• Title/Summary/Keyword: Surrounding air

Search Result 531, Processing Time 0.025 seconds

A Study on the Effective Controlling System of Radio-activity Ventilation (RI사용 의료기관의 효율적인 배기관리 방안)

  • Lee, Kyung-Jae;Lee, Jin-Hyung;Kim, Kyung-Hoon;Kwack, Dong-Woo;Jo, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.

  • PDF

A Study on the increase of space debris from Chinese Anti-Satellite and breach of the Outer Space Treaty (자국위성(自國衛星)의 파괴(破壞)에 따른 우주잔해의 증가와 우주조약위반(宇宙條約違反) 여부에 관한 소고(小考) - 중국의 자국위성파괴와 관련하여 -)

  • Kim, Sun-Ihee
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.28 no.2
    • /
    • pp.259-294
    • /
    • 2013
  • After its experiment involving the exploding of a satellite in space in 2007, China proudly aired news on TV and ran articles in newspapers. However, the event was internationally criticized and drew widespread attention. Many countries denounced the explosion by pointing out that it could be part of the nation's plan to expand its military power to space or that it could pose a danger to the peaceful use of space. However, there is no talk of whether the experiment that produced a huge amount of space debris could have violated an international law, namely the Outer Space Treaty. Although space garbage has been said to be a serious problem, the amount is still on the increase. If we continue to launch new space launch vehicles into orbit at this rate, we will not be able to use it anytime soon like we do today. As the commercial use of space is likely to increase, the situation will certainly get worse. The international community is fully aware of the seriousness of the problem and working together to reduce the amount of space garbage. However, despite the fact that the United States and Soviet Union's ASAT(Anti-Satellite) programs have been implemented for a long time, there have been no complaints about them in terms of military expansion or breach of the Outer Space Treaty. Also, the recent Chinese test is largely viewed to be in accordance with international law. A lot of research has been undertaken with regard to the problem of space garbage. Now people's awareness of dangers being posed has been fully raised. Under the circumstances, the dismissing of China's satellite smashing, leaving a big mess in its wake, as nothing more than an experiment, is a red flag to, if not many, at least some people. By means of this thesis, I would like to review whether the Chinese test has violated an international space law. This thesis presents an overview of the issues surrounding the event and examines the possibility of violating the Outer Space Treaty, formally the Treaty on Principle Governing the Activities of States in the Exploration and Use of Outer Space, Including the Moon and Other Celestial Bodies. After the China test, the UN Scientific and Technical Subcommittee first adopted space debris mitigation guidelines, I'll introduce the content of the guidelines and discuss the characteristics of the guidelines and what can be done to address the issue.

  • PDF

A Proposal of Direction of Wind Ventilation Forest through Urban Condition Analysis - A Case Study of Pyeongtaek-si - (도시 여건 분석을 통한 바람길숲 조성방향 제시 - 평택시를 사례로 -)

  • SON, Jeong-Min;EUM, Jeong-Hee;SUNG, Uk-Je;BAEK, Jun-Beom;KIM, Ju-Eun;OH, Jeong-Hak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.4
    • /
    • pp.101-119
    • /
    • 2020
  • Recently, as a plan to improve the particulate matter and thermal environment in the city, urban forests acting as wind ventilation corridor(wind ventilation forest) are promoted nationwide. This study analyzed the conditions for the creation of wind ventilation forest(vulnerable areas of the particulate matter and thermal environment, distribution of wind ventilation forest, characteristics of ventilation corridor) of in Pyeongtae-si, one of the target cities of wind ventilation forest project. Based on the results, the direction of developing on the wind ventilation forest in Pyeongtaek-si was suggested. As a result of deriving areas vulnerable to particulate matter and thermal environment, it was most vulnerable in urban areas in the eastern area of Pyeongtaek-si. Especially, emissions were high from industrial complexes and roads such as the Pyeongtaek-si thermal power plant, ports, and the national road no. 1. The wind ventilation forest in Pyeongtaek-si was distributed with small-scale windgenerating forests, wind-spreading forests, and wind-connection forests fragmented and disconnected. The characteristic of the overall wind ventilation corridor in Pyeongtaek-si is that the cold air generated from Mt.Mubong, etc., strongly flowed into Pyeongtaek-si and flowed in the northwest direction. Therefore, it is necessary to preserve and expand the wind-generating forests in Pyeongtaek-si in the long term, and it was important to create wind-spreading forests and wind-connection forests so that cold air could flow into the vulnerable area. In addition, in industrial complexes and roads where particulate matter is generated, planting techniques should be applied to prevent the spread of particulate matte to surrounding areas by creating wind-spreading forests considering the particulate matter blocking. This study can be used not only as the basis data for wind ventilation forest project in Pyeongtaek-si, but also as the basis data for urban forest creation and management.

