• Title/Summary/Keyword: Surface hardness method

Search Result 506, Processing Time 0.03 seconds

A Non-Destructive Test for Strength Evaluation of Prestressed Concrete Beam Bridges (프리스트레스트 콘크리트 Beam 교량의 콘크리트 강도 평가를 위한 비파괴 검사)

  • Han, Kyoung-Bong;Chun, Young-Duk;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.1
    • /
    • pp.113-120
    • /
    • 1999
  • Due to the heterogeneous nature of a concrete, periodic inspections are compulsory to maintenance of quality of concrete structures. The major object of this study is to analyze and investigate experimentally the experimental equation for the estimate of compressive strength of prestressed concrete. In this study, surface hardness method, ultrasonic method are investigated to evaluate strength of concrete specimens. Specimens are cast in laboratory and cores are cut from specimens in order to estimate the accurate strength. These values are used to compare with calculated values from test data. The result shows that the proposed equation can reproduce the results at prestressed concrete beam girders more appropriately than previous equations.

  • PDF

Influence of soft drinks supplemented calcium to enamel remineralization (칼슘보강음료가 법랑질 재광화 효과에 미치는 영향)

  • Kim, Min-Young;Lee, Hye-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.3
    • /
    • pp.13-22
    • /
    • 2008
  • Objectives: The purpose of this study was to identify the correlation between calcium in soft drinks and enamel remineralization. Method: Six soft drinks were used in this study. These were calcium milk, normal milk, calcium yoghurt, normal yoghurt, calcium orange juice, and orange juice. Enamel specimens which 300- 400Vickers Hardness Number (VHN) were selected. These samples were immersed in each soft drink for 12 hours in an in vitro remineralization model. All specimens were processed for SEM image of the enamel surface. Results were analyzed by SPSS 13.0 package program. Results: Calcium milk was the most influential and normal yoghurt was the least to enamel surface. There was not significant difference according to calcium supplement in milk although the difference of enamel hardness was ${\Delta}f13.4$ in calcium milk, and ${\Delta}f4.7$ in normal milk (P>0.05). Other soft drinks showed a little change about calcium but they were insignificant. Demineralization effect was remarkably observed in calcium yoghurt ($-{\Delta}f269.1$) and this effect was confirmed by SEM images. In conclusion, calcium supplemented soft drinks had little influences to hardness of enamel surface.

  • PDF

Fabrication of Transparent Conducting Thin Film with High Hardness by Wet Process (습식 공정법에 의한 고경도 투명 전도막 제조)

  • Park, Jong-Guk;Jeon, Dae-Woo;Lee, Mi-Jai;Lim, Tea-Young;Hwang, Jonghee;Kim, Jin-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.12
    • /
    • pp.826-830
    • /
    • 2015
  • Transparent Ag nanowire conducting thin films with high surface hardness were fabricated by bar coating method. When coating speed was changed from 35 mm/sec to 50 mm/sec, the transmittance of coated glass increased from 65.3% to 80.8% in visible light range and the surface resistance was changed from $10.1{\Omega}/sq$ to $23.3{\Omega}/sq$. The surface hardness and adhesion of thin film were 5H and 5B.

A Study on Characteristics of TiN Thin Films Deposited by Unbalanced Magnetron Sputtering Method for the Application of Diffusion Barrier Layers in Displays (디스플레이 확산 방지층 응용을 위한 비대칭 마그네트론 스퍼터로 증착된 질화 티타늄 박막의 특성에 대한 연구)

  • Park, Yong Seob
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.2
    • /
    • pp.129-133
    • /
    • 2019
  • TiN thin films were fabricated using an unbalanced magnetron sputtering (UBMS) system, and their structure and surface characteristics as well as their optical and tribological properties were evaluated. The hardness, elastic modulus, adhesive force, surface roughness, and transmittance of the Ti thin films fabricated using the UBMS system were 11.5 GPa, 103 GPa, 27.5 N, 2.45 nm and 20%, respectively. The TiN films prepared with various proportions of nitrogen as the reaction gas exhibited maximum values for the hardness, elastic modulus, critical load, RMS roughness and transmittance of approximately 19.2 GPa, 182 GPa, 27.3 N, 0.98 nm, and 85%, respectively. Moreover, the TiN thin film fabricated under the condition of 30 sccm nitrogen gas showed the optimal physical properties. In summary, the TiN thin films fabricated using the UBMS system exhibited excellent hardness, elastic modulus, adhesion, and smooth surface in addition to good hydrophilic properties.

