• 제목/요약/키워드: Surface electric property

Search Result 108, Processing Time 0.035 seconds

Influence of Activation Temperature on Electrochemical Performances of Styrene-Acrylonitrile Based Porous Carbons (Styrene-Acrylonitrile 기반 다공성 탄소의 전기화학적 특성에 활성화 온도가 미치는 영향)

  • Lee, Ji-Han;Heo, Gun-Young;Park, Soo-Jin
    • Polymer(Korea)
    • /
    • v.36 no.6
    • /
    • pp.739-744
    • /
    • 2012
  • In this work, we prepared the carbons from synthesized styrene-acrylonitrile carbon precursor. The prepared carbons were chemically activated, and then the activated SAN-based carbons were named as A-SANs. The activations were carried out at different temperatures to investigate the effect of activation temperature on the surface and electrochemical properties of the activated SAN-based carbons for using as an electrode of electric double layer capacitors (EDLC). The characteristics of A-SAN were determined by X-ray diffraction (XRD), scanning electron microscopy (SEM), surface area and pore size analysis. Also, the electrochemical behaviors were observed by cyclic voltammetry and galvanostatic charge-discharge method. From the results, the A-SAN 700 showed excellent electrochemical property and the highest specific capacitance, but these properties decreased when the activation temperature was above $700^{\circ}C$. This is due to the fact that the activation at a temperature over $700^{\circ}C$ causes deformation of micropore structures.

A Performance Evaluation of Concrete for Low-carbon Eco-friendly PC Box for Near-surface Transit System (저심도 철도시스템 구축을 위한 저탄소 친환경 PC 박스용 콘크리트의 성능 평가)

  • Koh, Tae-Hoon;Ha, Min-Kook;Jung, Ho-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3587-3595
    • /
    • 2015
  • Low-carbon eco-friendly precast concrete (PC) box structure has been recently was developed as an low-cost infrastructure of near-surface transit system. The concrete of PC box was manufactured by industrial byproducts such as ground granulated blast furnace (GGBF) slag, flyash and rapid-cooling electric arc furnace (EAF) oxidizing slag, its mechanical property and durability were estimated in this study. Based on the mechanical and durability tests, it is found that low-carbon eco-friendly concrete shows high initial compressive strength, more than 90% of design strength (35MPa), and high resistance to salt-attack, chemical- attack and freeze-thaw. Therefore, low-carbon eco-friendly PC box concrete technology is expected to contribute to the railway with low environmental impact.

DETORQUE FORCE OF TiN-COATED ABUTMENT SCREW WITH VARIOUS COATING THICKNESS AFTER REPEATED CLOSING AND OPENING

  • Kim, Han-Su;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.769-779
    • /
    • 2007
  • Statement of problem. When TiN coating is applied to the abutment screw, occurrence of greater preload and prevention of the screw loosening could be expected due to decrease of frictional resistance. However, the proper thickness of TiN coating on abutment screw has not been yet reported. Purpose. The purpose of this study is to find out the appropriate TiN coating thickness by evaluating the detorque force and the surface change of titanium abutment screw with various TiN coating thickness. Material and methods. 1. Material Thirty five non-coated abutment screws were prepared for TiN coating. TiN coatings were prepared by Arc ion plating method. Depending on the coating deposition time(CDT), experimental groups were divided into 6 groups(CDT 30min, 60min, 90min, 120min, 150min, 180min) and those of 1 group was not coated as a control group. Each group was made up of 5 abutment screws. 2. Methods FE-SEM(Field Emission Scanning Electron Microscoper) and EDX(Energy Dispersive X-ray Spectroscopy) were used to observe the surface of the abutment screw. Electric scales was used to measure the weight of the abutment screw after the repeated closing and opening of 10 trials. Detorque force was measured with digital torque gauge, at each trial. Results. 1. As the coating deposition time increased, the surface became more consistent and smooth. 2. As for the abutment screws that were TiN coated for more than 60 minutes, no surface change was found after the repeated closing and opening. 3. The TiN coated abutment screws showed less weight change than the non-coated abutment screws. 4. The TiN coated abutment screws showed higher mean detorque force than the noncoated abutment screws. 5. The abutment screw coated for 60 minutes showed the highest mean detorque force. Conclusion. The coating layer of proper thickness is demanded to obtain consistent and smooth coating surface, resistance to wear, and increased detorque force of the abutment screw. In conclusion, the coating deposition time of 60 minutes indicated improved mechanical property, when TiN coating was conducted on titanium abutment screw.

