• Title/Summary/Keyword: Switch Control Unit

Search Result 81, Processing Time 0.032 seconds

A Study on the Signal Control Unit's Reconstitution to Control the Separated Through/Left(or Right) Turn and the Median Bus Lane Signal for the Standard Traffic Signal Controller (표준규격 교통신호제어기에서 교통류별 전용신호 구현방안 연구)

  • Han, Won-Sub;Lee, Ho-Won;Hyun, Cheol-Seung;Joo, Doo-Hwan;Lee, Choul-Ki
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.5
    • /
    • pp.57-70
    • /
    • 2009
  • According to the change of the traffic conditions, the requirement of controlling the separated left(or right) turn, the median bus lane and bicycle signal is increasing. However, the traffic signal controller standard based on the four-set lights restricts to control the three-set lights which control the separated direction and kind of traffics. This study suggests the method to control the three-set lights signal by improving the hardware and software for the traffic signal controller which is operated currently in the traffic scene. The 6 output ports of Load Signal Unit(LSU) which is consisted of Pedestrian Red, Pedestrian Green, Red, Yellow, Arrow and Green signal reconstitute 2 rows of the Red, Yellow, Green for three-set lights while the Signal Map data's code values which control the signal step of an individual Ring and LSU are established to adjust the LSU's output ports(R1 Y1 G1 R2 Y2 G2) of the three-set lights. The effect of using the separated through/left turn and the median lane bus signal of three-set lights is analyzed from a Mangwoo intersection in Seoul. The results of analysis show that the delay time of the east-west direction where the median bus lane is operated is especially improved with over 70 sec/veh.

  • PDF

Bidirectional dc-to-dc Converter Employing Dual Inductor for Current Ripple Reduction (전류 리플 저감을 위한 듀얼 인덕터 방식의 양방향 dc-to-dc 컨버터)

  • Lee, Gi Yeong;Kang, Feel-soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.531-537
    • /
    • 2018
  • This paper propose a bidirectional dc-to-dc converter employing dual inductor for current ripple reduction. Conventional bidirectional dc-to-dc converter uses a single inductor for two different modes; boost and buck; therefore it is difficult to satisfy the optimized inductance value for each mode. To improve this problem, the proposed converter adds two switches, a diode, and one inductor. By proper switching of the additional switch, the proposed converter operates with a inductor in boost mode, but it works with dual inductor in buck mode. Hence in both modes the proposed bidirectional converter can be operated with optimized inductance values. Most of all the optimized inductance in buck mode can reduce the current ripple and its effective value(rms), which are directly related to the temperature increase resulted in short lifetime of battery. To verify the validity of the proposed approach, we first analyzes the operation of the proposed converter theoretically, and implement computer-aided simulations and experiments using a prototype.

Economic Feasibility Study for Peak Load Control (최대부하제어(最大負荷制御)의 경제적(經濟的) 타당성(妥當性) 검토(檢討))

  • Yu, Sung-Chul;Yoon, Kap-Koo;Cho, Soon-Bong
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.19-22
    • /
    • 1993
  • Demand side management (DSM) is the planning and implementation of those utility designed to influence customer use of electricity in ways that will produce desired changes in the utility's load shape. It is conspicuous that the peak load control of DSM is efficiently adopted. In this paper, the package type air conditioner(A/C) mounted radio controlled switch. During the summer of 1990 KEPCO conducted tests in Seoul areas to determine the economic feasibility of interrupting A/C units for short periods of time during peak load periods. These tests were performed between July 30 and September 20 and were limited to the hours of between 1 and 6 p.m. These tests indicated that each A/C contributes approximately 4.5kW to the system peak and can be switched off 10 minutes out of each 1/2 hour without causing the customer any discomfort. Switching each A/C off for 10 minutes out of each 1/2 hour results in a peak load demand reduction of one kW per unit.

