• 제목/요약/키워드: Surface plasmon resonance sensor

검색결과 79건 처리시간 0.026초

광섬유 표면 플라즈몬 공명 센서를 이용한 스트레인 및 온도 측정 (Measurement of temperature and strain using fiber-optic surface plasmon resonance sensor)

  • 정재훈;김민욱
    • 전기전자학회논문지
    • /
    • 제11권2호
    • /
    • pp.77-82
    • /
    • 2007
  • 본 논문에서는 광섬유 표면 플라즈몬 공명 센서를 이용하여 스트레인 및 온도 변화에 따른 센서를 제시하였다. 광섬유 센서의 구조는 광섬유의 클래딩 일부를 제거하여 크롬, 은, 금을 증착한 다층 박막 구조를 모델로 하였고, dip 파장의 변화가 선형성을 보임으로써 효율적인 센서로의 활용 가능성을 보이고자 한다.

  • PDF

Evaluation of Two Types of Biosensors for Immunoassay of Botulinum Toxin

  • Choi, Ki-Bong;Seo, Won-Jun;Cha, Seung-Hee;Choi, Jung-Do
    • BMB Reports
    • /
    • 제31권1호
    • /
    • pp.101-105
    • /
    • 1998
  • Immunoassay of botulinum toxin (BTX) B type was investigated using two typed of biosensors: light addressable potentiometric sensor (LAPS) and surface plasmon resonance (SPR) sensor. Urease-tagged and immuno-filtration capture method have been used for LAPS. Tag-free and direct binding real-time detection method have been used for SPR sensor. The detection limit of sandwich assay format with LAPS was 10 ng/ml, which was the lowest among methods tested. SPR has the advantage of being more convenient because tag-free direct binding assay can be used and reaction time was reduced, regardless of low sensitivity. This result shows that sandwich assay format with LAPS can be used as an alternative method of BTX mouse bioassay which is known as the most sensitive method for the detection of BTX.

  • PDF

Immunoaffinity Characteristics of Exosomes from Breast Cancer Cells Using Surface Plasmon Resonance Spectroscopy

  • Sohn, Young-Soo;Na, Wonhwi;Jang, Dae-Ho
    • 센서학회지
    • /
    • 제28권6호
    • /
    • pp.355-359
    • /
    • 2019
  • Exosomes, known as nanoscale extracellular vesicles in the range of 30-150 nm, are known to contain clinically significant information. However, there is still insufficient information on exosomal membrane proteins for cancer diagnosis. In this work, we investigated the characteristics of the membrane proteins of exosomes shed by cultured breast cancer cell lines using a surface plasmon resonance (SPR) spectroscopy and pre-activated alkanethiols modified sensor chips. The antibodies of breast cancer biomarkers such as MCU-16, EpCAM, CD24, ErbB2, and CA19-9 were immobilized on the pre-activated alkanethiols surfaces without any activation steps. The purified exosomes were loaded onto each antibody surface. The affinity rank of the antibody surfaces was decided by the relative capture efficiency factors for the exosomes. In addition, an antibody with a relative capture efficiency close to 100% was tested with exosome concentration levels of 104/µl, 105/µl, and 106/µl for quantitative analysis.

표면플라즈몬공명 바이오센서를 이용한 살모넬라 검출 (Detection of Pathogenic Salmonella Using a Surface Plasmon Resonance Biosensor)

  • 조한근;김기영;김운호;성민선
    • Journal of Biosystems Engineering
    • /
    • 제35권2호
    • /
    • pp.116-123
    • /
    • 2010
  • Rapid detection of foodborne pathogens has been a major challenge for the food industry. Salmonella contamination is well known in all foods including pasteurised milk. The possibility of specific detection of Salmonella Enteritidis by surface plasmon resonance (SPR) biosensor was explored using a commercially available portable SPR sensor. Self assembly technique was adopted to immobilize anti-Salmonella antibodies on the gold sensing surface of the SPR sensor. The concentration of polyclonal antibody for use in the SPR biosensor was chosen to 1.0 mg/mL. Experiments were conducted at near real-time with results obtained for one SPR biosensor assay within 1 hour. The limit of detection for Salmonella Enteritidis was determined to be $10^6$ CFU/mL in both PBS buffer and milk samples. The assay sensitivity was not significantly affected by milk matrix. Our results showed that it would be possible for employing the SPR biosensor to detect Salmonella Enteritidis in near real-time.

SK 지수를 이용한 표면 플라즈몬 공명 바이오 센서의 측정방법의 분류 (Classification of Measurement Methods of Surface Plasmon Resonance Biosensors by SK Index)

  • 이승기
    • 센서학회지
    • /
    • 제13권5호
    • /
    • pp.342-349
    • /
    • 2004
  • SK (SPR Kinds) index, which can categorize the complicated measurement methods of surface plasmon resonance by simple method, has been proposed and verified. SK index is composed of three digits, where each digit presents the type of immobilized ligand, the type of illumination and the kinds of varying parameter, sequentially. The measurement method of (33#) series among SK indices shows the possibility of the multi-sensing capability, by which the response of 2-dimensional array of immobilized ligands can be detected simultaneously. The proposed possibility of multi-sensing capability has been verified by the modeling that is based on Fresnel reflection model.

