• Title/Summary/Keyword: Surface plate

Search Result 2,492, Processing Time 0.031 seconds

Quality Characteristics of Aerobic Packed Pork during Storage after Fermentation with Soy Sauce, Red Pepper and Soybean Paste Seasonings (간장, 고추장 및 된장 양념으로 발효시킨 함기포장 돈육의 저장기간 동안 품질 특성)

  • Jin, S.K.;Kim, I.S.;Hah, K.H.;Lyou, H.J.;Park, K.H.;Lee, J.R.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.679-690
    • /
    • 2005
  • This study was carried out to evaluate the quality characteristics of aerobic packed pork during storage after fermentation with soy sauce, red pepper and soybean paste seasonings. The ham of pork were cut to cube($7{\time}10{\time}2$cm) and Korea traditional seasonings such as soy sauce(T1), red pepper paste(T2), soybean paste(T3) were seasoned by the proportions of meat to seasonings(1:1), respectively. The seasoned sample were fermented by fill into plastic box at $1{\pm}1^{\circ}C$ for 10 days. And then, the fermented meat from each pack was aerobic packed and stored at $1{\pm}1^{\circ}C$ for up to 28 days. The pH of T1 were significantly(P<0.05) lower compared to T2 and T3 at 1 day of storage, but were significantly(P<0.05) higher at 14 and 28 days of storage. The water-holding capacity of T1were significantly(P<0.05) higher compared to T2 and T3 at 1 and 28 days of storage. The shear force of T3 were significantly(P<0.05) lower compared to T1 during storage. The surface meat L* values of T3 were significantly(P<0.05) higher than those of T1 and T2, but a* and b* values of T2 were significantly(P<0.05) higher. The volatile basic nitrogen(VBN) of T3 were significantly(P<0.05) lower compared to T2 at 1 and 14 days of storage, but T1 were significantly(P<0.05) lower at 28 days of storage. The thiobarbituric acid reactive substances(TBARS) of T3 were significantly(P<0.05) lower compared to T1 and T2. The total plate counts of T1 were significantly(P<0.05) lower compared to T2 and T3 at 1 day of storage, but T2 were significantly(P<0.05) lower at 14 and 28 days of storage. The Escherichia coli of T1 and T3 were significantly(P<0.05) lower compared to T2 at 1 day of storage. The Lactobacilli spp. of T2 were significantly(P<0.05) lower compared to T1 and T3.

Effect of Aging at Low Temperature on Storage Stability of Seasoned Pork (저온 숙성이 양념돈육의 저장 안정성에 미치는 영향)

  • Hah Kyoung-Hee;Ahn Chong-Nam;Joo Seon-Tea;Park Gu-Boo;Park Ki-Hoon;Kim Il-Suk;Jin Sang-Keun
    • Food Science of Animal Resources
    • /
    • v.26 no.1
    • /
    • pp.85-91
    • /
    • 2006
  • This study was investigated the effect of aging at low temperature of seasoned pork with Korean traditional sauces. The samples, pork loins were cut by the shape of cube ($5{\times}15{\times}5\;cm$) and porks were seasoned with Korean tradition sauce such as soy sauce base (T1), red pepper sauce base (T2), and soybean sauce base (T3) in the same proportion of meat seasonings, respectively. The seasoned samples were stored, at $1{\pm}1^{\circ}C$ during 28 days. Surface meat color of seasoned pork was affected by the kind of sauces. Lightness of seasoned pork with soy sauce was decreased with increased in periods while red pepper sauce made it more red and soybean sauce produced a light seasoned pork, Lightness of inner meat color of seasoned pork was decreased with increased aging periods, and seasoned pork with soy sauce was lower compared to other treatments. TBARS of seasoned pork with soy sauce was lower compared to other treatments, and increased TBARS in all treatments with aging period. Total plate counts were increased with aging period, and those of seasoned pork with soy sauce were lower compared to other treatments. The microbial counts of Escherichia coli levels in all treatments was higher at the first day of aging periods. However Escherichia coli levels were decreased with increasing the aging period. Lactobacilli spp. of seasoned pork with soy sauce was not increased during aging periods, whereas other treatments were increased with aging period increased.

