• Title/Summary/Keyword: Susceptibility imaging

Search Result 129, Processing Time 0.026 seconds

NMR Functional brain Imaging with the Tailored RF Pulse (TAILORED RF PULSE를 이용한 NMR에서의 뇌 기능 영상법)

  • Ro, Y.M.;Cho, Z.H.;Mennon, R.S.;Ugurbil, K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.21-24
    • /
    • 1993
  • The experimental results of visual stimulation with the tailored RF pulse are reported. Tailored RF pulse is used for the susceptibility effect imaging. Around 25% signal change of visual cortex area is detected during photic stimulation. Interestingly, with the tailored RF pulse, the signal intensity of visual cortex is deceased during photic stimulation. It is, however, increased with normal $T_2$ weighted imaging. The comparison between normal $T_2$ weighted imaging and the tailored RF pulse imaging are performed with 4T NMR system and the results with human volunteer are also presented.

  • PDF

Interference Issuses of Radio Frequency Identification Devices in Magnetic Resonance Imaging Systems and Computed Tomography Scan

  • Periyasamy, M.;Dhanasekaran, R.
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.295-301
    • /
    • 2015
  • We evaluated certain issues related to magnetic resonance imaging (MRI) coupled with the use of active 2.5 GHz radio frequency identification (RFID) tags for patient identification using low field (0.3 T) MRI and computed tomography (CT) scans. We also investigated the performance of the RFID reader located outside the MRI room by considering several factors. A total of ten active RFID tags were exposed to several MRI sequences and X-rays of CT scan. We found that only card type active RFID tags are suitable for patient identification purpose in MRI environment and both wristbands as well as card tags were suitable for the same in CT environment. Severe artifacts were found in the captured MRI and CT images when the area of the imaging was in proximity to the tags. No external factors affected the performance of active RFID reader stationed outside the MRI scan room.

Leak Sign on Dynamic-Susceptibility-Contrast Magnetic Resonance Imaging in Acute Intracerebral Hemorrhage

  • Park, Ji Kang;Hong, Dae Young;Jin, Sun Tak;Lee, Dong-Woo;Pyun, Hae Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.3
    • /
    • pp.154-161
    • /
    • 2020
  • Purpose: A CT angiography spot sign (CTA-spot) is a significant predictor of the early expansion of an intracerebral hemorrhage (ICH-Ex). Dynamic-susceptibility-contrast magnetic resonance imaging (DSC-MRI) can track the real-time leaking of contrast agents. It may be able to indicate active bleeding, like a CTA-spot. Materials and Methods: From September 2014 to February 2017, we did non-contrast CT, CTA, and DSC-MRI examinations of seven patients with acute ICH. We investigated the time from symptom onset to the first contrast-enhanced imaging. We evaluated the time course of the contrast leak within the ICH at the source image of the DSC-MRI and the volume change of ICH between non-contrast CT and DSC-MRI. We compared the number of slices showing CTA-spots and DSC-MRI leaks. Results: The CTA-spot and DSC-MRI leak-sign were present in four patients, and two patients among those showed ICH-Ex. The time from the symptom onset to CTA or DSC-MRI was shorter for those with a DSC-MRI leak or CTA-spot than for three patients without either (70-130 minutes vs. 135-270 minutes). The leak-sign began earlier, lasted longer, and spread to more slices in the patients with ICH-Ex than in those without ICH-Ex. The number of slices of the DSC-MRI leak and the number of the CTA-spot were well correlated. Conclusion: DSC-MRI can demonstrate the leakage of GBCA within hyperacute ICH, showing the good contrast between hematoma and contrast. The DSC-MRI leakage sign could be related to the hematoma expansion in patients with ICH.

In Vitro Assessment of MRI Safety at 1.5 T and 3.0 T for Bone-Anchored Hearing Aid Implant (Bone-Anchored Hearing Aid Implant에 대한 1.5 T와 3.0 T에서 MRI 안전성의 생체외 평가)

