• Title/Summary/Keyword: Survey meter

Search Result 174, Processing Time 0.034 seconds

Effect of an Intensive Rehabilitation Program on Physical Activity and Wearing Satisfaction in Traumatic Lower Limb Amputees -A Retrospective Study- (집중재활프로그램이 하지 절단 환자의 신체활동 및 의지 착용감에 미치는 영향 -후향적 연구-)

  • Kim, Jin-Hong;Hong, Ye-Ji;Kim, Yu-Ri;Lee, Gang-Pyo
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.453-463
    • /
    • 2020
  • Purpose: This study aimed to investigate the effect of an intensively rehabilitation program on the gait, balance, functional performance, and wearing satisfaction of patients with traumatic lower extremity amputations caused by industrial accidents. Methods: In this study, the anonymized electronic medical records of individuals who participated in the intensive rehabilitation program (among those who were admitted to the hospital belonging to the Labor Welfare Corporation) due to an industrial accident from August 2018 to September 2019 were collected. As a result, the records of 12 subjects meeting the screening criteria were analyzed. Results: According to the time of application to the intensive rehabilitation program, the 10 Meter Walk Test (10MWT) (p < 0.01), Berg Balance Scale (BBS) (p < 0.01), Timed Up and Go Test (TUG) (p = 0.01), the L Test of Functional Mobility (L-test) (p < 0.01), Prosthetic Limb Users Survey of Mobility (Plus-M) (p < 0.01), and Houghton Score Question (HSQ) (p < 0.01) values significantly improved with time. Conclusion: This study confirmed the positive effect of an intensive rehabilitation program on the gait, balance, functional performance, and wearing satisfaction of patients with traumatic lower extremity amputations caused by industrial accidents. However, this study was limited by the absence of a control group, and, thus, it highlights the need for more extensive research with a large sample.

Analysis of Topography and Ground Characteristics of Landcreep Reoccurrence in the Yangpyeong Area (양평지역 땅밀림 재발생지의 지형 및 지반 특성 분석)

  • Park, Jae Hyeon;Lee, Sang Hyeon
    • Journal of Korean Society of Forest Science
    • /
    • v.111 no.2
    • /
    • pp.263-275
    • /
    • 2022
  • We conducted this study to provide essential data for implementing restoration measures on the physical properties of the geology, topography, and soil of the landcreep areas in Yangpyeong-gun, Gyeonggi-do. The strata of the survey area comprised topsoil, weathered soil, weathered rock, and soft rock layers. The landcreep area, caused by colluvial debris, was located in a convex topography shape distributed as bedrock with shales and incorporated with sandstone. According to the measurement of the displacement meter, the surveyed area has crept from 1.1 mm to 6.5 mm during the recurrent landcreep between 1 July and 27 August, 2020. The landcreep had progressed over two directions (S65° W, E45° S, and E70° S) which were similar to the groundwater flow direction (E82.5° S and S16.8° W). The average slope of the landcreep area occurred on a gentle slope (19.3°), lower than the average slope of the mountain area (25°) in Korea. The bulk density in the groundwater areas was lower than that in other surveyed areas.

Current status of disposal and measurement analysis of radioactive components in linear accelerators in Korea

  • Kwon, Na Hye;Shin, Dong Oh;Kim, Jinsung;Yoo, Jaeryong;Park, Min Seok;Kim, Kum Bae;Kim, Dong Wook;Choi, Sang Hyoun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.507-513
    • /
    • 2022
  • When X-ray energy above 8 MV is used, photoneutrons are generated by the photonuclear reaction, which activates the components of linear accelerator (linac). Safely managing the radioactive material, when disposing linac or replacing components, is difficult, as the standards for the radioactive material management are not clear in Korea. We surveyed the management status of radioactive components occurred from medical linacs in Korea. And we also measured the activation of each part of the discarded Elekta linac using a survey meter and portable High Purity Germanium (HPGe) detector. We found that most medical institutions did not perform radiation measurements when disposing of radioactive components. The radioactive material was either stored within the institution or collected by the manufacturer. The surface dose rate measurements showed that the parts with high surface dose rates were target, primary collimator, and multileaf collimator (MLC). 60Co nuclide was detected in most parts, whereas for the target, 60Co and 184Re nuclides were detected. Results suggest that most institutions in Korea did not have the regulations for disposing radioactive waste from linac or the management procedures and standards were unclear. Further studies are underway to evaluate short-lived radionuclides and to lay the foundation for radioactive waste management from medical linacs.

