• 제목/요약/키워드: Switching Time

검색결과 1,903건 처리시간 0.029초

비정질 As-Ge-Te 박막의 물리적 성질 및 스위칭 특성 (The physical properties and switching characteristics of amorphous As-Ge-Te thin film)

  • 이현용;천석표;이영종;정홍배
    • 대한전기학회논문지
    • /
    • 제44권7호
    • /
    • pp.901-907
    • /
    • 1995
  • The switching characteristics of As$_{10}$ Ge$_{15}$ Te$_{75}$ thin film were investigated under d.c. bias. And the frequency dependence of the conductivity was analysed with regard to the temperature dependence, in order to find the physical properties of the As$_{10}$ Ge$_{15}$ Te$_{75}$ thin film ; a characteristic relaxation time (.tau.$_{0}$ ), the spatial density of defect states (N), and the localized wavefunction (.alpha.$^{-1}$ ). It was formed that the threshold voltage depends on thickness, electrode distance, annealing time and temperature, respectively. The threshold voltage is increased as the thickness and the electrode distance is increased, while the threshold voltage is decreased in proportion to the increased annealing time and temperature.

  • PDF

스위칭 데드타임에 의한 인버터 출력 전압의 오차 해석 (Analysis of the Errors on the Output voltage of Inverter Caused by Switching Dead Time)

  • 조규민
    • 전자공학회논문지S
    • /
    • 제36S권11호
    • /
    • pp.120-127
    • /
    • 1999
  • PWM 전압형 인버터의 스위칭 신호에 삽입되는 데드타임은 인버터의 출력에 왜형을 발생시키다. 그 결과, 지령에 대비한 기본파분 전압의 크기 및 위상의 편차가 발생한다. 뿐만 아니라 인버터 출력에 고조파를 증가시킨다. 본 논문에서는 스위칭 데드타임에 기인한 인버터 출력의 왜형분 전압에 대한 수식적 해석을 수행하였다. 연산 결과로써, 전압변조율, 부하 기본파 역율 및 데드타임에 다른 출력 전압의 기본파 전압 이득 및 위상 편차를 나타내었다.

  • PDF

Time Resolved Infrared Spectroscopy of Electro-optic Switching of 5CB

  • Jang, Won-Gun
    • Journal of Information Display
    • /
    • 제5권1호
    • /
    • pp.34-40
    • /
    • 2004
  • Time resolved infrared IR absorption spectroscopy is carried out to investigate the dynamics of electric field induced reorientation of the biphenyl molecular core and alkyl tail sub-fragments of the nematic liquid crystal 5CB (4-pentyl-4-cyano-biphenyl). The planar to homeotropic transition for high pre-tilt planar aligned cells, is studied for switching times ranging from 200 ${\mu}sec$ down to 80 ${\mu}sec$, the latter a factor of 1000 times faster than any previous nematic IR study. The reorientation rates of the core and tail are found to be the same to within experimental error and scale inversely with applied field squared, as expected for the balance of field and viscous torques. Thus any molecular conformation change during switching must relax on a shorter time scale. A simple model shows that no substantial differences exist between the reorientational dynamics of the tails and cores on the time scales longer than on the order of 10 ${\mu}s$.

교환시스템의 서비스 품절수준 향상을 위한 소프트웨어 블록의 중요도 결정 (Determination of Importance of Software Blocks for Improving Quality of Service in Switching System)

  • 조재균
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제8권1호
    • /
    • pp.93-108
    • /
    • 1999
  • The switching system is designed and developed to satisfy the performance design objectives recommended by ITU for call processing capacity and quality of service(QOS), etc. When the results by actual measurement at the system testing phase do not satisfy the performance design objectives, however, an effort is required to improve the performance. This paper presents a method for improving QOS by modifying the application programs for the switching system. In the proposed method, the sequence chart related to a delay time for call connection is modelled using PERT(Program Evaluation and Review Technique) network. Then, the criticality index of a message is calculated using Monte Carlo simulation to evaluate which message's processing time to decrease in order to decrease the delay time and thus to improve QOS. The criticality index of a block is also calculated to identify those software blocks that significantly contribute to the delay time.

  • PDF

스위칭 전원장치가 입력변압기에 미치는 영향 (Effects of switching power supply on input transformer)

  • 오상록;김병권;성세진;이흥호;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.815-817
    • /
    • 1993
  • In this paper, it is considered spike voltage that is generated by ignoring the recovery time of switching device, turn on and turn off time. In the same principle, this spike voltage will be applicable to diode recovery time. The spike voltage causes to break down insulation of input transformer. So, we will show how to remove spike voltage by optimizing value of R and C and using switching diode which have fast recovery time.

