• Title/Summary/Keyword: Surface protector

Search Result 29, Processing Time 0.029 seconds

A Study on the Effect of Optical Characteristic in 2 inch LCD-BLU by Negative and Positive Optical Pattern :I. Optical Analysis and Design (휴대폰용 2 인치 LCD-BLU의 광특성에 미치는 음각 및 양각 광학패턴의 영향 연구 :I. 광학 해석 및 설계)

  • Hwang C.J.;Ko Y.B.;Kim J.S.;Yoon K.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.75-76
    • /
    • 2006
  • LCD-BLU (Liquid Crystal Display - Back Light Unit) is one of kernel parts of LCD unit and it consists of several optical sheets(such as prism, diffuser and protector sheets), LCP (Light Guide Plate), light source (CCFL or LED) and mold frame. The LGP of LCD-BLU is usually manufactured by forming numerous dots with $50{\sim}200{\mu}m$ in diameter on it by erosion method. But the surface of the erosion dots of LGP is very rough due to the characteristics of the erosion process during the mold fabrication, so that its light loss is high along with the dispersion of light into the surface. Accordingly, there is a limit in raising the luminance of LCD-BLU. In order to overcome the limit of current dot patterned LGP, optical pattern design with $50{\mu}m$ micro-lens was applied in the present study. Especially, the negative and positive micro-lens pattern fabricated by modified LiGA with thermal reflow process was applied to the optical design of LGP. The attention was paid to the effects of different pattern conditions to the brightness distribution of BLU with micro-lens patterned LGP. Finally, negative micro-lens patterned LGP showed superior results to the one made by positive in average luminance.

  • PDF

A Study on the Indirect Radiation Exposure of the Medical Personnel Who is Responsible for Patient Safety in CT Examination (전산화단층촬영검사 시 검사실 내에 위치할 수 있는 의료인의 간접 피폭선량에 대한 연구)

  • Choi, Min-Hyeok;Jang, Ji-Sung;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.105-111
    • /
    • 2019
  • A medical personnel could be placed beside a patient together in CT room to do Ambu-bag for a seriously ill patients or emergency patient. At this time, the medical personnel can be exposed indirect radiation unnecessarily. In this case, it is necessary to recognize indirect radiation dose levels and methods to reduce them using actual clinical CT protocols such as Chest, Abdomen, and Brain CT. We researched surface radiation dose with or without radiation protectors such as apron and goggles according to different distances far from gantry using two different CT scanners (Fixed MDCT and mobile CT). As a result, for Chest, Abdomen, and Brain CT with Fixed MDCT, indirect radiation dose on thorax portion were 0.047, 0.089, 0.034 mSv without apron. Also, those with apron were 0.007, 0.012, 0.006 mSv. In case of mobile CT, it was 0.014 mSv without apron and 0.005 mSv with apron. By using protectors and increasing the distance, we could reduce it to 97%. Systematic management is necessary based on the measured data in order to minimize radiation damage due to indirect exposure dose.

A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance (콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구)

  • Jang, Seo-Yong;Kim, Jong-Ryeol;Shin, Yun-Sup;Ma, Bong-Duk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.163-170
    • /
    • 2006
  • Recently, piezocone penetration test is frequently used in order to estimate the characteristics of soft ground with standard penetration test, generally used in the past. In this study, the correlation of standard penetration test, piezocone penetration test and driving resistance of vertical drain is analyzed in order to increase the confidence for determination of soft ground depth. As the results of each zone, the relation between standard penetration test and piezocone penetration test shows qc=(1.09~1.63)N at the soft ground, determined by 5/30 N value which is decided for soft ground criteria. And qc=(1.21~1.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. And driving resistance of vertical drain is $65{\sim}70kgf/cm^2$ which is equal to $10kgf/cm^2$ of cone penetration resistance.