A study on the Manufacture and Application of UV-Cured Anti-stain Coating Compounds for PVC Tile (PVC 바닥상재용 광경화형 내오염 코팅액의 제조 및 응용에 관한 연구)

  • Yoon, Hyun-Jung;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1741-1746
    • /
    • 2010
  • This study is on development of UV-cured anti-stain coating compounds which have more improved anti-stain function to prevent a surface of PVC tile from stain. To make an anti-stain coating composition, water soluble antistatic agent made from ammonium(IV) salt, antistatic agents for acrylic and polyurethane were used. Their contents varied from 5 to 20wt% against quantities of resin in coating composition. After coating PVC tiles using bar-coating method that can adjust a thickness, we estimated surface properties of coated layer such as anti-stain, electric resistance, adhesive power, thickness of coating, and so on. Results showed that a coating composition added 15wt% of water soluble antistatic agent and coated with No.12 bar-coater had the optimum surface property in electric resistance($3.24{\times}10^9{\Omega}/cm^2$), anti-stain(ink Test, Dust Test) and adhesive power. We could also find electric resistance and anti-stain effect were improved as antistatic agent content increased. However, excessive addition of antistatic agents(over 20wt%) caused the migration.

Bacterial Behavior in Soil under Electric Field and its Effect on Electrokientic Bioremediation (전기장하 토양내에서 미생물 이동특성과 동전기 생물학적복원의 효과)

  • Kim, Sang-Joon;Park, Ji-Yeon;Lee, You-Jin;Yang, Ji-Won
    • KSBB Journal
    • /
    • v.21 no.3
    • /
    • pp.175-180
    • /
    • 2006
  • In this study, it could be found that the microbial movement in soil under electric field mainly occurred by electrophoresis and electroosmosis. The contribution of electrophoresis on the microbial mobility and flux was generally higher than that of electroosmosis. In the electrokinetic(EK) bioremediation of a pentadecane-contaminated soil, the microbial population increased simultaneously at anode and cathode regions of the soil specimen because both electrophoresis and electroosmosis affected on the microbial movement. After initial operation, the microbial population was high in order of anode, middle, and cathode regions due to their negatively-charged surface and oxygen generation at anode. However, the uniform contaminant removal was achieved by the microbial movement with two-directionality.

Electric Corrosion of STS304 Acupuncture Needles Used for Electroacupuncture (STS304 스테인리스 강선 호침에서 전침 자극 후 침체에 나타나는 전기적 부식 연구)

  • Hwang, Hye-Suk;Koo, Sung-Tae;Ryu, Yeon-Hee;Jeong, Sang-Yong;Kim, Yu-Sung;Lee, Ji-Eun;Han, Kyung-Ju;Choi, Sun-Mi
    • Journal of Acupuncture Research
    • /
    • v.24 no.5
    • /
    • pp.105-111
    • /
    • 2007
  • Objectives : The electroacupuncture(EA) was often used in Oriental medicine clinic and basic researches. However, there have been neither any national standard of acupuncture needles in Korea nor many studies about the property of acupuncture needles for applying electrical stimulations. Therefore we investigated the electrical corrosion property of acupuncture needles used for EA stimulation in clinic. Methods : We observed the occurrence of electrical corrosion like changes in the surface of acupuncture needles after EA stimulation with various parameters(electrical stimulation intensity, treatment duration, diameter of needle) under a light microscope. We performed EA stimulation on Baekhoe($GV_{20}$) or Joksamli($ST_{36}$) of rats with intensity of 0.025, 0.05, 0.075, 0.1, 0.25 or 0.5mA at a 10Hz frequency. Results : The electrical corrosion-like changes were found on the surface of needles when the EA stimulation was given over 0.05mA of intensity. When electrical stimulation was treated for 10min, the electrical corrosion-like changes were low, but the electrical corrosion-like changes gradually increased by the treatment duration(20, 30min). We also found that acupuncture needles of 0.2mm diameter were produced more extensive electrical corrosion-like changes than acupuncture needles of 0.3 or 0.4mm diameter by electrical stimulation. Conclusions: These results suggested that EA stimulation could produce electrical corrosion-like changes of acupuncture needles through intensity of current, duration of electric stimulation and/or diameter of needle.

  • PDF

Characteristics of Molecular Band Energy Structure of Lipid Oxidized Mammalian Red Blood Cell Membrane by Air-based Atmospheric Pressure Dielectric Barrier Discharge Plasma Treatment

  • Lee, Jin Young;Baik, Ku Youn;Kim, Tae Soo;Jin, Gi-Hyeon;Kim, Hyeong Sun;Bae, Jae Hyeok;Lee, Jin Won;Hwang, Seung Hyun;Uhm, Han Sup;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.262.1-262.1
    • /
    • 2014
  • Lipid peroxidation induces functional deterioration of cell membrane and induces cell death in extreme cases. These phenomena are known to be related generally to the change of physical properties of lipid membrane such as decreased lipid order or increased water penetration. Even though the electric property of lipid membrane is important, there has been no report about the change of electric properties after lipid peroxidation. Herein, we demonstrate the molecular energy band change in red blood cell membrane through peroxidation by air-based atmospheric pressure DBD plasma treatment. Ion-induced secondary electron emission coefficient (${\gamma}$ value) was measured by using home-made gamma-focused ion beam (${\gamma}$-FIB) system and electron energy band was calculated based on the quantum mechanical Auger neutralization theory. The oxidized lipids showed higher gamma values and lower electron work functions, which implies the change of surface charging or electrical conductance. This result suggests that modified electrical properties should play a role in cell signaling under oxidative stress.

