• Title/Summary/Keyword: Surgical material

Search Result 725, Processing Time 0.024 seconds

Surgical treatment for dysesthesia after overfilling of endodontic material into the mandibular canal (하치조신경관으로 과충전된 근관치료 충전재에 의한 감각이상의 외과적 처치)

  • Song, Jae-Min;Kim, Yong-Deok;Lee, Jae-Yeol
    • The Journal of the Korean dental association
    • /
    • v.54 no.11
    • /
    • pp.874-879
    • /
    • 2016
  • Damage to the inferior alveolar nerve(IAN) is a relatively infrequent complication in endodontic treatment. However, endodontic overfilling involving the mandibular canal may cause an injury of the inferior alveolar nerve resulting in sensory disturbances such as pain, dysesthesia, paresthesia or anesthesia. Two mechanism(chemical neurotoxicity and mechanical compression) are responsible for the IAN injury. When absorbent materials overfilled, it can be treated as a non-surgical procedure. But early surgical intervention required when mechanical, chemical nerve damage expected. We report surgical removal of overfilled gutta-percha and IAN decompression through sagittal split osteotomy in case of dysesthesia after overfilling of endodontic material into the mandibular canal. Dysesthesia recovered 3 months after surgical treatment.

  • PDF

Surgical stent for dental implant using cone beam CT images (콘빔형 전산화단층영상을 이용한 치과임플란트 식립유도장치 개발)

  • Choi, Hyung-Soo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.171-178
    • /
    • 2010
  • Purpose : The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Materials and Methods : Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Results : Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. Conclusion : The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

A Study on Wearing and Manufacturing of Surgical Gowns (수술가운의 생산 및 착용현황에 관한 연구)

  • 박상희
    • Journal of the Korean Society of Costume
    • /
    • v.54 no.3
    • /
    • pp.65-71
    • /
    • 2004
  • Surgical operating gowns are worn by doctors and nurses in operating theater to address dual function of preventing transfer microorganisms like bacteria and body fluids from the operating staffs to patients. and also from patients to staff. They must allow necessary mobility without rubbing and must resist tearing. These gown must be designed to fit a diversity of body shapes and sizes with a limited range of sizes as hospitals will stock limited quantities. Also they must proper in various operating situations. In order to suggest improving design features of surgical gowns, it has been done to analyze current situation of medical uniform manufacturing and wearing. Surgical gown were made with plain fabric of cotton 100% and had a little size system without sexual division. Many doctors were unsatisfied with surgical gown size and wearing comfort. Surgical operating gowns need continuos research for new material and design as surgical situation, and new sizing system.

Thyroplasty Type I using Gore-Tex (고어텍스를 이용한 제1형 갑상연골성형술)

  • Yoo, Young-Sam
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.18 no.1
    • /
    • pp.16-21
    • /
    • 2007
  • Many kinds of materials have been used up to now for vocal fold paralysis. Although silastic block has been the most popular material, some difficulties in carving, positioning, and placing have been the causes to find more easily applicable materials. Hy-droxylapatite, gelfoam, hyaluronic acid and fat have been suggested and used for this purposes with some limitations. During last decade, Gore-Tex was introduced and replacing old materials and showed good surgical results with less difficulties. This material is biocompatible and familiar to surgeons because it had been invented in 1960's. In addition it is easy to shape and place Gore-Tex into the window with many clinical experiences. In some problem cases, it is easy to remove from the body with less damage to surrounding tissue. The basic surgical techniques are as follows. 1) Creating window. 2) Positioning and placing the material. 3) Immobilizing the material and closing the window. The modified methods ae introduced in details with figures.

  • PDF

Secondary bone grafting for alveolar clefts: surgical timing, graft materials, and evaluation methods

  • Kim, Junhyung;Jeong, Woonhyeok
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.2
    • /
    • pp.53-58
    • /
    • 2022
  • Alveolar cleft belongs to the spectrum of cleft lip and/or palate, affecting 75% of cleft lip/palate patients. The goals of alveolar cleft treatment are stabilizing the maxillary arch, separating the nasal and oral cavities, and providing bony support for both erupting teeth and the nasal base via the piriform aperture. Secondary alveolar bone grafting is a well-established treatment option for alveolar cleft. Secondary alveolar bone grafting is performed during the period of mixed dentition using autologous bone from various donor sites. There are several issues relevant to maximizing the success of secondary alveolar bone grafting, including the surgical timing, graft material, and surgical technique. In this study, we reviewed issues related to surgical timing, graft materials, and evaluation methods in secondary alveolar bone grafting.

