• Title/Summary/Keyword: Surface Adhesion

Search Result 2,048, Processing Time 0.027 seconds

A STUDY ON THE MARGINAL FIDELITY AND THE FRACTURE STRENGTH OF CEROMERS (수종Ceromer의 변연적합도와 파절강도에 관한 비교연구)

  • Chang Hee-Won;Lee Jong-Hyuk;Lim Heon-Song;Cho In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.438-452
    • /
    • 2005
  • Statement of problem: The use of Ceromer is increasing in dentistry. But, the research of Ceromer has not been conducted much. Purpose : This study was to evaluate the marginal fidelity and internal adaptation according to marginal position. Materials and Methods: In this study 60 resin crowns were fabricated. The measurements of the marginal fidelity were carried out using stereomicroscope $SZ-40^{(R)}$ (Olympus, Japan) and the measurements of fracture strength were done using Instron $8871^{(R)}$ (Instron Co., U.S.A.) at a cross head speed of 1mm/min. All of the measurements were statistically analyzed by ANOVA test, multiple range test and Weibull analysis. Statistical significance was set in advance at the probability level of less than 0.05. All of the measurements were analyzed with Window $SPSS^{(R)}$ Version 10.0 soft ware for the personal computer. Results : 1. There were no statistical differences of the marginal fidelity between $Targis^{(R)}$ and $Tescera^{(R)}$, but difference between these two and $BelleGlass^{(R)}$ according to materials. 2. There were no statistical differences of the marginal fidelity between no fiber group and fiber group. There were no interactions between each maerial and with/without fiber group in the marginal fidelity 3. There were statistical differences of the fracture strength between $Tescera^{(R)}$ and $BelleGlass^{(R)}$ but no statistical differences of the fracture strength between $Targis^{(R)}$ and $Tescera^{(R)}$, $Targis^{(R)}$ and $BelleGlass^{(R)}$ according to materials. 4 There were statistical differences of the fracture strength between no fiber group and fiber group. There were no interactions between each material and with/without fiber group in the fracture strength. 5. When comparing the fracture surface, no fiber group showed the resin which were fractured at the labial surface and separated from the adhesion surface. In fiber group, the fractures took a place in resin compartments. Conclusion. The marginal fidelity and the fracture strength were clinically acceptable. From these results, $Targis^{(R)}$ and $Tescera^{(R)}$ were superior than $BelleGlass^{(R)}$ in the marginal fidelity But, when applying these resin crowns in clinic, more careful consideration is needed and further study is recommended.

Development of Environmental Rubber Interphase Adhesive by use of Oligomer of Hydrocarbon (탄화수소계 올리고머를 이용한 환경친화적 고무계면 접착제 개발)

  • Jang, Byung-Man;Jang, Jeong-Seog;Park, Sung-Soo;Choi, Dug-Jai;Kim, Su-Kyung
    • Polymer(Korea)
    • /
    • v.25 no.1
    • /
    • pp.142-150
    • /
    • 2001
  • Until now rubber industry field has used organic solvent base adhesive, there was always existed a fire risk, variety of quality and harmfulness of human body. To solve this problem we were developed a new adhesive that was maked by raw materials of hydrocarbon series which has the properties of nonvolatile and high flash point. Because of this new adhesive has the properties of nonvolatile and non-harmfulness to the human body, we expected to solve the problems of a fire hazard and the pollution of the environmental. Instead of the rubber binder that is used to a present adhesive, the new idea is adopted in a new type of adhesive. Nonvolatile solvent penetrated to the rubber surface and caused the swelling in rubber surface and as a result of this action, it has the self-adhesive power. In comparision with the present adhesive a new type of adhesive remarkably improved the maintenance time of adhesion and the durability of this adhesive showed similar aspect. Because it did not exhibit a drop of physical properties of rubber which was caused by swelling effect, we estimate that new type adhesive are very stable and not reacted to several rubber additives. While present adhesive appear the crack at cutting surface of curing rubber that caused by gas, new type adhesive not exist these crack.