Quality Characteristics of Vacuum Packaged Fermented Pork with Soy Sauce, Red Pepper and Soybean Paste Seasoning during Storage (간장, 고추장 및 된장 양념으로 발효한 진공포장 돈육의 저장기간 동안 품질 특성)

  • Jin, S.K.;Kim, I.S.;Hah, K.H.;Lyou, H.J.;Park, K.H.;Lee, J.R.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.825-836
    • /
    • 2005
  • This study was carried out to evaluate the quality characteristics of the fermented pork with soy sauce, red pepper paste and soybean paste. The ham of pork were cut to cube (7 × 10 × 2 cm3) and Korea traditional seasonings such as soy sauce (T1), red pepper paste (T2), soybean paste (T3) were seasoned by the proportions of meat to seasonings (1:1), respectively. The pH of fermented pork with soybean paste seasoning were significantly higher compared to those for fermented pork with soy sauce and red pepper paste seasoning at 1 and 28 days of storage, but were significantly lower at 14 days of storage. The water-holding capacity of fermented pork with soy sauce seasoning were significantly higher compared to those for fermented pork with red pepper and soybean paste seasoning at 28 days of storage. The surface meat L* values of fermented pork with soybean paste seasoning were significantly higher compared to those for fermented pork with soy sauce and red pepper paste seasoning, but a* and b* values of fermented pork with red pepper paste seasoning significantly higher. The volatile basic nitrogen (VBN) of fermented pork with soybean paste seasoning were significantly lower compared to those for fermented pork with soy sauce seasoning at 1 and 28 days of storage. The shear force and thiobarbituric acid reactive substances (TBARS) of fermented pork with soybean paste seasoning were significantly lower compared to those for fermented pork with soy sauce and red pepper paste seasoning. The total plate counts of fermented pork with soybean paste seasoning were significantly higher compared to those for fermented pork with soy sauce and red pepper paste seasoning at 14 days of storage, but were significantly lower at 28 days of storage. The Escherichia coli of fermented pork with soy sauce and soybean paste seasoning were significantly lower compared to those for fermented pork with red pepper paste seasoning at 1 day of storage. The Lactobacilli spp. of fermented pork with red pepper paste seasoning were significantly lower compared to those for fermented pork with soy sauce and soybean paste seasoning.

Changes of Quality Characteristics of Seasoned Pork during Aging at 10℃ (양념 돈육의 10℃ 숙성시 품질변화)

  • Jin, S.K.;Kim, I.S.;Hah, K.H.;Lyou, H.J.;Park, K.H.;Lee, J.I.;Chung, K.Y.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.837-850
    • /
    • 2005
  • This study was conducted to investigate the changes of quality characteristics on seasoned pork with Korean traditional 4 types seasoning such as soybean sauce(T1); Kimchi sauce(T2); pickled shrimps sauce(T3); onion sauce(T4). The seasoned samples were aged at 10±1℃ for 13 days. The results obtained were as follows; Except for T2, pH of treatments were significantly decreased(P<0.05) as aging period increased. Salinity(%) and saccharinity(%) of seasoned meat were tended to increased during aging period. Thiobarbituric acid reactive substances(TBARS) were increased significantly during storage in all treatment(P<0.05). T4 showed the highest TBARS among the all treatment groups. Volatile basic nitrogen(VBN) values of all treatments were significantly increased(P<0.05) as storage period increased. There were no significant differences in water holding capacity(WHC) among the all treatments, and those values were not changed by the passage of storage days. Shear force values of all treatments were tended to decreased by the passage of storage days. In surface color, the values of L*, a* and b* showed a tendency of increasing value along the storage days. The values of a* and b* of T2 were significantly higher than other treatments during aging period(P<0.05). In inner color, a* and b* values of T2 were significantly higher than those of other treatments during aging period(P<0.05). In the sensory evaluation of cooked meat, T3 treatment resulted in lower score in aroma, flavor, tenderness, juiciness and overall acceptability. The number of total plate counts and Lactobacilli spp. tended to increase with storage in all treatments group. The numbers of Escherichia coli were not changed by the passage of storage time.

