• Title/Summary/Keyword: Survey meter

Search Result 172, Processing Time 0.039 seconds

DEEP: KMTNet DEep Ecliptic Patrol

  • Moon, Hong-Kyu;Choi, Young-Jun;Kim, Myung-Jin;Ishiguro, Masateru;Thuillot, William
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.122.2-122.2
    • /
    • 2011
  • For more than a decade, NEA (Near-Earth Asteroid) survey teams equipped with 1 meter-class telescopes discovered thousands of NEAs in the northern sky. As of August 2011, some 8,200 NEAs have been cataloged, yet only five percent of them has been investigated for their physical and chemical properties. In order to improve current situation, we propose a deep ecliptic survey utilizing KMTNet, for detection and characterization of NEAs in the southern sky. Thanks to the wide-field capability (four square degrees) of the telescopes, we will be able to considerably expand the search volume carrying out precision photometry down to 21.5th magnitude. We plan to focus our survey on opposition and two "sweet spots" in the ecliptic belt. Since SDSS colors characterize mineralogical properties of NEAs, g', r', i', z' filters will be employed. Based on the round-the-clock observation, we will study their rotational properties; for multiple systems, mass, density and other physical parameters can be obtained. We plan to maintain a dedicated database of the physical and mineralogical properties of NEAs. With this archive, it is expected that our understanding on the population will see a drastic change. We also plan to participate in the GAIA Follow-Up Network for ground based observation of the Solar System Objects (GAIA-FUN-SSO). The follow- up astrometry will be performed upon alerts issued by the GAIA-FUN-SSO Central Node in France.

  • PDF

A High-resolution Seismic Survey on the Abandoned Tidal Flat in Shihwa Lake (시화호내 과거 조간대에서의 고해상 탄성파 탐사)

  • Hong, Jong Guk;Kim, Gi Yeong;Choe, Dong Rim
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.4
    • /
    • pp.251-258
    • /
    • 1999
  • A high-resolution seismic survey was conducted on the abandoned tidal flat in Shihwa Lake on the west coast of Korea. A portable vibrator was used as a seismic source and 217 shot gathers with 48-channel system were acquired. F-k filtering, residual static corrections and post-stack frequency filtering are found to be useful for signal enhancement. The overburden is divided into two seismic depositional units. Unit I is deposited in tidal environment characterized by parallel and high continuity reflection pattern. This unit comprises a dry layer (Unit Ia) and a wet layer (Unit Ib) having averagely 5 and 15 meters thick, respectively. Unit II unconformably overlain by Unit I exhibits discontinuity and hummocky reflection pattern, indicating complex channel-fill sediments in estuary. The maximum thickness of this unit is approximately 20 meter. Acoustic basement is considered as Precambrian granitic gneiss occurred in the surrounding area.

  • PDF

Effective Half-life of I-131 in Patients with Differentiated Thyroid Cancer Treated by Radioactive I-131 (I-131 치료를 받은 분화갑상선암 환자에서 I-131의 유효반감기)

  • Park, Seok-Gun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.464-468
    • /
    • 2008
  • Purpose: Effective half life of I-131 ($T_{eff}$) in patients with differentiated thyroid cancer treated by I-131 is must-know value for dose calculation and determination of release time from isolation room. There has been no report about $T_{eff}$ in Koreans. Thus, author tried to measure dose rate without radiation exposure to faculty members and calculated $T_{eff}$. Methods: Probe of radiation survey meter was fixed at the wall of isolation room, and body of survey meter was placed outside the room. With this simple arrangement, author could measure radiation frequently without radiation exposure to faculty members in 68 patient (F=55, M=13, age=$47{\pm}13.7$) treated by I-131 ($3.7{\sim}7.4\;GBq$) for differentiated thyroid cancer from Jan 2006 to Dec 2006. From this data, $T_{eff}$, 48 hr retention rate, and the time necessary to whole body retention of I-131 become less than 1.1 GBq were calculated. Serum creatinine levels were measured before and after thyroid hormone withdrawal. Results: $T_{eff}$ was $15.4{\pm}4.3\;hr$ ($9.4{\sim}32.5\;hr$). There was a loose correlation between $T_{eff}$ and serum creatinine concentration (r=0.45). 48hr retention was $4.9{\pm}4.2%$ ($1{\sim}23%$). Time necessary to whole body retention of I-131 become less than 1.1 GBq was calculated as $47.1{\pm}13.2\;hr$ for 9.25 GBq, $42.1{\pm}11.9\;hr$ for 7.4 GBq, $35.7{\pm}10.0\;hr$ for 5.55 GBq, and $26.7{\pm}7.5\;hr$ for 3.7 GBq dose of I-131. Conclusion: Author successfully measured radiation dose rates in isolated patients treated by high dose of I-131 without radiation exposure to the faculty members with simple arrangement of survey meter probe. Using those data, $T_{eff}$ and some other indices were calculated.