  • Yeon, Kyoo-Jin;Kim, Hyun-Soo;Lee, Seung-keun;Lee, Tae-Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.19-25
    • /
    • 2017
  • The aim of this study was to evaluate Magnetic Resonance Imaging safety by measuring the translational attraction, torque and susceptibility artifact for Bone-Anchored Hearing Aid (BAHA) implant at 1.5 T and 3.0 T MRI by standard criteria. In vitro assessment tools were made of acrylic-resin by American Society for Testing and Materials (ASTM) F2052-06 and F2119-07 standard. Translational attraction of BAHA implant was measured by the maximum deflection angle at 96 cm position, where the magnetically induced deflection was the greatest. The torque was assessed by the qualitative criteria of evaluating the alignment and rotation pattern, when the BAHA implant was positioned on a line with $45^{\circ}$ intervals inside the circular container in the center of the bore. The susceptibility artifact images were obtained using the hanged test tool, which was filled with $CuSO_4$ solution. And then the artifact size was measured using Susceptibility A rtifact Measurement (SA M) software. In results, the translational attraction was 0 mm at both 1.5 T and 3.0 T and the torque was 0(no torque) at 1.5 T, and +1(mild torque) at 3.0 T. The size of susceptibility artifacts was between 13.20 mm and 38.91 mm. Therefore, The BAHA implant was safe for the patient in clinical MR environment.

Penalized logistic regression using functional connectivity as covariates with an application to mild cognitive impairment

  • Jung, Jae-Hwan;Ji, Seong-Jin;Zhu, Hongtu;Ibrahim, Joseph G.;Fan, Yong;Lee, Eunjee
    • Communications for Statistical Applications and Methods
    • /
    • v.27 no.6
    • /
    • pp.603-624
    • /
    • 2020
  • There is an emerging interest in brain functional connectivity (FC) based on functional Magnetic Resonance Imaging in Alzheimer's disease (AD) studies. The complex and high-dimensional structure of FC makes it challenging to explore the association between altered connectivity and AD susceptibility. We develop a pipeline to refine FC as proper covariates in a penalized logistic regression model and classify normal and AD susceptible groups. Three different quantification methods are proposed for FC refinement. One of the methods is dimension reduction based on common component analysis (CCA), which is employed to address the limitations of the other methods. We applied the proposed pipeline to the Alzheimer's Disease Neuroimaging Initiative (ADNI) data and deduced pathogenic FC biomarkers associated with AD susceptibility. The refined FC biomarkers were related to brain regions for cognition, stimuli processing, and sensorimotor skills. We also demonstrated that a model using CCA performed better than others in terms of classification performance and goodness-of-fit.

Antibiotic susceptibility and imaging findings of the causative microorganisms responsible for acute urinary tract infection in children: a five-year single center study

  • Yoon, Ji-Eun;Kim, Wun-Kon;Lee, Jin-Seok;Shin, Kyeong-Seob;Ha, Tae-Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • Purpose: We studied the differences in the antibiotic susceptibilities of the microorganisms that causeing urinary tract infections (UTI) in children to obtain useful information on appropriate drug selection for childhood UTI. Methods: We retrospectively analyzed the antibiotic susceptibilities of 429 microorganisms isolated from 900 patients diagnosed with UTI in the Department of Pediatrics, Chungbuk National University Hospital, from 2003 to 2008. Results: The most common causative microorganisms for UTI were Escherichia coli (81.4%), Klebsiella pneumoniae (8.4%), Enterobacter spp. (1.7%), and Proteus spp. (0.4%). E. coli showed relatively high susceptibility as compared to imipenem (100%), amikacin (97.7%), aztreonam (97.9%), cefepime (97.7%), and ceftriaxone (97.1%), while it showed relatively low susceptibility to gentamicin (GM) (79.0%), trimethoprim/sulfamethoxazole (TMP/SMX) (68.7%), ampicillin/sulbactam (33.0%), and ampicillin (AMP) (28.6%). There were no significant differences in the image findings for causative microorganisms. Conclusion: Gram-negative organisms showed high susceptibility to amikacin and third-generation cephalosporins, and low susceptibility to AMP, GM, and TMP/SMX. Therefore, the use of AMP or TMP/SMX as the first choice in empirical and prophylactic treatment of childhood UTI in Korea should be reconsidered and investigated further.

