• 제목/요약/키워드: Suspension insulator

검색결과 83건 처리시간 0.047초

국부오손이 옥외절연물의 전기적 특성에 미치는 영향 (Influence upon electrical properties of outdoor insulators with non-uniformity contamination)

  • 이원영;최남호;박강식;한상옥
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.203-206
    • /
    • 2001
  • Since th three sides of korea peninsula are surrounded by the sea, electric apparatus are greatly contaminated by the salt generated by the typhoon, seasonal wind, sea wind and sea fog. This contamination causes electric power apparatus to fail. Thus in this paper, we investigated to influence upon electrical properties of outdoor insulators with non-uniformity contamination in the experimental condition because The contamination of outdoor insulator highly depended wind property In the service condition, insulator was not uniformly contaminated. From the flashover test for the 254 mm suspension insulator, we could determine the influence non-uniform contamination on the electrical property of insulators. Through the experiment, we convinced to occur flashover from non-uniform contamination region of outdoor insulator. Contaminated area and pattern has a close relationship with the electrical properties of outdoor insulator.

  • PDF

폴리머 절연물 소재의 전기적 밀 복합열화 특성평가 기술 (Evaluation Technology of Electrical and reliableility Characteristics for Outdoor Polymer Insulator Materials)

  • 안명상;박효열;나문경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1343-1344
    • /
    • 2006
  • There have been numerous accelerated aging laboratory tests for evaluating suitability of polymeric materials and devices. Aging test for materials and its full scale device has been conducted. Service experience plays a key role in the utility section of composite insulators. A meaningful and reliable accelerated aging test is needed for evaluating composite insulator. During the service these insulators are subjected to aging stress such as humidity, pollution, and electrical field, and erosion and tracking of the weathershed occurs. This paper presents the criteria of reliability evaluation and evaluation facilities for 22.9 kV suspension composite insulator. We adopt the criteria of reliability evaluation consist of two test methods. One is CEA tracking wheel test for examining the tracking and erosion performance of composite insulator. The other is multi-stress aging test for examining effects of environmental factors such as UV, temperature, humidity, etc on composite insulator.

  • PDF

ANSYS를 이용한 송전용 자기재 애자의 장력에 따른 특성 변화 (A Variation of Maximum Stress with Axial Loading in Porcelain Insulators for Transmission Line using ANSYS)

  • 우병철;한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.104-107
    • /
    • 2003
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of cement for suspension insulator. These simulation analysis and experimental results show that cement volume growths affect severely to be mechanical failure ageing. These simulation analysis and experimental results show that axial loading affects of Porcelain insulators severely to be mechanical failure ageing.

  • PDF

신소재를 적용한 배전용 폴리머 현수애자의 평가 기술 (Dead-end/Suspension Composite Insulator for Overhead Distribution Lines)

  • 소진중;김인성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1490-1492
    • /
    • 2001
  • Recently polymer composite materials has been replacing the porcelain in suspension insulators as a insulating material. The polymer composite materials are introduced into Korea from the abroad, so there is, actually, no formal standard of assessment Both the porcelain insulator specifications and composite material test specifications are being used at the same time. The aim of this project is to establish a systematic standard suitable to current situations considering the trends of its production within Korea. This would protect the inner-markets against the market-opening and would promote the industrial development within a country.

  • PDF

송전용 자기재 현수애자의 원료변화에 따른 특성 연구 (A Study on Properties of Porcelain Suspension Insulator for Transmission Line by a Change of Raw Materials)

  • 최인혁;최장현;이동일;최연규
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.390-395
    • /
    • 2004
  • In order to analyze the physical and chemical characteristics of home production porcelain insulators by change of the alumina addition amount, 360001bs ball socket type suspension insulators which were manufactured in 1989, 1995 and 2001 removed in transmission line and an experiment was performed. By the result, 8 wt.% alumina that influences the mechanical properties and arc resistance properties in case of insulators that were manufactured in 1989 was contained, and the relative density and the fracture toughness of insulators appeared by 94.2% and 1.4 ㎫$.$ $M^{\frac{1}{2}}$, respectively. However, 12 wt.% alumina was contained in case of insulators that were manufactured in 1995, and the relative density and the fracture toughness of insulators appeared preferably lower by 92% and 1.3㎫$.$ $M^{\frac{1}{2}}$, respectively. Amount of alumina was contained most by 17 wt.% in case of insulators that were manufactured in 2001. It was confirmed that the electrical and mechanical characteristics such as the relative density and the fracture toughness appeared excellently by 96% and 1.7㎫$.$ $m^{\frac{1}{2}}$, respectively.