표면 플라즈몬 공명 센서에서의 쌍금속 은-금 박막 구조의 광학 특성 (Optical Characteristics of Bimetallic Silver-Gold Film Structure in Surface Plasmon Resonance Sensor Applications)

  • 권혁록;이성혁
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.156-160
    • /
    • 2007
  • Surface plasmon resonance(SPR) has been widely studied for biological and chemical sensing applications. The present study conducts numerical simulation for the single and bimetallic layer SPR configurations by using the multiple beam interference matrix(MBIM) method to investigate the influence of wave interference and complex refractive indices of materials on optical characteristics such as reflectance and optical phase shift which are used for sensing. First, calculated reflectances are compared with experimental data for validation. In addition, in the single film structures this study finds out the appropriate film thicknesses with minimum reflectance for cases of gold film and silver film. For a bimetallic silver-gold film structure, in particular, the bimetallic film thicknesses that has the minimum reflectance are found 36 nm for silver and 5 nm for gold. From the results, the use of phase shift would be useful compared to reflectance in determining the SPR configuration because the phase shift becomes more sensitive than reflectance.

Optimal Design of Fiber-optic Surface Plasmon Resonance Sensors

  • Jung, Jae-Hoon;Kim, Min-Wook
    • Journal of the Optical Society of Korea
    • /
    • 제11권2호
    • /
    • pp.55-58
    • /
    • 2007
  • We propose a systematic method for design of fiber-optic surface plasmon resonance (SPR) sensors. We used rigorous coupled wave analysis (RCWA) for analysis of the transmission spectrum, and the (1+1) evolution strategy (ES) was employed as an optimization tool. The simulation results show that the optimization method presented here is very useful in designing fiber-optic SPR sensor for strain and temperature measurement. This algorithm can be extended to another objective function with other weighting factors and optical parameters.

Graphene Coated Optical Fiber SPR Biosensor

  • Kim, Jang Ah;Hwang, Taehyun;Dugasani, Sreekantha Reddy;Kulkarni, Atul;Park, Sung Ha;Kim, Taesung
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.401-401
    • /
    • 2014
  • In this study, graphene, the most attractive material today, has been applied to the wavelength-modulated surface plasmon resonance (SPR) sensor. The optical fiber sensor technology is the most fascinating topic because of its several benefits. In addition to this, the SPR phenomenon enables the detection of biomaterials to be label-free, highly sensitive, and accurate. Therefore, the optical fiber SPR sensor has powerful advantages to detect biomaterials. Meanwhile, Graphene shows superior mechanical, electrical, and optical characteristics, so that it has tremendous potential to be applied to any applications. Especially, grapheme has tighter confinement plasmon and relatively long propagation distances, so that it can enhance the light-matter interactions (F. H. L. Koppens, et al., Nano Lett., 2011). Accordingly, we coated graphene on the optical fiber probe which we fabricated to compose the wavelength-modulated SPR sensor (Figure 1.). The graphene film was synthesized via thermal chemical vapor deposition (CVD) process. Synthesized graphene was transferred on the core exposed region of fiber optic by lift-off method. Detected analytes were biotinylated double cross-over DNA structure (DXB) and Streptavidin (SA) as the ligand-receptor binding model. The preliminary results showed the SPR signal shifts for the DXB and SA binding rather than the concentration change.

  • PDF

공명각 및 반사광 측정 모드에서 다양한 물질 구성의 표면 플라즈몬 공명 센서 칩의 민감도 특성 (A Study on the Sensitivity of Surface Plasmon Resonance Sensor Chips with Various Material Configurations in Angle and Intensity Detection Modes)

  • 손영수
    • 센서학회지
    • /
    • 제26권6호
    • /
    • pp.402-407
    • /
    • 2017
  • Characteristics of various material surface plasmon resonance (SPR) chips were investigated in angular interrogation mode and intensity interrogation mode. Among five metals, silver (Ag), gold (Au), copper (Cu), chromium (Cr) and titanium (Ti), three metals, Ag, Au and Cu were paid attention to since their characteristics can be easily analyzed in angular interrogation mode by investigating the change of their reflectance curves according to refractive index change from 1.331 to 1.335. Most of SPR chips with various configurations showed the similar property in angular interrogation mode. The application of the SPR chip made of Ag, Au and Cu or their combinations depends on their reflectance properties. In intensity interrogation mode, the operation range may be limited since the variation of the intensity was not linearly related to refractive index change ranging from 1.331 to 1.335. However, the SPR chip containing high ratio of Ag may be applicable to high sensitive detection due to their sharp reflectance curves in intensity interrogation mode.

소형 표면 플라즈몬 공명 센서와 이합체 구조를 가진 SAM을 이용한 CRP 검출 (A portable surface plasmon resonance sensor system for detection of C-reactive protein using SAM with dimer structure)

  • 신은정;정은정;조진희;황동환;손영수
    • 센서학회지
    • /
    • 제19권6호
    • /
    • pp.456-461
    • /
    • 2010
  • The detection of C-reactive protein(CRP) using self-assembled monolayer(SAM) was investigated by a portable surface plasmon resonance(SPR) sensor system. The CRP is a biomarker for the possible cardiovascular disease. The SAM was formed on gold(Au) surface to anchor the monoclonal antibody of CRP(anti-CRP) for detection of CRP. Sequence injection of the anti-CRP and bovine serum albumin(BSA) into the sensor system has been carried out immobilize the antibody and to prevent non-specific binding. The portable SPR system has two flow channels: one for the sample measurements and the other for the reference. The output SPR signal was increased with the injection of the anti-CRP, BSA and CRP due to binding of the proteins on the sensor chip. The valid output SPR signals was linearly related to the critical range of the CRP concentration. The experimental results showed the feasibility of the portable SPR system with newly developed SAM to diagnose a risk of the future cardiovascular events.