• 제목/요약/키워드: Surgical material

검색결과 727건 처리시간 0.033초

Bowel Obstruction Due to Less-Digestible Pet Food with No Shadowing on Ultrasonography in a Small-Breed Puppy

  • Junyoung Kim;Jihye Choi;Junghee Yoon
    • Journal of Veterinary Clinics
    • /
    • 제41권2호
    • /
    • pp.127-132
    • /
    • 2024
  • A 6-month-old intact female Bichon Frise dog weighing 0.9 kg presented with vomiting, anorexia, and lethargy persisting for 3 days. No remarkable abnormalities were detected on the history or physical examination. Laboratory findings were mostly normal, except for elevated levels of alkaline phosphatase (ALP) and blood urea nitrogen (BUN). Abdominal radiography revealed a fluid-dilated stomach and gas-dilated intestinal loops in the regional areas. Abdominal ultrasonography was performed to investigate the cause of gastrointestinal dilation, which revealed a rectangular, homogeneous, echogenic foreign material with no shadowing in the small intestine, causing mechanical obstruction. Upon further inquiry involving detailed re-take of history with the owner, a history of ingesting dog gum 4 days prior was identified. On surgical enterotomy, the hard pet food was identified and removed from the distal duodenum. Postoperatively, the patient's clinical signs showed complete improvement, with a return to normal appetite. The present case demonstrates that less-digestible, hard pet food, despite showing no shadowing on ultrasonography, can act as a foreign material, causing mechanical intestinal obstruction in a small-breed puppy. Furthermore, surgical removal of these materials is necessary in cases of intestinal obstruction.

Design and Evaluation of Ultrasonic Bone Surgical Instruments for Dental Application (치과용 초음파 골수술기 설계 및 평가)

  • Lee, Joo-Hee;Oh, Jung-Min;Hong, Younwoo;Kim, Seiki;Paik, Jonghoo;Lee, Young-Jin;Lee, Jeong-Bae;Lee, Seung-Dae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제25권12호
    • /
    • pp.990-995
    • /
    • 2012
  • A piezoelectric ultrasonic bone surgical instrument, usually used to remove the tartar out of teeth or to cut the dentine of the tooth, is a recently popular instrument for dental treatment due to its several merits such as small size, low-electric power and precision control of surgical operation. It has typically two parts of a tip and vibration system which is also composed of head, piezoelectric elements and tail-mass. In order to improve the performance of the instrument, it is important to standardize the size of the vibration system without tip for high performance. In this study, a Finite Element Analysis (FEA) was utilized to optimize the structure of ultrasonic instrument in vibration system. Consequently, this study revealed that influence of several tips on property were minimized and it showed good property at the frequency range of 22~32 kHz.

Do Certain Conditions Favor the Use of Autogenous Bone Graft Over Bone Substitutes for Maxillary Sinus Augmentation?

  • Lee, Ji-Hyun;Cho, Yeong-Cheol;Sung, Iel-Yong;Choi, Jong-Ho;Son, Jang-Ho
    • Journal of Korean Dental Science
    • /
    • 제12권2호
    • /
    • pp.48-57
    • /
    • 2019
  • Purpose: To investigate whether there are specific surgical or clinical conditions where the use of autogenous bone (AB) is superior to the use of bone substitutes (BSs) for maxillary sinus floor augmentation (MSFA). Materials and Methods: We retrospectively analyzed 386 implants after MSFA in 178 patients. The implants were divided into five groups according to the sinus graft material used. Risk factors for implant failure in MSFA, and correlation between residual bone height (RBH) and graft materials in terms of implant survival were investigated. To investigate risk factors for implant failure in MSFA, implant survival according to graft materials, patients' sex/age, surgical site, RBH, healing period prior to prosthetic loading, staged- or simultaneous implantation with MSFA, the crown-to-implant ratio, prosthetic type, implant diameter, and opposite dentition were evaluated. Result: The cumulative 2- and 5-year survival rates of implants placed in the grafted sinus (independent of the graft material used) were 98.7% and 97.3%, respectively. None of the investigated variables were identified as significant risk factors for implant failure. There was also no statistical significance in implant survival between graft materials. Conclusion: There were no specific surgical conditions in which AB was superior to BSs in terms of implant survival after MSFA.