A CT Simulator Phantom for Geometrica1 Test (CT 시뮬레이터의 기하학적 성능평가용 팬톰)

  • Min, Chul-Kee;Yi, Byong-Yong;Ahn, Seung-Do;Choi, Eun-Kyung;Chang, Hye-Sook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.337-344
    • /
    • 2000
  • Purpose :To design and test test CT simulator phantom for geometrical test. Materials and Methods : The PMMA phantom was designed as a cylinder which is 20 cm in diameter and 24 cm in length, along with a 25$\times25\times31cm^{3}$ rectangular parallelepiped. Radio-opaque wires of which diameter is 0.8 mm are attached on the other surface of the phantom as a spiral. The rectangular phantom was made of four 24$\times24\times0.5 cm^{3}$ square plates and each plate had a 24$\times24 cm^{2}$, 12$\times12cm^{2}$, 6$\times6 cm$^{2}$ square line. The squares were placed to face the cylinder at angles 0 $^{\circ}$ , 15 $^{\circ}$ , 30 $^{\circ}$ ,respectively. The rectangular phantom made it possible to measure the field size, couch angle, the collimator angle, the isocenter shift and the SSD, the measurements of the gantry angle from the cylindrical part. A virtual simulation software, AcOSim, offered various conditions to perform virtual simulations and these results were used to perform the geometrical Quality assurance of CT simulator. Results : A 0.3$\~$0.5 mm difference was found on the 24 cm field size which was created with the DRR measurements obtained by scanning of the rectangular phantom. The isocenter shift, the collimator rotation, the couch rotation, and the gantry rotation test showed 0.5$\~$1 mm, 0.5$\~$l$^{\circ}$ 0.5$\~$ 1$^{\circ}$ , and 0.5-1 $^{\circ}$ differences, respectively. We could not find any significant differences between the results from the two scanning methods. Conclusion :The geometrical test phantom developed in the study showed less than 1 mm (or 1 $^{\circ}$ ) differences. The phantom could be used as a routine geometrical QC/QA tools, since the differences are within clinically acceptable ranges.

  • PDF

An Esthetic Restoration of the Missing Maxillary Anterior Teeth with the Rotational Path RPD: A Case Report (회전삽입로 국소의치를 이용한 심미적 상악 전치부 수복 증례)

  • Lee, Ji-Hye;Lim, So-Min;Jung, Hye-Eun;Park, Chan-Jin;Cho, Lee-Ra;Kim, Dae-Gon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.209-222
    • /
    • 2011
  • Missing anterior teeth can be replaced using any of a number of methods. Patients may choose to replace missing teeth with a prosthesis that is either removable, fixed, or retained with implants. For patients faced with financial, anatomical, and/or esthetic limitations, the edentulous region can be restored successfully and esthetically with a properly designed and fabricated rotational path RPD. The rotational path RPD is a partial removable dental prosthesis that incorporates a curved, arcuate, or variable path of placement allowing one or more of the rigid components of the framework to gain access to and engage an undercut area. The rigid retainer must gain access to the infrabulge portion of the tooth by rotating into place. Either a minor connector or proximal plate provides retention through its intimate contact with a proximal tooth surface. A specially designed dovetails or asymmetric rest seats provides support and embracing effects. Correctly designed and fabricated rotational path RPD can provide improved esthetics, cleanliness, and retention. But rotational path RPDs are technique sensitive since the rotational path RPD has little margin of laboratory error that rigid retainers cannot be adjusted like conventional clasps can, RPD framework must be remade once the retention is lost. The sufficient understanding of the concept for the rotational path RPD is required for clinically successful treatment. This clinical report describes in detail the theoretical, laboratory considerations and the treatment of a patient with an anterior maxillary edentulous area treated by an AP path rotational RPD that had a difficulty in long term maintenance and describes another clinical case in which more reasonable treatment procedures were approached after analyzing the former case.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2011 (설비공학 분야의 최근 연구 동향: 2011년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Paik, Yong-Kyoo;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.521-537
    • /
    • 2012
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2011. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of fluid machinery and fluid flow, thermodynamic cycle, and new and renewable energy. Various topics were presented in the field of fluid machinery and fluid flow. Research issues mainly focused on the rankine cycle in the field of thermodynamic cycle. In the new and renewable energy area, researches were presented on geothermal energy, fuel cell, biogas, reformer, solar water heating system, and metane hydration. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, nanofluids and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer above liquid helium surface in a cryostat, methane hydrate formation, heat and mass transfer in a liquid desiccant dehumidifier, thermoelectric air-cooling system, heat transfer in multiple slot impinging jet, and heat transfer enhancement by protrusion-in-dimples. In the area of pool boiling and condensing heat transfer, researches on pool boiling of water in low-fin and turbo-B surfaces, pool boiling of R245a, convective boiling two-phase flow in trapezoidal microchannels, condensing of FC-72 on pin-finned surfaces, and natural circulation vertical evaporator were actively performed. In the area of nanofluids, thermal characteristics of heat pipes using water-based MWCNT nanofluids and the thermal conductivity and viscosity were measured. In the area of industrial heat exchangers, researches on fin-tube heat exchangers for waste gas heat recovery and Chevron type plate heat exchanger were implemented. (3) Refrigeration systems with alternative refrigerants such as $CO_2$, hydrocarbons, and mixed refrigerants were studied. Heating performance improvement of heat pump systems were tried applying supplementary components such as a refrigerant heater or a solar collector. The effects of frost growth were studied on the operation characteristic of refrigeration systems and the energy performance of various defrost methods were evaluated. The current situation of the domestic cold storage facilities was analyzed and the future demand was predicted. (4) In building mechanical system fields, a variety of studies were conducted to achieve effective consumption of heat and maximize efficiency of heat in buildings. Various researches were performed to maximize performance of mechanical devices and optimize the operation of HVAC systems. (5) In the fields of architectural environment and energy, diverse purposes of studies were conducted such as indoor environment, building energy, and renewable energy. In particular, renewable energy and building energy-related researches have mainly been studied as reflecting the global interests. In addition, various researches have been performed for reducing cooling load in a building using spot exhaust air, natural ventilation and energy efficiency systems.