Measurements of Neutron Activation and Dose Rate Induced by High-Energy Medical Linear Accelerator

  • Kwon, Na Hye;Jang, Young Jae;Kim, Jinsung;Kim, Kum Bae;Yoo, Jaeryong;Ahn, So Hyun;Kim, Dong Wook;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.145-152
    • /
    • 2021
  • Purpose: During the treatments of cancer patients with a linear accelerator (LINAC) using photon beams with energies ≥8 MV, the components inside the LINAC head get activated through the interaction of photonuclear reaction (γ, n) and neutron capture (n, γ). We used spectroscopy and measured the dose rate for the LINAC in operation after the treatment ended. Methods: We performed spectroscopy and dose rate measurements for three units of LINACs with a portable high-purity Germanium (HPGe) detector and a survey meter. The spectra were obtained after the beams were turned off. Spectroscopy was conducted for 3,600 seconds, and the dose rate was measured three times. We identified the radionuclides for each LINAC. Results: According to gamma spectroscopy results, most of the nuclides were short-lived radionuclides with half-lives of 100 days, except for 60Co, 65Zn, and 181W nuclides. The dose rate for three LINACs obtained immediately in front of the crosshair was in the range of 0.113 to 0.129 µSv/h. The maximum and minimum dose rates measured on weekends were 0.097 µSv/h and 0.092 µSv/h, respectively. Compared with the differences in weekday data, there was no significant difference between the data measured on Saturday and Sunday. Conclusions: Most of the detected radionuclides had half-lives <100 days, and the dose rate decreased rapidly. For equipment that primarily used energies ≤10 MV, when the equipment was transferred after at least 10 minutes after shutting it down, it is expected that there will be little effect on the workers' exposure.

Development of Autonomous navigation of Drones and Automatic measurement system for Surface velocity doppler radar (드론의 자율운항 및 전자파표면유속계 자동 측정 시스템 개발)

  • Lee, Tae Hee;Kang, Jong Wan;Jeong, Seung Gyo;Kim, Geon Woo;Lee, Ki Sung;Lee, Sin Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.90-90
    • /
    • 2022
  • 전자파표면유속계를 이용한 유량측정은 전자파를 발사한 후 수표면에 반사되는 전자파의 도플러효과를 이용하여 표면유속을 측정하는 방법이다. 국제적으로 1980년대부터 홍수유량측정의 어려움을 극복하고자 전자파표면유속계를 개발하여 하천 유량측정 업무에 활용하였다. 미국의 경우U.S. Geological Survey (USGS)에서 교량, 케이블웨이, 제방, 헬리콥터, 비행기 등 전자파표면유속계의 측정 위치에 따라 주파수 범위를 달리하며 유속을 측정하는 연구가 진행되었다. 국내의 경우 Lee et al.(2021)은 드론을 이용한 전자파표면유속계 측정을 위해 드론으로부터 전자파표면유속계로 전달되는 진동을 제거하고 전자파표면유속계의 흔들림 방지를 위한 댐퍼플레이트를 개발하여 드론과 전자파표면유속계를 결합한 DSVM(Dron and Surface Veloctity Meter using doppler radar) 측정방법에 대한 실용성을 확인하였다. 기존 연구에서 DSVM 방법은 드론의 각 측선 이동을 위한 조종 및 전자파표면유속계 측정의제어를 측정자가 수행하였는데 본 연구에서는 자동 측정 시스템 개발을 통해 측정자의 조종 의존도를 줄임과 동시에 안전하고 정확한 유량측정을 위해 노력하였다. 측정지점의 위치정보를 DB화하여 각 측선별 이동하는 자율운항 기능과 전자파표면유속계를 자동으로 제어하여 측정을 실시하는 기능을 개발하였다. 또한 전자파표면유속계 컨트롤 시스템과 GCS(Ground Control System)를 통합하여 한 시스템에서 측정의 모든 상황을 컨트롤 할 수 있게 하였다. 현재까지는 DSVM 방법의 자율운항 기능과 자동 측정 시스템의 테스트를 완료하였고 2022년 홍수기 유량측정에 도입하여 홍수기 유량측정의 실용성을 판단할 계획이다.