A Study on Medical Waste Contaminated by Radioactivity in Nuclear Medicine Department (핵의학과 일반 의료폐기물에서의 방사능 오염에 관한 고찰)

  • Yoo, Jae-Sook;Jang, Jung-Chan;Lee, Dong-Hoon;Cha, Min-Kyeong;Nam, Ki-Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.70-74
    • /
    • 2011
  • Purpose: In the Nuclear Medicine department of Asan Medical Center, radioactive waste has been disposed of by using several disposal boxes designed for nuclear waste. However, some quantity of radioactivity has been detected occasionally due to some radiologists' carelessness not only from radioactive waste, but also from medical waste such as uncontrolled radioactive waste related to patients, poly gloves or saline solution bottles from radiopharmaceuticals laboratory. Thus, this study is going to suggest a solution to maintain the medical wastes made from controlled areas that can be below maximum permissible surface dose limits by finding the cause of radioactive contamination. Materials and methods: This study was taken place in 17 different places-2 medical wastebaskets in the waiting room, 2 medical wastebaskets in the PET room, 5 medical wastebaskets in the in vitro laboratory and 6 medical wastebaskets in the radiopharmaceuticals laboratory of the East building, 2 medical wastebaskets in the waiting room of the New building of Nuclear Medicine Department in Asan Medical Center from April to August 2010. Mean radioactivity and its standard deviation of each place have been found by measuring surface contamination of medical wastebaskets and backgrounds twice a week, totaling 30 times. An independent t-test of SPSS (Ver. 12.0) statistic program has been used for statistical analysis. Swabs, saline solution bottles and poly gloves collected from each place also measured 30 times, respectively. Results: This study analyzed medical waste and the backgrounds of each place by using survey meter detectors that significant differences of five places did not exist, but existed statistically in twelve places (p<0.05). Also, swabs, saline solution bottles and poly gloves collected from each radioactive waste partly exceed the legal dose limit as a result of measuring by a gamma counter. Conclusion: Backgrounds and the surface doses of radioactive disposal box in all 17 places measured by the survey meter did not exceed the legal dose limit; however, it obviously showed that there were prominent differences in 12 places. Assuming that the cause of the differences was swabs, saline solution bottles and gloves, we examined them by gamma counter, and the results showed remarkably high doses of radioactivity. Consequently, swabs and poly gloves which are normally disposed in the general medical waste box should be disposed in the radioactive waste box furnished by radiopharmaceuticals laboratory. Also, saline solution discharged from radioactive pharmaceutical places is considered as radioactive liquid waste so that it should be disposed of by the septic tank specifically designed for radioactive liquid.