Comparison of Experimental and Radiation Therapy Planning (RTP) Dose Distributions on Air Cavity (공동(air cavity)의 존재 시 실험적 선량분포와 치료계획상의 선량분포 비교)

  • Kim, Yon-Lae;Suh, Tae-Suk;Ko, Shin-Gwan;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.261-268
    • /
    • 2010
  • This study is compared that the dose distribution by experimentation and radiation therapy planning (RTP) when the air cavity region was treated high energy photon. The dose measurements were performed with a 6 MV photon beam of linear accelerator. The polystyrene and self made acyl phantom were similar to tissue density of the human body. A parallel plate chamber was connected to an electrometer. The measurement setup was SCD (Source Chamber Distance) 100 cm and the distance of surface from air cavity was 3 cm. Absorbed dose of interface were measured by area and height. The percent depth dose were measured presence and absence of air cavity, depth according to a ratio of field size and air cavity size. The dose distribution on planning was expressed to do the inhomogeneity correction. As the area of air cavity was increased, the absorbed dose were gradually reduced. It was slightly increased, when the height of air cavity was changed from 0 cm to 0.5 cm. After the point, dose was decreased. In case of presence of air cavity, dose after distal air cavity interface was more great than absence of air cavity. The rebuild up by field size and area of air cavity occurred for field size, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$ and $6{\times}6\;cm^2$, with fixed on area of air cavity, $5{\times}5\;cm^2$. But it didn't occur at $10{\times}10\;cm^2$ field size. On the contrary, the field size was fixed on $5{\times}5\;cm^2$, rebuild up occurred in area of air cavity, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$. but, it did not occur for air cavity, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$. All of the radiation therapy planning were not occurred rebuild up. It was required to pay attention to treat tumor in air cavity because the dose distribution of planning was different from the dose distribution of patient.

