High Efficiency Active Clamp Forward Converter with Synchronous Switch Controlled ZVS Operation

  • Lee Sung-Sae;Choi Seong-Wook;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.131-138
    • /
    • 2006
  • An active clamp ZVS PWM forward converter using a secondary synchronous switch control is proposed in this paper. The proposed converter is suitable for low-voltage and high-current applications. The structure of the proposed converter is the same as a conventional active clamp forward converter. However, since it controls the secondary synchronous switch to build up the primary current during a very short period of time, the ZVS operation is easily achieved without any additional conduction losses of magnetizing current in the transformer and clamp circuit. Furthermore, there are no additional circuits required for the ZVS operation of power switches. Therefore, the proposed converter can achieve high efficiency with low EMI noise, resulting from soft switching without any additional conduction losses, and shows high power dens~ty, a result of high efficiency, and requires no additional components. The operational principle and design example are presented. Experimental results demonstrate that the proposed converter can achieve an excellent ZVS performance throughout all load conditions and demonstrates significant improvement in efficiency for the 100W (5V, 20A) prototype converter.

Novel Two-Phase RPWM Technique for Three-Phase Induction Motor Drive (3상 유도전동기 구동을 위한 새로운 2상 RPWM기법)

  • Lee Hyo-Sang;Kim Nam-Joon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.430-437
    • /
    • 2004
  • This thesis proposes novel SRP-PWM(Separately Random Pulse Position PWM) techniques and novel two-phase switching pattern applied to four-switch inverter, having various advantages such as operation time decrease that is required for decrease of switching damage, easy of implementation and inverter control at high frequency switching. In this thesis, we wish to confirm that SRP-PWM techniques disperse harmonic spectrum of inverter output current evenly into wide frequency area, that is, side-band of specification frequency. And we confirm the harmonic reduction effect of proposed techniques. Therefore, we will achieve an experiment by IGBT inverter using DSP and will verify the validity of proposed techniques compared with simulation results that use MATLAB/SIMULINK.

Utility-Interactive Four-Switch Three-Phase Soft-Switching Inverter with Single Resonant DC-Link Snubber and Boost Chopper

  • Ahmed, Tarek;Nagai, Shinichiro;Nakaoka, Mutsuo;Tanaka, Toshihiko
    • Journal of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.109-117
    • /
    • 2007
  • In this paper, a novel proposal for a utility-interactive three-phase soft commutation sinewave PWM power conditioner with an auxiliary active resonant DC-link snubber is developed for fuel cell and solar power generation systems. The prototype of this power conditioner consists of a PWM boost chopper cascaded three-phase power conditioner, a single two-switch auxiliary resonant DC-link snubber with two electrolytic capacitors incorporated into one leg of a three-phase V-connection inverter and a three-phase AC power source. The proposed cost-effective utility-interactive power conditioner implements a unique design and control system with a high-frequency soft switching sinewave PWM scheme for all system switches. The operating performance of the 10 kW experimental setup including waveform quality, EMI/RFI noises and actual efficiency characteristics of the proposed power conditioner are demonstrated on the basis of the measured data.

Single Buffer types of ATM Switches based on Circulated Priority Algorithm (순환적 순위 알고리즘을 이용한 단일형 버퍼형태의 ATM스위치)

  • Park Byoung-soo;Cho Tae-kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.5
    • /
    • pp.429-432
    • /
    • 2004
  • In this paper, we propose a new sorting algorithm for ATM switch with a shared buffer which has a sequencer architecture with single queue. The proposed switch performs a sorting procedure of ATM cell based on the output port number of ATM cell with hardware implementation. The proposed architecture has a single buffer physically but logically it has function of multi-queue which is designed at most to control the conflicts in output port. In the future, this architecture will take various applications for routing switch and has flexibility for the extension of system structure. therefore, this structure is expected on good structure in effective transmission.

