• Title/Summary/Keyword: Suspended particle

Search Result 295, Processing Time 0.028 seconds

ESTIMATION OF IOP FROM INVERSION OF REMOTE SENSING REFLECTANCE MODEL USING IN-SITU OCEAN OPTICAL DATA IN THE SEAWATER AROUND THE KOREA PENINSULA

  • Moon, Jeong-Eon;Ahn, Yu-Hwan;Ryu, Joo-Hyung;Yang, Chan-Su
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.224-227
    • /
    • 2006
  • For estimation of three inherent optical properties (IOPs), the absorption coefficients for phytoplankton ($a_{ph}$) and suspended solid particle ($a_{ss}$) and dissolved organic matter ($a_{dom}$), from ocean reflectance, we used inversion of remote sensing reflectance model (Ahn et al., 2001) at this study. The IOP inversion model assumes that (1) the relationship between remote sensing reflectance ($R_{rs}$) and absorption (a) and backscattering ($b_{b}$) is well known, (2) the optical coefficients for pure water ($a_{w}$, $b_{bw}$) are known, (3) the spectral shapes of the specific absorption coefficients for phytoplankton ($a^*_{ph}$) and suspended solid particle ($a^*_{ss}$) and the specific backscattering coefficients for phytoplankton ($b_b^*_{ph}$) and suspended solid particle ($b_b^*_{ss}$) are known. The input data of IOP inversion model is used in-situ ocean optical data at the seawater around the Korea Peninsula for 5 years (2001-2005). We compared the output data of the IOP inversion model and the in-situ observation for seawater around the Korea Peninsula.

  • PDF

Studies on the Total Suspended Particulates in Iksan City. (익산시의 부유먼지에 관한 연구)

  • 전병영
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.158-164
    • /
    • 1999
  • This study was carried out to investigate total suspended particulates (TSP) in Iksan area collected by nine stages Anderson air sampler and High volume air sampler from Jul. 1996 to Jul. 1998.The results are as follows1. The average of TSP concentration to be collected by Anderson air sampler and High volume air sampler in Iksan city are $59{\mu}g/m^3$, $67{\mu}g/m^3$. It was below the level of environmental standard. 2. The average of TSP concentration by measured method are HVAS > AS > Gov. 3. The average of TSP concentration on seasonal change are higher spring than winter. It were $65.5{\mu}g/m^3$ of Spring, $57{\mu}g/m^3$ of Summer, $52.5{\mu}g/m^3$ of Fall, $61{\mu}g/m^3$ of Winter. 4. Particle size 3istribution of atmospheric particulate was divided into two groups, coarse group was made by particles larger than $1.1-2.1{\mu}m$ in diameter and fine groups smaller than $1.1-2.1{\mu}m$ in diameter. about 50% of total suspended particle measured by Anderson air sampler during the sampling period was coarse particle.

  • PDF

Verification of Silt Density Index (SDI) as a fouling index for reverse osmosis (RO) feed water (역삼투 공정 파울링 지표로서 SDI(Silt Density Index)의 적합성 검증)

  • Kim, Su-Han;Kim, Chung-H.;Kang, Suk-H.;Lee, Won-T.;Lim, Jae-L.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.489-495
    • /
    • 2011
  • Silt Density Index (SDI) has been used as a fouling index for reverse osmosis (RO) processes for decades. In order to decrease RO fouling, feed water should meet SDI standard, which was used to select a proper pretreatment system for RO processes. However, SDI is supposed to be sensitive only to particles larger than 0.45 ${\mu}m$ in terms of diameters while nanoparticles and dissolved organic matter can be potent foulants for RO processes. Our study started from the suspected performance of SDI as a RO fouling index. SDI data from pilot plants located world wide including South Korea were collected and analyzed. Suspended partcle concentration (i.e., turbidity and particle counts), and dissolved organic matter concentration (i.e., dissolved orgnaic carbon (DOC) concentration) data were also collected and compared to SDI values of same water samples. We found that SDI values were not only affected by suspended particle concentration but also by dissolved organic matter concentration. Therefore SDI can be used as a reasonable fouling index for RO feed water because the main foulants for RO processes are suspended particle and dissolved organic matter.

