• 제목/요약/키워드: Surface Solar Radiation

검색결과 383건 처리시간 0.027초

NFRC 201 실험방법에 의한 내부 차양장치가 적용된 창호의 일사획득계수 평가 (Evaluation on the Solar Heat Gain Coefficient of Glazing System installed in internal shading device by experiments according to the NFRC 201)

  • 임재한;송승영
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.47-54
    • /
    • 2010
  • Recently the researchers has been interested in the development of the high performance windows such as solar control window using automatic shading devices, air-flow window, selective coating window. In order to assess the energy performance of total fenestration system, the net energy gains or losses through the glazings and windows should be evaluated. It depends on the thermal transmittance (U-value) and the total solar energy transmittance (SHGC, g-value). This study aims to measure the solar heat gain coefficient according to the NFRC 201 standard test method. In results, we could find the result of different SHGC of the glazing system with a different slat angles. The SHGC in case of $90^{\circ}$ of internal slat angle with regard to the window surface is about 0.56, that in case of $45^{\circ}$ is about 0.49 and that in case of $0^{\circ}$ is about 0.33. Significant dependence on the solar radiation intensity and incident angle was found in comparison of the measured and simulated SHGC.

태양 선택흡수막의 특성 분석 (Property Analysis of Solar Selective Coatings)

  • 이길동
    • 한국태양에너지학회 논문집
    • /
    • 제33권4호
    • /
    • pp.31-38
    • /
    • 2013
  • The chemical composition of the black Cr solar selective coatings electrodeposited were investigated for property analysis by using a XPS(X-ray photoelectron spectroscopy) before and after annealing in air at $300^{\circ}C{\sim}500^{\circ}C$ for 120 hours. Black Cr selective coating exposed by solar radiation for 5 months was compared with annealed sample. In addition, The Cu solar selective coatings were prepared by thermal oxidation method for low temperature application. The samples obtained were characterized by using the optical reflectance measurements by using a spectrometer. Optical properties of oxidized Cu solar coatings were solar absorptance $({\alpha}){\simeq}0.62$ and thermal emittance $({\epsilon}){\simeq}0.41(100^{\circ}C)$. In the as-prepared Cr black selective coating, the surface of the coating was found to have Cr hydroxide and Cr. The Cr hydroxide of the major component was converted to $Cr_2O_3$ or $CrO_3$ form after annealing at $500^{\circ}C$ with the desorption of water molecules. The black Cr selective coating was degraded significantly at temperature of $500^{\circ}C$. The main optical degradation modes of this coating were diffusion of Cu substrate materials.

전자선 조사에 따른 폴리이미드 필름의 유전특성 변화 (Effects of Electron Beam Irradiation on the Dielectric Properties of Polyimide Films)

  • 김현빈;전준표;강필현
    • 방사선산업학회지
    • /
    • 제4권3호
    • /
    • pp.285-288
    • /
    • 2010
  • Polyimide films have excellent thermal stability, reliable mechanical properties and low dielectric constant. Therefore, this material is widely used in many industrial fields such as microelectronics, flexible circuits, semiconductor products and aerospace materials. In space applications, earth-orbiting hardware operates in environments that generally include neutral particles, charged particles such as trapped protons and electrons, solar protons, and cosmic rays. Under these conditions, polyimide films were changed in the optical, electrical and mechanical properties. Therefore, in this study, we evaluated the effects of electron beam irradiation on polyimide. The O-H functional groups were created on the polyimide film surface in the results of FT-IR spectra. And it was found that the dielectric constants were changed as a function of electron beam dose.

표면방사율에 따른 복사단열시스템의 열관류성능 평가 연구 (Evaluation of U-value for Radiant Barrier Systems in Relation to Surface Emissivity)

  • 김기세;이동규;윤종호;송인춘
    • 태양에너지
    • /
    • 제20권3호
    • /
    • pp.39-50
    • /
    • 2000
  • Radiant barrier systems(RES) constructed with low emissivity materials bounded by an open air space can be used to reduce the net radiation transfer between two surfaces. To analyze the heat transfer characteristics of the radiant barrier systems which consist of a single-glass and radiation barriers, a simple theoretical model based on energy balances was suggested. And the model was validated by means of the experimental results. Using a guarded hot box, the temperatures of layers in selected RES and energy use for each cases were measured. The results show that the model well explained the heat transfer characteristics of those RES. Also, the heat transfer coefficient correlations considering natural and forced convection heat transfer ware suggested. It is found that the heat transfer efficiency of a RBS with aluminium surface improved up to 66.6% over that of a single glazing system.