  • PDF

Fault Tolerance Operation and Characteristics Analysis of Asymmetric Six-phase Permanent Magnet Synchronous Motor According to Switch Open (비대칭 6상 영구자석 동기 전동기의 스위치 개방에 따른 특성 분석 및 고장허용운전)

  • Jun, So-Young;Hwang, Seon-Hwan;Park, Jong-Won
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_2
    • /
    • pp.1003-1008
    • /
    • 2022
  • This paper proposes a method related to fault tolerance operation and characteristic analysis of asymmetric 6-phase permanent magnet synchronous motor. In general, motor drive systems with multi-phase structures can be continuously operated despite a reduction of power and speed by using a phase changeover or control techniques according to the failures. As a result, it is widely used in industrial fields such as aviation and defense, which require high efficiency and high reliability. In this paper, the second order ripple of the electrical fundamental freuqnecy occurs in the dq-axis currents of the synchronous coordinate system through mathematical analysis according to the switch open of the dual 3-phase inverter. Therefore, the fault tolerant operation method is presented by applying the fault detection method with a constant cycle for continuous operations. The effectiveness of the proposed fault tolerance operation method is verified through the several experiments.

Performance Analysis of ATM Switch Using Dynamic Priority Control Mechanisms (동적 우선순위 제어방식을 사용한 ATM 스위치의 성능분석)

  • 박원기
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.4
    • /
    • pp.855-869
    • /
    • 1997
  • In this paper, we proposed two kids of dynamic priority control mechanisms controlling the cell service ratio in order to improve the QOS(Quality of Service). We also analyse theoretically the characteristics of cell loss probability and mean cell delay time by applying the proposed priority control mechanisms to ATM switch with output buffer. The proposed priority control mechanisms have the same principles of storing cells into buffer but the different principles of serving cells from buffer. The one is the control mechanism controlling the cell service ratio according to the relative cell occupancy ratio of buffer, the other is the control mechanism controlling the cell service ratio according to both the relative cell occupancy ratio of buffer and the average arrival rate. The two service classes of our concern are the delay sensitive class and the loss sensitive class. The analytical results show that the proposed control mechanisms are able to improve the QOS, the characteristics of cell loss probability and mean cell delay time, by selecting properly the relative cell occupancy ratio of buffer and the average arrival rate. conventional DLB algorithm does not support synchronous cells, but the proposed algorithm gives higher priority to synchronous cells. To reduce synchronous cell loss rate, the synchronous cell detector is used in the proposed algorithm. Synchronous cell detector detects synchronous cells, and passes them cells to the 2nd Leaky-Bucket. So it is similar to give higher priority to synchronous cells. In this paper, the proposed algorithm used audio/video traffic modeled by On/Off and Two-state MMPP, and simulated by SLAM II package. As simulation results, the proposed algorithm gets lower synchronous cell loss rate than the conventional DLB algorithms. The improved DLB algorithm for multimedia synchronization can be extended to any other cells which require higher priority.

  • PDF

Quantitative Evaluation of the First Order Creatine-Kinase Reaction Rate Constant in in vivo Shunted Ovine Heart Treated with Oxandrolone Using Magnetization Transfer 31P Magnetic Resonance Spectroscopy (MT-31P-MRS) and 1 H/31P Double-Tuned Surface Coil: a Preliminary Study