  • PDF

Evaluation on the radiation exposure from activated wedge filter (10MV 이상 고에너지 사용시 wedge filler의 방사화가 작업환경에 미치는 영향평가)

  • Lee HwaJung;Kim DaeYoung;Kim WonTaek;Lee KangHyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.69-79
    • /
    • 2004
  • In the process of photon treatments, linear accelerators with energies higher than 10 MV produce neutrons through the (${\gamma}$, n) interactions with the composite materials of the linac head md these materials further produce the induced radiations. We investigate the possible risks from these induced radiations especially in the wedge filters to the radiation workers. Wedge filters are used to modify the isodose profiles in the radiation treatment using the linear accelerator and always be handled by the radiation workers. For the background radiation, we measured the radiation in both the waiting room and the outside of the building for two hospitals, S and H. The results of S hospital were $0.11\;{\mu}Sv/hr$ and $0.10\;{\mu}Sv/hr$ for waiting room and outside respectively, and in the case of H hospital, they were $0.12\;{\mu}Sv/hr$ and $0.11\;{\mu}Sv/hr$. Using a survey meter, we measured the radiation from wedge filters inserted in 10 MV and 15 MV Siemens linear accelerators. The time series measurements were done in ${\sim}1$ minutes after exposure of 5 Gy of monitor units for the field size of $25{\times}25cm^2$. The starting value of 10 MV machine was about $3.26\;{\mu}Sv/hr$, which was three times higher than that of 10 MV. The measured radiation was from $^{28}Al$ and $^{53}Fe$ with a half life of 3.5 min. If the treatment patients are $20{\sim}50$ per day and the number of process of wedge filter change per patient is one or two, the annual dose equivalent is $0.08{\sim}0.4\;mSv$ for 10 MV, and $0.27{\sim}1.36\;mSv$ for 15 MV, which are in the range of dose equivalent limits of radiation workers.

  • PDF

Report of Present Status of Calibration for Domestic Radiation Measurements Instruments (국내 방사선 측정장비 보유 현황 및 교정 현황 조사)

  • Lim, Sangwook;Choi, Jinho;An, Sohyun;Cho, Kwang Hwan;Lee, Sang Hoon;Lee, Rena;Cho, Sam Ju
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.46-53
    • /
    • 2016
  • Periodical calibrations of radiation detectors are important for accurate quality assurance of therapeutic linac. The measuring instruments such as ion-chamber, thermometer, barometer, and survey meter should be calibrated periodically. Period of calibration for these instruments is suggested 6 month to one year in Korea and two years in other countries nowadays. Therefore, the determination of reasonable period for calibration is needed. In this study, we plan to utilize the results of these survey; frequent in use, how to use and stability of instruments, to determine the optimized period of calibration for the instruments in the departments of radiation oncology in Korea based on the ILAC-G24. The SurveyMonkey web-based survey tool was used and the objects of survey were 18 department of radiation oncology in university hospitals, and 15 departments were answered. The 64 questionnaires which supposed to be answered in 50 minutes were classified as the information of candidates, the thermometer, the barometer, the surveymeter, and the ion-chamber. The thermometers and the barometers were not under periodical calibration for more than half of candidates. The periods of calibration of surveymeters were 6 month to 1 year. We expect that the calibration period can be determined based on these survey results.

Stratigraphical Study on Tertiary System of Pohang Area Compared with Petrogeologies of Japan (포항(浦項)의 제삼기층(第三紀層)과 일본유전지질(日本油田地質)의 층위대비연구(層位對比硏究))

