• Title/Summary/Keyword: Switch Fault

Search Result 186, Processing Time 0.027 seconds

Reliability analysis of the switch installation in the main feeder and in the radial/loop lateral feeders in distribution system (간선 및 분기선의 개폐기 설치 효과 분석(I))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.79-82
    • /
    • 2002
  • The addition of switches to a distribution feeder does, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder. To cover its service area so that feeder-level delivery reaches sufficiently close to all customers, feeders typically split their routes many times, in what is often called a lateral feeder. It is interesting to note, however, that the effectiveness of a switch is very much dependent on the types of lateral feeder. The types of lateral are classified into two types. The first is loop lateral feeder that can connect its load to an adjacent feeder through a tie line in case that a fault occurs in its feeder and it is laid out so that every feeder has complete fault backup through re-switching of its loads to other sources like a main feeder. The second is the radial lateral feeder cannot connect its load to an adjacent line, no provision is made for contingency backup of feeders. There are no other circuits in the radial lateral feeder form which to restore power. In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

  • PDF

Case Study of Intermittent Poor Acceleration Fault Diagnosis by Brake Switch Fault (브레이크 스위치 결함에 의한 간헐적인 가속불량 현상의 고장진단 사례연구)

  • Kim, Sung Mo;Jo, Haeng Deug
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.2
    • /
    • pp.203-210
    • /
    • 2015
  • This paper investigates the failure of a car with a 2.5-liter CRDi engine of the Hyundai Company. The failure is caused by intermittent poor acceleration while driving. To analyze the cause, we investigated the air intake volume, the fuel injection, and the air-fuel ratio, which were determined to be normal. The brake switch signal error was discovered while analyzing the function that limits the output of the engine. While investigating the cause, we discovered the corrosion of the pins on the connector of the brake switch. We determined that it was generated by soapy water flowing in the solar film. Therefore, the cause of the failure was the brake switch signal errors. Additionally, we determined that ECM was the normal fail-safe mode that implemented the override device for safety during normal acceleration. Based on these results, further solar film experiments must be conducted to fully elucidate the causes.

The Development of ASS Controller Using DSP (DSP를 이용한 자동고장구분개폐기의 제어장치 개발)

  • Woo, Chun-Hee;Han, Tae-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.3
    • /
    • pp.142-147
    • /
    • 2004
  • In this study, We developed the microprocessor based controller for Auto Section Switch(ASS). This is installed at consumer's medium-high voltage(load capacity is below 4,000 kVA) switchgear. This function is cooperate with protection device of fault section and automatically dividing the section. And It is designed by Air putter type extinction structure and adopt the mechanism and breaking part module of existing Load Breaker Switch. In addition, We successfully conducted the operation test and checked main function of proto-type.

Fault Detection of BLDC Motor Drive Based on Operating Characteristic (BLDC 전동기 운전 특성을 이용한 고장 검출 기법 구현)

  • Lee, Jung-Dae;Park, Byoung-Gun;Kim, Tae-Sung;Ryu, Ji-Su;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.88-95
    • /
    • 2008
  • This paper proposes a fast fault detection algorithm under open-circuit fault of a switch for a brushless DC(BLDC) motor drive system. This proposed method is configured without the additional devices for fault detection and identification. The fault detection and identification are achieved by a simple algorithm using the operating characteristic of the BLDC motor. After the fault identification, the drive system is reconfigured for continuous operation. This system is reconfigured by four-switch topology connecting a faulty leg to the middle point of DC-link bidirectional switches. This proposed method can also be embedded into existing BLDC motor drive systems as a subroutine without excessive computational effort. The feasibility of a the proposed fault detection algorithm is validated in simulation and experiment.

Improvement and Application Effect in Fault Restoration Program based on Distribution Automation System of KEPCO (한전의 배전자동화 기반 배전선로 고장처리 프로그램 개선 및 적용 효과)

  • Park, So-Young;Shin, Chang-Hoon;Ha, Bok-Nam;Lee, Seong-Woo;Park, Min-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.267-271
    • /
    • 2009
  • This paper presents the improvement and application effect in fault restoration program based on distribution automation system(DAS) of KEPCO. When a fault occurs, fault restoration program can detect fault section based on FI information of DAS, and calculate the best restoration solution by comparing the load capacity of outage area and the spare load capacity of connected distribution lines, and propose switch operating procedure for fault section isolation and outage restoration. Fault restoration program was applied to real field and it was verified that this program is applicable to diverse field cases. By using this fault restoration program to the field human error can be reduced and fault procedure can be more reliable, accurate, and fast.

