• Title/Summary/Keyword: Surface passivation

Search Result 359, Processing Time 0.03 seconds

An Electrochemical Evaluation on the Crevice Corrosion of 430 Stainless Steel with Variation of Crevice Wide by Micro Capillary Tubing Method (Micro Capillary Tube 방법을 이용한 430 스테인레스강 틈의 폭변화에 따른 틈부식의 전기화학적 평가)

  • Na, Eun-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.4
    • /
    • pp.250-254
    • /
    • 2003
  • In this study, the IR drop theory was adopted to explain the initiation of crevice corrosion in the framework of IR drop in crevice electrolyte. Furthermore, the electrochemical polarization was measured to study the mechanism of crevice corrosion for type STS430 stainless steel. lest method adopts under condition that the size of specimen is $10\times20\times5mm,\;in\;1N\;H_2SO_4+0.1N\;NaCl$ solution, and the artificial crevice gap sizes are three kinds, the Micro capillary tube size is inner diameter 0.04 mm, outer diameter 0.08 mm. Crevice corrosion is measured under the applied voltage of passivation potential -200mV/SCE, resulted from anodic potentio-dynamic polarization to the external surface along the crevice. The potential difference was measured by depth profile by Micro capillary tube which inserted in the crevice. The obtained results of this study showed that 1) As artificial crevice gap size became narrow, the current density was increased, whereas no crevice corrosion was found in the crevice gap size $3\times0.5\times16mm\;in\;1N\;H_2SO_4+0.1N\;NaCl\;solution\;at\;20^{\circ}C$ 2) potential of the crevice was about from -220 to -358mV which is lower than that of external surface potential of -200mV The results so far confirmes that the potential drop(so-called IR drop) in the crevice is one of the major mechanisms the process of crevice corrosion for 430 stainless steel.

Chemical Effects on Head Loss across Containment Sump Strainer under Post-LOCA Environment (LOCA이후 환경에서 원자로건물집수조 여과기의 수두손실에 대한 화학적 영향)

  • Ku, Hee-Kwon;Jung, Bum-Young;Hong, Kwang;Jeong, Eun-Sun;Jung, Hyun-Jun;Park, Byung-Gi;Rhee, In-Hyoung;Park, Jong-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3260-3268
    • /
    • 2009
  • A test apparatus has been fabricated to simulate chemical effect on head loss through a strainer in a pressurized water reactor (PWR) containment water pool after a loss of coolant accident (LOCA). Tests were conducted under condition of same ratio of strainer surface area to water volume between the test appratus and the containment sump. A series of tests have been performed to investigate the effects of spray, existence of calcium-silicate with tri-sodium phosphate (TSP), and composition of materials. The results showed that head loss across the chemical bed with even a small amount of calcium-silicate insulation instantaneously increased as soon as TSP was added to the test solution. Also, the head loss across the test screen is strongly affected by spray duration and is increased rapidly at the early stage, because of high dissolution and precipitation of aluminum and zinc. After passivation of aluminum and zinc by corrosion, the head loss increase is much slowed down and is mainly induced by materials such as calcium, silicon, and magnesium leached from NUKONTM and concrete. Furthermore, it is newly found that the spay buffer agent, tri-sodium phosphate, to form protective coating on the aluminum surface and reduce aluminum leaching is not effective for a large amount of aluminum and a long spray.

AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS (수종 임플랜트 금속의 내식성에 관한 전기화학적 연구)

  • Jeon Jin-Young;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF

Electronic Structure and Elemental Composition of the Lead Sulfide Colloidal Quantum Dots Depending on the Types of Ligand and Post-Treatment (리간드 종류와 후처리 공정에 따른 황화납 콜로이드 양자점 박막의 전자 구조 및 원소 조성 분석)

  • Kim, Tae Gun;Choi, Hyekyoung;Jeong, Sohee;Kim, Jeong Won
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.6
    • /
    • pp.402-409
    • /
    • 2016
  • Thin films of lead sulfide colloidal quantum dots (CQDs) of 2.8 nm in diameter are fabricated and their surfaces are passivated by 3-mercaptopropionic acid (MPA) ligand or hybrid type ($MPA+CdCl_2$) ligand, respectively. The changes in valence band electronic structure and atomic composition of each PbS CQD film upon post-treatment such as air, N2 annealing or UV/Ozone have been studied by photoelectron spectroscopy. The air annealing makes the CQD fermi level to move toward the valence band leading to "p-type doping" regardless of ligand type. The UV/Ozone post-treatment generates $Pb(OH)_2$, $PbSO_x$ and PbO on both CQD surfaces. But the amount of the PbO has been reduced in hybrid type ligand case, especially. That is probably because the extra Pb cations in (111) surface are additionally passivated by $Cl_2$ ligand, which limits the reaction between the Pb cation and ozone.