Effect of Fertilizer Composed of Dam Suspended Particle Sawdust and Sewage Sludge to Soil Properties and Tree Growth (댐 부유물 톱밥과 하수슬러지를 활용한 부숙질 비료가 수목생장 및 토양특성에 미치는 영향)

  • Ryu, Ji-Hoon;Park, Gwan-Soo;Lee, Hang-Goo;Lee, Sang-Jin;Park, Bum-Hwan;Lee, Jong-Jin
    • Korean Journal of Agricultural Science
    • /
    • v.37 no.2
    • /
    • pp.217-222
    • /
    • 2010
  • This study was conducted to investigate the effect of fertilizer composted of dam suspended particle sawdust and sewage sludge to soil properties and seedling growth. The Betula platyphylla var japonica, Zelkova serrata and Chamaecyparis obtusa were used for this study. The soil organic matter, total nitrogen, phosphorous, exchangeable calcium, magnesium, and potassium were increased with fertilizer treatment. Heavy metal concentration in soil was increased with fertilizer treatment, but the level was very low. With fertilizer treatment, growth, photosynthetic capacity, and chlorophyll concentration of seedling were improved.

Serial Particle Size Fractionation and Water Quality in a Recirculating Aquaculture System for Eel

  • Lee, Jin-Hwan
    • Fisheries and Aquatic Sciences
    • /
    • v.13 no.2
    • /
    • pp.133-139
    • /
    • 2010
  • The effects of suspended solids size on culture water quality were determined in a commercial recirculating aquaculture system (RAS) for Japanese eel, Anguilla japonica. The particulate phase of the culture water was serially divided into six size fractions using 300, 200, 100, 75, 45, and 26 ${\mu}m$ pore size stainless sieves. The total, dissolved, and particulate nitrogen and phosphorus, and suspended solids for each fraction were determined. The concentration ranges in the fractions were: total nitrogen, 164-148 mg $L^{-1}$; total phosphorus, 20.4-15.5 mg $L^{-1}$; and total suspended solids, 8.1-6.1 mg $L^{-1}$. The concentration of total nitrogen and total phosphorus decreased significantly (P<0.05) with a 26 ${\mu}m$ and 200 ${\mu}m$ filter pore size, respectively. Nutrients from dissolved organic substances were much higher than from particulates. Analysis of particle size fractionation and its effects on water quality is useful to estimate removal efficiencies of a commercial effluent screening device for solid management and development of solid removal systems.

Ignition Temperature and Residence Time of Suspended Magnesium Particles (마그네슘 부유 분진의 입자 체류시간과 발화온도)

  • Han, Ou-Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.25-31
    • /
    • 2015
  • Effects of residence time on the MIT(Minimum Ignition Temperature) in suspended Mg particles are examined by using MIT experimental data and calculation results of terminal velocity. With increasing of the average particle diameter, we were able to identify that MIT of Mg dusts increased and the calculated residence time of particle decreased exponentially. Also, the influence on terminal velocity due to temperature increase increased slightly with increasing of average particle diameter.

Performance Analysis of a Hydrodynamic Separator for Treating Particulate Pollutants in Highway Rainfall Runoff

  • Yu, Jianghua;Yi, Qitao;Kim, Young-Chul
    • Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.262-269
    • /
    • 2009
  • This study examined the separation characteristics of particles in the rainfall runoff from paved roads using a ${\varphi}7.5$ cm hydrocyclone. The volume fraction and total suspended solids concentrations in the overflow and underflow from the hydrocyclone, as well as the separation efficiency were determined. The results indicated that the overflow volume increased with increasing operational pressure, but decreased with decreasing ratio of underflow outlet to inlet sizes ($D_u/D_i$), while the underflow to overflow volumes showed contrary behavior. The total suspended solid (TSS) concentration ratio between the overflow and inflow ($TSS_{over/in}$) decreased as a function of the operational pressure, while the corresponding ratio of underflow to inflow ($TSS_{under/in}$) increased. There was no visible difference in the $TSS_{over/in}$ with increasing $D_u/D_i$ ratio, but the $TSS_{under/in}$ decreased sharply. The particle removal efficiency was mainly affected by the particle size.