  • PDF

Development of a Durability Test System for ATPS Used for Automatic Transmission (자동 변속기용 ATPS의 내구성 검사 시스템 개발)

  • Kim, Tae-Kue;Nam, Hyeong-Su;Shin, Eun-Hye;Yoon, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1585-1586
    • /
    • 2007
  • In this paper, a system of durability test for ATPS(Automatic Transmission Position Switch), which is used for automatic transmission, has been developed. ATPS is the position sensor for an automatic transmission which transforms the gear changes into the electrical signals and transmits them to TCU(Transmission Control Unit). This system can detect the output signals of the sensor, and also it has been designed to control the position and velocity of a motor to realize the sensor's movement under the running state of a car. And a database system and a GUI system have been developed for the systematic output data management and the convenient interface for users. Also, the operation data and the inspection reference data of a motor can be easily changed in this system, and with some modification the system is also able to used for the durability test of the similar products.

  • PDF

Development of a Traffic Signal Controller for the Tri-light Traffic Signal (3구신호등 제어용 교통신호제어기 개발)

  • Han, Won-Sub;Gho, Gwang-Yong;Heo, Nak-Won;Lee, Chul-Kee;Ha, Dong-Ik;Lee, Byung-Cheol
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.5
    • /
    • pp.49-58
    • /
    • 2010
  • The traffic signal controllers being used in the domestic currently are being manufactured based on the korean national police standard which was developed for controlling the quad-light traffic signal having the red, yellow, left-turn arrow, and green lights. But according to the national policy for the traffic operation, they have to be changed to be able to switch the tri-light signal having red, yellow and green lights. In this study, a new tri-light traffic signal controller was designed and developed by the way improving the Signal Control Unit of the existing quad-light standard traffic controller. The Load Signal Unit(LSU) was improved to output 6 signals which are the two assemblies of three signal indications having the red, yellow, and green lights. To enough traffic signals output to control each directional movements and the various transport modes which are car, bus, bike, and pedestrian etc., the connector bus system was designed to be able to accommodate maximum 96 signals outputs being constructed by 16 LSUs. Flasher device was developed to be able to support maximum 32 red signals. In the software, the communication protocol between traffic control center and the traffic signal controller was improved and new signal map code values were defined for the developed LSU controlling the quad-light traffic signal. A model of the quad-light traffic signal controller developed and was tested three operations, protocol-operation, remote-command and control-mode. The test result operated all of them successfully.

Design and Development of Network for Housing Estate Security System

  • Nachin, Awacharin;Mitatha, Somsak;Dejhan, Kobchai;Kirdpipat, Patchanon;Miyanaga, Yoshikazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1480-1484
    • /
    • 2003
  • This paper presents the design and development of network for housing estate security system. The system can cover up to 961 houses which can be up to 1,200 meters long transfer rate of 9,600 bps. This system uses checking and warning the abnormal situation. More over this system has ability to control switch on/off the electrical equipment in the house via AC line control system. The system consists of 4 parts. The first part is a security system of each house using MCS-51 microcontroller as a central processing unit scan 32 sensors and control 8 appliances and send alarm. The MCS-51 microcontroller received control signal via telephone used DTMF circuit. The second part is distributed two levels master/slave network implementing after RS-485 serial communication standard. The protocol its base on the OSI (Open Systems Interconnection) 7 layers protocol model design focus on speed, reliability and security of data that is transferred. The network security using encrypt by DES algorithm, message sequence, time stamp checking and authentication system when user to access and when connect new device to this system. Flow control in system is Poll/Select and Stop-and-Wait method. The third part is central server that using microcomputer which its main function are storing event data into database and can check history event. The final part is internet system which users can access their own homes via the Internet. This web service is based on a combination of SOAP, HTTP and TCP/IP protocols. Messages are exchanged using XML format [6]. In order to save the number of IP address, the system uses 1 IP address for the whole village in which all homes and appliance in this village are addressed using internal identification numbers. This proposed system gives the data transfer accuracy over 99.8% and maximum polling time is 1,120 ms.

