• 제목/요약/키워드: Surface mating

검색결과 66건 처리시간 0.028초

Review, Assessment, and Learning Lesson on How to Design a Spectroelectrochemical Experiment for the Molten Salt System

  • Killinger, Dimitris;Phongikaroon, Supathorn
    • 방사성폐기물학회지
    • /
    • 제20권2호
    • /
    • pp.209-229
    • /
    • 2022
  • This work provided a review of three techniques-(1) spectrochemical, (2) electrochemical, and (3) spectroelectrochemical-for molten salt medias. A spectroelectrochemical system was designed by utilizing this information. Here, we designed a spectroelectrochemical cell (SEC) and calibrated temperature controllers, and performed initial tests to explore the system's capability limit. There were several issues and a redesign of the cell was accomplished. The modification of the design allowed us to assemble, align the system with the light sources, and successfully transferred the setup inside a controlled environment. A preliminary run was executed to obtain transmission and absorption background of NaCl-CaCl2 salt at 600℃. It shows that the quartz cuvette has high transmittance effects across all wavelengths and there were lower transmittance effects at the lower wavelength in the molten salt media. Despite a successful initial run, the quartz vessel was mated to the inner cavity of the SEC body. Moreover, there was shearing in the patch cord which resulted in damage to the fiber optic cable, deterioration of the SEC, corrosion in the connection of the cell body, and fiber optic damage. The next generation of the SEC should attach a high temperature fiber optic patch cords without introducing internal mechanical stress to the patch cord body. In addition, MACOR should be used as the cell body materials to prevent corrosion of the surface and avoid the mating issue and a use of an adapter from a manufacturer that combines the free beam to a fiber optic cable should be incorporated in the future design.

자동차용 전장 커넥트 프레팅 마모 손상 평가 (Evaluation of Fretting Wear Damage of Electronic Connectors for the Automotive)

  • 장승규;김덕현;김진상;최성종;조현덕
    • 한국자동차공학회논문집
    • /
    • 제22권3호
    • /
    • pp.33-41
    • /
    • 2014
  • Fretting is a kind of surface degradation mechanism observed in mechanical components and structures. When two pieces of materials, pressed together by an external static load, are subjected to a transverse cyclic loading or various vibrations, so that one contacting face is relatively displaced cyclically parallel to the other face, wear of the mating surfaces occurs. These fretting damages may be observed in electrical connectors for automotive components, where there are special environments and various vibration conditions. This study aims to evaluate the usefulness of fretting test equipment that was developed for reliability test of electrical connector. Fretting tests were carried out using tin coated connectors and friction force, contact resistance, contact area and roughness of contact region were investigated. The following results that will be helpful to understand the fretting wear mechanism, increase process the contact resistance and contact area were obtained. (1) In the same frequency and slip amplitude, the friction force, roughness and contact area increased rapidly until about $10^3$ cycles, after which it was slightly changed. (2) In the various frequency and slip amplitude, the contact area increased with slip amplitude and cyclic numbers, but it did not depend on cyclic frequency. (3) The surface roughness of contact region did not depend on the cyclic frequency. From these results, the applicability of the fretting wear test equipment and reliability of connector were discussed.

오스템퍼링 한 저합금구상흑연주철의 부식마멸특성 및 그 기구에 관한 연구 (A Study on Corrosive Wear Characteristics and the Mechanism of Austempered Low-Alloy Ductile Iron)

  • 박흥식;진동규
    • 대한기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.1404-1411
    • /
    • 1993
  • 본 연구는 오스템퍼링 온도와 유지시간을 변화시켜 오스템퍼링 한 저합금구 상흑연주철을 실험재로 하여 증류수 및 NaCI수용액 중에서의 부식마멸특성 및 그 기구 를 규명하여 Tribology 설계에 대한 자료를 제시하는 것을 목적으로 하였다.

내측연결 임플란트 시스템에서 고정체와 지대주 연결부의 적합에 관한 연구 (FIT OF FIXTURE/ABUTMENT INTERFACE OF INTERNAL CONNECTION IMPLANT SYSTEM)

  • 이흥태;정재헌
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.192-209
    • /
    • 2004
  • Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Paragon system were used. Each abutment was connected to the implant with 32Ncm torque value using a digital torque controller or tapping. All samples were cross-sectioned with grinder-polisher unit (Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc). Then optical microscopic and scanning electron microscopic(SEM) evaluations of the implant-abutment interfaces were conducted to assess quality of fit between the mating components. Results : 1) Generally, the geometry of the internal connection system provided for a precision fit of the implant/abutment into interface. 2) The most precision fit of the implant/abutment interface was provided in the case of Bicon System which has not screw. 3) The fit of the implant/abutment interface was usually good in the case of ITI, 3I and Avana system and the amount of fit of the implant/abutment interface was similar to each other. 4) The fit of the implant/abutment interface was usually good in the case of Friadent, Astra and Paragon system. The case of Astra system with the inclined contacting surface had the most Intimate contact among them. 5) Amount of intimate contact in the abutment screw thread to the mating fixture was larger in assembly with two-piece type which is separated screw from abutment such as Friadent, Astra and Paragon system than in that with one-piece type which is not seperated screw from abutment such as ITI, 3I and Avana system. 6) Amount of contact in the screw and the screw seat of abutment was larger in assembly of Friadent system than in asembly of Astra system of Paragon system. Conclusion: Although a little variation in machining accuracy and consistency was noted in the samples, important features of all internal connection systems were the deep, internal implant-abutment connections which provides intimate contact with the implant walls to resist micro-movement, resulting in a strong stable interface. From the results of this study, further research of the stress distribution according to the design of internal connection system will be required.