A Comparative Study of Landscape Characteristics on Bridges in Palaces of Korea and China - Focusing on the Chosun Dynasty and Ming and Qing Dynasties - (한국과 중국의 궁궐 내 교량에 관한 경관특성 비교 연구 - 조선시대와 명·청시대를 중심으로 -)

  • Zhang, Fu-Chen;Lee, Ai-Ran
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.1-12
    • /
    • 2019
  • A bridge is a structure constructed on water or in the air for convenient passage. Compared to other buildings, the building materials and structures of bridge required unique functions to cross the space. It depends on the productivity of the building, the level of science and technology, and the ecological environment of the building site. Also, it has important relationship with functions such as politics, military, economy, and life. Most of the academic research on bridges is focused on research in the field of bridge-building technology, so the study on the landscape aesthetics and history of bridges is lacking. Against this backdrop, the study will be valuable as a accumulation of both countries' understanding of bridge types, history and culture, as well as technical and aesthetic data, by analyzing the bridges located within the palaces of Korea and China. The research method is to analyze the bridge through field survey and literature analysis.. First, the bridges of royal palace of Korea and China are to be classified quantitatively as physical shapes, landscapes, and decorations by comparing the materials, forms, landscapes, and decorative culture of bridges. Second, characteristics, common points, and differences are extracted by classifying bridges of both countries. Also, the results are discussed based on the physical environment or cultural background. This would be worth cross-referencing in the building technology and aesthetics of the two countries. For the first important characteristics of result, main materials of Korean and Chinese palaces are stone. However, the bridge in China's royal palaces is also focused on wood. Second, in terms of form, the bridges in the royal gardens of Korea and China are all based on the beam bridge. However, the specific form, ratio, style of the beam bridge, and airspace of arched bridge are very different. Third, most of the connection methods are focused on the over bridge. It values the convergence with the surrounding landscape. Due to the difference in the area and location of water, the bridge in the Korean palace is more focused on the convergence of the surrounding buildings and plants, while the bridge in the Chinese palace is more concerned about the harmony of hydration. Fourth, the decoration places importance on the artistry and aesthetics of both the bridges in Korea and China. There is a difference in style in the same type of decoration due to culture.

A Case Study on the Health Impact Assessment of Residential Development Projects (주거지 개발사업에 대한 건강영향평가 사례 연구)

  • Shin, Moonshik;Dong, Jongin;Ha, Jongsik
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.5
    • /
    • pp.391-402
    • /
    • 2020
  • Health Impact Assessment based on municipal law is performed and written in the sanitary and public health part in the current environmental impact assessment. Residential development projects such as housing site development etc., are not subject to health impact assessment under Article 13 of the Environmental Health Act. However, health impact assessment is conducted partially based on the review that health impact assessment targets which are identified among substances emitted from pollutants nearby industrial complexes should be assessed risk (including carcinogenic and non-carcinogenic) at the stage of the environmental impact assessment consultation. Although residential development projects do not have plans for pollutant emitting facilities that emit hazardous air pollutants, there is a possibility that residents might be affected by pollutants from industrial complex near residential area in the future. In this study, Health impact assessment was conducted to examine the impact on residents in planned areas by analyzing previous residential development projects. We predicted future impact by using the literature survey results on surrounding area (case1) and conducting contribution analysis (case2) and predicting exposure concentration of carcinogenic substances applying Atmospheric Diffusion Model (AERMOD). By this study, we concluded that applying on-site survey, contribution analysis and prediction of exposure concentration by using AERMOD complementarily will be effective to assess the health impact to the receptors by pollutants from industrial complexes near the planned zone.