Susceptibility-Weighted Imaging as a Distinctive Imaging Technique for Providing Complementary Information for Precise Diagnosis of Neurologic Disorder (신경계 질환에 관한 정확한 진단을 위해 다양한 보완 정보를 제공하는 독특한 영상 기법으로서의 자기화율 강조 영상)

  • Byeong-Uk Jeon;In Kyu Yu;Tae Kun Kim;Ha Youn Kim;Seungbae Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.99-115
    • /
    • 2021
  • Various sequences have been developed for MRI to aid in the radiologic diagnosis. Among the various MR sequences, susceptibility-weighted imaging (SWI) is a high-spatial-resolution, three-dimensional gradient-echo MR sequence, which is very sensitive in detecting deoxyhemoglobin, ferritin, hemosiderin, and bone minerals through local magnetic field distortion. In this regard, SWI has been used for the diagnosis and treatment of various neurologic disorders, and the improved image quality has enabled to acquire more useful information for radiologists. Here, we explain the principle of various signals on SWI arising in neurological disorders and provide a retrospective review of many cases of clinically or pathologically proven disease or components with distinctive imaging features of various neurological diseases. Additionally, we outline a short and condensed overview of principles of SWI in relation to neurological disorders and describe various cases with characteristic imaging features on SWI. There are many different types diseases involving the brain parenchyma, and they have distinct SWI features. SWI is an effective imaging tool that provides complementary information for the diagnosis of various diseases.

Cerebral Blood Volume Mapping from Dynamic Susceptibility Contrast Magnetic Resonance Images (Dynamic Susceptibility Contrast Magnetic Resonance Images를 이용한 뇌혈류량 지도 구성)

  • Kim, S.J.;Lee, S.K.;Kim, K.G.;Kim, J.H.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.281-282
    • /
    • 1998
  • Recently, there has been growing interest in the assessment of physiological parameters on brain perfusion that provide more information than pure morphologic diagnosis. Quantification of parameters that characterize cerebral micro-circulation with magnetic resonance imaging is of great relevance for clinical application. We determine the local tissue concentration by exponential relationship between the relative signal reduction S(t)/$S_0$ and local tissue concentration of contrast material $C_m(t)$ in dynamic susceptibility contrast enhanced MR imaging. And then we made relative regional blood volume map by calculating the area under the measured concentration-time curves $C_m(t)$ during first pass of paramagnetic contrast material as a preliminary step for perfusion map. These images make it possible to compare the rCBV in different brain regions in one individual at a time. We have it in contemplation to obtain arterial and brain signal time curves simultaneously to make absolute rCBV and perfusion (rCBF) map. These maps may provide the method of comparative investigations of different patients having strong variation in AIF.

  • PDF

Brain Abscess Showing a Lack of Restricted Diffusion and Successfully Treated with Linezolid

  • Kim, Joo-hyun;Park, Sang-phil;Moon, Byung-gwan;Kim, Deok-ryeong
    • Brain Tumor Research and Treatment
    • /
    • v.6 no.2
    • /
    • pp.92-96
    • /
    • 2018
  • A 59-year-old patient with a history of hepatocellular carcinoma presented with decreased consciousness and left hemiparesis. A rim-enhanced mass lesion without diffusion restriction was observed in contrast-enhanced MRI including diffusion-weighted imaging. Based on these findings, metastatic brain tumor was suspected. However, brain abscess (BA) was diagnosed after multiple bacterial colonies were observed in aspiration biopsy. Initial conventional antibiotic treatment including vancomycin had failed, so linezolid was used as second-line therapy. As a result, infection signs and clinical symptoms were resolved. We report a case with atypical imaging features and antibiotic susceptibility of a BA in an immunocompromised patient undergoing chemotherapy.

A study on image distortion improvement using silicon device in thyroid diffusion MRI images (갑상선의 확산강조영상 검사 시 실리콘 이용한 뒤틀림 감소에 관한 연구)

  • Choi, Kwan-Woo;Seo, Dae-Keon;Lee, Ho-Beom;Goh, Hee-Jin;Na, Sa-Ra;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4380-4386
    • /
    • 2014
  • This study was conducted to minimize the imaging distortion by reducing the differences in susceptibility between the tissue and air surrounding it while performing a thyroid diffusion imaging procedure. The study group was composed of 23 healthy adults. Thyroids with many distortions near the air, larynx, and trachea were chosen to test and evaluate the diffusion imaging difference between before and after an application of silicon. As a result, there was reduced distortion with silicon application, and the differences decreased from 30% to 10%. According to One-way ANOVA and Duncan's post-hoc test, there were no significant differences between imaging with a silicon application and T2 imaging of the surface area, which was the standard image. In conclusion, this study presented a radical improvement in reducing the distortions in imaging by compensating for an uneven tissue surface near air without affecting the magnetic resonance contrast and complicating the imaging processes.