High-performance WSe2 field-effect transistors fabricated by hot pick-up transfer technique (핫픽업 전사기술을 이용한 고성능 WSe2 기반 전계효과 트랜지스터의 제작)

  • Kim, Hyun Ho
    • Journal of Adhesion and Interface
    • /
    • v.21 no.3
    • /
    • pp.107-112
    • /
    • 2020
  • Recently, the atomically thin transition-metal dichalcogenide (TMD) semiconductors have attracted much attention owing to their remarkable properties such as tunable bandgap with high carrier mobility, flexibility, transparency, etc. However, because these TMD materials have a significant drawback that they are easily degraded in an ambient environment, various attempts have been made to improve chemical stability. In this research article, I report a method to improve the air stability of WSe2 one of the TMD materials via surface passivation with an h-BN insulator, and its application to field-effect transistors (FETs). With a modified hot pick-up transfer technique, a vertical heterostructure of h-BN/WSe2 was successfully made, and then the structure was used to fabricate the top-gate bottom-contact FETs. The fabricated WSe2-based FET exhibited not only excellent air stability, but also high hole mobility of 150 ㎠/Vs at room temperature, on/off current ratios up to 3×106, and 192 mV/decade of subthreshold swing.

Inhibition of Plaque Formation on the Titanium Surface by Anti-bacterial Varnish (항균제 처리한 titanium 표면의 치태형성 억제효과)

  • Chung, Hyun-Ju;Lee, Sang-Hyun;Kim, Yung-Jun;Williams, Ray C.
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.4
    • /
    • pp.707-727
    • /
    • 2000
  • 매식된 인공치아의 성공을 위해서는 적절한 교합과 수동적 적합성을 갖는 보철물의 제작과 구강내 노출 직후부터의 세균성 치태조절이 요구된다. 본 연구는 전처리(passivation과 tridodecyl - methyl - ammonium chloride(TDMAC) 처리)가 다른 타이타늄 표 면에 chlorhexidine varnish와 테트라사이클린 을 도포시 약제의 방출역학을 알아보고 구강내 치태형성의 억제정도를 평가하기 위하여 시행 되었다. 이를 위해 방출용액으로 인산완충액 성분의 인조타액을 1일${\sim}$1개월간 매일 교환하여 약제농도를 측정하고 타이타늄 박막에 잔류한 약제 활성을 측정하였으며 항균제 도포한 타이타늄 원판을 부착한 장치를 구강내 위치시킨 1일${\sim}$3주 후 원판을 제거하여 주사전자현미경으로 세균 부착상을 관찰하였다. 테트라사이클린은 TDMAC 처리된 표면에서 $10{\sim}18$일까지 유효농도로 방출되었고 표면의 유효 항균 활성은 $3{\sim}4$주간 유지되었으며, chlorhexidine varnish 도포 시에는 TDMAC 전처리시 초기에 $3{\sim}7$일 간 증가한 유효 항균 활성을 방출하여 매식지대치 등에 이러한 항균제도포 시 매식치 주위환경에 항균활성 공급원으로 작용할 수 있음을 보였다. 주사현미경적 관찰시 모든 타이타늄 표면에서 구강내 위치 30분 후에는 세균이 부착되어 있지 않고 타액 단백질 성분에서 유래한 것으로 보이는 피막물질이 표면을 부분 또는 전면에 걸쳐 덮고 있었다. 구강내 노출 2시간 후 항균제 미도포 표본들에는 약간의 구균이 단층으로, $1{\sim}3$일 후에는 부분적으로 두꺼운 세균층을 형성하였고 7일 후에는 표면전체에 걸쳐 세균층이 덮여있었으며 주로 구균과 약간의 간균이 주종을 이루었다. 항균제 도포시 구강내 노출 1주일 이전까지는 미도포군에 비해 치태형성이 지연되는 경향을 보였지만 2주 이후에는 세균 수나 치태형성 양상이 유사하였다. 이 연구로부터 항균제 도포시 1주일 이전의 초기 치태형성을 감소시킬 수 있음을 알 수 있었으며 이러한 연구결과는 타이타늄 임프란트 지대치 표면에 항균제의 도포가 임상적으로 유용할 수 있음을 시사하였다.

