• Title/Summary/Keyword: Surge protective device

Search Result 63, Processing Time 0.03 seconds

Design and Behavior of Validating Surge Protective Devices in Extra-low Voltage DC Power Lines (특별저전압 직류 전원회로에 유용한 서지방호장치의 설계와 특성)

  • Shim, Seo-Hyun;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.81-87
    • /
    • 2015
  • In order to effectively protect electrical and electronic circuits which are extremely susceptible to lightning surges, multi-stage surge protection circuits are required. This paper presents the operational characteristics of the two-stage hybrid surge protection circuit in extra-low voltage DC power lines. The hybrid surge protective device consists of the gas discharge tube, transient voltage suppressor, and series inductor. The response characteristics of the proposed hybrid surge protective device to combination waves were investigated. As a result, the proposed two-stage surge protective device to combination wave provides the tight clamping level of less than 50V. The firing of the gas discharge tube to lightning surges depends on the de-coupling inductance and the rate-of-change of the current flowing through the transient voltage suppressor. The coordination between the upstream and downstream components of the hybrid surge protective device was satisfactorily achieved. The inductance of a de-coupler in surge protective circuits for low-voltage DC power lines, relative to a resistance, is sufficiently effective. The voltage drop and power loss due to the proposed surge protective device are ignored during normal operation of the systems.

Study On The Protective Effect of Lightning Surge for Electronic Equipments According to Installation Methods of Surge Protective Device (서지보호소자의 설치방식에 따른 기기의 뇌보호효과 검토)

  • Lee, Suck-Woo;Whang, Kyu-Hyun;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.616-619
    • /
    • 2004
  • Lightning surge damages of low voltage equipments in building are increasing due to increase in electrical and communication networks in the information-oriented society. And electronic equipments contained electrical circuits with semiconductor are very weak against lightning surge. The surge protective devices for electronic circuit in electronic equipments and AC power lines are becoming more widely. To achieve effective method of surge protection, there are needs for correlation between lightning surge protective effect of electronic equipment and installation method of surge protective device. This paper describes as a result of experiments for correlation between lightning surge protective effect and installation method of surge protective device.

  • PDF

The Protection Effect of Lightning Surge for electronic Equipments According to Installation of Surge Protective Device and Earth Leakage Breaker (서지보호소자와 누전차단기 설치에 따른 기기의 뇌보호 효과)

  • Lee, Suck-Woo;Ko, Yeon-Sung;Yeo, Dong-Goo;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.90-92
    • /
    • 2005
  • Lightning surge damages of low voltage equipments in building are increasing due to increase in electrical and communication networks in the information-oriented society. And electronic equipments contained electrical circuits with semiconductor are very weak against lightning surge. The surge protective devices for electronic circuit in electronic equipments and AC power lines are becoming more widely. To achieve effective method of surge protection, there are needs for correlation between lightning surge protective effect of electronic equipment and installation method of surge protective device. This paper describes as a result of experiments for correlation between lightning surge protective effect and installation of surge protective device and Earth Leakage Breaker.

  • PDF

Discussion On The Protective Effect of Lightning Surge based on The Surge Protective Devices for Low Voltage (저압 피뢰기 적용시 뇌서지 억제 효과 검토)

  • Lee, Suck-Woo;Whang, Kyu-Hyun;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.40-42
    • /
    • 2004
  • Electronic equipments made from electrical circuits with small-sized semiconductor are very weak against lightning surge. So, electronic equipments is protected by SPD(surge protective devices) such as Zno varistor. The SPD protect electronic circuit in electronic equipments and AC power lines from the lightning surge. Therefore to achieve effective method of surge protection, there are needs for correlation between lightning surge protective effect and installation method of surge protective device. Therefore this paper describes as a result of experiments for correlation between lightning surge protective effect and installation method of surge protective device.

  • PDF

Surge Protective Device Combined with Varistor and LC Filter on AC Power Circuits (바리스터와 LC필터를 조합한 교류 전원용 서지보호장치)

  • 이복희;이경옥;안창환;이승칠;박정웅
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.4
    • /
    • pp.109-116
    • /
    • 1997
  • This paper describes the surge protective device combined with varistor and LC low pass filter on AC power circuits. Up to now varistors alone have been used as a surge protective device on AC power circuits, but it gives negative effects on the equipments to be protected due to the steep rise and high remnant voltage. Therefore in this work, for the purpose of improving the cutoff performance of surge protective device on AC power circuits, the hybrid-type surge protective device with varistor and LC filter was designed and prepared. And the experiments for operational characteristics and clamping performance of the surge protective device were carried out with an 1.2/50[$\mu$s] impulse generator. As a result, the proposed surge protective device with the combination of varistors and LC filter can limit the surge voltage to lower value and reduce the value of dV /dt to very small values. Also the attenuation of high-frequency voltages across the output port is effectively provided by LC filter. Therefore this result may be all the more helpful avoiding both damage and upset of electronic systems.