  • PDF

Development A Standard of Traffic Signal Controller and Expectations of Standardization (교통신호제어기 표준 규격 개발)

  • Jeong Jun-Ha;Ahn Gye-Hyung;Oh Young-Tae;Go Gwang-Yong
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.5 no.1 s.9
    • /
    • pp.31-43
    • /
    • 2006
  • As of March 2005, the standard of traffic signal controllers became effective. The standard presents specifications and functions of a traffic signal controller which collects traffic information, sends it to the traffic control center, and controls traffic signal with adequate traffic signal timing provided by the traffic control center. Since the controllers by the previous standard lack parts compatibility and have different control functions and communication protocol, the maintenance cost has been increased. Also, some important functions like conflict detection have not worked out perfectly. To overcome these disadvantages, first of all, this standard secures hardware compatibility. Conflict detection method has been enhanced. Communication protocol to the traffic control center was included in the standard. With this standard, independent maintenance system and prompt treatment of hardware malfunctions becomes possible. Also, the unified intersection traffic control method will increase traffic safety.

  • PDF

Micro-scale Solar Energy Harvesting System with a New MPPT control (새로운 MPPT 제어기능을 갖는 마이크로 빛에너지 하베스팅 회로)

  • Yoon, Eun-Jung;Yoon, Il-Young;Choi, Sun-Myung;Park, Youn-Soo;Yu, Chong-Gun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.11
    • /
    • pp.2627-2635
    • /
    • 2013
  • In this paper micro-scale solar energy harvesting system with a new MPPT control are proposed. In conventional solar energy harvesting systems, continuous perturbation techniques of the clock frequency or duty cycle of a power converter have been used to implement MPPT(Maximum Power Point Tracking) control. In this paper, we propose a new MPPT technique to control the duty cycle of a power switch powering a power converter. The proposed circuit is designed in $0.35{\mu}m$ CMOS process, and the designed chip area including pads is $770{\mu}m{\times}800{\mu}m$.

A Study on Basic Technologic for File Transmission Between Base-Station and Mobile Hosts (베이스 스테이션과 모빌 호스트간의 파일전송 기초기술연구)

  • 김창식;김정원;정기동
    • Journal of Korea Multimedia Society
    • /
    • v.2 no.1
    • /
    • pp.59-68
    • /
    • 1999
  • Multimedia applications have an ability to transmit a lot of data in real time. In mobile circumstances the replay of continuous multimedia data in real time causes frequent replay breaks and poor service quality because of low transmission speed and new transmission path settings in hand-off. To avoid these unfavorable side effects, we need a new mechanism which can transmit data efficiently between base station and mobile hosts, to control the buffers of mobile hosts, and to switch to a new transmission path rapidly in hand-off. The study is to propose how to give good service to mobile hosts during hand-off and the mechanism which can increase the number of mobile hosts in the cell unit.

  • PDF

The Self-Fault Determination and Restoration Methodology based on the Ethernet Communication (이더넷 통신기반의 자율적 고장 판단 및 복구 방법론 연구)

  • Ko, Yun-Seok;Lee, Seo-Han;Choi, Hyun-Chul;Shin, Jae-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1674-1680
    • /
    • 2009
  • This paper proposes an autonomous fault determination, fault zone isolation and fault restoration strategy based on the ethernet communication as a new attempt to solve the problem the of the existing central control method. In proposed method, The FRTU(Feeder Remote Terminal Unit)s on the feeder determines autonomously where the faulted zone is by exchanging the voltage and current information with neighbor FRTUs based on the network communication, and then separates the faulted zone in an nil-voltage status to make the protective device to reclose successively. In particular, the minimization of outage time and relational load balancing is archived by each interconnection switch which determines autonomously the load zone to be allocated among those zones after the sound outage zones was separated individually. Finally, to show effectiveness of the proposed fault restoration strategy, the several fault cases are simulated for the test distribution system, and the load balancing index of the proposed solution is compared with all of feasible solutions.