• Title/Summary/Keyword: Switch reduced inverter

Search Result 62, Processing Time 0.023 seconds

Soft Switching Control Method for Photovoltaic AC Module Flyback Inverter using Synchronous Rectifier (동기 정류기를 이용한 태양광 모듈용 플라이백 인버터 소프트 스위칭 제어 기법)

  • Jang, Jin-Woo;Kim, Young-Ho;Choi, Bong-Yeon;Jung, Yong-Chae;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.312-321
    • /
    • 2013
  • In this paper, high efficiency control method for flyback inverter with synchronous rectifier(SR) based on photovoltaic AC modules is proposed. In this control method, the operation of SR is classified according to the voltage spike across main switch SP. When the voltage spike across SP is lower than the rating voltage of SP, the operation of active clamp circuit is interrupted for reducing the switching loss of auxiliary switch. In this time, the SR is operated for soft-switching of SP. When the voltage spike across Sp is higher than the rating voltage of SP, the operation of active circuit is activated for reducing the voltage spike. The SR is operated for reducing the conduction loss of secondary output diode. Thus, a switching loss of the main switch can be reduced in low power region, and weighted-efficiency can be improved. A theoretical analysis and the design principle of the proposed method are provided. And validity is confirmed through simulation and experimental results.

DC Rail Side Series Switch and Parallel Capacitor Snubber-Assisted Edge Resonant Soft-Switching PWM DC-DC Converter with High-Frequency Transformer Link

  • Morimoto, Keiki;Fathy, Khairy;Ogiwara, Hiroyuki;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.181-190
    • /
    • 2007
  • This paper presents a novel circuit topology of a DC bus line series switch and parallel snubbing capacitor-assisted soft-switching PWM full-bridge inverter type DC-DC power converter with a high frequency planar transformer link, which is newly developed for high performance arc welding machines in industry. The proposed DC-DC power converter circuit is based upon a voltage source-fed H type full-bridge soft-switching PWM inverter with a high frequency transformer. This DC-DC power converter has a single power semiconductor switching device in series with an input DC low side rail and loss less snubbing capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge arms and DC bus line can achieve ZCS turn-on and ZVS turn-off transition commutation. Consequently, the total switching power losses occurred at turn-off switching transition of these power semiconductor devices; IGBTs can be reduced even in higher switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules can be realized at 60 kHz. It is proved experimentally by power loss analysis that the more the switching frequency increases, the more the proposed DC-DC power converter can achieve a higher control response performance and size miniaturization. The practical and inherent effectiveness of the new DC-DC converter topology proposed here is actually confirmed for low voltage and large current DC-DC power supplies (32V, 300A) for TIG arc welding applications in industry.

A New Low-Cost Active Power Filter to Suppress Neutral Current Harmonics in Three-Phase Four-Wire System (3상 4선식 배전계통에서 중성선 전류 제거를 위한 새로운 저가형 능동전력필터)

  • 장민수;최세완;김기영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.359-365
    • /
    • 2002
  • Three-phase four-wire electrical distribution systems have been widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads, the neutral conductor carries excessive harmonic currents resulting in wiring failure of the neutral conductor, overloading of the distribution transformer and a voltage drop between the neutral and the ground. This paper proposes a reduced rating active power filter to suppress neutral current harmonics in three-phase four-wire electrical distribution systems. The proposed system is simple in control and the VA rating of the inverter could be significantly reduced since only the fundamental current due to unbalanced loading flows through the inverter switch. The experimental results on a prototype validate the proposed control approach.

Design of Domestic Induction Cooker based on Optimal Operation Class-E Inverter with Parallel Load Network under Large-Signal Excitation

  • Charoenwiangnuea, Patipong;Ekkaravarodome, Chainarin;Boonyaroonate, Itsda;Thounthong, Phatiphat;Jirasereeamornkul, Kamon
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.892-904
    • /
    • 2017
  • A design of a Class-E inverter with only one inductor and one capacitor is presented. It is operated at the optimal operation mode for domestic cooker. The design principle is based on the zero-voltage derivative switching (ZVDS) of the Class-E inverter with a parallel load network, which is a parallel resonant equivalent circuit. An induction load characterization is obtained from a large-signal excitation test bench, which is the key to an accurate design of the induction cooker system. Consequently, the proposed scheme provides a more systematic, simple, accurate, and feasible solution than the conventional quasi-resonant inverter analysis based on series load network methodology. The derivative of the switch voltage is zero at the turn-on transition, and its absolute value is relatively small at the turn-off transition. Switching losses and noise are reduced. The parameters of the ZVDS Class-E inverter for the domestic induction cooker must be selected properly, and details of the design of the components of this Class-E inverter need to be addressed. A 1,200 W prototype is designed and evaluated to verify the validation of the proposed topology.