THE USE OF MEDPORTM(POROUS HIGH-DENSITY POLYETHYLENE) IN ORAL AND MAXILLOFACIAL REGION (구강악안면영역에서의 MedporTM의 임상적용)

  • Park, Gwang-Bum;Yeo, Hwan-Ho;Kim, Su-Gwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제21권1호
    • /
    • pp.60-64
    • /
    • 1999
  • Recently, for the reconstruction of bony defect and cosmetic improvement, many graft materials and implants have been widely used in the various surgical situations. The alloplastic materials have many advantages such as simplicity of operation, no additional need of surgery, and easy manipulation. The $Medpor^{TM}$(porous high-density polyethylene, Porex Co., USA) was initially studied in 1972 for surgical implant and introduced as an implant material for oral and maxillofacial region by Sauer and King in 1988. This material permits full ingrowth of bone into the implants, substantially increasing the implant's incorporation into the recipient site. It can be shaved during the surgery, which results in an improvement and prefabricated various size and shapes to fit into the surgical defect. The $Medpor^{TM}$ was used in 32 patients from 1995 to 1997 at the maxillofacial region. It was used for paranasal augmentation in 24 cases, for malar augmentation in 2 cases, for infraorbital augmentation in 2 cases, for mandibular angle augmentation in 2 cases, for mandibular body augmentation in 2 cases, for chin vertical augmentation in 1 case. It was mainly fixed with miniplate or screw. There were few complications except one infection and one exposure of the implant.

  • PDF

Validation of a Cognitive Task Simulation and Rehearsal Tool for Open Carpal Tunnel Release

  • Paro, John A.M.;Luan, Anna;Lee, Gordon K.
    • Archives of Plastic Surgery
    • /
    • 제44권3호
    • /
    • pp.223-227
    • /
    • 2017
  • Background Carpal tunnel release is one of the most common surgical procedures performed by hand surgeons. The authors created a surgical simulation of open carpal tunnel release utilizing a mobile and rehearsal platform app. This study was performed in order to validate the simulator as an effective training platform for carpal tunnel release. Methods The simulator was evaluated using a number of metrics: construct validity (the ability to identify variability in skill levels), face validity (the perceived ability of the simulator to teach the intended material), content validity (that the simulator was an accurate representation of the intended operation), and acceptability validity (willingness of the desired user group to adopt this method of training). Novices and experts were recruited. Each group was tested, and all participants were assigned an objective score, which served as construct validation. A Likert-scale questionnaire was administered to gauge face, content, and acceptability validity. Results Twenty novices and 10 experts were recruited for this study. The objective performance scores from the expert group were significantly higher than those of the novice group, with surgeons scoring a median of 74% and medical students scoring a median of 45%. The questionnaire responses indicated face, content, and acceptability validation. Conclusions This mobile-based surgical simulation platform provides step-by-step instruction for a variety of surgical procedures. The findings of this study help to demonstrate its utility as a learning tool, as we confirmed construct, face, content, and acceptability validity for carpal tunnel release. This easy-to-use educational tool may help bring surgical education to a new- and highly mobile-level.

Spinal Cord Tumors : An Analysis of 654 Cases(1973-1999) (척수 종양 654예의 임상 분석(1973-1999))

