• 제목/요약/키워드: Sustained load

검색결과 113건 처리시간 0.026초

Design of A Force-Reflecting Device and Embedded Controller

  • Kim, Dae-Hyun;Moon, Cheol-Hong;Choi, Han-Soo;Kim, Yeong-Dong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2397-2401
    • /
    • 2005
  • It is well understood that force reflecting coupled with visual display can be an important two-way communication channel in human-computer interaction. In this work, important components for a high-fidelity system bandwidth are force reflecting device and that all the computations including contact determination and response computation have to be performed in less than a millisecond. This paper describes a force-reflecting device and an embedded controller. The realized force-reflecting device is based on a novel serial type mechanical structure, and features compactness, high sustained output force capability, low friction, zero backlash, and enough workspace. The embedded controller reduces software computational load via main processor and simplifies hardware strictures by the time-division control. The device is integrated with existing dynamic simulation algorithms running separate workstation, so that objects can be manipulated in real time and the corresponding forces felt back by the operator.

  • PDF

메탄올 농도에 따른 직접 메탄올 연료전지의 성능 해석 (Performance Characteristics of Direct Methanol Fuel Cell with Methanol Concentration)

  • 조창환;김용찬;장영수
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.197-204
    • /
    • 2008
  • DMFC(Direct Methanol Fuel Cell) is one of promising candidates for power sources of small mobile IT devices like notebook, cell phone, and so on. Efficient operation of fuel cell system is very important for long-sustained power supply because of limited fuel tank size. It is necessary to investigate operation characteristics of fuel cell stack for optimal control of DMFC system. The generated voltage was modeled according to various operating condition; methanol concentration, stack temperature, and load current. It is inevitable for methanol solution at anode to cross over to cathode through MEA(membrane electrode assembly), which reduces the system efficiency and increases fuel consumption. In this study, optimal operation conditions are proposed by analyzing stack performance model, cross-over phenomenon, and system efficiency.

RC 기둥과 SRC 기둥의 장기거동에 관한 실험적 연구 (Experimental Study on Long-term Behavior of RC and SRC Columns)

  • 권승희;김진근;정한욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.481-486
    • /
    • 2003
  • This paper presents experimental study on long-term behavior of RC and SRC columns. Shrinkage and creep tests were performed for two types of concrete used in manufacturing RC and SRC column specimens. Also, long-term tests under sustained load were carried out for RC and SRC column specimens. Shrinkage functions and creep coefficients to optimally fit the corresponding data were obtained from regression analysis and the regression results, ACI and CEB- FIP 90 model were applied to analyse long-term behvavior of RC and SRC column specimens. Creep coefficients calculated from test data were lower than those predicted by ACI and CEB-FIP 90 models. Long-term analysis results for RC and SRC column specimens using the regression results were relatively more accurate than those obtained using the existing models.

  • PDF

보강혼합토의 압축 크리프 특성 (Compressive Creep Properties of Reinforced Soil Mixture)

  • 이상호;차현주;김철영
    • 한국농공학회지
    • /
    • 제44권6호
    • /
    • pp.115-123
    • /
    • 2002
  • This study was performed to provide basic data for development and construction of reinforced soil wall that mixed with reinforcements such as calcium carbonate, monofilament fiber. In order to determine proper moisture content and mixing ratio by weight of reinforcement, Poisson's ratio and compressive strength tests for sandy soil had been conducted. Model tests for long-term behavior of reinforced soil wall were carried out to investigate the effect of reinforcement during loads and under static loads. The results of creep and model tests for sandy soil compared with clayey soil. Reinforced sandy soil mixed with calcium carbonate and cement showed brittle rupture by shear but that of mixed with monofilament fiber showed ductile rupture due to the tension force of fiber. It was shown that when age increased, creep strain of reinforced soil under sustained load approached constant values.

THE IMPACT OF FUEL CYCLE OPTIONS ON THE SPACE REQUIREMENTS OF A HLW REPOSITORY

  • Kawata, Tomio
    • Nuclear Engineering and Technology
    • /
    • 제39권6호
    • /
    • pp.683-690
    • /
    • 2007
  • Because of increasing concerns regarding global warming and the longevity of oil and gas reserves, the importance of nuclear energy as a major source of sustainable energy is gaining recognition worldwide. To make nuclear energy truly sustainable, it is necessary to ensure not only the sustainability of the fuel supply but also the sustained availability of waste repositories, especially those for high-level radioactive waste (HLW). From this perspective, the effort to maximize the waste loading density in a given repository is important for easing repository capacity problems. In most cases, the loading of a repository is controlled by the decay heat of the emplaced waste. In this paper, a comparison of the decay heat characteristics of HLW is made among the various fuel cycle options. It is suggested that, for a future fast breeder reactor (FBR) cycle, the removal and burning of minor actinides (MA) would significantly reduce the heat load in waste and would allow for a reduction of repository size by half.

Time-dependent analysis of reinforced concrete structures using the layered finite element method

  • Bradford, M.A.;Gilbert, R.I.;Sun, S.C.H.
    • Structural Engineering and Mechanics
    • /
    • 제8권6호
    • /
    • pp.561-578
    • /
    • 1999
  • The response of a reinforced concrete structure to loading is both immediate and time-dependent. Under a sustained load, the deflections caused by creep and shrinkage may be several times their instantaneous values. The paper describes a general finite element procedure, based on the so-called layered model, to analyse reinforced concrete members, and shows in particular how the simple Step by Step Method may be incorporated into this procedure. By invoking the Modified Newton Raphson Method as a solution procedure, the accuracy of the finite element method is verified against independent test results, and then applied to a variety of problems in order to demonstrate its efficacy. The method forms a general method for analysing highly indeterminate concrete structures in the time domain.