A High-efficiency Buck-boost Half-bridge Inverter for Single-phase Photovoltaic Generation (단상 태양광 발전용 고효율 벅부스트 하프브리지 인버터)

  • Hyung-Min Ryu
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.450-455
    • /
    • 2023
  • Among single-phase photovoltaic inverters that can avoid excessive leakage current caused by the large parasitic capacitance of photovoltaic panels, a boost converter followed by a half-bridge inverter is the simplest and has the smallest leakage current. However, due to the high DC-link voltage, the rated voltage of the switching devices is high and the switching loss is large. This paper proposes a new circuit topology which can operate as a buck-boost inverter by adding two bidirectional switches to the output side of the half-bridge inverter instead of removing the boost converter. By reducing two stages of power conversion through the high-voltage DC-link to one stage, power loss can be reduced without increasing costs and leakage current. The feasibility of the proposed circuit topology is verified by computer simulation and power loss calculation.

Switch Open Fault Detection and Tolerant Operation Method for Three Phase PWM Rectifier (3상 PWM 정류기의 스위치 개방 고장 감지 및 허용운전 방법)

  • Shin, Hee-Keun;An, Byoung-Woong;Kim, Hag-Wone;Cho, Kwan-Yuhl;Jung, Shin-Myung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.266-273
    • /
    • 2012
  • In this paper, the new open fault detection and tolerant operation method for 3 phase PWM rectifier is proposed. When open fault occurred on the inverter switches of 3 Phase PWM rectifier, the DC link voltage ripple is increased because the input current of the faulty phase is distorted. In this case, the quality of electric power would decrease, and the life time of DC link capacitor is decreased. The open fault is detected by a simple MRAS(Model Reference Adaptive System) without additional hardware sensors, and the tolerant operation carried out by turning on the opposite switch of the faulty switch without any redundancy. By the proposed method, the faulty phase input current can be controlled, so that 3-phase input current is balanced relatively under the faulty condition and the voltage ripple of DC link output is reduced. The validity of the proposed technique is proved on the 6kW 3-phase PWM rectifier system by simulation and experiment.

A Novel Soft-Switching PWM DC/DC Converter with DC Rail Series Switch-Parallel Capacitor Edge Resonant Snubber Assisted by High-Frequency Transformer Parasitic Components

  • Fathy, Khairy;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.377-382
    • /
    • 2005
  • This paper presents two new circuit topologies of DC bus lineside active edge resonant snubber assisted soft-switching PWM full-bridge DC-DC converter acceptable for either utility AC 200V-rms or AC 400V-rms input voltage source. One topology of proposed DC-DC converters is composed of a typical voltage source-fed full-bridge high frequency PWM inverter using DC busline side series power semiconductor switching devices with the aid of a parallel capacitive lossless snubber. All the active power switches in the full-bridge arms and DC busline can achieve ZCS turn-on and ZVS turn-off commutations and the total turn-off switching power losses of all active switches can be reduced for high-frequency switching action. It is proved that the more the switching frequency of full-bridge soft switching inverter increases, the more soft-switching PWM DC-DC converter with a hish frequency transformer link has remarkable advantages for its efficiency and power density as compared with the conventional hard-switching PWM inverter type DC-DC converter

  • PDF

Comparison of Battery Charging Strategies for PHEVs using Propulsion Motor Inductance and Multi-Function Inverter (인덕터 및 모터 인덕턴스를 이용한 PHEV 배터리 충전 기법 비교 분석)

  • Woo, Dong-Gyun;Choe, Gyu-Yeong;Kim, Jong-Soo;Lee, Byoung-Kuk;Kang, Gu-Bae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.326-333
    • /
    • 2011
  • This paper studies battery charging methods using existing motor inductance and 3-phase inverters without an additional charger to charge the battery of Plug-in Hybrid Electric Vehicles (PHEVs). As inverter switch control and motor coil used as the energy storage device for boosting make the system the boost converter, the additional charger is eliminated and volume, weight, and cost for the charger are reduced. Various charging methods according to topologies of the system and configurations of the controller are analyzed and verified by PSIM simulation.

A Single-Phase Hybrid Multi-Level Converter with Less Number of Components

  • Kim, Ki-Mok;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.105-107
    • /
    • 2018
  • This paper presents a new hybrid multilevel converter topology, which consists of a combination of the series connected switched capacitor units with boost ability, and an H-bridge with T-type bidirectional switches. The proposed converter boosts the input voltage without any bulky inductors, and has the small number of components, which can make the size and cost of a power converter greatly reduced. The output filter size and harmonics are also reduced by the high quality multilevel output. In addition, there is no need for complicated methods to balance the capacitor voltage. Simulation and experimental results with a nine-level converter system are presented to validate the proposed topology and modulation method.

  • PDF

Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter (고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수)

  • Kim, Kwang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.35-43
    • /
    • 2005
  • Matrix converters have been studied for eliminating dc link of conventional converter-inverter system, and various undulation strategy have been proposed. Therefore, matrix converter have no energy storage component except for small ac later for the elimination of switching ripple, and can be made compact and highly reliable compare with the do link inverter system. Matrix converter, however, directly connected the input and the output terminals by bidirectional static switch. As a result if the input voltage are asymmetrical, and contain harmonics, the influence of the distortions directly appear on the output terminal. This problem is a major obstacle to the matrix converter. A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current unity input displacement factor regardless of load power factor. Moreover, compensation of the asymmetrical and/or harmonic containing input voltage is automatically realized, and calculation time of control function is reduced.