  • PDF

천공상태에 따른 박막 BIPV 창호의 온도 및 발전특성 실측연구 (A Study on Optimum of Performance Objectives of Passive House with Load Reduction elements)

  • 김빛나;윤종호;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.171-176
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temporature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish mornitoring system and analysis the date from the mornitoring system to evaluate the performance of PV windows that has thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

  • PDF

제주도 고산지역 자외선복사의 월변화 특성과 원인 고찰 (A Study on the Monthly Characteristics of Solar UV Radiation in Gosan, Jeju)

  • 김영아;최우갑
    • 대기
    • /
    • 제27권3호
    • /
    • pp.291-300
    • /
    • 2017
  • The monthly-mean irradiance of ultra violet (UV)-B and UV-A observed from 2005 to 2014 and 2012 to 2014, respectively, at noon in Gosan, Jeju, South Korea are analyzed. We compare cloudiness, total ozone, visibility, and relative humidity with an emphasis on the four months from May to August (MJJA), which shows the largest UV radiation. While the incoming UV-B radiation at the top of the atmosphere in Gosan is the largest in June due to the small solar zenith angle, the observed surface UV-B shows an unexpected smaller value in June than those in May, July or August. In June, the meteorological conditions affecting Gosan are completely dominated by cloudiness and thus, frequent overcast seems to determine the minimum UV-B. Another important UV-determining factor is the total ozone, which exhibits a monotonic decrease during MJJA without agreeing to the characteristic feature of UV. The ratio of UV-B to UV-A is not generally influenced by cloudiness. Thus, the ratio is a useful indicator of atmospheric turbidity showing larger values for increasing visibility, except in June. A simple model has been used to estimate surface UV by using the observed ozone and visibility in the cloudless condition. The result shows that UV has the lowest value in June with small variation during MJJA. Model estimation also shows that the different characteristic features observed in July between surface UV-B and UV-A is the result of less absorption of UV-B by ozone than that of UV-A by a smaller amount of total ozone.

Calibration of the Pyranometer Sensitivity Using the Integrating Sphere

  • Kim, Bu-Yo;Lee, Kyu-Tae;Zo, Il-Sung;Lee, Sang-Ho;Jung, Hyun-Seok;Rim, Se-Hun;Jang, Jeong-Pil
    • Asia-Pacific Journal of Atmospheric Sciences
    • /
    • 제54권4호
    • /
    • pp.639-648
    • /
    • 2018
  • The pyranometer for observing the solar radiation reaching the surface of the earth is manufactured by various companies around the world. The sensitivity of the pyranometer at the observatory is required to be properly controlled based on the reference value of the World Radiometric Center (WRC) and the observatory environment; otherwise, the observational data may be subject to a large error. Since the sensitivity of the pyranometer can be calibrated in an indoor or outdoor calibration, this study used a CSTMUSS-4000C Integrating Sphere by Labsphere Inc. (USA) to calibrate the sensitivity of CMP22 pyranometer by Kipp&Zonen Inc. (Netherlands). Consequently, the factory sensitivity of CMP22 was corrected from $8.68{\mu}V{\cdot}(Wm^{-2})^{-1}$ to $8.98{\mu}V{\cdot}(Wm^{-2})^{-1}$, and the result from the outdoor calibration according to the observatory environment was $8.90{\mu}V{\cdot}(Wm^{-2})^{-1}$. After the indoor calibration of the pyranometer sensitivity, the root mean square error (RMSE) of the observational data at the observatory on a clear day without clouds (July 13, 2017) was $7.11Wm^{-2}$ in comparison to the reference pyranometer. After the outdoor calibration of the pyranometer sensitivity based on these results, the RMSE of the observational data was $1.74Wm^{-2}$ on the same day. Periodic inspections are required because the decrease of sensitivity over time is inevitable in the pyranometer data produced at the observatory. The initial sensitivity after indoor calibration ($8.98{\mu}V{\cdot}(Wm^{-2})^{-1}$) is important, and the sensitivity after outdoor calibration ($8.90{\mu}V{\cdot}(Wm^{-2})^{-1})$ can be compared to the data at the Baseline Surface Radiation Network (BSRN) or can be used for various studies and daily applications.