한전 765 kV 송전선로 애자장치 강도계열 및 지지방식에 관한 검토 (A study on the mechanical strength system and supporting method of insulator strings for KEPCO 765kV transmission lines)

  • 한엽;박광희;윤상훈;서철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1920-1922
    • /
    • 1996
  • After determining the type and string condition of conductor of 765kV transmission lines, we studied the mechanical strength system of insulator strings to support conductors and insulate conductors from towers. In this paper, for the insulator strings which will be used in 765kV transmission lines, we're going to optimally determine the mechanical strength system and supporting method in the consideration of the reliability, economics and the survey data of T/L routes, and also suggest the calculation method to stipulate for the application limits of suspension and strain insulator strings according to the loadspan and height difference of tower.

  • PDF

배전급 고분자 현수애자의 제조기술 개발 (Manufacturing Technique of Suspension Insulator far Distribution Lines Using Composite materials)

  • 홍진영;김영성;지응서;김영찬;백주흠;김동욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.306-310
    • /
    • 1996
  • In this paper a series of developing process for an insulator which can be employed in overhead distribution lines, using polymeric composite materials, is introduced. In order to design an insulator for heavily polluted area, weathershed of alternating type was adopted, which could have longer leakage distance. Modified EVA was used as surface material which has good electrical and mechanical characteristics as well as superior chemical stability. FRP core was covered with above surface material through heat shrinking process. By standardization of each process, higher productivity and lower production cost could be ensured. The developed insulator has been put under various tests including long-term field test and artificial aging test and satisfactory results were obtained.

  • PDF

154kV급 Hollow Composite Insulator의 기계적 강도해석 및 특성시험 (The Performance Test and Mechanical Strength Analysis for 154kV Hollow Composite Insulator)

  • 박기호;조한구;한동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.495-498
    • /
    • 2002
  • This paper describes the results the problem of stress calculation and optimization into a FRP(Fiber-glass Reinforced Plastic) tube crimped into a metal end-fitting. This type of assembly is used mainly is used mainly for suspension and line post insulators. Fitting strength of FRP and flange of this study is required greatly from composite insulator to important special quality. Therefore, wish to seek analysis and mechanical strength performance that follow to FRP tube and flange of top and bottom mechanical fitting.

  • PDF

환경에 따른 송전용 애자의 누설전류 분석 (Analyses of Leakage Current of Transmission Insulator as a Function of Environmental Condition)

  • 최인혁;이동일;김찬영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1166-1170
    • /
    • 2004
  • The leakage currents of transmission insulator were investigated as a function of environmental conditions, such as temperature, humidity, and rainfall. The insulators were artificially contaminated with insoluble yellow soil and kaolin which helped salt to stick on the surface of insulator. The insulators contaminated with the grade of B, C, and D were installed in the KoChang Testing Center. The leakage currents were measured and compared with non-contaminated insulators. The results indicated that the most important factor affecting leakage current was humidity. After heavy rain, the artificially contaminated salt was dissolved, resulting in similar characteristics between with and without contamination

  • PDF

송전용 현수애자의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Transmission Suspension Insulators)

  • 송일근;김찬영
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권7호
    • /
    • pp.406-411
    • /
    • 2000
  • This paper presents the results of performance confirmation tests for domestic 20 [Ton] transmission suspension insulators which will be widely utilized in transmission lines. The new test methods such as power arc test, steep-front-of-wave flashover voltage test, and etc. which have been only utilized for the distribution insulators were applied in transmission suspension insulators. The properties of metal and cement used in the 20 [Ton] transmission insulators were also evaluated by the various analysis techniques. Based on the results, we evaluated the performance of the transmission suspension insulators.

  • PDF