 2001
  • The transformer role is very important in power system operation and control; also its price is very expensive. Therefore many kinds of the efforts for transformer protection have been executed. So for as, current differential relay(87) has been mainly used for transformer protection. But current differential relaying method has several troubles as followings. Differential current can be occurred by transformers inrush current between winding1 and winding2 of transformer when transformer is initially energized. Also harmonic restrained element used in current differential relaying method is one of the causes of relays mal-operation because recently harmonics in power system gradually increase by power switching devices(SVC, FACTS, DSC, etc). Therefore many kinds of effort have been executed to solve the trouble of current differential relay and one of them is method using ratio of increment of flux linkages(RIFL) of the primary and secondary windings. This paper introduces a novel protective relay for power transformers using RIFL of the primary and secondary windings. Novel protective relay successfully discriminates between transformer internal faults and normal operation conditions including inrush and this paper includes real time test results using RTDS(Real Time Digital Simulator) for novel protective relay. A novel protective relay was designed using the TMS320C32 digital signal processor and consisted of DSP module. A/D converter module, DI/DO module, MMI interface module and LCD display module and developed by Xelpower co., Ltd.

  • PDF

An Improved Dynamic Quantum-Size Pfair Scheduling for the Mode Change Environments (Mode Change 환경을 위한 개선된 동적 퀀텀 크기 Pfair 스케줄링)

  • Cha, Seong-Duk;Kim, In-Guk
    • Journal of Digital Contents Society
    • /
    • v.8 no.3
    • /
    • pp.279-288
    • /
    • 2007
  • Recently, Baruah et. al. proposed an optimal Pfair scheduling algorithm in the real-time multiprocessor system environments, and several variants of it were presented. All these algorithms assume the fixed unit quantum size. However, under Pfair based scheduling algorithms that are global scheduling technique, quantum size has direct influence on the scheduling overheads such as task switching and cache reload. We proposed a method for deciding the optimal quantum size[2] and an improved method for the task set whose utilization e is less than or equal to $e\;{\leq}\;p/3+1$[3]. However, these methods use repetitive computation of the task's utilization to determine the optimal quantum size. In this paper, we propose a more efficient method that can determine the optimal quantum size in constant time.

  • PDF