에너지 생산성 분석 기반 양면발전형 수직 태양전지의 활용 가능성 탐색 (A Study on the Applicability of Double-Sided Vertical Photovoltaic Panels Based on Energy Productivity Analysis)

  • 최승주;한승훈
    • 신재생에너지
    • /
    • 제19권4호
    • /
    • pp.84-97
    • /
    • 2023
  • This study aimed to investigate the feasibility and potential applications of utilizing bifacial photovoltaic (PV) panels from an architectural perspective. It also aimed to establish a foundational dataset for installation and operational guidelines for bifacial PV panels through a comparative analysis of energy production performance with single PV panels. The research encompassed several key steps, including a comprehensive literature review, calculation of solar surface radiation values, development of datasets for bifacial and single PV energy production, and a performance comparison between both approaches. The results of the study show that bifacial PV panels exhibit optimized energy production capabilities within the range of 40 to 80 degrees, contingent upon the specific installation location. Consequently, it is recommended that the installation of bifacial PV panels in Korea should primarily focus on southwest-to-west orientation. Furthermore, it was concluded that bifacial PV panels could contribute an equivalent or even superior level of energy production compared to single PV panels, even if their performance exhibited a marginally lower efficiency of 2% to 5% with an 18% power generation efficiency.

지형 효과를 고려한 지표면 태양광 분포 (Distribution of Photovoltaic Energy Including Topography Effect)

  • 지준범;조일성;이규태;최영진
    • 한국지구과학회지
    • /
    • 제32권2호
    • /
    • pp.190-199
    • /
    • 2011
  • 지형 효과가 포함된 태양복사 모델(GWNU)을 이용한 한반도의 태양광 자원지도를 개발하였다. 태양복사 모델의 입력 자료는 위성 관측 자료(MODIS, OMI, MTSAT-1R)와 수치 모델(RDAPS) 자료를 사용하였으며 특히 고해상도 지형 자료를 이용하여 지형 효과에 따른 한반도의 지표면 태양광 변화를 계산하였다. 계산 결과를 월 및 연 누적하여 분석하였을 때 여름철은 태양 고도각이 높아 지형 효과에 영향이 10% 이하로 적은 반면 겨울철은 20% 이상의 큰 차이가 나타났다. 또한 4 km 해상도의 지표면 태양광의 경우보다 1 km 해상도의 경우 지형 효과 포함에 따른 태양광 차이가 약 2배 정도 크게 나타났다. 즉 지표면에 도달하는 태양광을 정확히 모델링하기 위해서는 입력 자료뿐만 아니라 정확하고 고해상도의 지형 자료가 필연적이며 지형효과는 더욱 뚜렷이 나타나 실제와 유사할 것이다.

양면형 BIPV 시스템의 설치환경에 따른 발전특성 분석 (Analysis of Generation Characteristics of a Bifacial BIPV System According to Installation Methods)

  • 강준구;김진희;김준태
    • Current Photovoltaic Research
    • /
    • 제3권4호
    • /
    • pp.121-125
    • /
    • 2015
  • BIPV system is one of the best ways to harness PV module. The BIPV system not only produces electricity, but also acts as a building envelope. Thus, it has the strong point of increasing the economical efficiency by applying the PV modules to the buildings. Bifacial solar cells can convert solar energy to electrical energy from both sides of the module. In addition, it is designed as 3 busbar layout which is the same with ordinary mono-facial soalr cells. Therefore, many of the module manufacturers can easily produce the bifacial solar cells without changing their manufacturing equipment. Moreover, bifacial BIPV system has much potential in building application by utilizing glass to glass structure. However, the performance of bifacial solar cells depends on a variety of factors, ranging from the back surface to surrounding conditions. Therefore, in order to apply bifacial solar cells to buildings, an analysis of bifacial PV module performance should be carried out that includes a consideration of various design elements, and reflects a wide range of installation conditions. As a result it found that the white insulation reflector type can improve the performance of the bifacial BIPV system by 16%, compared to the black insulation reflector type. The performance of the bifacial BIPV was also shown to be influenced by inclination angle, due to changes in both the amount of radiation captured on the front face and the radiation transmitted to the rear face through the transparent space. In this study is limited design condition and installation condition. Accordingly follow-up researches in this part need to be conducted.