고분자 미립구를 사용한 비뇨기과, 성형외과적 주사 요법용 생체 재료 개발

  • Jo, Ui-Ri;Gang, Seon-Ung;Kim, Byeong-Su
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.591-594
    • /
    • 2003
  • In the present study, we developed a filling material composed of poly(lactic-co-glycolic) acid (PLGA) microspheres with applications in the treatment of facial wrinkle and urinary incontinence and studied the feasibility of injecting the filling materials in animal models for plastic surgical and urological applications. Former filling materials including Teflon, Silicon, and collagen have shown a few shortcomings such as inflammation reaction, particles migration or volume decrease. We injected PLGA microspheres into the subcutaneous dorsum of mice. Injected volume was constantly maintained after implanting. We hardly found either inflammation reaction or migration. This material overcomes the problems of the current filling materials and could be utilized as a new filling material for plastic surgical and urological applications.

  • PDF

Development of skin surgical machine by series resonance method (직렬공진에 의한 피부 수술기 개발)

  • Lee, Oh-Keol;Kim, Sang-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.127-132
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows. Therefore, this treatise developed electricity living body formation operation appliance by home production. Ultra high frequency eruption circuit used LC circuit. and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current. This developed product could microscopic operation fewer than 1 [mm]. This development technology is considered by do metallic surface heat treatment, melting, welding, induction heating device and that can apply to domestic animals surgical operation and so on.

  • PDF

The Surgical Management of Aspirated Foreign Bodies in Airways (기도내 이물의 외과적 처치에 관한 연구)

  • Kim, Ju-Hyeon;Kim, Sam-Hyun
    • Journal of Chest Surgery
    • /
    • v.14 no.4
    • /
    • pp.331-338
    • /
    • 1981
  • The inhalation of a foreign body into the tracheobronchial tree is a child is a life-threatening accident. Forgotten foreign bodies In the airways cause chronic pulmonary infections, allergic asthma, bronchiectatic changes, and lung abscess Foreign bodies that cannot be grasped by bronchoscopic forceps should be removed by thoracotomy and bronchotomy. This report describes our experience In 16 patients who were treated to remove inhaled foreign bodies from the airways after repeated bronchoscopies had been unsuccessful from 1963 to 1981 at the department thoracic surgery of Seoul National University Hospital. The surgical procedures are as follows: 12 patients bronchotomy, 2 patient pneumonectomy, 2 patients lobectomy. In these cases, the foreign bodies are 8 metallic material, 3 plastic material, 1 bean, 1 black snail, and 3 cases of no records. Bronchotomy must be performed as soon as possible in order to avoid more advanced pathologic changes In the Involved lung, such as bronchiectasis, fibrosis or abscess.

  • PDF

Study on the Conservative Treatment of Herniated Lumbar Intervertebral Disc (요추 추간판탈출증의 보존적 치료에 관한 연구)

  • Song, Bong-Keun
    • The Journal of Korean Medicine
    • /
    • v.16 no.2 s.30
    • /
    • pp.62-78
    • /
    • 1995
  • In industrialized countries, low back pam is very common, with up to 60 to 80% of the population being affected at some time in their lives. Herniated lumbar intervertebral disc is one of principal cause of low back pain and radiculopathy. The therapy of the disease is classified into conservative treatment or surgical intervention. The majority of these cases successfully heal with conservative managemant, even though it was claimed that the henirated disc material would not resolved spontaneously without surgical removal. It was reported that there was no significant difference in outcome and cost effectiveness between conservative and surgical therapy group. Also after conservative therapy the resorption of herniated disc with satisfactory improvement of symptom was reported. Conservative treatment includes bed rest, heat, drug therapy, therapeutic exercises, physical therapy such as traction and manipulation, and acupuncture. These managements show favorable outcome in the patients with herniated lumbar intervertebral disc. So conservative management should be applied in the therapy of herniated intervertebral disc, unless there exist aggravation during the first 3 weeks of treatment or apparent surgical care indication. And further investigation to improve effectiveness of conservative therapy should be ensued.

  • PDF

Octacalcium phosphate, a promising bone substitute material: a narrative review

  • Jooseong Kim;Sukyoung Kim;Inhwan Song
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.1
    • /
    • pp.4-12
    • /
    • 2024
  • Biomaterials have been used to supplement and restore function and structure by replacing or restoring parts of damaged tissues and organs. In ancient times, the medical use of biomaterials was limited owing to infection during surgery and poor surgical techniques. However, in modern times, the medical applications of biomaterials are diversifying owing to great developments in material science and medical technology. In this paper, we introduce biomaterials, focusing on calcium phosphate ceramics, including octacalcium phosphate, which has recently attracted attention as a bone graft material.