Effects of Civil Blasting on Noise, Vibration and Total Suspended Particles (토목 발파가 소음, 진동, 부유 분진에 미치는 영향)

  • Jeong, Jin Do;Jeong, Yeong Guk
    • Journal of Environmental Science International
    • /
    • v.13 no.1
    • /
    • pp.99-107
    • /
    • 2004
  • This research is to determine the level of environmental pollution at a blasting construction area which is the origin of noise, vibration, and suspended particle, and to compare the results with other domestic and international standard data. This experiment is also to find out the effects resulting from blasting construction and to propose a plan that can decrease environmental pollution. The blasting construction area is a factory site which is about one and half million square meter and sewage disposal plant is about ninety thousand square meter. Both were selected as the areas for the tests to be conducted in determination test. The test to determine the level of noise, vibration, and total suspended particle was conducted thirty times around the blasting construction area by comparing measurement results and numerical analysis. However, as the test was not conducted in the laboratory but in the actual blasting construction area, it was not possible to do the test with the same exact conditions each true. Therefore, the test was not ideal as conditions could change from test to test. For the most part, the level of noise was below the standard level of 70dB. Every vibration test was under the standard limitation. For example, a house, 200m away was tested for noise and vibration and the level was found to be under the 0.2 cm/sec which is the standard for specialty designed cultural sites., i.e very low level. Also a buried oil pipeline that was 30m away also marked under 2.0cm/sec which is the norm for an industrial area. However, if there were an oil pipeline under the house, the amount of charging gunpowder per hole should be decreased compared to the amount used in the test. The test result for suspended particles under the standard limitation which is 24hour average 300$\mu\textrm{g}$/㎥ at a distance from blasting wavelength, but at detonator, total suspended particle from the blast origin exceeded the standard limitation. If explosion occurs when it detonates in the hole, most of the energy would be absorbed in the crushing of rocks, but some remaining energy would make noises and vibration inevitable. So the important thing is how to minimize the environmental pollution from the blasting. There should be regulations in order that the standard limitation is not exceeded, and to decrease the environmental pollution from the blasting.

The Study on the Composting by Using Dam Suspended Particle Sawdust and Sewage Sludge (댐부유물 톱밥과 하수슬러지를 이용한 퇴비화 연구)

  • Ryu, Ji-Hune;Lee, Jong-Jin;Hong, Joo-Hwa;Chang, Ki-Woon;Lee, Gyu-Seung;Park, Gwan-Soo;Han, Ki-Pil
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.1
    • /
    • pp.98-103
    • /
    • 2010
  • This study was carried out on the composting of the most part of the plant waste materials inflowed-drifting into the dam during the localized heavy rain and the rainy season, due to the abnormal climate change, and for the sewage sludge banned to dispose legally into the ocean from the year of 2012. It was analysed the distinctive physicochemical qualities of the compost with treatment S-1(dam suspended particle sawdust : oak tree bark : sewage sludge : chicken manure = 30 : 20 : 40 : 10) and treatment S-2(dam suspended particle sawdust : oak tree bark : sewage sludge : chicken manure = 30 : 30 : 30 : 10). Both S-1 and S-2 maintained for 10 days at above $65^{\circ}C$ of the compost pile temperature, and the most of its pathogen were destroyed. In case of pH, until the 90th day into composting, S-1 with the pH value of 7.78 was slightly higher than S-2. The C/N value of S-1 was 15.3 and that of S-2 was 16.9. The quality of its final product was satisfied to the manufacture-standards. The GI value of S-1 was 91 higher than that of S-2, which was 84. In conclusion, it is highly recommendable to manufacture S-1 for its frequent usage of dam suspended particle sawdust and sewage sludge, and for its excellent quality and safety.

Analysis of Solids in Runoff to Prevent Solids Pollution (오염저감 기법개발을 위한 유출수내 고형물질 특성 규명)

  • Lee, Young-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.1
    • /
    • pp.22-28
    • /
    • 2004
  • The fate and transport mechanism of pollutants which have affinities to particles, such as trace metals and some petroleum product based compounds, can be effectively explained by the movement of sediment. The sediment release from lands to adjacent water bodies due to rainfall events was investigated in an effort to predict the total suspended solids (TSS) concentrations in runoff. The contribution of sediment from land origin to the river TSS can be better understood by the relationship between TSS concentration and particle size in runoff. The sieve analysis was used to determine the particle size distribution and these results were incorporated into statistical models. The critical size of particles was set to $74{\mu}m$ which contributes to the river TSS concentration since fine particles (wash load) of the sediment in the runoff play the key role in constituting TSS in a water column of the river. Empirical relationships were developed to predict TSS in runoff from the percentage of the critical particle size and were proven statistically to be valid.