A Study on the Characteristic and Manufacture Technique for the Gold wire of Phoenix-Shaped Glass Ewer by National Treasure No. 193 (국보 제193호 봉수형유리병 금사의 특성과 제작기법 연구)

  • Hwang, Hyun Sung;Yun, Eun Young
    • Journal of Conservation Science
    • /
    • v.31 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • The Phoenix-shaped Glass Ewer, which is No. 193 National Treasure, was seriously damaged by a unique form of green glass pieces when excavated among a number of burial accessories of Hwangnamdaechong known to have been formed in the 5th century. While it has long been exhibited at the National Museum of Korea since its treatment for conservation treatment at conservation science laboratory in 1984, the existing adhesive materials seriously deteriorated for the 30 years, and the condition was quite unstable. The epoxy resin used as a restorative materials turned yellowing due to the light and heat so much that it was no longer able to exhibit it in a stable and effective manner. As a result, a re-treatment for conservation was conducted lately. This study focuses on the three pieces of Gold wires used to carefully wrap up the handle of the Phoenix-shaped Glass Ewer broken into three pieces, which has not been studied so far. As for the analysis method for Gold wires, SEM-EDS and Stereo Microscope were used for nondestructive analysis. First of all, the result of the SEM-EDS analysis shows that the composition was Au 91.9 wt.%-Au 92.8 w.t% and Ag 5.9 wt.%-Ag 6.5 wt.%, which indicates that it was an alloy made of Au and Ag. The production technique of Gold wires was also observed by means of optical microscopes. In general, Gold wires were manufactured by a drawing process in which a lump of gold was beaten or pulled out of a hole or by a process of twisting a gold plate. However, Gold wires separated from the handle of the Phoenix-shaped Glass Ewer did not involve any trace of twisting on the surface. Rather, fine vertical stripes were observed with the sections filled up. Hence, it is thought that this Ewer went through a drawing process and then was mended. As a result, no certain relation with the golden mending material used for the Phoenix-shaped Glass Ewer was verified. The findings above indicate that most of the existing researches on Gold wires recognized them, not as separate remains, but merely as a component of other golden remains. Thus, there has been little systematic study on the manufacturing techniques of Gold wires. The future study on Gold wires may verify the correlation between the Gold wires used to fix the handle of the Phoenix-shaped Glass Ewer, which is examined in this study, with that of golden remains in the Silla era.

A Study on the Verification of an Indoor Test of a Portable Penetration Meter Using the Cone Penetration Test Method (자유낙하 콘관입시험법을 활용한 휴대용 다짐도 측정기의 실내시험을 통한 검증 연구)

  • Park, Geoun Hyun;Yang, An Seung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.2
    • /
    • pp.41-48
    • /
    • 2019
  • Soil compaction is one of the most important activities in the area of civil works, including road construction, airport construction, port construction and backfilling construction of structures. Soil compaction, particularly in road construction, can be categorized into subgrade compaction and roadbed compaction, and is significant work that when done poorly can serve as a factor causing poor construction due to a lack of compaction. Currently, there are many different types of compaction tests, and the plate bearing test and the unit weight of soil test based on the sand cone method are commonly used to measure the degree of compaction, but many other methods are under development as it is difficult to secure economic efficiency. For the purpose of this research, a portable penetration meter called the Free-Fall Penetration Test (FFPT) was developed and manufactured. In this study, a homogeneous sample was obtained from the construction site and soil was classified through a sieve analysis test in order to perform grain size analysis and a specific gravity test for an indoor test. The principle of FFPT is that the penetration needle installed at the tip of an object put into free fall using gravity is used to measure the depth of penetration into the road surface after subgrade or roadbed compaction has been completed; the degree of compaction is obtained through the unit weight of soil test according to the sand cone method and the relationship between the degree of compaction and the depth of the penetration needle is verified. The maximum allowable grain size of soil is 2.36 mm. For $A_1$ compaction, a trend line was developed using the result of the test performed from a drop height of 10 cm, and coefficient of determination of the trend line was $R^2=0.8677$, while for $D_2$ compaction, coefficient of determination of the trend line was $R^2=0.9815$ when testing at a drop height of 20 cm. Free fall test was carried out with the drop height adjusted from 10 cm to 50 cm at increments of 10 cm. This study intends to compare and analyze the correlation between the degree of compaction obtained from the unit weight of soil test based on the sand cone method and the depth of penetration of the penetration needle obtained from the FFPT meter. As such, it is expected that a portable penetration tester will make it easy to test the degree of compaction at many construction sites, and will lead to a reduction in time, equipment, and manpower which are the disadvantages of the current degree of compaction test, ultimately contributing to accurate and simple measurements of the degree of compaction as well as greater economic feasibility.