  • PDF

A Study on the Feasibility of Establishing a Joint Preservation Library for Chungcheongbuk-do Office of Education (충청북도교육청 공동보존자료관 설립타당성에 관한 연구)

  • Younghee Noh;Seung-Jin Kwak;In-ho Chang;Bong-suk Kang
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.34 no.4
    • /
    • pp.55-75
    • /
    • 2023
  • This study proposes the establishment of a joint preservation library in the Chungcheongbuk-do region. It aims to transfer low-utilization materials from various libraries in Chungcheongbuk-do to the joint preservation library, thereby improving the efficiency of existing spaces and actively supporting the educational curriculum of school libraries. To achieve this, the study conducted document analysis, a status survey, and case analysis. The research results indicate that a reasonable standard for the accommodating capacity of the preservation library space is calculated at 280 volumes per square meter. Specifically, an initial transfer of 45,580 volumes for public libraries and 121,894 volumes for school libraries is proposed, totaling 167,474 volumes. Depending on the saturation levels of Chungcheongbuk-do Office of Education-affiliated public libraries and school libraries, the initial volume is determined to be 167,477 volumes, with an annual increase of 10% calculated over 30 to 50 years after the library's opening.

Improvement of accuracy in radioactivity assessment of medical linear accelerator through self-absorption correction in HPGe detector

  • Suah Yu;Na Hye Kwon;Sang-Rok Kim;Young Jin Won;Kum Bae Kim;Se Byeong Lee;Cheol Ha Baek;Sang Hyoun Choi
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2317-2323
    • /
    • 2024
  • Medical linear accelerators with an energy of 8 MV or higher are radiated owing to photonuclear reactions and neutron capture reactions. It is necessary to quantitatively evaluate the concentration of radioactive isotopes when replacing or disposing them. HPGe detectors are commonly used to identify isotopes and measure radioactivity. However, because the detection efficiency is generally calibrated using a standard material with a density of 1.0 g/cm3, a self-absorption effect occurs if the density of the measured material is high. In this study, self-absorption correction factors were calculated for tungsten, lead, copper, and SUS-303, which are the main materials of medical linear accelerator head parts, for each gamma-ray energy using MCNP 6.2 code. The self-absorption effect was more pronounced as the energy of the emitted gamma rays decreased and the density of the measured materials increased. These correction factors were applied to the radioactivity measurements of the in-built and portable HPGe detectors. Furthermore, compared to the surface dose rate measured by the survey meter, the accuracy of the measurements of radioactivity improved by an average of 124.31 and 100.53 % for inbuilt and portable HPGe detectors, respectively. The results showed a good agreement, with an average difference of 3.70 and 5.24 %.