The effect of different fluoride application methods on the remineralization of initial carious lesions

  • Byeon, Seon Mi;Lee, Min Ho;Bae, Tae Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.121-129
    • /
    • 2016
  • Objectives: The purpose of this study was to assess the effect of single and combined applications of fluoride on the amount of fluoride release, and the remineralization and physical properties of enamel. Materials and Methods: Each of four fluoride varnish and gel products (Fluor Protector, FP, Ivoclar Vivadent; Tooth Mousse Plus, TM, GC; 60 Second Gel, A, Germiphene; CavityShield, CS, 3M ESPE) and two fluoride solutions (2% sodium fluoride, N; 8% tin(ii) fluoride, S) were applied on bovine teeth using single and combined methods (10 per group), and then the amount of fluoride release was measured for 4 wk. The electron probe microanalysis and the Vickers microhardness measurements were conducted to assess the effect of fluoride application on the surface properties of bovine teeth. Results: The amount of fluoride release was higher in combined applications than in single application (p < 0.05). Microhardness values were higher after combined applications of N with FP, TM, and CS than single application of them, and these values were also higher after combined applications of S than single application of A (p < 0.05). Ca and P values were higher in combined applications of N with TM and CS than single application of them (p < 0.05). They were also increased after combined applications of the S with A than after single application (p < 0.05). Conclusions: Combined applications of fluoride could be used as a basis to design more effective methods of fluoride application to provide enhanced remineralization.

A Study on Improvement of Submarine Attack Periscope Operation Performance using Installing Protector on Sail (잠수함 공격잠망경 함교 보호구조물 설치를 통한 장비 운용성능 향상에 관한 연구)

  • Choi, Woo-Seok;Chang, Ho-Seong;Lee, Young-Suk;Kim, Sang-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.199-206
    • /
    • 2021
  • This paper describes the feasibility and reliability verification of installing a protective structure to protect attack periscopes. The attack periscope is the critical equipment of a submarine to enable the user to monitor surface and air activity, collect navigational data, and detect and identify targets. The attack periscope provides target information acquired through TV, IR camera, and laser range finder to the combat system. In the product improvement program, the upper part of the masts was exposed to the outside of the sail because the existing attack periscope was replaced with a new one. On the other hand, the head sensor can be damaged by floating objects, such as fishing nets, during sea navigation. Therefore, the installation of a protective structure for an attack periscope improved the equipment operation performance. The feasibility and reliability of the installation of the protective structure were verified by examining the influence of URN.

Elemental analysis of the fluoride varnish effects on root caries initiation (불소 바니쉬 도포 후 초기 치근 우식 발현에 대한 정량원소분석)

  • Park, Se-Eun;Yi, Kee-Wook;Kim, Hae-Young;Son, Ho-Hyun;Chang, Ju-Hea
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.290-299
    • /
    • 2011
  • Objectives: The usage of fluoride varnish for a moderate to low caries-risk group has not been well validated. This study aimed to evaluate the preventive and therapeutic efficacies of fluoride varnish on the initiated root caries. Materials and Methods: Ten premolars were sectioned into quarters, further divided into two windows, one of which was painted with Fluor Protector (1,000 ppm fluoride, Ivoclar Vivadent). An initial lesion with a well-preserved surface layer was produced by pH cycling. Scanned line analysis using energy dispersive spectrometry determined the weight percentages of Ca and P in the demineralized layer. Scanning Electron microscopy and confocal laser scanning microscopy (CLSM) evaluated the varnish-applied root surfaces. Results: The mean lesion depth (SD) was 12.3 (2.6) ${\mu}m$ (single cycling) and 19.6 (3.8) ${\mu}m$ (double cycling). Double cycling extended the lesion depth, but induced no more mineral loss than single cycling (p < 0.05). The mean weight percentages of Ca and P between groups with and without varnish were not significantly different (p < 0.05). A CLSM showed varnish remained within 15 ${\mu}m$ of the surface layer. Conclusions: When a mild acid challenge initiated root tissue demineralization, the application of low-concentration fluoride varnish did not influence the lesion depth or the mineral composition of the subsurface lesion.