도금 유물에서 확인되는 확산 현상에 관한 연구 (A Study on Elemental Diffusion in Gilded Artifacts)

  • 전익환;이재성;박장식
    • 보존과학회지
    • /
    • 제26권2호
    • /
    • pp.109-120
    • /
    • 2010
  • 본 연구에서는 삼국, 고려, 조선시대의 금동유물 각 한 점과 제작시기를 알 수 없는 금동유물 한 점 그리고 고려의 금은유물 한 점을 선택하여 도금층과 바탕금속 간에 일어나는 금속원소의 확산현상을 살펴보았다. 그 결과 대부분의 유물에서 확산에 관한 직간접적인 증거가 확인되었으며, 특히 조선시대의 금동장식에 대한 분석결과로부터는 이러한 확산현상이 도금공정에 의도적으로 활용되었을 가능성이 제기되었다. 확산이 일어난 금동유물의 도금층에서는 표면에서 내부로 갈수록 점차 금함량이 감소하면서 구리함량이 증가하였으며 이로 말미암아 도금층과 바탕금속 간의 경계가 불분명해지는 것으로 드러났다. 이러한 점진적 조성변화는 열에 의한 확산에 기인하는 것으로, 도금층 전체에 산소함량이 매우 낮은 점으로 보아 이것이 매장도중 부식에 의하여 초래되었을 가능성은 매우 낮다. 확산정도에 따라 금동유물의 표면색조에는 차이가 발생하게 되는데, 확산에 의한 색조변화는 표면의 미소형태나 화학조성 면에서 부식에 의한 것과 분명하게 구별되는 것으로 밝혀졌다. 금은유물에서는 금은의 확산과 더불어 도금층의 수은도 바탕금속으로 이동하는 현상이 확인되었다.

지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구 (SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT)

  • 정석원;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

임플란트-지대주-나사의 적합에 관한 연구 (A STUDY ON THE FIT OF THE IMPLANT-ABUTMENT-SCREW INTERFACE)

  • 김낙형;정재헌;손미경;백대화
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.503-518
    • /
    • 2003
  • Statement of problem : There have been previous studies about considerable variations in machining accuracy and consistency in the implant-abutment-screw interfaces. Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combinations on two randomly selected implants from each of four manufactures. Material and methods : In this study, screws were respectively used to secure a cemented abutment, to a hexlock implant fixture ; teflon coated titanium alloy screw(Torq-Tite) and titanium alloy screw in Steri--Oss system, gold-plated gold-palladium alloy screw(Gold-Tite) and titanium alloy screw in 3i system gild screw ana titanium screw in AVANA Dental Implant system, and titanium screws in Paragon System. The implants were perpendicularly mounted in polymethyl methacrylate autopolymerizing acrylic resin block(Orthodontic resin, Densply International Inc. USA) by use of dental surveyer. Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10 minutes. All samples were cross sectioned with grinder-polisher unit(Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc) Results : There were the largest gaps in the neck areas of screws in hexagonal extension implants which were examined in this study. The leading edge of the abutment screw thread (superior surface) was in contact with the implant body thread, and the majority of the contacting surfaces were localized to the middle portion of the mating threads. Considerable variation in the contacting surfaces was noted in the samples evaluated. Amounts of contact in the abutment screw thread were larger for assemblies with Gold-Tite screw, gold alloy screw. Torq-Tite screw than those with titanium screws. The findings of intimate contact between the screw and screw seat were seen in all samples, regardless of manufacturers. However, microgap between the head and lateral neck surface of the screw and the abutment could be dectected in all samples. The findings of intimate contact between the platform of the implant and the bottom of the abutment were consistent in all samples, regardless of manufacturers. However, microgaps between the lateral surface of external hex of the fixture and the abutment could be dectected in all samples. Conclusion : Considerable variations in machining accuracy and consistency were noted in the samples and the implant-abutment-screw interfaces were incomplete. From the results of this study, further development of the system will be required, including improvements in pattern design.

