A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance

콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구

  • 장서용 (전남대학교 토목공학과) ;
  • 김종렬 (전남대학교 토목공학과) ;
  • 신윤섭 (유신코퍼레이션 지반공학부) ;
  • 마봉덕 (전남대학교 토목공학과)
  • Received : 2006.04.21
  • Published : 2006.09.30

Abstract

Recently, piezocone penetration test is frequently used in order to estimate the characteristics of soft ground with standard penetration test, generally used in the past. In this study, the correlation of standard penetration test, piezocone penetration test and driving resistance of vertical drain is analyzed in order to increase the confidence for determination of soft ground depth. As the results of each zone, the relation between standard penetration test and piezocone penetration test shows qc=(1.09~1.63)N at the soft ground, determined by 5/30 N value which is decided for soft ground criteria. And qc=(1.21~1.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. And driving resistance of vertical drain is $65{\sim}70kgf/cm^2$ which is equal to $10kgf/cm^2$ of cone penetration resistance.

최근 피조콘시험은 과거 일반적으로 사용되었던 표준관입시험과 함께 연약지반의 특성을 평가하기 위해 빈번히 사용되고 있다. 본 연구에서는 하부지반의 지층상태를 파악하고 설계를 위한 연약지반 심도 결정 및 시공시 수직배수재 타설심도 결정시 그 신뢰도를 향상시키기 위해서 표준관입시험결과, 선행압밀하중, 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치와의 관계를 분석하였다. 대상 지역별로 일정한 표준관입저항치를 기준으로 평균 연약지반심도를 결정하여, 동일한 심도에서 피조콘관입저항치를 값을 분석한 결과 qc=(1.09~1.63)N, 선행압밀하중을 고려한 결과 qc=(1.21~1.98)N의 관계를 나타내었다. 또한 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치(qc)와의 관계를 분석한 결과 평균적으로 피조콘 관입저항치 $10kgf/cm^2$의 경우 수직배수재 타설 시 관입저항치는 약 $65{\sim}70kgf/cm^2$ 의 값을 나타내었다.

Keywords

References

  1. 한국지반공학회, "지반조사 결과의 해석 및 이용", 1994, pp 61-72.
  2. Campanella, R. G., Robertson, P. K., "Current Status of the Piezocone Testing", 1st International Conference on Penetration Testing, Disney World, 1998, pp.112-121.
  3. Davidson, J. L. & Boghrat, A., "Displacement and strains around probes in sand", ASCE Special Conference on Geotechnical Practice in Offshore Engineering, Austin, Texas, 1983, pp.181-203.
  4. Douglas, B. J. & Olsen, R. S., "Soil Classification using electric cone penetrometer. Cone penetration testing and experience", Proceeding of the ASCE National Convention, St. Louis, ASCE, 1981, pp.209-227.
  5. Lunne, T., Robertson, P. K., & Powell, J. J., "Cone Penetration Testing in Geotechnical Practice", Blackie Academic & Professional. 1997, pp.98-145.
  6. Lutenegger, A. J. & Kabir, M., "Dilatometer C-reading to help determine stratigraphy", Proceedings of the 1st International Symposium on Penetration Testing, ISOPT-1, Orlando, Florida, Vol. 1, 1988, pp.549-554.
  7. Schmertmann, J. H., "Guidelines for cone penetration test, performance and design", US Federal Highway Administration, Washington, DC, Report, FHWA- TS-78-209, 1978, pp.145-190.
  8. Senneset, K., & Janbu, N., "Shear Strength Parameters obtained from Static CPT", Strength Testing of Marine Sediments(STP 883), R. C. Chaney and K. R. Demars, ed, ASTM, Philadelphia, 1985, pp.41-54.