• Title/Summary/Keyword: Swell

Search Result 352, Processing Time 0.028 seconds

PQ Analysis System Using Internet (인터넷을 이용한 전력품질 진단시스템)

  • Kim, Houng-Kyun;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.23-26
    • /
    • 2002
  • 전력품질 진단장치 개발을 위한 Hardware를 DSP를 이용하여 설계하였고 Software에서는 Sag, Swell, Interruption, Overvoltage, Undervoltage, Harmonic을 검출할 수 있는 알고리즘을 제시하였다. 또한 검출된 진단Data는 Network을 이용하여 원 거리에 있는 PC에서 Monitoring 함으로서 Field System의 전력분석에 효율적임을 증명하여 보였다.

  • PDF

A Study of Pourer Quality Disturbance Compensation using dq Transformation (dq 좌표변환을 이용한 전력외란 보상 연구)

  • Lee, Kyo-Sung;Lee, Yong-Jae;Kim, Do-Hun;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.286-289
    • /
    • 2002
  • In this paper, we use the PI dual control using do transformation(dq stationary frame and dq synchronous rotating frame) for series voltage sag and swell compensation algorithm. Analysis, simulation results are presented for voltage sags and swells on a three-phase unbalanced voltage source.

  • PDF

The devlepment of a MPC controller for water level control in the steam generator of a nuclear power plant (원전 증기발생기 수위제어를 위한 MPC 제어기 개발)

  • 손덕현;한진욱;이환섭;이창구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.359-359
    • /
    • 2000
  • Generally, level control in the steam generator of a nuclear power plant is difficulty process control, because the low power operating can lead nonminimum phase characteristics(swell and shrink phenomenon) and flow measurement are unreliable and nonlinear characteristics. This paper presents a framework for solving this problem based on the constrained linear model predictive control and introduces the design of method for the level of the controller in the entire operating power of the steam generator, and compares with conventional PI controller.

  • PDF

Estimation for misclassified data with ultra-high levels

  • Kang, Moonsu
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.1
    • /
    • pp.217-223
    • /
    • 2016
  • Outcome misclassification is widespread in classification problems, but methods to account for it are rarely used. In this paper, the problem of inference with misclassified multinomial logit data with a large number of multinomial parameters is addressed. We have had a significant swell of interest in the development of novel methods to infer misclassified data. One simulation study is shown regarding how seriously misclassification issue occurs if the number of categories increase. Then, using the group lasso regression, we will show how the best model should be fitted for that kind of multinomial regression problems comprehensively.

Z-Source Voltage Sag Compensator (Z-소스 전압Sag 보상기)

  • Kim, J.H.;Oum, J.H.;Jung, Y.G.;Lim, T.C.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.485-487
    • /
    • 2007
  • 본 연구에서는 Z-소스 네트워크를 갖는 순시전압sag 보상기를 제안하였다. 제안된 시스템은 연료전지 스택(fuel cells stack)을 갖고 있는 Z-소스 인버터의 shoot-through제어에 의하여 ac보상전압을 직접 발생한다. PSIM 시뮬레이션에 의하여 sag와 swell이 발생되는 정상상태와 과도상태에서의 제안된 방법의 타당성을 검토하였다.

  • PDF

Solvent Transport Characteristics of Glassy Polymers and its Analysis (유리고분자의 용매전달특성 및 그 해석)

  • 김덕준
    • Membrane Journal
    • /
    • v.8 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • The study on penetrant transport in glassy polymers has been actively pursued for decades because of its growing significance in polymer processing and related applications such as not only membranes, but corrosion protective coatings, microlithography, microelectronic fabrication, etc. In membranes application of polymeric materials, successful utilization requires understanding of how solvents penetrate, swell, and sometimes dissolve polymeric materials under various environmental conditions, as their permselecdve performance is significantly affected by it. The expose of polymer membranes to solvents may result in the structural failure due to mechanical softening, embrittlement or crazing.