  • PDF

Formation of Environment Friendly Electrodeposition Films by CO2 Gas Dissolved in Seawater and Their Corrosion Resistance (해수 중 CO2 기체의 유입에 의한 환경 친화적인 전착 코팅막의 형성과 그 내식특성)

  • Lee, Sung-Joon;Kim, Hye-Min;Lee, Seul-Gee;Moon, Kyung-Man;Lee, Myeong-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.1
    • /
    • pp.39-47
    • /
    • 2014
  • The peculiar feature of cathodic protection in seawater has the capability to form mineral calcareous deposits such as magnesium and calcium on metal surfaces. It is assumed that $OH^-$ ions are generated close to the metal surface as a result of cathodic protection and generated $OH^-$ ions increases the pH of the metal/seawater interface outlined as the following formulae. (1) $O_2+2H_2O+4e{\rightarrow}4OH^-$, or (2) $2H_2O+2e{\rightarrow}H_2+2OH^-$. And high pH causes precipitation of $Mg(OH)_2$ and $CaCO_3$ in accordance with the following formulae. (1) $Mg^{2+}+2OH^-{\rightarrow}Mg(OH)_2$, (2) $Ca^{2+}+CO{_3}^{2-}{\rightarrow}CaCO_3$. The focus of this study was to increase the amount of $CO{_3}^{2-}$ with the injection of $CO_2$ gas to the solution for accelerating process of the following formulae. (1) $H_2O+CO_2{\rightarrow}H_2CO_3$, (2) $HCO^{3-}{\rightarrow}{H^+}+CO{_3}^{2-}$. Electrodeposit films were formed by an electro-deposition technique on steel substrates in solutions of both natural seawater and natural seawater dissolved $CO_2$ gas with different current densities, over different time periods. The contents of films were investigated by scanning electron microscopy(SEM) and X-ray diffraction(XRD). The adhesion and corrosion resistance of the coating films were evaluated by anodic polarization. From an experimental result, only $CaCO_3$ were found in solution where injected $CO_2$ gas regardless of current density. In case of injecting the $CO_2$ gas, weight gain of electrodeposits films hugely increased and it had appropriate physical properties.

Chondrogenic Differentiation of Human Mesenchymal Stem Cells on a Patterned Polymer Surface (패턴된 폴리머를 이용한 중간엽줄기세포의 연골 분화)

  • Heo, June Seok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.3
    • /
    • pp.117-124
    • /
    • 2015
  • Mesenchymal stem cells (MSCs) are an attractive tool in tissue engineering as they have the required potential to treat injured articular cartilage. UV-exposed DTOPV (S-triazine bridged p-phenylene vinylene) is a biocompatible and fluorescent polymer with a hydrophilic surface. Previous studies have demonstrated that the surface wettability and hydrophilicity play critical roles in regulating cell adhesion and proliferation. The objective of this study was to improve the potential of in vitro MSC differentiation into Chondrocytes using DTOPV. MSCs were cultured on two different substrates: (1) tissue culture polystyrene (TCPS) as a reference and (2) UV-exposed and patterned DTOPV films. Chondrogenesis of MSCs was induced for two weeks on TCPS and DTOPV in the presence of an induction medium containing transforming growth factor (TGF)-${\beta}3$. Interestingly, the MSCs on TCPS adhered and spread, while those on DTOPV tended to form aggregates within several days. The cells cultured on DTOPV for two weeks had a round morphology, with stronger Safranine O staining of the extracellular matrix than that of the cells cultured on TCPS. Also, Type II collagen gene was significantly expressed in cells induced on DTOPV. These results indicate that chondrogenic differentiation of MSCs proceeds more rapidly on DTOPV than on TCPS. Therefore, in cartilage tissue engineering, DTOPV could be used to induce effective chondrogenic differentiation of MSCs.

EFFECT OF DENTURE BASE SURFACE PRETREATMENTS ON THE TENSILE BOND STRENGTH BETWEEN A RESILIENT LINER AND A PROCESSED DENTURE BASE RESIN (의치상 레진의 표면 전처리가 연성 이장재와의 인장결합강도에 미치는 영향)

  • Yoon, Min-Chul;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.621-632
    • /
    • 2007
  • Statement of problem: The failure of adhesion between the resilient denture liner and the denture base is a serious problem in clinic. Purpose: The purpose of this study was to evaluate the effect of denture base resin surface pretreatments (mechanical and/or chemical) on the tensile bond strength between a resilient liner and processed denture resin. Material and method. Acrylic-based resilient liners (Soft liner; GC co., Japan & Coe-Soft; GC America Inc. USA) and silicone-based resilient liners (Mucosoft, Parkell Inc., USA & Dentusil; Bosworth co., USA) were used. Specimens in each soft lining material were divided two groups with or without mechanical pretreatment. Each denture base specimen received 1 of 4 chemical pretreatments including: (1) no treatment, (2) 30-s acetone treatment, (3) 15-s methylene chloride treatment, (4) 180-s methyl methacrylate treatment. All specimens were thermocycled and placed under tension until failure in a universal testing machine. Results: 1. Silicone-based resilient liners exhibited significantly higher tensile bond strengths than acrylic-based resilient liners (P<.05). 2. Grinding the denture base resin improved tensile bond strengths of silicone-based resilient liners, but reduced tensile bond strengths of acrylic-based resilient liners (P<.05). 3. In acrylic-based resilient liners, treating with acetone significantly increased the bond strength of Soft liner and treating with methyl methacrylate significantly increased the bond strength of Coe-Soft (P<.05). However they were not effective compared to silicone-based resilient liner. 4. In silicone-based resilient liners, treating with all chemical etchants significantly increased the bond strength of Mucosoft to denture base, and treating with methylene chloride and methyl methacrylate increased the bond strength of Dentusil to denture base (P<.05). Conclusion: Although chemical and mechanical pretreatments were not effective on tensile bond strength of acrylic-based resilent liner to denture base, treating the denture base resin surface with appropriate chemical etchants after mechanical pretreatment significantly increased the tensile bond strength of silicone-based resilient liner to denture base.