Analysis of Counting Rate according to Presence or Absence of Detector's Protector in Beta-rays Measurement using Geiger-Muller Counter (Geiger-Muller 계수관을 이용한 베타선측정에서 디텍터 보호유무에 따른 계수율 분석)

  • Jang, Ji-Yong;Jeong, Moon-Taeg;Song, Jong-Nam;Ha, Jae-Jun;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.31-37
    • /
    • 2018
  • In the surface contamination test using the end-window Geiger-Muller type counter, the wrap is used as a method for protecting the detector exposed to the outside in order to measure the beta-rays. We analyze the effect of this method on the measurement rate and the correction factor, and wanted to make it clear to radiation workers that excessive use of the wrap can affect the measured value of the beta-rays. The experimental method was to compare and analyze the change of the beta-rays measurement counting rate and the calibration factor according to the wrap thickness using the beta-rays with different energy of 3 KBq, 1.5 KBq and 0.3 KBq. The subjects of this study were the end-window Geiger-Muller type counter which were held at the calibration center certified by Korea Laboratory Accreditation Scheme (KOLAS) in March 2012, Cl-36 (Chlorine) and Sr-90 (Strontium) were used as the source of beta radiation. The measurement counting rate decreased with increasing wrap thickness, and the calibration factor increased with increasing wrap thickness. Since the changes of the measurement counting rate and the calibration factors can reduce the accuracy of the instrument readings, but also have a significant impact on detector contamination and damage, so there is a need to find out what thickness of wrap is most effective. If we using a wraps with thickness that show a low rate of change of the measurement counting rate and the calibration factor, it will protect the detector and minimize the effect on the measured value of the beta-rays.

Analysis of the Sports Injury in the Taekwondo Matches (태권도 경기 중 스포츠 손상에 대한 분석)

  • Her, Jin-Gang;Kim, Kwang-Soo
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.5 no.1
    • /
    • pp.75-80
    • /
    • 1999
  • The Taekwondo being a martial sports, there are higher chances for the injury to occur than the non martial sports. Therefore, this study analyze the frequency, the area, the type, and the condition of the injury which are prone to occur in the Taekwondo matches; it is to help the Taekwondo players in prevention of the injury and in treatment. The subjects of this study were the 48 players (male 24, female 24) who participated in the final selection contest of the national team player on March 9 to 12, 1993. The data of the injury were obtained from the medical recoder staff and were analyzed to the frequency of the injury per match, the vulnerable area of the injury, the type of injury, and the condition of the injury with a gender difference. There were 24 matches for the male and 24 matches for the female, total 48 matches. Therefore, the total participation number of the players are the double of the match number. 1. The frequency of the injury per match was 18.3%(11/60) for male and 23.1%(12/52) for women. 2. The areas of the injury were ankle 36.4%(4), foot 18.2%(2), knee 18.2%(2), lower leg 18.2%(2), wrist 9.1%(1) in male; foot 33.4%(4), ankle 16.7%(2), knee 16.7%(2), lower back 16.7%(2), lower leg 8.3%(1), face 8.3%(1) in female. 3. The types of the injury were contusion 45.5%(5), sprain 27.3%(3), abrasion 9.1%(1), laceration 9.1%(1), tendon rupture 9.1%(1) in male; contusion 33.3%(4), sprain 33.3%(4), abrasion 16.7%(2), subcutaneous hemorrhage 8.3%(1), dislocation 8.3%(1) in female. 4. The condition of the injury were the unblocked attack 36.4%(4), attacking kick 27.3%(3), blocking a kick 18.2%(2), attacking punch 9.1%, impact with surface 9.1%(1) in male; attacking kick 33.3%(4), unblocked attack 25%(3), blocking a kick 25%(3), attacking punch 8.3%(1), impact with surface 8.3%(1) in female. This study shows that the injury from the Taekwondo matches occurred most in the lower extremity joints and the foot, and shows that the most of the injury types were contusion and sprain. Therefore, it is believed to be helpful to wear the proper fitting ankle or the knee protector and using other protective equipment to prevent the sports injury in the Taekwondo matches.