  • PDF

A Proposal for Criterion of Sudden High Waves in the East Sea (동해에서 돌연고파의 기준 제안)

  • Kim, In-Chul;Oh, Jihee;Suh, Kyung-Duck
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.28 no.3
    • /
    • pp.117-123
    • /
    • 2016
  • One of the major characteristics of the swell-like high waves, which occur in the East Sea mostly in winter with large height and long period, is its suddenness associated with the rapid development of high waves from a calm state of sea. To represent such suddenness, in this study, the term sudden high waves is introduced. To propose the criterion of sudden high waves, comparisons were made between the wave measurement data at Gangneung and Wangdolcho for eight years from 2005 and the record of marine accidents and property damage on the coast of Gangwon-do Province and Gyeongsangbuk-do Province during the same period. It was found that most of the accidents occurred when ${\Delta}(H^2L)/{\Delta}t$ was approximately greater than the top 20% or $88.6m^3/hr$, which is therefore proposed as the criterion of sudden high waves. The used variable represents the rate of increase of the wave energy in one wavelength, including not only height and period but also suddenness of high waves.

An Efficient Control Strategy Based Multi Converter UPQC using with Fuzzy Logic Controller for Power Quality Problems

  • Paduchuri, Chandra Babu;Dash, Subhransu Sekhar;Subramani, C.;Kiran, S. Harish
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.379-387
    • /
    • 2015
  • A custom power device provides an integrated solution to the present problems that are faced by the utilities and power distribution. In this paper, a new controller is designed which is connected to a multiconverter unified power quality conditioner (MC-UPQC) for improving the power quality issues adopted modified synchronous reference frame (MSRF) theory with Fuzzy logic control (FLC) technique. This newly designed controller is connected to a source in order to compensate voltage and current in two feeders. The expanded concept of UPQC is multi converter-UPQC; this system has a two-series voltage source inverter and one shunt voltage source inverter connected back to back. This configuration will helps mitigate any type of voltage / current fluctuations and power factor correction in power distribution network to improve power quality issues. In the proposed system the power can be conveyed from one feeder to another in order to mitigate the voltage sag, swell, interruption and transient response of the system. The control strategies of multi converter- UPQC are designed based on the modified synchronous reference frame theory with fuzzy logic controller. The fast dynamics response of dc link capacitor is achieved with the help of Fuzzy logic controller. Different types of fault conditions are taken and simulated for the analysis and the results are compared with the conventional method. The relevant simulation and compensation performance analysis of the proposed multi converter-UPQC with fuzzy logic controller is performed.

Correlating the hydraulic conductivities of GCLs with some properties of bentonites

  • Oren, A. Hakan;Aksoy, Yeliz Yukselen;Onal, Okan;Demirkiran, Havva
    • Geomechanics and Engineering
    • /
    • v.15 no.5
    • /
    • pp.1091-1100
    • /
    • 2018
  • In this study, the relationships between hydraulic conductivity of GCLs and physico-chemical properties of bentonites were assessed. In addition to four factory manufactured GCLs, six artificially prepared GCLs (AP-GCLs) were tested. AP-GCLs were prepared in the laboratory without bonding or stitching. A total of 20 hydraulic conductivity tests were conducted using flexible wall permeameters ten of which were permeated with distilled deionized water (DIW) and the rest were permeated with tap water (TW). The hydraulic conductivity of GCLs and AP-GCLs were between $5.2{\times}10^{-10}cm/s$ and $3.0{\times}10^{-9}cm/s$. The hydraulic conductivities of all GCLs to DIW were very similar to that of GCLs to TW. Then, simple regression analyses were conducted between hydraulic conductivity and physicochemical properties of bentonite. The best correlation coefficient was achieved when hydraulic conductivity was related with clay content (R=0.85). Liquid limit and plasticity index were other independent variables that have good correlation coefficients with hydraulic conductivity (R~0.80). The correlation coefficient with swell index is less than other parameters, but still fairly good (R~0.70). In contrast, hydraulic conductivity had poor correlation coefficients with specific surface area (SSA), smectite content and cation exchange capacity (CEC) (i.e., R < 0.5). Furthermore, some post-test properties of bentonite such as final height and final water content were correlated with the hydraulic conductivity as well. The hydraulic conductivity of GCLs had fairly good correlation coefficients with either final height or final water content. However, those of AP-GCLs had poor correlations with these variables on account of fiber free characteristics.