  • PDF

Synthesis of Core/Shell Graphene/Semiconductor Nanostructures for Lithium Ion Battery Anodes

  • Sin, Yong-Seung;Jang, Hyeon-Sik;Im, Jae-Yeong;Im, Se-Yun;Lee, Jong-Un;Lee, Jae-Hyeon;Wang, Junyi;Heo, Geun;Kim, Tae-Geun;Hwang, Seong-U;Hwang, Dong-Mok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.288-288
    • /
    • 2013
  • Lithium-ion battery (LIB) is one of the most important rechargeable battery and portable energy storage for the electric digital devices. In particular, study about the higher energy capacity and longer cycle life is intensively studied because of applications in mobile electronics and electric vehicles. Generally, the LIB's capacity can be improved by replacing anode materials with high capacitance. The graphite, common anode materials, has a good cyclability but shows limitations of capacity (~374 mAh/g). On the contrary, silicon (Si) and germanium(Ge), which is same group elements, are promising candidate for high-performance LIB electrodes because it has a higher theoretical specific capacity. (Si:4200 mAh/g, Ge:1600 mAh/g) However, it is well known that Si volume change by 400% upon full lithiation (lithium insertion into Si), which result in a mechanical pulverization and poor capacity retention during cycling. Therefore, variety of nanostructure group IV elements, including nanoparticles, nanowires, and hollow nanospheres, can be promising solution about the critical issues associated with the large volume change. However, the fundamental research about correlation between the composition and structure for LIB anode is not studied yet. Herein, we successfully synthesized various structure of nanowire such as Si-Ge, Ge-Carbon and Si-graphene core-shell types and analyzed the properties of LIB. Nanowires (NWs) were grown on stainless steel substrates using Au catalyst via VLS (Vapor Liquid Solid) mechanism. And, core-shell NWs were grown by VS (Vapor-Solid) process on the surface of NWs. In order to characterize it, we used FE-SEM, HR-TEM, and Raman spectroscopy. We measured battery property of various nanostructures for checking the capacity and cyclability by cell-tester.

  • PDF

Electrical and Chemical Properties of Mica/Epoxy Composite Materials as Affected by Short-Time Aging

  • Kim, Hee-Dong
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.2
    • /
    • pp.59-65
    • /
    • 2003
  • Electrical properties such as permittivity and tan$\delta$ of unaged (control) and aged (72 h at 18$0^{\circ}C$) mica/epoxy composites of 130 ${\mu}{\textrm}{m}$ thickness were measured and their surface conditions were characterized using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), electron spectroscopy for chemical analysis (ESCA), differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). Both permittivity and tan6 of control specimens were higher than those of short-time aged specimens. FTIR results show a new peak at 1710 $cm^{-1}$ / for short-time aged specimens, originating from carbonyl group formed by the oxidation reaction during the aging process. ESCA results show that the binding energy at 532.9 eV representing the singlet state of oxygen ( $O_{1s}$) decreases by 13.7%, whereas that at 534.6 eV increases by 13.7%. Glass transition temperatures of control and short-time aged specimens are observed to be 95.4$^{\circ}C$ and 113.4$^{\circ}C$, which increase with the increase of aging time. TGA results indicate that the control specimens contain a smaller amount of volatile components than the short-time aged specimens.s.

The Study of Dark Current of Amorphous Selenium Plate for Digital Radiography Applications (Digital Radiography용 amorphous selenium 시편의 누설전류에 관한 연구)

  • Kang, Y.S.;Kang, W.S.;Jung, S.H.;Park, S.K.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.293-294
    • /
    • 1998
  • In this paper, the electric properties of amorphous selenium specimen has been investigated. Amorphous selenium was thermally evaporated on the glass plate which had been deposited onto the interface by aluminium as an electrode. On the surface of the amorphous selenium, the aluminium electrode was deposited again in order to make an unit cell for dark current measurement. The dark current was measured while applying the bias voltage across the selenium layer in the range of 0V-2500 Volts. The leakage property of the amorphous selenium was significantly low at even high voltage range so it has good advantage as a X-ray receptor for digital radiography. For further study, the C-V curves measurement according to thicker amorphous selenium layer.

  • PDF