• Title/Summary/Keyword: Switch-control

Search Result 1,253, Processing Time 0.031 seconds

Audit Method Design and Performance Evaluation for Connection Information in ATM Switch (ATM 교환기에서 연결 정보에 대한 감사 기능 제공 방안 및 성능 평가)

  • 유영일;전병실
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.11
    • /
    • pp.27-33
    • /
    • 2003
  • This paper proposes the efficient audit method for the distributed connection information in ATM switch. Based on this method, we design the periodic audit function by a system and immediate audit function by a operator's order. We evaluate the performance about the proposed Audit method. At the result of evaluation, We figure out that the load of call control processor is almost independent of a system load regardless of audit function operation. Therefore, we confirm that the proposed audit method nearly have an effect on the load of call control processor. The proposed audit method can reestablish a Mismatched connection information with a little load.

Analytic Model of Four-switch Inverter-fed Driving System for Wye or Delta-connected Motor with Current Ripple Reduction Scheme

  • Lee, Dong-Myung;Jung, Jin-Woo;Heo, Seo Weon;Kim, Tae Heoung
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.109-116
    • /
    • 2016
  • This paper proposes an analytic model for four-switch inverter (FSI)-driven wye (Y) or delta (Δ)-connected motors with a current ripple reduction algorithm. FSIs employ four switches in controlling three-phase load instead of using six switches. They have split dc-link stage, and due to this inherent structure there exists the voltage difference between upper and lower capacitors, which results in distortion of the inverter output voltage. To study characteristics of FSIs, this paper presents an advanced simulation models of FSI-driven control system for 3-phase motor that can has a wire connection either Y or Δ. In addition, this paper introduces a current ripple reduction scheme that mitigates degradation of control performance due to the voltage difference between the dc-link capacitors. The validity of the proposed method and the analytic model is verified by simulations and experiments carried out with 1-HP induction machine with Y or Δ-connection

A Study on Performance Improvement of Hybrid Energy Storage System for Mild HEV (마일드 하이브리드 차량용 복합형 에너지 저장장치의 성능개선에 관한 연구)

  • Lee, Back-Haeng;Shin, Dong-Hyun;Kim, Hee-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1763-1769
    • /
    • 2007
  • To improve the cycle-life and efficiency of an energy storage system for HEV, a dynamic control system consisted of a switch between a battery and an ultracapacitor module is proposed, which is appropriate for mild hybrid vehicle with 42V power net. The switch can be controlled based on the status of the battery and the ultracapacitor module, and a control algorithm that could largely decrease the number of high charging current peak is also implemented. Therefore the cycle life of the battery can be improved such that it is suitable for a mild hybrid vehicle with frequent engine start-stop and regenerative-braking. Also, by maximizing the use of the ultracapacitor, the system efficiency during high current charging and discharging operation is improved. Finally, this system has the effects that improves the efficiency of energy storage system and reduces the fuel consumption of a vehicle. To verify the validity of the proposed system, this paper presented cycles test results of different energy storage systems: a simple VRLA battery, hybrid energy Pack (HEP, a VRLA battery in Parallel with Ultracapacitor) and a HEP with a switch that controlled by energy management system (EMS). From the experimental result, it was proved the effectiveness of the algorithm.

Investigation of Low-Frequency Characteristics of Four-Switch Three-Phase Inverter

  • Yuan, Qingwei;Cheng, Chong;Zhao, Rongxiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1471-1483
    • /
    • 2017
  • The low-frequency characteristics of four-switch three-phase (FSTP) inverter are investigated in this paper. Firstly, a general space vector pulse width modulation (SVPWM) directly involved the neutral point voltage of DC-link is proposed, where no sector identifications and trigonometric function calculations are needed. Subsequently, to suppress the DC offset in the neutral point voltage, the relationship between the neutral point voltage and the ${\beta}-axis$ component of the load current is derived, and then a new neutral point voltage control scheme is proposed where no low pass filter is adopted. Finally, the relationship between the load power factor and the maximum linear modulation index of the FSTP inverter is revealed. Since the operational region for the FSTP inverter in low frequency is reduced by the enlarged amplitude of the neutral point voltage, a linear modulation range enlargement scheme is proposed. A permanent magnet synchronous motor with preset rotary speed serves as the low-frequency load of the FSTP inverter. Experimental results verify that the new neutral point voltage control scheme is effective in the deviation suppression of the neutral point voltage, and the proposed scheme is able to provide a larger linear operational region in low frequency.

Development of Smart Laundry Drying System

  • Kim, Nuri;Lim, Huhnkuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.3
    • /
    • pp.99-104
    • /
    • 2022
  • In this paper, we first intend to develop and introduce a smart laundry drying system for verandas that controls the drying rack by actively responding to climate change. The developed smart laundry drying system receives laundry location information through the app, then detects climate change in real time through data from the Korea Meteorological Administration such as temperature and humidity according to the location information, and automatically controls the laundry on the drying rack in case of rain. It acquires weather information through the Arduino humidity sensor and the Korea Meteorological Administration Open-API, which is used to control the switch bot by the Raspberry Pi. The user interface uses Blynk, and the switch bot controls the laundry. Our proposed system can detect bad weather and automatically control the laundry at a remote location to prevent damage to the laundry.

