• Title/Summary/Keyword: Switch Function

Search Result 344, Processing Time 0.023 seconds

Static Switch Control of UPS with Active Filter Function (능동 필터 기능을 갖는 무정전전원장치의 정적 스위치 제어)

  • Hong, Hyun-Mun;Jeon, B.S.;Kim, J.G.;Lee, S.H.;Kim, J.S.;Min, Y.G.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.406-408
    • /
    • 2005
  • In this literature, when the utility line is normal, the Off-Line UPS operates as an active power filter to compensate the reactive power from a load, and when the utility line is in outage, the On-Line UPS opuates as in single phase inverter to supply an active and reactive power to the load. An additional static switch in UPS was used to decrease an transient state during these mode changes. And the result shows that the transient state disappeared.

  • PDF

PWM Switch Modelling of Boost Converter for Photovoltaic System (PWM 스윗치를 이용한 햇빛발전 시스템용 부스트 컨버터 모델링)

  • Kim, H.J.;Choi, J.Y.;Yu, G.J.;Jung, Y.S.;Choi, I.;Ahan, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.341-348
    • /
    • 2003
  • Photovoltaic systems normally use a maximum power point tracking (MPPT) technique ta continuously deliver the highest possible power to the load when variations in the insolation and temperature occur. A simple method of tracking the maximum power points (MPPs) and forcing the boost converter system to operate close to these points is presented through deriving small-signal model and transfer function of boost converter. This paper aims at modeling boost converter including equivalent series resistance of input reservoir capacitor by state-space-averaging method and PWM switch model with properly designed controller for maximum photovoltaic power tracking control.

  • PDF

Development of Monitoring Tool for Small SMP Cluster System (소규모 SMP 클러스터 시스템 모니터링 개발)

  • Sung, JinWoo;Lee, YoungJoo;Choi, YounKeun;Park, ChanYeol
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.535-538
    • /
    • 2007
  • System manager needs monitoring tool(S/W) to manage cluster system. But, it is difficult to decide suitable monitoring tool for small SMP cluster system. This document described design of monitoring tool(mon) and development. Mon is monitoring tool for small SMP cluster system using InfiniBand network switch. Function of this tool is monitoring such as computing node(7 node), Infiniband network switch and monitoring of PBS job.

  • PDF

A Force/Moment Direction Sensor and Its Application in Intuitive Robot Teaching Task

  • Park, Myoung-Hwan;Kim, Sung-Joo
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.3 no.4
    • /
    • pp.236-241
    • /
    • 2001
  • Teach pendant is the most widely used means of robot teaching at present. Despite the difficulties of using the motion command buttons on the teach pendant, it is an economical, robust, and effective device for robot teaching task. This paper presents the development of a force/moment direction sensor named COSMO that can improve the teach pendant based robot teaching. Robot teaching experiment of a six axis commercial robot using the sensor is described where operator holds the sensor with a hand, and move the robot by pushing, pulling, and twisting the sensor in the direction of the desired motion. No prior knowledge of the coordinate system is required. The function of the COSMO sensor is to detect the presence f force and moment along the principal axes of the sensor coordinate system. The transducer used in the sensor is micro-switch, and this intuitive robot teaching can be implemented at a very low cost.

  • PDF

Rapid Left ventricular Training after Arterial Switch Operation in Transposition of Great Arteries with Left Ventricular Outflow Tract Obstruction and ventricular Septal Defect -1 case report- (심실 중격 결손과 좌심실 유출로 협착을 동반한 대혈관 전위 -동맥 전활술후 좌심실의 트레이닝 1례-)

  • 조준용;김웅한;김수진;전양빈
    • Journal of Chest Surgery
    • /
    • v.33 no.3
    • /
    • pp.252-256
    • /
    • 2000
  • There have been few reports documenting the outcome of arterial swich operations(ASO) in selected patients with transposition of great arteries(TGA) and with left ventricular outflow tract obstruction(LVOTO). In the case of TGA with LVOTO, if the atrial septal defect(ASD) is large and the ventricular septal defect(VSD) is restricive, this deprives the left ventricle(LV) of approporiate preload and could lead to underdevelopment of the ventircular mass and lead poor LV performance after the arterial switch operation, dspite a high pressure in the LV preoperatively. Because an increase in the systolic ventricular pressure is not necessarily paralleled by an increase in ventricular mass, which is also essential for optimal ventricular performance after the operation. We report here a case of rapid LV training after ASO in TGA with unprepared LV (because of large ASD and restrictive VSD) despite a high pressure in the LV(due to LVOTO) preoperatively.