  • PDF

The Silicon Nitride Films according to The Frequency Conditions of Plasma Enhanced Chemical Vapor Deposition (PECVD의 주파수 조건에 따른 $SiN_x$막 증착)

  • Choi, Jeong-Ho;Roh, Si-Cheol;Jung, Jong-Dae;Seo, Hwa-Il
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.4
    • /
    • pp.21-25
    • /
    • 2014
  • The silicon nitride ($SiN_x$) film for surface passivation and anti-reflection coating of crystalline silicon solar cell is very important and it is generally deposited by plasma enhanced chemical vapor deposition (PECVD). PECVD can be divided into low and high frequency method. In this paper, the $SiN_x$ film deposited by low and high frequency PECVD method was studied. First, to optimize the $SiN_x$ film deposited by low frequency PECVD method, the refractive index was measured by varying the process conditions like $SiH_4$, $NH_3$, $N_2$ gas rate, and RF power. When $SiH_4$ gas rate was increased and $NH_3$ gas rate was decreased, the refractive index was increased. The refractive index was also increased with RF power decline. Second, to compare the characteristics of the low and high frequency PECVD $SiN_x$ film, the refractive index was measured by varying $NH_3/SiH_4$ gas ratio and RF power and the minority carrier lifetime of before and after high temperature treatment process was also measured. The refractive index of both low and high frequency PECVD $SiN_x$ film was decreased with increase in $NH_3/SiH_4$ gas ratio and RF power. After high temperature treatment process, the minority carrier lifetime of both low and high frequency PECVD $SiN_x$ film was increased and increased degree was similar. The minority carrier lifetime of low frequency PECVD $SiN_x$ was increased from $11.03{\mu}m$ to $28.24{\mu}m$ and that of high frequency PECVD $SiN_x$ was increased from $11.60{\mu}m$ to $27.10{\mu}m$.

Performance assessment of Magnesium Bipolar Plates for Light Weight PEM Fuel Cell (PEM 연료전지 경량화를 위한 마그네슘 분리판의 성능평가)

  • Park, To-Soon;Lee, Dong-Woo;Kim, Kyung-Hwan;Kwon, Se-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.12
    • /
    • pp.1063-1069
    • /
    • 2012
  • In present paper, we used magnesium alloy having a lower density and higher electrical conductivity for bipolar plate to reduce the weight of PEM fuel cell. The silver was coated to prevent corrosion and form passivation film on the metal surface with sputtering. In acid proof evaluation for setting optimal coating conditions, the homogeneity of coating thickness was improved by coating with the thickness of 3 ${\mu}m$ which not indicated any micro cracks and the temperature $180^{\circ}C$. The performance test and evaluation based on the clamping pressure and channel depth to determine the configuration of bipolar plate for assembling single cell was implemented. And then we assembled single cell with this bipolar plate and implemented the performance test to ensure and compare the current-voltage performance followed as several factors such as coating or non-coating, the change of clamping pressure, the change of channel depth, etc. As these results, the maximum power density of single cell with the coated bipolar plate was 192 $mW/cm^2$ and it was confirmed that the power density per unit mass was better than existing metal bipolar plate.

Effect of SUS316L Bipolar Plate Corrosion on Contact Resistance and PEMFC Performance (SUS316L 분리판 부식에 의한 접촉저항 및 고분자전해질 연료전지 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.664-670
    • /
    • 2021
  • Stainless steel was applied as bipolar plate (BP) of polymer electrolyte membrane fuel cell (PEMFC) due to high mechanical strength, electrical conductivity, and good machinability. However, stainless steel was corroded and increased contact resistance resulting PEMFC performance decrease. Although the corrosion resistance could be improved by surface treatment such as noble metal coating, there is a disadvantage of cost increase. The stainless steel corrosion behavior and passive layer influence on PEMFC performance should be studied to improve durability and economics of metal bipolar plate. In this study, SUS316L bipolar plate of 25 cm2 active area was manufactured, and experiments were conducted for corrosion behavior at an anode and cathode. The influence of SUS316L BP corrosion on fuel cell performance was measured using the polarization curve, impedance, and contact resistance. The metal ion concentration in drained water was analyzed during fuel cell operation with SUS316L BP. It was confirmed that the corrosion occurs more severely at the anode than at the cathode for SUS316L BP. The contact resistance was increased due to the passivation of SUS316L during fuel cell operation, and metal ions continuously dissolved even after the passive layer formation.