Long-term deflection of high-strength fiber reinforced concrete beams

  • Ashour, Samir A.;Mahmood, Khalid;Wafa, Faisal F.
    • Structural Engineering and Mechanics
    • /
    • 제8권6호
    • /
    • pp.531-546
    • /
    • 1999
  • The paper presents an experimental and theoretical study on the influence of steel fibers and longitudinal tension and compression reinforcements on immediate and long-term deflections of high-strength concrete beams of 85 MPa (12,300 psi) compressive, strength. Test results of eighteen beams subjected to sustained load for 180 days show that the deflection behavior depends on the longitudinal tension and compression reinforcement ratios and fiber content; excessive amount of compression reinforcement and fibers may have an unfavorable effect on the long-term deflections. The beams having the ACI Code's minimum longitudinal tension reinforcement showed much higher time-dependent deflection to immediate deflection ratio, when compared with that of the beams having about 50 percent of the balanced tension reinforcement. The results of theoretical analysis of tested beams and those of a parametric study show that the influence of steel fibers in increasing the moment of inertia of cracked transformed sections is most pronounced in beams having small amount of longitudinal tension reinforcement.

고온에서의 콘크리트 재료 역학적 특성에 관한 연구 (A Study on Mechanical Properties of Concrete at Elevated Temperatures)

  • 박찬규;김규용;이승훈;박주헌;김영선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.769-772
    • /
    • 2006
  • The effects of high temperature on strength, elastic modulus and strain at peak stress of concrete were experimentally investigated. The type of test was the stressed test that a preload was applied to the specimen prior to heating and the load was sustained during the heating period. In this study, the level of preload was 25% of compressive strength at room temperature. All tests were conducted at various temperatures(20,100, 200, 300, 400, 500, 600 and $700^{\circ}C$) for concretes made with W/B ratios 46% and 32%. Test results showed that on the whole, the relative values of strength and elastic modulus, and the real strain value at peak stress were not influenced by the W/B ratio.

  • PDF

Statistical characteristics of sustained wind environment for a long-span bridge based on long-term field measurement data

  • Ding, Youliang;Zhou, Guangdong;Li, Aiqun;Deng, Yang
    • Wind and Structures
    • /
    • 제17권1호
    • /
    • pp.43-68
    • /
    • 2013
  • The fluctuating wind induced vibration is one of the most important factors which has been taken into account in the design of long-span bridge due to the low stiffness and low natural frequency. Field measurement characteristics of sustained wind on structure site can provide accurate wind load parameters for wind field simulation and structural wind resistance design. As a suspension bridge with 1490 m main span, the Runyang Suspension Bridge (RSB) has high sensitivity to fluctuating wind. The simultaneous and continuously wind environment field measurement both in mid-span and on tower top is executed from 2005 up to now by the structural health monitoring system installed on this bridge. Based on the recorded data, the wind characteristic parameters, including mean wind speed, wind direction, the turbulence intensity, the gust factors, the turbulence integral length, power spectrum and spatial correlation, are analyzed in detail and the coherence functions of those parameters are evaluated using statistical method in this paper. The results indicate that, the turbulence component of sustain wind is larger than extremely strong winds although its mean wind speed is smaller; the correlation between turbulence parameters is obvious; the power spectrum is special and not accord with the Simiu spectrum and von Karman spectrum. Results obtained in this study can be used to evaluate the long term reliability of the Runyang Suspension Bridge and provide reference values for wind resistant design of other structures in this region.

지오그리드 보강토 교대의 장기거동에 관한 수치해석 연구 (Long-Term Behavior of Geogrid Reinforced Soil Abutment - A Numerical Investigation)

  • 유충식;전한용
    • 한국지반공학회논문집
    • /
    • 제27권1호
    • /
    • pp.65-76
    • /
    • 2011
  • 본 논문에서는 보강토 구조물의 장기거동에 관한 수치해석 내용을 다루었다. 본 연구는 사용연한동안 지속하중을 받는 보강토 구조물의 장기 변형 관련 메카니즘을 고찰하는데 주 목적을 두었다. 연구를 위해 먼저 Singh-Mitchell 크리프 모델과 멱함수(Power law) 크리프 모델을 이용하여 각각 뒤채움흙과 보강재의 크리프 변형을 모델링하는 방안을 구축하였으며 이를 토대로 뒤채움흙과 토목섬유 보강재의 크리프 특성에 대한 매개변수 연구를 수행하였다. 해석결과 외부하중을 받는 보강토 구조물이 세립분이 많이 포함되어 있는 흙으로 뒤채움이 될 경우 뒤채움흙과 토목섬유 보강재로부터 발생하는 크리프 효과로 인해 상당한 크기의 장기 변형이 발생할 수 있는 것으로 나타났다. 본 논문에서는 외부하중을 받는 보강토 구조물에 있어서 크리프 효과가 구조물의 사용성에 미치는 영향을 집중적으로 고찰하였다.