  • PDF

Design and Analysis of Switching Timing for High Power GPS Meaconing Jammer

  • Lee, Byung-Hyun;Oh, In-Geun;Kim, Sung-Il
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제7권4호
    • /
    • pp.227-233
    • /
    • 2018
  • The purpose of satellite navigation meaconing jamming is to make the target GPS receiver calculate false navigation by meaconing the received satellite signals. At this time, since the received and transmitted signals have the same frequency, the back-lobe reduction level of antenna should be -160 dB when the Effective Radiated Power (ERP) is 1 Watt (30 dBm). Therefore, meaconing jamming is impossible by merely reducing the back-lobe level of antenna when the transmitter and receiver are in proximity to each other. In general, the transmitter and receiver are isolated by the time division method to eliminate such transmission/reception interference. This paper studied the optimal switching timing between transmitting and receiving when isolating the time division transmission and reception for GPS meaconing jamming.

Development of the Controlled Switching Device for a Cirrcuit Breaker

  • Kim, Ik-Mo;Kim, Myung-Chan;Choi, Young-Chan;Ryu, Sung-Sic;Kim, Dong-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.558-560
    • /
    • 2004
  • Studies on the controlled switching method have been done to prevent the power system surges which cause the insulation deterioration and electro magnetic compatibility (EMC) problems during closing and opening of a circuit breaker. The controlled switching method controls the closing and tripping time in coincidence with the voltage or current to suppress switching surge. It is used to switch condenser bank, no load transformer, and shunt reactor. In this study, basic concept of the controlled switching is introduced, and also the test is performed to find parameters of the controlled switching in a 24kV vacuum circuit. And then, the control device hardware using TMS320C31 DSP has been designed and manufactured. It has been found that the application of IT technology to a circuit breaker is very effective to depress the switching surge.

  • PDF

Duty Ratio Predictive Control Scheme for Digital Control of DC-DC Switching Converters

  • Sun, Pengju;Zhou, Luowei
    • Journal of Power Electronics
    • /
    • 제11권2호
    • /
    • pp.156-162
    • /
    • 2011
  • The control loop time delay caused by sampling, the zero-order-holder effect and calculations is inevitable in the digital control of dc-dc switching converters. The time delay will limit the bandwidth of the control loop and therefore degrade the transient performance of digital systems. In this paper, the quantization time delay effects with different time delay values based on a generic second-order system are analyzed. The conclusion that the bandwidth of digital control is reduced by about 20% with a one cycle delay and by 50% with two cycles of delay in comparison with no time delay is obtained. To compensate the time delay and to increase the control loop bandwidth, a duty ratio predictive control scheme based on linear extrapolation is proposed. The compensation effect and a comparison of the load variation transient response characteristics with analogy control, conventional digital control and duty ratio predictive control with different time delay values are performed on a point-of-load Buck converter by simulations and experiments. It is shown that, using the proposed technique, the control loop bandwidth can be increased by 50% for a one cycle delay and 48.2% for two cycles of delay when compared to conventional digital control. Simulations and experimental results prove the validity of the conclusion of the quantization effects of the time delay and the proposed control scheme.

인버터 출력 전류제어를 위한 새로운 스위칭 방법 (A New Switching Strategy for The Output Current Control of Inverters)

  • 인치각;오원석;조규민;유완식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.375-377
    • /
    • 1999
  • It is necessary to obtain the high performance of the inverter system that control the output current of inverters. The dead time causes detrimental effects to the control performance of the inverter system. So we need to compensate the dead time effects. And the dead time minimization switching method can be considered as the best way to avoid the dead time effects fundamentally. In this paper, a new dead time minimization switching strategy is proposed. According to the proposed method, very short dead time is adopted in only once when the current polarity is changing. And the adopted dead time is equal to the applied dead time or shorter than it. As the proposed method can be done with the porlarity information of the reference current. it is easy to avoid some problems in comparison with the case that the real current is used to get the polarity changing time; level detection difficulty, noise problem and so on.

  • PDF

다변수 가변구조 제어 시스템에서 시변 스위칭 초평면의 새로운 시도 (New Approach of Time-varying Switching Hyperplane in Multivariable Variable Structure Control Systems)

  • 이주장;김종준;김은선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.402-406
    • /
    • 1990
  • A new approach of a time-varying switching hyperplane based on the theory of variable structure system (VSS) is proposed for the control of multivariable systems. While the conventional switching surface can net achieve the robust performance against parameter variations and disturbances before the sliding mode occurs, the proposed switching hyperplane, which is obtained from the eigen-structure assignment theory powerfully used in the linear multivariable systems, ensures the sliding mode from the initial state. And new continuous control input which guarantees the sliding mode is proposed. This new control input does not arise chattering problem which arises with the conventional control input of variable structure control systems. Through numerical examples, the expellant performances of the proposed controller are verified.

  • PDF