  • Chang, Seyong
    • Economic and Environmental Geology
    • /
    • v.9 no.1
    • /
    • pp.1-11
    • /
    • 1976
  • It is believed that geological survey, drilling and geophysical survey which was carried out on Tertiary deposits in Pohang is a valuable but through the studying of many Tertiary sediments in Japan discovered many questions on analysis of final report prepared by National geological survey. The main reason is: 1. The seismic sound velocity which have regulated in the final report prepared by geological survey for Tertiary deposits in Pohang was 1,500-2,000m/sec in spite of oil bearing sediments of same age in Japan are 2,000-3,800m/sec. These may means the requirement of reconsideration of seismic velocity for Tertiary deposits in Pohang and required to have a dipper drilling. 2. Stratigraphically, geophysically, and paleontologically, the Tertiary deposits in Pahang land area is similar with that of Nishiyama-Hunakawa formations of Akita oil field in Japan. Nishiyama-Hunakawa formation is the main oil bearing formation in Japan. 3. Those valcanic rock including andestitic rock and liparitic rock which have extensively distributed over either at land area or at sea bottom, assumed by geological survey as the base of Tertiary sediments. But in case of Japan many oil bearing deposits are in over laid by these kind of volcanic rock. Therefore a possible of same condition with Japan is presumable on Tertiary sediments in Pohang. 4. It is believed that the Tertiary sediments of land area in Pohang is the extension of offshore basin but is wandering that the final report submitted by geologic survey have not remain any word on report of ECAFE discribed so much problematics as followed: A. Although it was assumed that no great thickness exceeding 1,000 meters, or major structures would be encountered in the Tertiary offshore sequence, it was hoped that shallow hydrocarbon deposits might be found, because these sediment are lithologically similar to those of the same age in the producing area of the northwest Honshu region of Japan where hydrocarbon are extracted from depths of only 500 to 600 meters. B. Four possible hydrocarbon trap conditions are represented in the survey area: anticlinal folds, faults, pinch outs, along the igneous basement and lateral facies changes. C. Most of the prime possible reservoir area are beyond the 50 meter water depth mark, except for the structures in Yonil Bay. D. Despite the shallowness of the offshore basin, sufficient trap condition exist in the area to warrant further exploration for hydrocarbon. 5. All of the problems mentioned above have gave us a strong reasons to have us hesitating to make a final conclusion on Tertiary problems in Pohang, before to have a drill to a depth to 3,000 meters or more whatever it is the Tertiary or a Mesozoics below 1,000 meters.

  • PDF

A Basie Community Health Survey in Rural Korea (Soyang-Myun) (소양면 지역사회 환경기초조사)

  • Choi, Sung-Yul
    • Journal of Preventive Medicine and Public Health
    • /
    • v.6 no.1
    • /
    • pp.133-160
    • /
    • 1973
  • 1. Introduction Community medicine with the concept of comprehensive medical care and an ideal medical care delivery system not only for an individual or family but for the whole community has emerged. In April 1970, the Presbyterian Medical Center started a hospital based community health service project in order to improve the health of the people in rural areas. Prior to commencing a comprehensive medical care system, a family survey was needed. The major objective of this survey was to obtain information concerning the people and their environment so as to be able to plan and implement a comprehensive medical care program in Soyang-Myun. 2. Survey Method An interview using a family record form was carried out for each household. This family record form was designed to get information about demography, family planning, environmental sanitation and vital statistics. Prior to beginning, the members of the survey team were trained in interviewing techniques for three days. The team consisted of a public health nurse, four nurse-aides, a sanitarian and four health extension workers who are working in our project, The survey was carried out during the period November 1971 to March 1972. 3. Project area 1) Population of Soyang-Myun was 11,668; male, 5,962 and female, 5,706. Sex ratio: 104.5. 2) Households : 1,858 3) Family size: The average household consisted of 6.3 persons. 4) Educational level of householder a. Illiterate 13% b. No schooling but able to read 10% c. Preschool children 19% d. Primary school 47% e. Middle school 7% f. High school 3% g. College or University 1% 5) Occupational distribution of householders a. Farmer 67% b. Laborer 13% c. Office worker 4% d. Merchant 4% e. Industrial worker 2% f. Unemployed 8% g. Miscellaneous 2% 6) Religious affiliation a. No religion 74% b. Buddhist 12% c. Protestant 10% d. Catholic 4% 4. Survey results Living Environment : a. Home ownership 95% b. Kinds of roofing Straw-thatched house 84% Tile-roofed house 10% Slate-roofed house 5% Other 1% c. Floor space Less than 6 pyong 10% 6-10 pyong 53% 11-15 pyong 24% 16-20 pyong 9% More than 20 pyong 4% d. Radio ownership 80% Environmental Sanitation : a. the source of drinking water public well 49% private well 30% drainage water 9% steam water 8% well pump 3% water distribution system 1% b. Distance between well and toilet more than 16meters 38% 6-10 meter 31% 11-15 meters 14% Less than 6 meters 17% c. The status of well management Bad 72% Fair 26% Good 2% d. General sanitary state of house Bad 37% Fair 51% Good 12% e. House drainage system had no house drainage. 77% Family Planning : a. 24% of the people have used contraceptives, but 12% ceased to use them. 76% have never used contraceptives. b. used methods 1oop 68% oral pill 16% vasectomy 4% condom 1% tubal ligation 1% two or more methods 10% Maternal Health : a. The number of conceptions of housewives under 50 years of age. 11 times 26% 6 times 11% 5 times 11% 4 times 9% b. The place of delivery own house 88% hospital 1% others 11% Treatment of general sickness : a. The place of treatment Soyang Health Center 31% Hospital (private or otherwise) 26% Pharmacy 14% Herb medicine 5% Private care 5% No treatment 12% Miscellaneous 7% b. Usual causes of diseases Unknown 46% Tuberculosis 29% Neuralgia 8% CVA 3% Bronchitis 3% Others 11%

