References
- H. Chen, J. Huang, J. Lee, S. Hwang, and K. Koh, “Surface plasmon resonance spectroscopic characterizatin of antibody orientation and activity on the calixarene monolayer”, Sens. Actuators B, vol. 147, pp. 548-553, 2010. https://doi.org/10.1016/j.snb.2010.03.033
- P. J. Conroy, S. Hearty, P. Leonard, and R. J. O’Kennedy, “Antibody production, design and use for biosensor-based applications”, Semin. Cell Dev. Biol., vol. 20, pp. 10-26, 2009. https://doi.org/10.1016/j.semcdb.2009.01.010
- R. M. Lequin, “Enzyme Immunoassay(EIA) / Enzyme-Linked Immunosorbent Assay”, Clin. Chem., vol. 51, pp. 2415-2418, 2005. https://doi.org/10.1373/clinchem.2005.051532
- R. Hao, D. Wang, X. Zhang, G. Zuo, H. Wei, R. Yang, Z. Zhang, Z. Cheng, Y. Guo, Z. Cui, and Y. Zhou, “Rapid detection of Bacillus anthracis using monoclonal antibody functionalized QCM sensor”, Biosens. Bioelectron, vol. 24, pp. 1330-1335, 2009. https://doi.org/10.1016/j.bios.2008.07.071
- H. Xu, X. Zhao, C. Grant, J. R. Lu, D. E. Williams, and J. Penfold, “Orientation of a monoclonal antibody adsorbed at the solid/solution interface: a combined study using atomic force microscopy and neutron reflectivity”, Langmuir, vol. 22, pp. 6313-6320, 2006. https://doi.org/10.1021/la0532454
- M. Salmain, N. Fischer-Durand, and C.-M. Pradier, "Infrared optical immunosensor: Application to the measurement of the herbicide atrazine”, Anal. Biochem. vol. 373, pp. 61-70, 2008. https://doi.org/10.1016/j.ab.2007.10.031
- Y.-S. Sohn, C.-K. Kim, and S.-Y. Choi, “Characteristics of a label-less electrochemical immunosensor based on a field-effect transistor for the detection of a biomarker in urine”, Sens. Lett. vol. 7, pp. 640-643, 2009. https://doi.org/10.1166/sl.2009.1119
- 윤성식, 이수형, 안종혁, 이종현, “Cycilic olefin copolymer(COC) 폴리머 프리즘을 사용한 광섬유 기반 표면 플라즈몬 공명(SPR) 바이오 센서”, 센서학회지, 제17권, 제5호, pp. 369-374, 2008.
- R. B. M. Schasfoort and A. J. Tudos, Handbook of surface plasmon resonance, Royal Society of Chemistry, London, 2008.
- 이훈, 이승기, “광섬유 국소화 표면 플라즈몬 공명 센서를 위한 광섬유 표면상의 금속 나노 입자 형성”, 센서학회지, 제17권, 제2호, pp. 95-99, 2008. https://doi.org/10.5369/JSST.2008.17.2.095
- S. K. Arya, P. R. Solanki, M. Datta, and B. D. Malhotra, “Recent advances in self-assembled monolayers based biomolecular electronic devices”, Biosens. Bioelectron, vol. 24, pp. 2810-2817, 2009. https://doi.org/10.1016/j.bios.2009.02.008
- K.-Y. Park, Y.-S. Sohn, C.-K. Kim, H.-S. Kim, Y.-S. Bae, and S.-Y. Choi, “Development of FET-type albumin sensor for diagnosing nephritis”, Biosens. Bioelectron, vol. 23, pp. 1904-1907, 2008. https://doi.org/10.1016/j.bios.2008.03.011
- M. Hamer, Y. Chida, and E. Stamataki, “Utility of C-reactive protein for cardiovascular risk stratification across three age groups in subjects without existing cardiovascular diseases”, Am. J. Cardiol., vol. 104, pp. 538-542, 2009. https://doi.org/10.1016/j.amjcard.2009.04.020
- H. Y. Tsai, C. F. Hsu, I. W. Chiu, and C. B. Fuh, “Detection of C-reactive protein based on immunoassay using antibody-conjugated magnetic nano-particles”, Anal. Chem., vol. 79, pp. 8416-8419, 2007. https://doi.org/10.1021/ac071262n
- H.-M. Cho, D.-H. Jang, S.-K. Lee, S.-J. Ku, H.-C. Kim, K.-S. Yu, and J.-W. Lee, “Characterization of novel self assembled materials(SAM) for surface modification of sensor chip”, Biochip J., vol. 2, pp. 206-211, 2008.