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

Consideration of Radioactive Contamination Materials Disposal (방사성오염물질 처분에 대한 고찰)

  • Im, Hyun-Jin;Kim, Tae-Yeob;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.128-132
    • /
    • 2010
  • Purpose: Nuclear medicine general operation room is radioactive control room which is used for the handling of radioisotope(R.I). Radioactive contamination materials must be under control and separated from general trash. With this experiments, we want to actively suggest the guideline of controling and operating radioactive contamination materials by measuring contamination degree and analyzing the causes which is not realized so far. Materials and Methods: Materials are selected from Oct. 2009 to March. 2010. salines which are used for labelling radiophamaceuticals and generator cap, saline needle cap, $^{99m}Tc$-needle cap saline vial which is generated from $^{99}Mo$/$^{99m}Tc$ generator. After measuring each surface contamination degree by survey meter, mean value and standard deviation one were solved out. Results: In result, After measuring surface contamination degree, radioactivity of saline for labelling radiophamaceuticals showed $14429{\pm}26378$ cpm (p<0.05) and in measured generators, foreign imported things showed that generator cap : $9{\pm}21$ cpm, saline vial : $17{\pm}28$ cpm. saline needle cap : $35{\pm}66$ cpm, $^{99m}Tc$-needle cap : $9{\pm}21$ cpm, saline vial $13{\pm}28$ cpm. domestic things showed that generator cap : $22852{\pm}52545$ cpm, saline needle cap : $87367{\pm}109711$ cpm, $^{99m}Tc$-needle cap : $9008{\pm}10459$ cpm, saline vial : $186416{\pm}158196$ cpm (p<0.05). Conclusion: The saline which is used for labelling, exceeded 1/10 of maximum permissible range. this is generated from radiophamaceuticals dilution procedure. and In generators, radioactive value of foreign import things showed closely background value. but which of domestic thing showed that exceeded more than 1000 values 1/10 of maximum permissible range. the causes of that is domestic generator is contaminated in manufacturing procedure. So, to dispose radioactive contamination materials which is could betaken out of, the control and operation must be radical under controlled by radioactive measuring, recording and equipping of its own. if this is kept well, we can prevent surely that radioactive waste could be disposed like as general trash.

  • PDF

The Evaluation of External Radiation Exposure dose rate for Radium-223 Dichloride (Radium-223 Dichloride의 외부 방사선량의 평가)

  • Cho, Seong Wook;Yoon, Seok Hwan;Seung, Jong Min;Kim, Tae Yub;Im, Jeong Jin;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.28-31
    • /
    • 2016
  • Purpose $^{223}Ra-Dichloride$ is used for the medicine of castration-resistant prostate cancer (CRPC) and which emits ${\alpha}-ray$ of 28 Mev that is used for therapy. However $^{223}Ra-Dichloride$ emits ${\beta}-ray$ of 3.6% and ${\gamma}-ray$ of 1.1%(80,156,270 keV) aside from ${\alpha}-ray$ in decay. Therefore we would like to evaluate external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$. Materials and Methods We calculated external radiation expose dose rate using ${\gamma}-constant$ of $^{223}Ra-Dichloride$, $^{99m}Tc$ based on Health physics(2012). $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq were applied. external radiation expose dose rate 15 times from 1m by survey meter. Results ${\gamma}-contant$ of $^{223}Ra$, $^{99m}Tc-MDP$ from 1m distance based on Health physics(2012) is 0.0469, 0.0215. calculated value of external radiation expose dose rate was $16{\mu}Sy$, $34{\mu}Sy$ which activity is $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq from 1 m and measured mean value of 1 m was $0.7{\mu}Sy/h$, $18{\mu}Sy/h$. Conclusion ${\gamma}-constant$ of $^{223}Ra$ is higher than $^{99m}Tc$ based on Health physics(2012). however calculated maximum external radiation expose dose rate of $^{223}Ra-Dichloride$ is lower than $^{99m}Tc$ due to actually used quantity of activity of $^{223}Ra-Dichloride$ is small. measured value of $^{223}Ra-Dichloride$ is also lower than $^{99m}Tc-MDP$. Therefore external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$ is very low.

  • PDF