Browse > Article

Verification of Silt Density Index (SDI) as a fouling index for reverse osmosis (RO) feed water  

Kim, Su-Han (부경대학교 토목공학과)
Kim, Chung-H. (한국수자원공사 K-water연구원 상하수도연구소)
Kang, Suk-H. (한국수자원공사 K-water연구원 상하수도연구소)
Lee, Won-T. (한국건설기술연구원 건설환경연구실)
Lim, Jae-L. (한국수자원공사 K-water연구원 상하수도연구소)
Publication Information
Journal of Korean Society of Water and Wastewater / v.25, no.4, 2011 , pp. 489-495 More about this Journal
Abstract
Silt Density Index (SDI) has been used as a fouling index for reverse osmosis (RO) processes for decades. In order to decrease RO fouling, feed water should meet SDI standard, which was used to select a proper pretreatment system for RO processes. However, SDI is supposed to be sensitive only to particles larger than 0.45 ${\mu}m$ in terms of diameters while nanoparticles and dissolved organic matter can be potent foulants for RO processes. Our study started from the suspected performance of SDI as a RO fouling index. SDI data from pilot plants located world wide including South Korea were collected and analyzed. Suspended partcle concentration (i.e., turbidity and particle counts), and dissolved organic matter concentration (i.e., dissolved orgnaic carbon (DOC) concentration) data were also collected and compared to SDI values of same water samples. We found that SDI values were not only affected by suspended particle concentration but also by dissolved organic matter concentration. Therefore SDI can be used as a reasonable fouling index for RO feed water because the main foulants for RO processes are suspended particle and dissolved organic matter.
Keywords
Silte Density Index (SDI); Pretreatment; Reverse Osmosis (RO) Process;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김수한 (2003) Polydispersity 조건에서 Crossflow 방식 정밀여과의 케이크 형성 특성 및 제어방안에 관한 연구, KAIST 건설및환경공학과 박사논문
2 한국수자원공사 (2008) 해양심층수를 이용한 해수담수화, 한국수자원공사
3 한국수자원공사 (2009) 산업용수제조 역삼투시스템의 설계 및 운영기술 개발, 한국수자원공사
4 환경부 (2002) 해수담수화시설 적정설치․운영방안 조사연구, 환경부.
5 AWWA (2006) Desalination of seawater and brackish water, American Water Works Association.
6 ASTM, Standard test method for silt density index (SDI) of water, D 4189-95 ASTM.
7 Boerlage, S.F.E., Kennedy, M., Aniye, M.P. and Schippers, J.C. (2003) Applications of the MFI-UF to measure and predict particulate fouling in RO systems, J. Membr. Sci. 220 pp.97-116.   DOI
8 Boerlage, S.F.E. Kennedy, M.D., Dickson, M.R., El-Hodali D.Y., and Schippers, J.C. (2002) The modified fouling index using ultrafi ltration membranes (MFI-UF): characterisation, filtration mechanisms and proposed reference membrane, J. Membr. Sci. 197 pp.1-21.   DOI
9 Butt, F.H., Rahman, F. and Baduruthamal, U. (1997) Hollow fine fiber VS. spiral-wound RO desalination membranes part 1: pilot plant evaluation, Desalination 109 pp.67-82.   DOI   ScienceOn
10 Gilron, J., Chaikin, D., Daltrophe N. (2000) Demonstration of CAPS pretreatment of surface water for RO, Desalination 127 pp.271-282.   DOI   ScienceOn
11 Halpern, D.F., McArdle, J., Antrim, B. (2005) UF pretreatment for SWRO: pilot studies, Desalination 182 pp.323-332.   DOI
12 Khirani, S., Ain, R.B. and Manero, M.-H. (2006) Improving the measurement of the modified fouling index using nanofiltration membranes (NF-MFI), Desalination 191 pp.1-7.   DOI
13 Kim, S., and Hoek E.M.V. (2007) Interactions controlling biopolymer fouling of reverse osmosis membranes, Desalination 202, pp.333-342.   DOI
14 Kim, S., Lee, S., Kim, C.H. and Cho, J. (2009) A new membrane performance index using flow field flow fractionation (fl-FFF), Desalination 247
15 Mitrouli, S.T., Yiantsios S.G., Karabelas, A.J., Mitrakas, M., Follesdal, M., Kjolseth, P.A. (2008) Pretreatment for desalination of seawater from an open intake by dual-media filtration: Pilot testing and comparison of two different media, Desalination 222 pp.24-37.   DOI
16 Mosset, A., Bonnelye, V., Petry, M., Sanz, M.A. (2008) The sensitivity of SDI analysis: from RO feed water to raw water, Desalination 222 pp.17-23.   DOI   ScienceOn
17 Qin, J.J., Oo, M.H., Lee, H., Kolkman, R. (2004) Dead-end ultrafiltration for pretreatment of RO in reclamation of municipal wastewater effluent, J. Membr. Sci. 243 pp.107-113.   DOI
18 Schippers, J.C., and Verdouw, J. (1980) A method of determining the fouling characteristics of water, Desalination 32 pp.137-148.   DOI
19 Schippers, J.C., Hanemaayer, J.H., Smolders, C.A., and Kostense, A. (1981) Predicting flux decline of reverse osmosis membranes, Desalination, 38 pp.339-348.   DOI
20 Zhang, J.D., Liu, Y.W. Gao, S.M., Li, C.Z., Zhang, F., Zen, H.M., Ye, C.S. (2006) Pilot testing of outside-in UF pretreatment prior to RO for high turbidity seawater desalination, Desalination 189 pp.269-277.   DOI