  • PDF

Optical Network Monitoring System Using Smart Phone (스마트 폰을 이용한 광 통신망 감시 시스템)

  • Jung, So-Ki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.1
    • /
    • pp.218-226
    • /
    • 2017
  • In this paper, optical transport network in real time monitoring system using smart phone. The existing housing using monitoring was a smart phone of optical transport network access switch about an event with new installation of cognitive system in real time. This paper can this problem to be solved of the invention in real time maintenance using smart phone application and optical cable closure switch. If you want to find optical cable closure fault location, this smart phone web is very useful. Cable tie is isolation of fiber spare board from fiber switch tie occur push message. Housing and access, and an external failures otdr the measurement of the global positioning to be able to easily using the This paper can find event of optical cable closure unauthorized work and fault using smart phone OTDR function. the optical cable fault time reduction and network transport quality by managing real time optical cable section by using the smart phone can be maintained efficiently.

Performance evaluation of the input and output buffered knockout switch

  • Suh, Jae-Joon;Jun, Chi-Hyuck;Kim, Young-Si
    • Korean Management Science Review
    • /
    • v.10 no.1
    • /
    • pp.139-156
    • /
    • 1993
  • Various ATM switches have been proposed since Asynchronous Transfer Mode (ATM) was recognized as appropriate for implementing broadband integrated services digital network (BISDN). An ATM switching network may be evaluated on two sides : traffic performances (maximum throughput, delay, and packet loss probability, etc.) and structural features (complexity, i.e. the number of switch elements necessary to construct the same size switching network, maintenance, modularity, and fault tolerance, etc.). ATM switching networks proposed to date tend to show the contrary characteristics between structural features and traffic performance. The Knockout Switch, which is well known as one of ATM switches, shows a good traffic performance but it needs so many switch elements and buffers. In this paper, we propose an input and output buffered Knockout Switch for the purpose of reducing the number of switch elements and buffers of the existing Knockout Switch. We analyze the traffic performance and the structural features of the proposed switching architecture through a discrete time Markov chain and compare with those of the existing Knockout Switch. It was found that the proposed architecture could reduce more than 40 percent of switch elements and more than 30 percent of buffers under a given requirement of cell loss probability of the switch.

  • PDF

Analysis on the Protective Coordination with Hybrid Superconducting Fault Current Limiter (반주기 이후 동작 하이브리드 초전도 전류제한기와 보호기기 협조 분석)

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul;Choi, Jong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1832-1837
    • /
    • 2011
  • The fault current has increased due to the large power demand in power distribution system and network distribution system. To protect the power system effectively from the increased fault current, the superconducting fault current limiter (SFCL) has been notified. However, the conventional SFCL has some problems such as cost, operation, recovery, loss. To solve some problems, the hybrid superconducting fault current limiter using the fast switch was proposed. However, hybrid SFCL also has a problem that is protection coordination in power distribution system with hybrid SFCL. In this paper, the fault current limiting characteristics of hybrid SFCL with first half cycle non-limiting operation according to the fault angle, the resistance of superconducting element, and the magnitude of Current Limit Resistor (CLR) which are the components of hybrid SFCL were analyzed through the experiments.

Open Circuit Fault Diagnosis Using Stator Resistance Variation for Permanent Magnet Synchronous Motor Drives

  • Park, Byoung-Gun;Kim, Rae-Young;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.985-990
    • /
    • 2013
  • This paper proposes a novel fault diagnosis scheme using parameter estimation of the stator resistance, especially in the case of the open-phase faults of PMSM drives. The stator resistance of PMSMs can be estimated by the recursive least square (RLS) algorithm in real time. Fault diagnosis is achieved by analyzing the estimated stator resistance of each phase according to the fault condition. The proposed fault diagnosis scheme is implemented without any extra devices. Moreover, the estimated parameter information can be used to improve the control performance. The feasibility of the proposed fault diagnosis scheme is verified by simulation and experimental results.

Interface design Between AMR and DAS (자동 원격검침시스템과 DAS의 연계)

  • Jeong, Jeom-Su;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.47-51
    • /
    • 2008
  • Computer and communication of based IT technology use to das that remote control, monitoring, measuring automation gas switch, recloser totaled far about $20{\sim}30km$. For increasing efficiency billing, metering of high voltage customer use to amr system. If between das and amr interface operate when generated fault in high voltage electric equipment of customer part, amr system serve to das quickly in fault information data, correct fault location.

  • PDF