• Title/Summary/Keyword: Surface Compatibility

Search Result 267, Processing Time 0.023 seconds

Interaction of Fibroblast Cells onto Chloric Acid-treated Poly($\alpha$-hydroxy acid) Polymer Surfaces (염소산 처리된 Poly($\alpha$-hydroxy acid)계 고분자 표면과 섬유아세포의 상호작용)

  • 이상진;강길선;이진호;이영무;이해방
    • Polymer(Korea)
    • /
    • v.24 no.6
    • /
    • pp.877-885
    • /
    • 2000
  • PLA, PGA and PLGA films were treated with chloric acid mixture solution [70% perchloric acid (HClO$_4$)/potassium chlorate (KClO$_3$) aq. saturated solution, 3 : 2] to increase surface wettability and thus cell compatibility. The surface-treated PLA, PGA, and PLGA films were characterized by the measurement of water contact angle, electron spectroscopy for chemical analysis, and scanning electron microscopy. Surface wettability of chloric acid-treated PLA, PGA, and PLGA film surfaces was gradually increased with increase of treatment time. Unlike EtOH pre-treatment, chloric acid-treated polymer films maintain hydrophilic surface after drying. In cell adhesion test, fibroblasts were cultured on the chloric acid-treated film surfaces for 1 and 2 days. As the surface wettability increased, the cell adhesion on the surface were increased. In conclusion, this study demonstrated that the surface wettability of polymer plays an important role for cell adhesion and proliferation behavior.

  • PDF

A Study on the Compatibility of Nanocellulose-LDPE Composite (나노셀룰로오스-LDPE 복합체의 제조에 있어서 상용성에 대한 연구)

  • Cho, Eun Hyeong;Kim, Young Ho
    • Clean Technology
    • /
    • v.27 no.2
    • /
    • pp.124-131
    • /
    • 2021
  • As declarations of carbon neutrality are spreading throughout the world, much research is being conducted on biodegradable polymers. In this study, nanocellulose, which comprises the largest amount of natural polymer currently available in the world, was proposed as a substitute for non-biodegradable polymers. We chose to modify the surface functional group of crystalline nanocellulose using glycidoxypropyl trimethoxysilane (GPTMS), which is a silane coupling agent, and the product was then used to form a film with low density polyethylene (LDPE). We then conducted measurements using a Fourier transform infrared spectrophotometer (FT-IR) in addition to measuring hydrophilic/lipophilicity of the surface functional group modification of crystalline nitrocellulose as well as that of a polymer composite using the hybrid nanocellulose (H-NC). For compatibility with petroleum-based polymers, the best tensile strength and transparency was found when the H-NC was reacted at pH 14 and 1 wt% compared with LDPE. From the test results, we found that it is possible to modify the surface functional groups of nanocellulose using a silane coupling agent. In addition, the high compatibility of nanocellulose with petroleum-based polymers is expected to help in reaching carbon neutrality by reducing the use of fossil fuels.

Enhanced Blood Compatibility of PEO-Grafted and Sulfonated Polyurethanes (폴리에틸렌옥사이드 및 설폰산이 결합되어 혈액적합성이 개선된 개질 폴리우레탄)

  • Han, D.K.;Jeong, S.Y.;Ahn, K.D.;Kim, Y.H.;Kim, U.Y.;Cho, H.I.;Min, B.G.;Choi, J.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.5-6
    • /
    • 1989
  • Polyurethane surface was chemically modified to have different hydrophilic polyethyleneoxide(PEO)/hydrophobic dodecanediol(DDO) groups and negatively charged sulfonate group to investigate the effect to the antithrombogenicity. The hydrophilicity of the surface was significantly increased after PEO grafting or sulfonation. Lowering in-vitro platelet adhesion led to a prologation in the ex-vivo occlusion time. Especially, the sulfonated PU-PEO surface showed most enhanced blood compatibility due to the synergistic effects of PEO and $SO_3$ groups.