A Case of Bronchus-Associated Lymphoid Tissue(BALT) Lymphoma Treated with Lobectomy (폐엽절제를 통한 BALT 림프종 치료 1 예)

  • Choi, Won Sub;Cho, Jae Hyun;Hwang, Young Il;Jang, Seung Hun;Kim, Dong-Gyu;Jun, Sun-Young;Min, Kwangseon;Lee, In Jae;Lee, Jae Woong;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.5
    • /
    • pp.427-431
    • /
    • 2007
  • The bronchus-asociated lymphoid tissue(BALT) lymphoma is a low-grade primary malignant lymphoma that originates from bronchus associated lymphoid tissue. A 67-year-old woman was admitted for evaluation of cough, sputum, rhinorrhea which had persisted for one month. Physical examination showed decreased breathing sound on the left upper lung field. High resolution chest computed tomography demonstrated consolidation which showed air-bronchogram and surrounding ground glass opacity in left upper lobe. These findings implicated inactive tuberculosis, organizing pneumonia, or bronchiolo-alveolar carcinoma. The histologic findings from percutaneous needle aspiration biopsy revealed aggregated atypical small lymphoid cells with lymphoepithelial lesions. With immunohistochemical staining, the atypical lymphoid cells reacted positively with CD 20 antibody and negatively with CD 3 antibody. Thus, we could diagnosed her as a patient with BALT lymphoma. After left upper lobectomy, she has been well without recurrence of the disease for 14 months. In this country of Republic of Korea, it was the 1st case of BALT lymphoma surgically treated when histological diagnosis had been done. Based on this case, we wanted to demonstrate the importance of early histological diagnosis and treatment of BALT lymphoma.

A Study on the Relationship Between Length of Time and Contamination in Open Intravenous Solutions (정맥주사용 수액의 개방후 시간경과에 따른 오염도에 관한 실험연구)

  • 김일원
    • Journal of Korean Academy of Nursing
    • /
    • v.16 no.1
    • /
    • pp.67-80
    • /
    • 1986
  • The use of intravenous solutions for fluid replacement has become an integral part of patient care, This widespread use of intravenous solutions has increased the risk of contamination that can lead to septicemia and phlebitis. The literature regarding contamination of in use intravenous solutions recommends a standard 24-hour time limit on the use of these fluids. But the desings of these studies did not incorporate a time variable related to contamination. In other studies, however, time was a manipulated variable: but data regarding the onset of contamination were conflicting. Because published reports conflict with regard to a time standard related to the use of intravenous therapy, additional empirical data are needed upon which to base the standards of care regulating use of intravenous therapy. This study investigated rate of contamination in simulated in-use intravenous solutions to obtain data from which to recomend a standard time period for the administration of intravenous solutions. In this study samples were drawn from 60 bottles of 5% D/W solution at predetermined time intervals over 48 hours and samples were inoculated to Thio-glychollate Broth. After 10 days' culturing in that Broth, samples were cultured on blood agar plates for 18∼48 hours to determine the rate of contamination. was found at all time Period, regardless of the presence or absence of nurse's gloving in the preparation of fluids, the location in which the experimentations were performed, the contamination level of surrounding air, or the length of time during which solutions were opened. Data from this study support the use of a 48-hour time period on which to base the standard involved in ready-to-use simple intravenous solutions without additives. In emergency departments and critical care areas where intravenous solutions are prepared in advance, the suggested time standard supported by the data generated from this study is 48 hours, not 24 hour. Data from this study support a 24-hour time standard for changing in-use intravenous solutions when the contamination results from the manipulation of intravenous infusion system by hospital personnel, or from some other exogenous sources during administration. Because contamination that does occur within 48 hours in intravenous solutions must be introduced from some exogenous sources, further empirical studies based on the identification of sources of contamination and factors that affect the rate of contamination, are needed to investigate the currently employed standard of intravenous therapy and to provide the patient with more efficient and safer intravenous thereapy.

  • PDF

Design and Implementation of a Power-Saving Management System using Intelligent Scheduler based on RFID/USN Technology (RFID/USN 기술 기반의 지능형 스케줄러를 이용한 절전관리 시스템 설계 및 구현)

  • Jeong, Kyu-Seuck;Choi, Sung-Chul;Jeong, Woo-Jeong;Kim, Tae-Ho;Kim, Jong-Heon;Seo, Dong-Min;Park, Yong-Hun;Yoo, Jae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.64-76
    • /
    • 2009
  • Recently, the ubiquitous environment and the practical technology associated with it become more popular topic along with the rapid development of wireless technologies. The necessity of the automated system based on the ubiquitous environment has been increasing when the concept of the ubiquitous is integrated into the fields of existing IT. Also, the necessity of formulating a power-saving plan on large buildings and public institutions is gathering strength because of a raise in exchange rates and high oil prices. In this paper, to efficiently manage the power consumption of the electronic machine such as electric lights, electric heaters, and air conditioners in a building, power-saving manage- ment system using RFID/USN technologies is proposed. Proposed system controls the electric machine and monitor it's condition by RFID and collects the real time information about the surrounding and the power consumption of the electric machine by USN. Especially, proposed system analyzes the real time information and supports the intelligent scheduler with the best power-saving. Finally, this paper shows the difference between proposed system and existing system and establishes thereality of our system through experiments in variety environments.