  • PDF

Protection coordination between residual current device and surge protective devices in low-voltage consumer's installations (저압 수용가 설비에서 누전차단기와 서지방호장치 사이의 보호협조)

  • Lee, Bok-Hee;Kim, Hoe-Gu;Park, Hee-Yeoul;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.75-81
    • /
    • 2013
  • In this paper, protection coordination between residual current devices and surge protective devices in low-voltage consumer's distribution systems are presented. In the case that a surge protrctive device(SPD) is located on the load side of an residual current device(RCD), when the surge is injected from the source side of the RCD, most of injected surge currents are split into the RCD and the protection coordination between the SPD and RCD is improper, three of 6 specimens experience unintended operation due to test impulse currents. Also when the surges is injected from the load side, a lot of the surge currents is split into the SPD, but a half of test specimens causes nuisance trip. Coordination between SPD and RCD is not valid. When installing SPD, it is important to select SPD after due consideration of the protection voltage level of metal oxide varistor embedded in RCD. It is expected that the results obtained from this work could be useful to improve the protection effects of SPD in low-voltage distribution systems.

The Ligthning Surge Protective Devices with Combination of Varistor and LC Filter (바리스터와 LC필터를 조합한 뇌써-지보호장치)

  • Kim, J.H.;Lee, K.O.;Lee, B.H.;Lee, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1873-1875
    • /
    • 1996
  • This paper deals with the lightning surge protective devices with combination of varistor and LC filter. UP to now, the varistor alone were used as overvoltage protection devices fer the AC power mains. In this work, in order to improve the cutoff performance of surge protective device, the hybrid circuit surge protective device for an AC single phase mains was designed and investigated. The first stage of hybrid circuit is to remove most of any large surge energy and protect the second stage components. The purpose of the second is to protect the load and increase the cutoff capacity of surge protective devices. Also LC filter attenuates the remnant that travels downstream from the first stage component and the high frequency noises. As a consequence, it was found that the proposed hybrid surge protective device for AC power mains has a variety of advantages such as low and tight clamping voltage, high frequency noise reduction and large cutoff capacity.

  • PDF

Development of Integrity Evaluation Instrument for the Power Line Surge Protective Device (전원용 SPD의 건전성 평가 장치 개발)

  • Chang, Sughun;Kim, Youngjin;Kim, Sungju;Kim, Jaehyung
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.39-45
    • /
    • 2015
  • This paper deals with development of integrity evaluation instrument for the power line surge protective device. A reliable power supply is an essential element in the developed information and communication society by highly advances in IT technology. However, the lightning incidence also increased with the recent extreme weather events. In Korea, in order to protect the electrical system from lightning surge, SPD(Surge Protective Device) has been used for these past 30 years. However, the method of diagnosing the safety of the SPD in the industry is insufficient. In this paper, SPD integrity evaluation system was composed of a variable DC power source unit, voltage-current sensor and the embedded controller. In order to measure V-I characteristics of MOV, 3 type samples were degraded by impulse current generator. After impulse tests, the varistor voltage of all samples and nonlinearity coefficient were decreased. It confirmed the utility of the developed equipment by this experimental test and the reliability of SPD is expected for surge accident prevention when applied to industrial plant.

Two-Stage Surge Protection Device with Varistor and LC Filter. (바리스터와 LC필터를 사용한 2단 서지보호장치)

  • Lee, B.H.;Kim, J.H.;Lee, K.O.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.279-281
    • /
    • 1996
  • This paper deals with the two stage surge protection device by using varistor and LC low pass filter. Recently varistor alone has been used with overvoltage protection devices for the AC power mains and has same problems associated with high remnant voltage and noise. In this work, in order to improve the cutoff performance of surge protection device, the lightning surge protection device having two stage hybrid circuit for an AC single phase mains was designed and fabricated. Operation characteristics and surge clamping performance of the surge protection device in an $8/20{\mu}s$ surge current are investigated. As a consequence, it is found that the proposed two stage surge protective device for AC power mains has a variety of advantages such as a smaller clamping voltage, high frequency noise reduction and large clamping capacity.

  • PDF

The study of method and verification that Surge protective devices connected to low-voltage power systems of the thermal stability test (전원용서지보호장치(Surge protective devices connected to low-voltage power systems)의 열안전성시험(Thermal stability test)의 방법 및 판단에 대한 고찰)

  • Choi, Gil;Park, Shin-Woo;Lim, Byung-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1213-1214
    • /
    • 2015
  • 서지보호장치(Surge Protective Device)가 국내에 본격적으로 설치된 것은 산업화의 발전으로 인해 현장 전력시스템의 복잡성과 다양성 및 급격히 변화하고 있는 우리나의 기후변화 때문일 것이다. 전원계통의 전원용서지보호장치(Poser Systems Surge Protective Devices) 및 통신계통의 통신용서지보호장치(Telecommunication Surge Protective Devices)의 설치는 해마다 증가하고 있다. 이에 따른 제품개발도 급속도로 이루어지고 있으며, 과거 몇년 전만해도 서지보호장치에 대한 표준과 시험설비의 이해와 부족으로 인해 표준에 의한 제품검증이 어려웠으나 2013년 제정된 KS 표준(KS C IEC 61643-11)으로 상당수 제조자가 관련인증을 취득하고 있다. 이 논문에서는 KS표준에서 정의하고 있는 열안전성시험에 대한 방법과 결과판정 및 새로운 기준을 제시하고자 한다.

  • PDF