  • Choe, Woo Jin;Chung, Chun-Kee;Cho, Byung-Kyu;Kim, Hyun Jib
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권8호
    • /
    • pp.1004-1012
    • /
    • 2001
  • Objective : The spinal cord tumors(including vertebral tumors) are increasingly diagnosed and operated due to development of refined diagnostic and therapeutic tools. It is necessary to re-evaluate clinical features and surgical results of spinal cord tumors with increasing cases and developing treatment modalities. The authors reviewed the spinal cord tumor cases to evaluate their clinical characteristics. Material and Methods : The retrospective review of 654 cases of spinal cord tumors between 1973 and 1999 was done. The clinical features, pathological analysis and surgical results were analyzed and compared to the literature. The results of the study are analyzed with a more detailed consideration of each of major pathologies : neurogenic tumors, meningeal tumors, neuroepithelial tumors, and metastatic tumors. Results and Conclusion : The spinal cord tumor was most common in the 5th decade of age(145 cases, 22.1%) and 78 cases(11.9%) were found in children under 15 years of age. The ratio of male to female was 1.2 : 1. The pathologic diagnosis was neurogenic tumor in 266 cases(40.7%), neuroepithelial tumor in 131(20.0%), metastatic tumor in 118(18.0%), and meningeal tumor in 94(14.4%) in the order of frequency. The tumor was located most frequently in the thoracic area(36.5%) and in the intradural extramedullary space(38.1%). The most common initial presentation was pain(40.1%) and the mean duration for presentation to operation was 14.8 months. The total or gross total removal was possible in 404 cases(61.7%) and the surgical result on the postoperative one month was recovery or improvement in 424 cases(64.8%), stationary in 188(28.7%), progression in 42(6.4%). As a surgical complication, there was a spinal deformity(12 cases), wound infection(5 cases), aspiration pneumonia(5 cases) etc. Neurogenic tumors and menigiomas showed good surgical results, whereas neuroepithelial tumors(except ependymoma) and metastatic tumors showed relatively poor prognosis.

  • PDF

Application of the New Surgical Technique for Orthotopic Heart Transplantation in Dogs (잡견에 있어서 새로운 심장수술기법의 적용)

  • 원태희;한재진;김기봉;노준량
    • Journal of Chest Surgery
    • /
    • 제33권3호
    • /
    • pp.207-211
    • /
    • 2000
  • Backgroud: Conventional cardiac transplantation with each atrial anastomosis designed by Shumway and associates has been used widely in cardiac transplantation because of its simplicity and efficiency. There have been many reports about the postoperative atrioventricular value regurgitation resulting from the alteration in atrial geometry after cardiac transplantation by Shumway's technique. New surgical technique of direct anastomosis of superior vena cava, inferior vena cava, right pulmonary vein and left pulmonary vein was introduced to overcome the those problems. We performed this study to test the feasibility of this new surgical technique prior to application to clinical practice. Material and Method: Conventional cardiac transplantation was performed on 12 mongrel dogs(Group I) and cardiac transplantation with new surgical mthod of direct anastomosis of SVC, IVC, left and right pulmonary veins was performed on 11 mongrel dogs(Group II). After weaning from cardiopulmonary bypass, we compared the postoperative rhythm, hemodynamic data, and echocardiographic findings between two groups. Result : The cardiopulmonary bypass time and graft ischemic time were 119.0$\pm$4.4 minutes, 162.0$\pm$4.5 minutes respectively in group I, and 140.0$\pm$7.1 minutes, 180.5$\pm$5.4 minutes respectively in group II. The cardiopulmonary time and graft ischemic time in group II were longer than those of group I (p<0.05). There were 3 cases of failure to weaning from cardipulmonary bypass onein group I and two in group II, and this difference was not significant statistically. Sinus rhythm was regained postoperatively in 58% (group I) and 82%(group II), without statistical significant between 2 groups. Postoperative echolcardiography showed 2 cases of tricuspid value regurgitation and 1 case of mitral regurgitation in group I, and no regurgitation of atrioventricular value in group II. Conclusion: Although these was no statistically significant difference between 2 groups, there was tendency of less arrhythmia and less atrioventricular valvular regurgitation in group II. We suggested that the new surgical technique could be a useful strategy in heart transplantation, especially in the case of size mismatching between donor and recipient.

  • PDF

Surgical Treatment of Cardiac Tumor (심장에 발생한 종양의 수술적 치료)

  • Jung, Tae-Eun;Han, Sung-Sae;Lee, Dong-Hyup
    • Journal of Chest Surgery
    • /
    • 제39권11호
    • /
    • pp.810-814
    • /
    • 2006
  • Background: Tumors of the heart are uncommon. The aim of this study is to review our clinical experience and outcome of surgical treatment of cardiac neoplasm. Material and Method: From March 1990 to December 2005, 35 patients(14 males and 21 females) with mean age of 52.4 years underwent surgical treatment of cardiac neoplasm. The clinical and pathologic data were analyzed retrospectively. Surgical treatment consisted in complete resection of the tumor in all cases but 1 patient who was left ventricular fibroma received biopsy only. Result: Thirty cases were benign and five cases were malignant tumor. Benign tumors were myxoma(29 cases) and fibroma(1 case). Five malignant tumors were osteosarcoma, hepatocellular carcinoma, renal cell cancer, yolk sac tumor, and unclassified myxoid spindle cell type sarcoma. There were no operative mortality in benign cases and twenty seven cases of myxoma were followed up for 8 months to 15 years without recurrence. But four patients of malignant tumor were expired within six months after operation. Conclusion: Left atrial myxomas are most common benign neoplasm. Surgical treatment is effective for the benign cardiac tumors but prognosis is poor in patients with malignant cardiac tumors.