  • PDF

Fabrication and estimation of the plastic detector for measuring the contamination for beta-ray level of the kind of duct waste (배관류 폐기물의 베타선 오염도 측정용 플라스틱 검출기 제작 및 특성평가)

  • Kim Gye-Hong;Oh Won-Zin;Lee Kune-Woo;Seo Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.159-165
    • /
    • 2005
  • The characterization of radiological contamination inside pipes generated during the decommission of a nuclear facility is necessary before pipes can be recycled or disposed. But, existing direct measurements of radioactive contamination level using the survey-meter can not estimate the characteristic of contamination on a local area such as the pipe inside. Moreover, the measurement of surface contamination level using the indirect methods has many problems of an application because of the difficulty of collecting sample and contamination possibility of a worker when collecting sample. In this work, plastic scintillator was simulated by using Monte Carlo simulation method for detection of beta radiation emitted from internal surfaces of small diameter pipe. Simulation results predicted the optimum thickness and geometry of plastic scintillator at which energy absorption for beta radiation was maximized. In addition, the problem of scintillator processing and transferring the detector into the pipe inside was considered when fabricating the plastic detector on the basis of simulation results. The characteristic of detector fabricated was also estimated. As a result, it was confirmed that detector capability was suitable for the measurement of contamination level. Also, the development of a detector for estimating the radiological characteristic of contamination on a local area such as the pipe inside was proven to be feasible.

  • PDF

Characteristics of accretion and scour around artificial reefs in the southern waters of Korea (한국 남해안에 시설된 인공어초 주위의 퇴적과 세굴 특성)

  • Kim, Chang-Gil;Suh, Sung-Ho;Oh, Tae-Gun;Kim, Byung-Gyun;Choi, Yong-Suk;Sheehy, Daniel J.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.233-233
    • /
    • 2011
  • This study describes the characteristics of accretion and scour around artificial reefs in Korea. The survey for accretion and scour was made at a dice reef set consisting of 137 dice reefs. The volume of a dice reef unit is 8 $m^3$. The reef set was placed on the muddy sand at 21.6 m in November of 1999. Equipment used in the survey includes Side Scan Sonar, Multi Beam Echo Sounder, Sub-Bottom Profiler and water current meter. According to the results, the artificial reefs are heaped up at two to three times (4 m) the height of the dice reef. The maximum current around the artificial reefs was 81.5 cm/sec at the ebb tide and 72.7 cm/sec at the flood tide. Scour around artificial reefs occurs upstream to the flow while accretion is formed at wake zone in the downstream. The height of accretion ranges from 2.4 to 3.0 m. The crest of the accretion is formed at the distance of about 10 m from the edge of the reef. The slope of accretion is formed steeply at the vicinity of the reef which is at right angles to the direction of main current, and grows gently lower with the increased distance from the reef. Scour is continuously caused by upwelling from the reef set and by side currents that flow parallel to side of the accretion. Also, scour takes place on the deposited sediment rather than on the remaining bottom sediments. This means that, once fully formed, the depth of scour gully on both sides to the direction of main current hardly changes.

  • PDF