The Study on Estimation Fatigue Limit in Induction Surface Hardened S45C Steel (S45C강의 고주파 열처리 표면경화재 피로한도 예측에 관한 연구)

  • 이수진;전형용;성낙원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.134-142
    • /
    • 1998
  • The effects of small hole defect size and effective case depth(ECD) on the four point bending fatigue limit of induction surface hardened S45C steel were investigated the fatigue limit evaluation of hardened materials is very difficult because of relations of the hardness gradient and residual stress. In this study, it was possible to characterize fatigue limit and fatigue life of induction surface hardened S45C steel in terms of the hole defect size and effective case depth(ECD) and quantitative evaluation of the fatigue limit with hole defects use Murakami's evaluation method and the range of evaluated values is a good accuracy compared with results.

  • PDF

A Comparative Study on Tribological Characteristics between Ni-P Electroless Plating and TiAlN Coating on Anodized Aluminum Alloy (아노다이징된 알루미늄 합금에 대한 TiAlN 코팅, 무전해 Ni-P 도금의 트라이볼로지 특성 비교)

  • Lee, Gyu-Sun;Bae, Sung-Hoon;Lee, Young-Ze
    • Tribology and Lubricants
    • /
    • v.26 no.1
    • /
    • pp.68-72
    • /
    • 2010
  • A ceramic coating is a surface treatment method that is being used widely in the industrial field, recently. Ni-P plating is also being used widely because of its corrosion resistance and low cost. An anodizing method is applicable to aluminum alloy. An anodizing method generates a thick oxide layer on the surface and then, that heightens hardness and protects the surface. These surface treatments are applied to various mechanical components and treated surfaces relatively move one another. In this study, tribological characteristics of Ni-P plating and TiAlN coating on anodized Al alloy are compared. The counterpart, anodized Al alloy, is worn out abrasively by Ni-P plating and TiAlN coating that have higher hardness. Abrasively worn debris accumulated on the surfaces of Ni-P plating and TiAlN coating, and then transferred layer is formed. This transferred layer affects the amplitude of variation of friction coefficient, which is related to noise and vibration. The amplitude of variation of friction coefficient of Ni-P plating is lower than those of TiAlN coating during the tests.

Development of Corrosion Rust Removing Unit for Small Ship Propeller (소형선박용 프로펠러의 부식 녹 제거장치 개발)

  • Kim, Gui-Shik;Han, Se-Woong;Hyun, Chang-Hae
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.6 s.67
    • /
    • pp.72-77
    • /
    • 2005
  • The materials used in a ship screw propeller are commonly made with brass. The seawater corrosion and seawater cavitation of the screw propeller reduces the propulsive performance of the ship. In screw manufacturing, the corrosion rust of the screw propeller is removed through a hand grinding method. The grinding process produces dust of the heavy metals from the brass. The dust creates a poor working environment that is harmful to the health of the workers. An automatic corrosionrust removing apparatus, using a blasting method, was developed for the improvement of screw polishing conditions and its working environment. The performance of this apparatus was investigated by surface roughness, weight loss rate, hardness, electrochemical corrosion resistance, and cavitation erosion, after removing of the corrosion rust under various blasting conditions. Two medias of alumina and emery were used in this experiment. The surface roughness and hardness of the screw were improved by this apparatus. The electrochemical corrosion potential (Ecorr) and current density (Icorr) were measured by the dynamic polarization method, using a potentiostat,under the conditions of surface polishing with grinding, blasting, wire brushing, and fine sand papering. The test results prove that the new corrosion rust-removing apparatus improves the surface performance of a screw propeller.