A Multi-detection Fluorescence Dye with 5-ALA and ICG Using Modified Light Emitting Diodes

  • Yoon, Kicheol;Kim, Eunji;Kim, Kwanggi;Lee, Seunghoon;Yoo, Heon
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.256-262
    • /
    • 2019
  • Extensive tumor resection accompanied by radiotherapy and chemotherapy is the standard of care for malignant gliomas. However, there is a significant obstacle to the complete resection of the tumor due to the difficulty of distinguishing tumor and normal brain tissue with a conventional surgical microscope. Recently, multiple studies have shown the possibility of fluorescence-guided surgery in malignant gliomas. The most used fluorescence dyes for brain tumor surgery are 5-aminolevulinic acid (5-ALA) and indocyanine green (ICG). In this paper, a new fluorescence guided operation system, which can detect both 5-ALA and ICG fluorescent images simultaneously, is presented. This operation system consists of light emitting diodes (LEDs) which emits 410 nm and 740 nm wavelengths. We have performed experiments on rats in order to verify the operation of the newly developed operation system. Oral administration and imaging were performed to observe the fluorescence of 5-ALA and ICG fluorescence in rats. When LEDs at wavelengths of 410 nm and 740 nm were irradiated on rats, 628 nm wavelength with a violet fluorescence color and 825 nm wavelength with a red fluorescence color were expressed in 5-ALA and ICG fluorescent material, respectively, thus we were able to distinguish the tumor tissues easily. Previously, due to the poor resolution of the conventional surgical microscope and the fact that the color of the vein is similar to that of the tumor, the tumor resection margin was not easy to observe, thus increasing the likelihood for cancer recurrence. However, when the tumor is observed through the fluorescence guided operation system, it is possible to easily distinguish the color with the naked eye and it can be completely removed. Therefore, it is expected that surgical removal of cancerous tumors will be possible and surgical applications and surgical microscopes for cancer tumor removal surgery will be promising in the future.

Particle Filtration Efficiency Testing of Sterilization Wrap Masks

  • Chau, Destiny F.;O'Shaughnessy, Patrick;Schmitz, Michael L.
    • Journal of Preventive Medicine and Public Health
    • /
    • 제54권1호
    • /
    • pp.31-36
    • /
    • 2021
  • Objectives: Non-traditional materials are used for mask construction to address personal protective equipment shortages during the coronavirus disease 2019 (COVID-19) pandemic. Reusable masks made from surgical sterilization wrap represent such an innovative approach with social media frequently referring to them as "N95 alternatives." This material was tested for particle filtration efficiency and breathability to clarify what role they might have in infection prevention and control. Methods: A heavyweight, double layer sterilization wrap was tested when new and after 2, 4, 6, and 10 autoclave sterilizing cycles and compared with an approved N95 respirator and a surgical mask via testing procedures using a sodium chloride aerosol for N95 efficiency testing similar to 42 CFR 84.181. Pressure testing to indicate breathability was also conducted. Results: The particle filtration efficiency for the sterilization wrap ranged between 58% to 66%, with similar performance when new and after sterilizing cycles. The N95 respirator and surgical mask performed at 95% and 68% respectively. Pressure drops for the sterilization wrap, N95 and surgical mask were 10.4 mmH2O, 5.9 mmH2O, and 5.1 mmH2O, respectively, well below the National Institute for Occupational Safety and Health limits of 35 mmH2O during initial inhalation and 25 mmH2O during initial exhalation. Conclusions: The sterilization wrap's particle filtration efficiency is much lower than a N95 respirator, but falls within the range of a surgical mask, with acceptable breathability. Performance testing of non-traditional mask materials is crucial to determine potential protection efficacy and for correcting misinterpretation propagated through popular media.