Effect of Electropolishing on Surface Quality of Stamped Leadframe (Stamped Leadframe의 표면 품질에 미치는 전해연마 효과)

  • 남형곤;박진구
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.3
    • /
    • pp.45-54
    • /
    • 2000
  • The effect of electropolishing far stamped leadframe on the removal of the edge burr and residual stress relief was examined. The present study showed that the electropolishing could be used for enhanced surface quality of stamped leadframes. The electropolishing was performed at the condition of 60% phosphoric acid electrolyte, 5 ampere of current and 3 cm electrode gap at $70^{\circ}C$ for 2 minutes for Alloy42 type leadframe, and $50^{\circ}C$ for 1.5 minutes for C-194 type leadframe. The FWHM values from X-ray diffraction showed that residual stress of electropolished leadframe recovered to the level of as-received raw materials and surface roughness measured by using AFM tuned out to be improved by 0.079 $\mu\textrm{m}$ and 0.014 $\mu\textrm{m}$ ($R_{rms}$) far alloy 42 and C-194 type leadframes, respectively. The plated thickness using XRF showed the improved uniformity in thickness variation by 0.4~0.5 $\mu\textrm{m}$ and grain growth, which is favorable for interface adhesion, was also observed from the bake test samples. We could certify dimensional stability of leadframe with inspection by means of 3D-topography and hardness measurements.

  • PDF

Characteristic of Pd-Cu-Ni Alloy Hydrogen Membrane using the Cu Reflow (Cu Reflow를 이용한 Pd-Cu-Ni 합금 수소분리막 특성)

  • Kim, Dong-Won;Kim, Heung-Gu;Um, Ki-Youn;Kim, Sang-Ho;Lee, In-Seon;Park, Jong-Su;Ryi, Shin-Kun
    • Korean Chemical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.160-165
    • /
    • 2006
  • A Pd-Cu-Ni alloyed hydrogen membrane has fabricated on porous nickel support formed by nickel powder. Porous nickel support made by sintering shows a strong resistance to hydrogen embrittlement and thermal fatigue. Plasma surface modification treatment is introduced as pre-treatment process instead of conventional HCl wet activation. Nickel was electroplated to a thickness of $2{\mu}m$ in order in to fill micropores at the nickel support surface. Palladium and copper were deposited at thicknesses of $4{\mu}m$ and $0.5{\mu}m$, respectively, on the nickel coated support by DC sputtering process. Subsequently, copper reflow at $700^{\circ}C$ was performed for an hour in $H_2$ ambient. And, as a result PdCu-Ni composite membrane has a pinhole-free and extremely dense microstructure, having a good adhesion to the porous nickel support and infinite hydrogen selectivity in $H_2/N_2$ mixtures.

A Study on the Surface-Modification of Barium Sulfate/TiO$_2$/Dimethicone Composite Powder and its Application in Color Cosmetics (바륨설페이트/티타늄디옥사이드/디메치콘의 복합화 및 메이크업에서의 응용)

  • Kyung-Ho, Choi;Seung-Yong, Ko;Hak-Hee, Kang;Ok-Sub, Lee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.197-200
    • /
    • 2004
  • Sensor and optical properties have become critical features in powder foundation. The flaky barium sulfate powder shows good smooth texture, adhesion and natural looking characteristics. However, it has limitations abilities in UV shielding, hiding and blooming effect. Thus we adopt TiO$_2$ that has excellent hiding power and blooming effect as well as UV shielding ability, but TiO$_2$ has still intrinsic problems in dispersion and texture. To overcome this disadvantages, the barium sulfate/TiO$_2$/dimethicone composite powder was prepared. The flaky barium sulfate powder was coated with TiO$_2$ in nanoscale and followed by coated with dimethicone. When this surface-modified powder was applied for make-up cosmetics, especially in powder foundation, the powder gave powder foundation more good characteristics than the original flaky barium sulfate, Ti02 powder, dimethicone in abovementioned optical and sensory properties. To characterize the distinctive features of this surface-modified powder, we measured its characteristics with UV in vitro tester, hiding powder test method, goniophotometer, consumer panel test and so on.