A STUDY ON THE RESISTANCE OF WEAR AND CYTOTOXICITY OF THE TITANIUM SURFACE AFTER FILM DEPOSITIONS (박막증착시 티타늄 표면의 마손저항도와 세포독성에 관한 연구)

  • Kim Hyung-Woo;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.84-95
    • /
    • 2001
  • Titanium is widely used in dentistry for its low density, high strength, fatigue resistance, corrosion resistance, and biocompatibility. But it has a tendency of surface damage under circumstance of friction and impact for its low hardness of the surface. Coating is one of methods fir increasing surface hardness. Its effect is to improve surface physical characteristics without change of titanium. Diamond-like carbon and titanium nitride are known for its high hardness of the surface. So that this study was aimed at the wear test and the cytotoxicity test of the commercially pure titanium and Ti-6Al-4V alloy which were deposited by diamond-like carbon film or titanium nitride film to acertain improvement of the surface hardness and the biocompatibility. A disk (25mm diameter, 2mm thickness) was made of commercially pure titanium and Ti-6Al-4V alloy and these substrates were deposited by diamond-like carbon film or titanium nitride film. Diamond-like carbon film was deposited by the method of radiofrequency plasma assisted chemical vapor deposition and titanium nitride film was deposited by the method of reactive arc ion plating. Then these substrates were tested about wear characteristics by the pin-on-disk type wear tester in which ruby ball was used as a wear causer under the load of 32N, The fracture cycles were measured by rotating the substrates until their films were fractured. The wear volume was measured after 150 cycles and 3,000 cycles using surface profiler. The cytotoxicity test was peformed by the method of the MTT assay. The results were as follows : 1. In the results of the wear volume test, commercially pure titanium and titanium alloy which were coated by diamond-like carbon film or titanium nitride aim had higher resistance against wear than the substrates which were not coated by any films (P<0.05). 2. In the results of the fracture cycle test and the wear volume test, diamond-like carbon film had higher resistance against wear than titanium nitride film (P<0.05). 3. In both coatings of diamond-like carbon aim and titanium nitride film, Ti-6Al-4V alloy had higher resistance against wear than commercially pure titanium (P<0.05) 4. In the results of the cytotoxicity test, diamond-like carbon film and titanium nitride film had little cytotoxicity as like commercially pure titanium or Ti-6Al-4V alloy (P>0.05).

  • PDF

Study of Pd Target Power Effects on Physical Characteristics of Pd-Doped Carbon Thin Films Using Dual Magnetron Sputtering Method (듀얼 마그네트론 스퍼터링 법으로 제조된 Pd-Doped Carbon 박막의 물리적 특성에서 Pd 타겟 전력의 영향에 대한 연구)

  • Choi, Young-Chul;Park, Yong Seob
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.488-493
    • /
    • 2022
  • Generally, diamond-like carbon films (a-C:H, DLC) have been shown to have a low coefficient of friction, a high hardness and a low wear rate. Pd-doped C thin film was fabricated using a dual magnetron sputtering with two targets of graphite and palladium. Graphite target RF power was fixed and palladium target RF power was varied. The structural, physical, and surface properties of the deposited thin film were investigated, and the correlation among these properties was examined. The doping ratio of Pd increased as the RF power increased, and the surface roughness of the thin film decreased somewhat as the RF power increased. In addition, the hardness value of the thin film increased, and the adhesive strength was improved. It was confirmed that the value of the contact angle indicating the surface energy increases as the RF power increases. It was concluded that the increase in RF power contributed to the improvement of the physical properties of Pd-doped C thin film.

Creep Damage Evaluation of High-Temperature Pipeline in Power Plant by Using Ultrasonic Velocity Measurement and Hardness Test (초음파 음속 및 경도법에 의한 발전소 고온배관재의 크리프 손상평가)

  • Hur, Kwang-Beom;Yoo, Keun-Bong;Cho, Yong-Sang;Lee, Sang-Guk
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3 s.33
    • /
    • pp.92-99
    • /
    • 1999
  • High temperature and pressure materials in power plant are degraded by creep damage, if they are exposed to constant loads for long times, which occurs in load bearing structures of pressurized components operationg at elevated temperatures. Many conventional measurement techniques such as replica method, electric resistance method, and hardness test method for measuring creep damgage have been used. So far, the replica method is mainly used for the inspection of high temperature and pressure components. This technique is, however, restricted to applications at the surface of the testpieces and cannot be used to material inside. In this paper, ultrasonic evaluation for the detection of creep damage in the form of cavaties on grain boundaries or intergranular microcracks were carried out. And the absolute measuring method of quantitative ultrasonic velocity technique for Cr-Mo material degradation was analyzed. As a result of ultrasonic tests for crept for specimens, we founded that the sound velocity was decreased as increase of creep life fraction(${phi}c$) and also, confirmed that hardness was decreased as increase of creep life fraction(${phi}c$).

  • PDF