Thoracoscopic Sympathectomy for a Patient with Facial Hyperhidrosis -A case report- (흉강경하 흉부교감신경절제술을 이용한 안면다한증 치료 -증례보고-)

  • Moon, Dong-Eon;Park, Byung-Cheul;Kim, Byung-Chan;Kim, Sung-Nyeon
    • The Korean Journal of Pain
    • /
    • v.9 no.2
    • /
    • pp.399-402
    • /
    • 1996
  • Endoscopic transthoracic sympathectomy (ETS) has recently become estabilished as a successful treatment for severe palmar and axillary hyperhidrosis. Descriptions have been published of neurolytic, operative and alternative endoscopic procedures involving thermocoagulation, laser coagulation, or or nonvideo-assisted ganglionectomy using equipment not widely available, with low morbidity and excellent results. All methods have advantage and disadvantages. A 19-year-old male who suffered from severe hyperhidrosis on face, palms and axillary areas, has been initially treated with stellate ganglion block in other pain clinic. He was transfered to our pain clinic for endoscopic thoracic sympathectomy. The patient was intubated left side 34 Fr. double lumen tube and positioned left semi-lateral position for right sympathectomy. Right side pneumothorax was created by clamping the ipsilateral side of the double lumen tube and aspiration of air. 11-mm trocar was introduced through incision at the third intercostal space in anterior axillary line, and then additional two 11-mm and 5-mm trocar was introduced through second and fifth intercostal space in mid axillary line. The lung was gently retracted and the parietal pleura over the heads of the appropriate ribs excised using 5-mm sharp insulated coagulating microprocesss. The T4, T3, and T2 ganglions, as well as accompanying rami communicantes, and other branchs arising from upper thoracic nerves to the brachial plexus and surrounding tissues were carefully dissected, coagulated. During sympathectomy, skin temperature of middle was continuously monitored. Elevation of palmar skin temperature intraoperatively indicated an adequate sympathectomy with a definite therapeutic effect. A No. 28 Fr. thoracotomy tube was introduced through a troca under video guidance, placed under water seal after the lung was reinflated. the controlateral side was performed same procedure. After bilateral sympathectomy, chest tubes were removed, and then, he was discharged 2 days after operation with great satisfaction. The ETS provides a well-tolerated, cost-effective alternative to thoracic sympathectomy for primary hyperhidrosis and sympathetic mediated neuropathic pain disorder. And T2 ganglion is considered the key ganglion for the treatment of primary hyperhidrosis. The low incidence of compensatory sweating may by explained by the limited extent of the sympathectomy.

  • PDF

A Study on the Thermo-Flow Analysis of Air Conditioning Electric Compressor Motor System for Hybrid Electric Vehicles (하이브리드 자동차 에어컨용 전동식 압축기 모터 시스템의 열유동 해석 연구)

  • Kim, Sung Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.592-597
    • /
    • 2013
  • The heat generated at the motor and inverter inside the electric compressor of inverter built-in type is mainly cooled by refrigerant and generally, there is not a thermal problem. However, the close relation of heat transfer from the motor and inverter parts to the compression part affects on compressor efficiency. Also, according to the surrounding environment and system operation condition, the increased temperature of the motor and inverter can affect the power density of the motor system, and especially, the inverter may be prevented to operate by the temperature limits. In this study, we performed thermo-flow analysis of electric compressor motor system, and investigated the heat dissipation enhancement of the motor and inverter. The motor part in the operation region of the electric compressor was generally maintained at low temperature and the inverter part at high compressor speed was lower temperature than the temperature limit of $85^{\circ}C$. However, the case of the inverter at low speed harsh condition was in excess of $10^{\circ}C$. Therefore, in order to solve the thermal problem, the heat reduction technology of the motor and inverter is essential as well as the improvement of flow path in the compressor.