  • PDF

RF Compatibility Design & Verification for the SAR Satellite (SAR 위성의 고주파 호환성 설계 및 검증)

  • Won, Young-Jin;Park, Hong-Won;Moon, Hong-Youl;Woo, Sung-Hyun;Kim, Jin-Hee
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.37-48
    • /
    • 2011
  • Synthetic Aperture Radar(SAR) is a powerful and well established microwave remote sensing technique which enables high resolution measurement of Earth surface independent of weather conditions and sunlight illumination. KARI has been developing the first Korea SAR satellite which is scheduled to be launched in this year. The SAR satellite mainly consists of the bus platform and SAR payload. Most of all, the RF compatible design during the design phase and the verification of the RF compatibility during the testing phase is very important procedure for the in-orbit performance guarantee because the SAR payload radiates high power through the SAR antenna. In this study, the SAR satellite design criteria and verification procedure for the RF compatibility are described. In addition, this paper describes the RF full radiation testing (RF auto-compatibility testing) for the verification of the RF performance robustness, the testing configuration, and the test results.

Blood Compatibility of Artificial Blood-Contacting Surface Seeded with Cultured Bovine Endothelial Cells (소폐동맥 내피세포를 이용한 인조혈액접촉표면의 혈액 접합성)

  • 김원곤;곽영태;유세영
    • Journal of Chest Surgery
    • /
    • v.26 no.2
    • /
    • pp.80-85
    • /
    • 1993
  • Synthetic and biosynthetic vascular grafts of small diameter have long been considered to be prone to thrombosis, ultimately leading to the complete graft occlusion. Endothelial cell seeding onto synthetic blood-contacting surfaces has been suggested to be an ideal means to solve this problem. This study described a culture method of bovine endothelial cells and evaluated blood-compatibility and seeding efficiency of cultured endothelial cells. Bovine pulmonary artery endothelial cells were harvested enzymatically and grown to confluence on polystyrene culture flask surfaces using established techniques. The identification of endothelial cells was made through the demonstration of expression of factor VIII R:Ag by immunofluorescent technique. To quantitate the effect of improvement in blood-compatibility of viable endothelial cells, endothelial monolayers were exposed to blood containing $\^$111/In-oxine labeled platelets. Viable endothelial monolayers retained less labeled platelets than control surfaces. The Indium-labeled endothelial cells were seeded onto three different blood-contacting surfaces of Dacron vascular graft immobilized in specially equipped wells and incubated for specific time intervals (t=15, 30, 60, 120 minutes). Longer incubation times showed improved cell adherence in collagen-coated and fibrin-coated Dacron vascular graft groups. However in untreated Dacron grafts, no direct relationship was observed between incubation time and endothelial cell seeding efficiency. This may be due to leakage of endothelial cells through porosity of Dacron grafts in this in-vitro experimental condition.

  • PDF

In Vivo Blood Compatibility of PU-PEO-SO3 as Coating Material for Blood Sac of Left Ventricular Assist Device ( LVAD) (좌심실보조장치의 혈액주머니용 코팅재료로서 PU-PEO-SO3의 in vivo 혈액적합성에 관한 연구)

  • 한동근;김종원
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.19-26
    • /
    • 1994
  • Sulfonated poly (ethyleneoxide)-grafted polyurethane (PU-PEO-$SO_3$) prepared by bulk modification was coated on a blood sac for electrohydraulic left ventricular assist device (ELVAD) implanted in dogs and its in vivo blood compatibility on shear stress was studied as compared with untreated Po. The effect of the wall shear stress on the protein adsorption unlike platelet adhesion is dependent on the surface characteristics of the material, although less proteins seem to be adsorbed in the region of the high shear stress. The thickness of total proteins adsorbed on PU-PEO-SOJ (400 ${\AA}$) by trans¬mission electron microscopy(TEM) was considerably lower than that of untreated PU(l,000~1,600 ${\AA}$), but PU-PEO-$SO_3$ showed high albumin adsorption, low fibrinogen and IgG adsorption, and low platelet adhesion as compared with untreated PU, suggesting that PU-PEO-$SO_3$ is more in vivo blood compatible. Therefore, it appears that such a blood compatible PU-PEO-$SO_3$ is useful for blood contacting biomaterials including artificial organs.