BLDC Motor Drive using C-dump Converter (C-dump 컨버터를 이용한 BLDC 전동기 구동)

  • Sungin Jeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.139-144
    • /
    • 2023
  • In order to obtain the maximum characteristics of motors such as torque and efficiency, all motors basically use universal inverters designed for each motor's characteristics. However, if you look at the recent research results, you can see cases of SRM(Switched Reluctance Motor) driving studies using 6-switch inverters, which are BLDC(Brushless DC Motor) universal inverters, and research cases of driving 3-phase BLDC motors using 4-switch inverters. Therefore, it is possible to search for research methods by approaching various methods of driving and control that can drive each motor apart from the existing universal inverter. In line with this research trend, in this paper, a C-dump type converter, which is an SRM drive converter, was applied as a drive driver for a BLDC motor, and its characteristics and possibilities were studied.

Control System Design of Electric Operated Adjustable Bed for Body Posture Stability (체간 안정성을 위한 전동침대의 제어시스템 설계)

  • Bae, J.H.;Moon, I.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.2
    • /
    • pp.55-62
    • /
    • 2012
  • In this paper we propose a control system to preserve the interior angle between back section and upper leg section to be larger than 90 degrees using a single limit switch. To design the control system we analyze the kinematics of actuation mechanisms for the back section and the upper leg section, and find out an optimal solution for the controller design. Using a prototype control system we perform experiments to test the controller performance, and show that the interior angle between the back section and the upper leg section is always preserved larger than 90 degree. From the experimental results, we show the proposed control system is feasible to keep the body posture stability.

  • PDF

Speech Recognition System in Car Noise Environment (자동차 잡음환경에서의 음성인식시스템)

  • Kim, Soo-Hoon;Ahn, Jong-Young
    • Journal of Digital Contents Society
    • /
    • v.10 no.1
    • /
    • pp.121-127
    • /
    • 2009
  • The automotive ECU(Electronic Control Unit) becomes more complicated and is demanding many functions. For example, many automobile companies are developing driver convenience systems such as power window switch, LCM(Light Control Module), mirror control system, seat memory. In addition, many researches and developments for DIS(Driver Information System) are in progress. It is dangerous to operate such systems in driving. In this paper, we implement the speech recognition system which controls the car convenience system using speech, and apply the preprocessing filter to improve the speech recognition rate in car noise environment. As a result, we get the good speech recognition rate in car noise environment.

  • PDF

ABR Traffic Control Using Feedback Information and Algorithm

  • Lee, Kwang-Ok;Son, Young-Su;Kim, Hyeon-ju;Bae, Sang-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.11a
    • /
    • pp.236-242
    • /
    • 2003
  • ATM ABR service controls network traffic using feedback information on the network congestion situation in order to guarantee the demanded service qualities and the available cell rates. In this paper we apply the control method using queue length prediction to the formation of feedback information for more efficient ABR traffic control. If backward node receive the longer delayed feedback information on the impending congestion, the switch can be already congested from the uncontrolled arriving traffic and the fluctuation of queue length can be inefficiently high in the continuing time intervals. The feedback control method proposed in this paper predicts the queue length in the switch using the slope of queue length prediction function and queue length changes in time-series. The predicted congestion information is backward to the node. NLMS and neural network are used as the predictive control functions, and they are compared from performance on the queue length prediction. Simulation results show the efficiency of the proposed method compared to the feedback control method without the prediction. Therefore, we conclude that the efficient congestion and stability of the queue length controls are possible using the prediction scheme that can resolve the problems caused from the longer delays of the feedback information.

  • PDF

Approach towards qualification of TCP/IP network components of PFBR

  • Aditya Gour;Tom Mathews;R.P. Behera
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.3975-3984
    • /
    • 2022
  • Distributed control system architecture is adopted for I&C systems of Prototype Fast Breeder Reactor, where the geographically distributed control systems are connected to centralized servers & display stations via switched Ethernet networks. TCP/IP communication plays a significant role in the successful operations of this architecture. The communication tasks at control nodes are taken care by TCP/IP offload modules; local area switched network is realized using layer-2/3 switches, which are finally connected to network interfaces of centralized servers & display stations. Safety, security, reliability, and fault tolerance of control systems used for safety-related applications of nuclear power plants is ensured by indigenous design and qualification as per guidelines laid down by regulatory authorities. In the case of commercially available components, appropriate suitability analysis is required for getting the operation clearances from regulatory authorities. This paper details the proposed approach for the suitability analysis of TCP/IP communication nodes, including control systems at the field, network switches, and servers/display stations. Development of test platform using commercially available tools and diagnostics software engineered for control nodes/display stations are described. Each TCP link behavior with impaired packets and multiple traffic loads is described, followed by benchmarking of the network switch's routing characteristics and security features.