Optimization of fabrication and process conditions for highly uniform and durable cobalt oxide electrodes for anion exchange membrane water electrolysis (음이온 교환막 수전해 적용을 위한 고균일 고내구 코발트 산화물 전극의 제조 및 공정 조건 최적화)

  • Hoseok Lee;Shin-Woo Myeong;Jun-young Park;Eon-ju Park;Sungjun Heo;Nam-In Kim;Jae-hun Lee;Jae-hun Lee;Jae-Yeop Jeong;Song Jin;Jooyoung Lee;Sang Ho Lee;Chiho Kim;Sung Mook Choi
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.6
    • /
    • pp.412-419
    • /
    • 2023
  • Anion exchange membrane electrolysis is considered a promising next-generation hydrogen production technology that can produce low-cost, clean hydrogen. However, anion exchange membrane electrolysis technology is in its early stages of development and requires intensive research on electrodes, which are a key component of the catalyst-system interface. In this study, we optimized the pressure conditions of the hot-pressing process to manufacture cobalt oxide electrodes for the development of a high uniformity and high adhesion electrode production process for the oxygen evolution reaction. As the pressure increased, the reduction of pores within the electrode and increased densification of catalytic particles led to the formation of a uniform electrode surface. The cobalt oxide electrode optimized for pressure conditions exhibited improved catalytic activity and durability. The optimized electrode was used as the anode in an AEMWE single cell, exhibiting a current density of 1.53 A cm-2 at a cell voltage of 1.85 V. In a durability test conducted for 100 h at a constant current density of 500 mA cm-2, it demonstrated excellent durability with a low degradation rate of 15.9 mV kh-1, maintaining 99% of its initial performance.

Analysis of Stromal Cells Developed from Cord Blood CD34+ Cells (제대혈 CD34+ 세포에서 유래된 지지세포의 분석)

  • Ryu, Kyung-Ha;Park, Se-Jin;Kim, Kyung Hyo;Seoh, Ju-Young;Khan, Mohammad;Shin, Hee-Young;Ahn, Hyo-Seop
    • IMMUNE NETWORK
    • /
    • v.1 no.1
    • /
    • pp.87-94
    • /
    • 2001
  • Background: Cytokine-mediated ex vivo expansion has been proposed as a means of increasing the number of cord blood (CB) hematopoietic stem cells for transplantation. As well as stem cell number, stromal cells are necessary for functional maturation of hematopoiesis. The purpose of this study was to analyze the development of stromal cells during ex vivo expansion of CB $CD34^+$ cells. Methods : $CD34^+$ cells were purified from CB by magnetic bead selection. The levels of of interleukin-3, interleukin-$1{\beta}$, interleukin-6, granulocyte macrophagecolony stimulating factor and tumor necrosis factor-${\alpha}$ were measured in culture supernatants on 0, 1, 2, and 3 weeks, using ELISA techniques. CB $CD34^+$ cells were expanded in Iscoves modified Dulbeccos medium in the presence of several cytokines. The expression of E-selectin, vascular cell adhesion molecule-1, intercellular adhesion molecule-1, platelet/endothelial cell adhesion molecule-1, von Willebrand factor, vimentin, and CD14 in newly developed stromal cells was examined by immunocytochemical method. Relevant extracellular matrix (ECM) proteins and proper cytokines were also assayed for the most suitable condition for expansion of stromal cells. Results: Several cytokines were found to have been produced by CB $CD34^+$ cells as well as bone marrow-derived $CD34^+$ cells. During ex vivo expansion of CB $CD34^+$ cells, stromal cells appeared in the culture by day 4 and expanded over the following 7-10 days before being confluent by day 2 1. These cells expressed surface markers characteristic of cells of endothelial lineage. Furthermore, these stroaml cells also expanded effectively when treated with thrombopoietin+flt-3 ligand+stem cell factor+leukemia inhibitory factor or 0.1% poly-L-lysine-coated wells. Conclusion: Stromal cells were developed during ex vivo expansion of CB $CD34^+$ cells and that this development could be enhanced further by treating the stromal cells with cytokines or ECM.

  • PDF