CHANGES OF ABUTMENT SCREW AFTER REPEATED CLOSING AND OPENING

  • Kim Hee-Jung;Chung Chae-Heon;Oh Sang-Ho;Choi Han-Cheol
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.628-640
    • /
    • 2004
  • Statement of problem. Wear as a result of repeated closing/opening cycles may decrease the friction coefficient of screw head, threads, and other mating components and, consequently, resistance to opening gradually decreases. It may cause screw loosening, which is one of the most common failures in implant prosthesis. Purpose. The purpose of this study is to evaluate the changes on the head and thread surface of the abutment screws after repeated closing and opening through the examination of tested screws in SEM(scanning electron microscope). Materials and methods. Five species of abutments were selected (3i-three, Avana-two) respectively by two pieces. The implant fixtures were perpendicularly mounted in liquid unsaturated polyesther(Epovia, Cray Valley Inc.) with dental surveyor. Each abutment was secured to the implant fixture by each abutment screw with recommended torque value using a digital torque controller. The abutment screws were repeatedly tightened and removed 20 times with a digital controller. FESEM (field emission scanning electron microscope, Netherland, Phillips co., model:XL 30 SFEG) was used to observe changes of each part caused by repeatedly closing/opening expeiment. First, the Photomicrographs of pre-test screws provided by each manufacturer were taken. The changes of each screw were investigated after every fifth closing and opening experiment with FESEM. Scaning electron microscope photomicrographs of each screw were taken four times. Results. As the number of closing and opening was increased, the wear or distortion of hexed or squared slot that contacted with the driver tip was more severely progressed. Wear or distortion of hexed slot was more severe than that of squared slot and it was more remarkable in the titanium screw than in the gold screw. All the tested screws showed that the width in the crest of their screw thread decreased gradually as the test was proceeded. Conclusions. Conclusively, we recommend the clinical use of gold screw, a periodic exchanges of abutment screws and avoiding repeated closing/opening unnecessarily. We also suggest a more careful manipulation of the abutment screw and screw-driver and using of abutment screw with an acute-angled slot design rather than an obtuse-angled one. Finally, it is suggested that the new slot design and the surface treatment for enduring wear or distortion should be devised.

느타리 갓 표면의 소수성이 세균갈색무늬병 발병도에 미치는 영향 (Effect of Hydrophobicity of Oyster Mushroom on the Severity of Brown Blotch)

  • 이기영;양승업;한종우;윤건식;장후봉;차재순
    • 한국균학회지
    • /
    • 제38권1호
    • /
    • pp.69-74
    • /
    • 2010
  • 세균갈색무늬병 병원균의 접종에 의해 심한 병징을 보이는 느타리 균주와 매우 약한 병징을 보이는 균주를 모균주로 선발하고, 각각의 모균주로부터 얻은 단핵균주의 교배를 통해 F1 교잡균주를 얻었다. 세균갈색무늬병 발병도가 다른 11개의 F1균주와 모균주의 자실체 표면의 소수성과 발병도를 조사하였다. 발병도와 소수성 사이의 상관계수는 2번의 독립된 실험에서 각각 0.68과 070이었다. 자실체의 발병도와 버섯재배사에서 조사한 발병율 사이의 상관계수는 각각 046과 0.52이었다. GFP을 발현시킨 Pseudomonas tolaasii을 자실체표면에 접종 후 공초점현미경으로 관찰한 결과 발병도가 낮은 균주의 자실체 표면에서보다 높은 균주의 자실체 표면에서 보다 많은 세균의 집단화가 관찰되었는데, 이 결과는 발병도가 높은 균주의 갓 표면에서 더많은 세균이 증식하였음을 의미한다. 이상의 결과는 느타리 자실체 표면의 소수성이 세균갈색무늬병 발병도에 영향을 미치는 것을 암시한다. 즉 세균현탁액 방울이 갓 표면에 오래 유지되면 더 심한 병징이 형성된다.

The Effects of Multi-minerals on Susceptibility to Lead Toxicity in Rats

  • Lu, Jing;Zhang, Jun;Zhang, Lili;Cui, Tao;Xie, Guangyun;He, Xiwen
    • Toxicological Research
    • /
    • 제17권
    • /
    • pp.135-138
    • /
    • 2001
  • Female Wistar rats were randomly divided into 5 groups: Control, received distilled water; Low lead, received 0.5 g/ιlead (as acetate) in drinking water; High lead, received 2.0 g/ιlead; Low lead + Minerals, received 0.5 g/ιlead in drinking water and received minerals (Ca$^{2+}$, 25 mg/kg/day; Fe$^{3+}$, 0.47 mg/ kg/day; Zn$^{2+}$, 0.33 mg/kg/day; Se, 0.83 $\mu\textrm{g}$/kg/day) by gavage; High lead + Minerals, received 2.0 g/ιlead and received the same minerals. Animals exposure to lead was from 10 days before mating till postnatal day 21; and the minerals was administered from the first day of pregnancy and during lactation. No statistical difference was found either in body weights or in blood lead levels between the pups received minerals and those only exposed to lead at the same dose. The developmental and behavioral teratological effects of lead on pups, such as time-lag of eye opening, pinna detachment, fur developing, incisor eruption, ear unfolding, and surface righting were observed in this study; and the minerals decreased the toxicity of lead either in low or in high lead exposure pups. The numbers of step-down were significantly increased in lead exposed animals, and the effect of intervention by the minerals was appeared only in the pups exposed to low lead. The ChAT activity and levels of glutamate and aspartate in hippocampus decreased in treated animals compared to control animals, no effect of intervention by the minerals was found. The results of this study indicate that the applied multi-minerals can alter the outcome of develop-mental lead poisoning in rats.s.s.s.

  • PDF