  • Thapa, Bijaya;Dahl, Marjanna;Kholmovski, Eugene;Burch, Phillip;Frank, Deborah;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.26-36
    • /
    • 2018
  • Purpose: Children born with single ventricle physiology demonstrate poor growth rate and suffer from malnutrition, which lead to increased morbidity and mortality in this population. We assume that an anabolic steroid, oxandrolone, will promote growth in these infants by improving myocardial energy utilization. The purpose of this paper is to study the efficacy of oxandrolone on myocardial energy consumption in these infants. Materials and Methods: We modeled single ventricle physiology in a lamb by prenatally shunting the aorta to the pulmonary artery and then postnatally, we monitored cardiac energy utilization by quantitatively measuring the first order reaction rate constant, $k_f$ of the creatine-kinase reaction in the heart using magnetization transfer $^{31}P$ magnetic resonance spectroscopy, home built $^1H/^{31}P$ transmit/receive double tuned coil, and transmit/receive switch. We also performed cine MRI to study the structure and dynamic function of the myocardium and the left ventricular chamber. The spectroscopy data were processed using home-developed python software, while cine data were analyzed using Argus software. Results: We quantitatively measured both the first order reaction rate constant and ejection fraction in the control, shunted, and the oxandrolone-treated lambs. Both $k_f$ and ejection fraction were found to be more significantly reduced in the shunted lambs compared to the control lambs, and they are increased in oxandrolone-treated lambs. Conclusion: Some improvement was observed in both the first order reaction rate constant and ejection fraction for the lamb treated with oxandrolone in our preliminary study.

The Characteristics Analysis of New Dc 48[V] Telecommunication Power System using Forward Type three Phase Rectifier (포워드형 3선 PWM 정류기를 이용한 새로운 DC 48[V] 통신용 전원시스템의 특성 해석)

  • Suh, Ki-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.34-40
    • /
    • 2006
  • This paper proposed power system for new DC 49[V] telecommunication using forward three-phase PWM rectifier power factor and efficiency for improvement of ripple voltage. Proposed power system for DC 48[V] telecommunication that consists of power conversion devices including switch, inductor and condenser were made between each line, in power inverter device of each switch control turn-on in period of continuity time control to get power factor '1' of sine wave current and on-off of switch lessens peak current that was happened and got conversion efficiency 92.1[%] composing in PWM rectifier of forward form instead of general PWM rectifier. Also, harmonic input regulation value(IEC61000-3-2 Class-As) satisfy input current and reduce ripple factor of output voltage in state that distortion of three-phase supply is overlapped each other.

Analysis of the Isolated Boost Converter Using Self-Driven Switch (자기구동 스위치를 이용한 절연된 부스트 변환기의 해석)

  • Hong, Soon-Chan;Chae, Soo-Yong;Chung, Dae-Taek;Kim, Hee-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.89-98
    • /
    • 2010
  • Isolated boost converter is desirable in the dc/dc converter applications where isolation is required and extremely high step up is needed. Transformer used to step up low input voltage into high output voltage must satisfy the volt-sec balance condition. Conventional isolated boost converter is controlled with conducting intervals overlapping. In this case, there is a problem that control circuit is complicated. In this paper, it is proposed and analyzed the isolated boost converter which set up a reset winding for the volt-sec balance of transformer and can construct the control circuit simple by using a self-driven switch. Finally, the validity of the theoretical analyses for the proposed converter is verified by both simulations and experiments on the 10[W] class isolated boost converter.

A Packet Control method of Interconnection between IBM NP4GS3 DASL and CSIX Interface (IBM NP4GS3 DASL인터페이스와 CSIX-Ll인터페이스의 연동구조 및 패킷 제어방안)

  • 김광옥;최창식;박완기;최병철;곽동용
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.4
    • /
    • pp.10-21
    • /
    • 2003
  • Recently, the optical subscriber interface module uses the high performance network processor to quickly develop new application services such as MPLS, VPN, RPR and EPON with a short time-to-market. Although a number of vendors are developing the network processor at 2.5Gbps, only the IBM NP4GS3 can provide packet processing with wire-speed at 2.5Gbps. IBM NP4GS3, however, uses its unique speed DASL interface instead of CSIX-Ll interface, which has standardized by M: Forum currently Therefore, we implement an interconnection mechanism to use the switch fabric with CSIX-Ll interface. In this paper, we suggest the architecture and a packet control mechanism supporting interconnection between IBM NP4GS3 DASL and CSIX-Ll switch interface using the common IBM UDASL ASIC and XILINX FPGA.