  • PDF

An Inquiry into the Iron Seated Buddha Excavated from Pocheon in the National Museum of Korea (국립중앙박물관 소장 포천 출토 철조여래좌상에 대한 소고)

  • Kang, Kunwoo
    • MISULJARYO - National Museum of Korea Art Journal
    • /
    • v.96
    • /
    • pp.209-223
    • /
    • 2019
  • The Iron Seated Buddha sculpture in the National Museum of Korea had long sat unregistered in storage at the museum. However, a new accession number "bon9976" has recently been assigned to it. This sculpture was excavated from the neighborhood of Heungnyongsa Temple in Baekun-ri, Yidong-myeon, Pocheon-gun, Gyeonggi-do Province together with another Iron Seated Buddha sculpture(bon9975) called "Iron Buddha from Pocheon." A comparison and examination of Gelatin Dry Plate and official documents from the Joseon Government-General Museum during the Japanese occupation period have revealed that these two Iron Buddha sculptures were transferred to the Museum of the Government-General of Korea on December 17, 1925. The Iron Seated Buddha sculpture(bon9976) has a height of 105 centimeters, width at the shoulders of 57 centimeters, and width at the knee of 77 centimeters. The Buddha is wearing a robe with rippling drapery folds and the right shoulder exposed. He is seated in the position called gilsangjwa(the seat of good fortune) in which the left foot is placed over the right thigh. The features of the Buddha's oval face are prominently sculpted. The voluminous cheeks, eye sockets in a large oval shape, slanted eyes, short nose, and plump lips can also be found in other ninth-century Iron Seated Buddha sculptures at Silsangsa Temple in Namwon, Jeollanam-do Province, Hancheonsa Temple in Yecheon, Gyeongsangbuk-do Province, and Samhwasa Temple in Donghae-si, Gangwon-do Province. Moreover, its crossed legs, robe exposing the right shoulder, and rippling drapery folds suggest that this sculpture might have been modeled after the main Buddha sculpture of the Seokguram Grotto from the eighth century. The identity of this Iron Seated Buddha can be determined using the Gelatin Dry Plate(M442-2, M442-7). In them, the Buddha has its right palm facing upwards and holds a medicine jar on its left palm. Until now, the Iron Seated Bhaiṣajyagura(Medicine) Buddha(bon1970) excavated from Wonju has been considered the sole example of an iron Medicine Buddha sculpture. However, this newly registered Iron Seated Buddha turns out to be a Medicine Buddha holding a medicine jar. Furthermore, it serves as valuable material since traces of gilding and lacquering clearly remain on its surface. This Iron Seated Buddha sculpture (bon9976) is presumed to have been produced around the ninth century under the influence of Esoteric Buddhism by the Monk Doseon(827~898), a disciple of the Monk Hyecheol, to protect the temple and help the country overcome geographical shortcomings. According to the records stored at Naewonsa Temple(later Heungnyongsa Temple), Doseon selected three significant sites, including Baegunsan Mountain, built "protector" temples, created the Bhaisajyagura Buddha triad, and enshrined them at the temples. Moreover, the inscription on the stele on the restoration of Seonamsa Temple states that Doseon constructed temples and produced iron Buddha sculptures to help the country surmount certain geographical shortcomings. Heungnyongsa Temple is located in Dopyeong-ri, Yidong-myeon, Pocheon-si, Gyeonggi-do Province. This region appears to have been related to rituals directed to the Medicine Buddha since Yaksa Temple(literally, "the temple of medicine") was built here during the Goryeo Dynasty, and the Yaksa Temple site with its three-story stone pagoda and Yaksadong Valley still exist in Dopyeong-ri.