  • PDF

Biocompatibilities of Some Synthetic Polymers in Films

  • Kim, Gha-Hee;Yoon, Jin-Hwan;Ree, Moon-Hor;Kim, Hee-Soo
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.257-257
    • /
    • 2006
  • We chose three synthetic polymers, poly(propylene carbonate) (PPC), poly(vinylidene fluoride-co-hexafluoropropylene) (PVFHFP), and $Nafion^{(R)}$ that reveal different chemical and physical characteristics, and investigate their biocompatibilities to five different bacteria (that are most notorious for opportunistic and iatrogenic infections) and a human cell (HEp-2). The bacteria chosen in this study found to adhere onto the PPC and Nafion films but not to adhere on the PVFHFP film. On the other hand, both PVFHFP and Nafion films revealed good compatibility to HEp-2 and allowed the growth of the HEp-2 on the film surface but PPC showed poor compatibility to HEp-2. All results will be discussed with taking into account the surface characteristics of the polymers.

  • PDF

Cell-compatibility of physicochemically and biologically modified polymer surfaces (물리화학적 및 생물학적으로 표면개질된 고분자의 세포 적합성 연구)

  • Lee, J.H.;Park, K.H.;Khang, G.S.;Lee, H.B.;Andrade, J.D.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.1-3
    • /
    • 1989
  • We have treated polymer surfaces such as polyethylene, polystyrene and polyester by various physicochemical and biological surface modification methods to be suitable for cell adhesion. The physicochemical methods we used were $O_2$ plasma discharge, corona discharge, sulfuric acid and chloric acid treatments. For the biological treatments, blood proteins such as plasma protein, serum protein and fibronectin were adsorbed onto the polymer surfaces. Chinese Hamster Ovary (CHO) cells were cultured on the surface-modified polymers and the cell-compatibility of those surfaces were compared. The chloric acid and fibronectin treatments were found to be the best methods of rendering the polymer surfaces adhesive for CHO cells.

  • PDF

Preparation and Characterization of Muscovite Mica/UV Coating Materials for Steel

  • Cheong, In-Woo;Kim, Hyeon-Seok;Hwang, Dong-Seop;Yoo, Hye-Jin;Kim, Jin-Tae;Lee, Jae-Ryung
    • Corrosion Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.265-269
    • /
    • 2010
  • This paper describes the exfoliation and surface modification of muscovite mica for UV coating formulation. For the exfoliation of the mica, hydrothermal process was used in the presence of lithium nitrate ($LiNO_3$). After the cation exchange with $Li^+$ ions, the surface of the mica was modified with several amphiphilic substances to increase compatibility and storage stability in UV coating formulation. Such a hydrophobic surface modification affected colloidal stability as well as dispersibility of the exfoliated mica in UV coating solution. Anticorrosive property of mica/UV coated steel plates was tested by salt spray test (SST) and compared with sodium montmorillonite ($Na^+$-MMT)/UV coated steel plates.

Study on blood compatibility of diamond-like carbon and titanium nitride films (Diamond-like carbon 및 titanium nitride 박막의 혈액적합성 연구)

  • Yun Ju-Young;Bae Jin-Woo;Park Ki-Dong;Goo Hyun-Chul;Park Hyung-Dal;Chung Kwang-Wha
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.3
    • /
    • pp.165-170
    • /
    • 2005
  • There is an increasing interest in developing novel coating to improve the blood compatibility of medical implants. Diamond-like carbon(DLC) and titanium nitride(TiN) films have been proposed as potential biomedical coatings due to their chemical k physical properties and moderate biocompatibility. To study the correlation between blood compatibility and physical properties of the films, the fibrinogen adsorption on the surface as well as morphology & wettability were investigated. The quantity of fibrinogen adsorption are Tower for TiN than DLC, which correlates with a higher hydrophilicity of TiN film. To reduce the quantity of fibrinogen adsorption on the film, plasma treatment and furnace annealing were performed, respectively. With the use of oxygen plasma and furnace annealing, the amount of fibrinogen adsorption on TiN film was remarkably reduced, while there was no decrease of the quantity with DLC.