  • PDF

Boost Converter Modeling of Photovoltaic System Using PWM Switch Model (PWM 스윗치 모델을 이용한 PV용 Boost Converter Modelling)

  • Kim, H.J.;Lee, K.O.;Choi, J.Y.;Jung, Y.S.;Yu, G.J.;Kwon, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.286-293
    • /
    • 2002
  • Photovoltaic systems normally use a maximum power point tracking (MPPT) technique to continuously deliver the highest possible power to the load when variations in the insolation and temperature occur. A simple method of tracking the maximum power points (MPPs) and forcing the boost converter system to operate close to these Points is presented through deriving small-signal model and transfer function of boost converter. This paper aims at modeling boost converter including equivalent series resistance of input reservoir capacitor by state-space-averaging method and PWM switch model. In the future, properly designed controller for compensation will be constructed in real system for maximum photovoltaic power tracking control.

  • PDF

A Simulation Study on the Number of Operators of Automobile Relay Switch Production (자동차 릴레이스 위치 생산공정의 작업자수 선정을 위한 시뮬레이션 연구)

  • 김원경
    • Journal of the Korea Society for Simulation
    • /
    • v.11 no.3
    • /
    • pp.67-77
    • /
    • 2002
  • In this paper, a production process system simulation of the automobile relay switch manufacturing factory is studied. The status of the present production system is inspected first, and the modified model is simulated next. To inspect the effect of the process parameter change, a simulation program is developed using PROMODEL simulation software plus the EXCEL VBA and Active X Automation function. Using the developed simulation program, user can find the best production condition and alternatives on the production capacity, number of workers, and inspection status considering the defective ratio of the product. The feasibility of the new alternatives is compared with the present system using statistical method.

  • PDF

Operation characteristics of fast pulse generator using a 2-stage magnetic switch (2단 자기스위치를 사용한 고속 펄스발생기의 동작 특성)

  • 김복권;권순걸;서기영;이현우
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.10
    • /
    • pp.139-147
    • /
    • 1996
  • In this study a two-stage fast pulse generaor using magnetic switches is proposed. The scheme consist of a switch, an inductor and two pairs of capacitor and saturable inductors, a linear transformer. The basic principle and the operation are described using a set of given parameters. The main issue of the magnetic pulse genration scheme is the system efficiency. This study focuses on the system efficiency improvement using magnetic switches. The voltage compression ratio, energy transfer with respect to core area are investigated. The output voltage and transferred energy as a function of input voltage are also included. Also, an analysis and experiments are performed to verify the porposed topology by implementing a 10[J] class experimental circuit. The efficiency of the transferred energy a tload side is 82%.

  • PDF

Novel Compact Current Type Pulse Power Generator

  • Min, B.D.;Kim, J.H.;Pavlov, E.;Yoo, D.W.;Rim, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.529-531
    • /
    • 2005
  • This paper proposes a compact pulse generator fur NOx removal application for diesel automotive. The rising time is important factor to increase NOx removal efficiency in pulsed corona discharge method. Manufacturing cost and compactness of the pulse power generator should be satisfied for automotive application. The proposed pulse power uses a low voltage thyristor, a pulse transformer with the function of saturated magnetic switch, and series connected general diodes as opening switch to satisfy that requirements. With 200 resistor load, the experiment results show that the output voltage is 21kV, the rising time is about 21ns, and the pulse width (FWHM) is about 42ns.

  • PDF

Converter Utilization Ratio Enhancement in the THD Optimization of Cascaded H-Bridge 7-level Inverters

  • Khamooshi, Reza;Namadmalan, Alireza;Moghani, Javad Shokrollahi
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.173-181
    • /
    • 2016
  • In this paper, a new technique for harmonic optimization in cascaded H-bridge 7-level inverters is proposed. The suggested strategy is based on minimizing an objective function which simultaneously optimizes the converter utilization and Total Harmonic Distortion (THD). The Switch Utilization Ratio (SUR) is formulized for both the phase and line-line voltages of a 7-level inverter and is considered in the final objective functions. Based upon the SUR formula, utilization ratio enhancement will reduce the value of feeding DC links, which improves the efficiency and lifetime of the circuit components due to lower voltage stresses and losses. In order to achieve more effective solution in different modulation indices, it is assumed that the DC sources can be altered. Experimental validation is presented based on a three-phase 7-level inverter prototype.