• Title/Summary/Keyword: Support Device

Search Result 1,021, Processing Time 0.024 seconds

A Smart Sensor Device Management System in Nano-Q+ (Nano-Q+에서 스마트 센서 디바이스 관리 시스템)

  • Kim, Bum-Suk;So, Sun-Sup;Kim, Byeong-Ho;Eun, Seong-Bae
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.1
    • /
    • pp.31-39
    • /
    • 2008
  • Sensor Node OS should support unified API and efficient sensor device management system to overcome the diversity of sensors and actuators. However, conventional OSs like Tiny-OS and Nano-Q+ do not. In this paper, we propose a sensor device driver management system that present application programmers with unified API and easy deployment of sensors. When a sensor is deployed in our device management system, the device driver is downloaded. This scheme differs from traditional OS like SOS in that only sensor device driver is downloaded, not the whole application image. We designed and implemented the system into Nano-Q+. We described the comparison with other OSs and showed that our system obtains the considerable speedup of downloading.

Development of Non-Contact Penetration Measuring Device for Pile Driving Workers (항타 시공 작업자를 위한 비접촉식 관입량 측정기 개발)

  • Kim, J.K.;Kong, Y.K.;Choi, K.H.;Cho, M.U.;Kim, S.Y.;Kim, M.J.;Lee, J.H.;Park, Chae Won
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.58-63
    • /
    • 2020
  • At the construction site of the driving site, the pile rebound and penetration measurements are performed manually to determine the end point of the driving operation, thereby causing the measurer to be exposed to a death accident. In this study, in order to eliminate the risk of this work, a non-contact penetration measuring device was developed and usability evaluation was conducted. The penetration measuring device is manufactured based on the ultrasonic sensor, and can be combined with the pile to deliver the data in real time, and the delivered data can be output in real time on the portable PC and the final penetration can be calculated. Usability evaluation on the device was conducted by comparison with manual work. Usability evaluation was largely evaluated on measured values, subjective comfort, and body parts comfort. The result of the measured value tended to overestimate the value measured manually by the measuring device, which is similar to the previous research. In terms of subjective comfort and body part comfort, overall satisfaction was higher than the manual method when using the measuring device. Taken together, these results indicate that it is possible to use the rudder measuring device in place of manual work in the construction site, and it is judged that the worker's comfort is greatly increased by using the measuring machine. The results of this study suggest that the use of non-contact measuring device in the field can be used as basic data to support them.

Development and usability test of transfer device with customized sling lifts

  • SeYeon Jeong;KiHun Cho;SoungKyun Hong;WonJae Choi;Kwangkook Lee;Kyeongbong Lee;GyuChang Lee
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.4
    • /
    • pp.9-16
    • /
    • 2023
  • Background: Bedridden patients and disabled persons need help from a guardian or caregiver even in performing simple activities of daily living. In particular, for body transfer of them, the use of a transfer lift has been recommended. However, the devices currently in use have limitations in terms of support according to the individual's characteristics. This study aimed to develop a transfer lift device utilizing the patients' body-fitting sling equipped with an air tube inside the sling. In addition, we have conducted usability tests to examine the safety, effectiveness, and satisfaction with this device. Design: This study conducted usability tests with 10 healthy adults. Methods: Customized sling lifts are generally floor-based devices that consisted of a sling that holds the patient's body and a lift that moves the sling to the desired position. One characteristic feature of the device is an air tube, which is used on the sling to allow the patient's body can be adjusted. A usability test was performed in terms of the operators, who operated the device to transfer the patients. Ten operators tried the device and tested its usability. Results: The mean of 10 question for Questions was 4.18. Conclusion: The device can be useful in the advance- ment and commercialization of customized sling lifts, to ensure the safe and efficient transfer of persons with disabilities.

Development of a Digital Otoscope-Stethoscope Healthcare Platform for Telemedicine (비대면 원격진단을 위한 디지털 검이경 청진기 헬스케어 플랫폼 개발)

  • Su Young Choi;Hak Yi;Chanyong Park;Subin Joo;Ohwon Kwon;Dongkyu Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.3
    • /
    • pp.109-117
    • /
    • 2024
  • We developed a device that integrates digital otoscope and stethoscope for telemedicine. The integrated device was utilized for the collection of tympanic membrane images and cardiac auscultation data. Data accumulated on the platform server can support real-time diagnosis of heart and eardrum diseases using artificial intelligence. Public data from Kaggle were used for deep learning. After comparing with various deep learning models, the MobileNetV2 model showed superior performance in analyzing tympanic membrane data, and the VGG16 model excelled in analyzing cardiac data. The classification algorithm achieved an accuracy of 89.9% for eardrums data and 100% for heart sound data. These results demonstrate the possibility of diagnosing diseases without the limitations of time and space by using this platform.

Design and Implementation of Bus for 32-bit RISC Microprocessor (32-bit RISC마이크로프로세서를 위한 버스 설계 및 구현)

  • 양동훈;곽승호;이문기
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.333-336
    • /
    • 2002
  • This paper purpose design and implementation of system bus for the effective interconnection between peripheral device and 32-bit microprocessor. The designed system bus support general bus protocol. Also, it is optimized for 32-bit microprocessor. It is divided into two system. high performance system bus and Peripheral system bus.

  • PDF

Influence of Longitudinal Arch of Foot on the Strength and Muscle Activity of the Abductor Hallucis in Subjects with and without Navicular Drop Sign

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.4
    • /
    • pp.222-227
    • /
    • 2019
  • Purpose: This study examined the influence of longitudinal arch on the strength and muscle activity of the abductor hallucis in the standing position in subjects with and without navicular drop signs. Methods: A sample of 34 subjects with and without navicular drop signs between 22 and 28 years of age were enrolled in this study. The strength and muscle activity of the abductor hallucis was measured using a tensiometer. The Smart KEMA System and electromyography device was used on the subjects with and without navicular drop signs. Two groups were classified using the navicular drop test to identify the longitudinal arch of the foot. The strength of the abductor hallucis was evaluated in standing, both with and without an external arch support condition. The two-way mixed ANOVA was used. The level of statistical significance was set to ${\alpha}=0.05$. Results: The strength and muscle activity of the abductor hallucis in standing was significantly higher with external arch support than that without the external arch support in the group with navicular drop signs. There was no significant difference in the abductor hallucis strength and muscle activity with and without external arch support in the subjects without navicular drop signs. Conclusions: The strength and muscle activity of the abductor hallucis in standing can be influenced by the external arch support in the group with navicular drop signs. The strength measurement of the abductor hallucis in standing should be separately performed in conditions with and without longitudinal arch of foot.

Sense Hardware Backup Algorism of 3D Game Engine

  • Aamisepp, Henrik;Nilsson, Daniel
    • 한국정보컨버전스학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.125-128
    • /
    • 2008
  • The aim this master thesis is to find out if is possible to Integrate haptic hardware support in the source 3D game engine Crystal Space. Integrating haptic support would make it possible to get a haptic representation of 3D geometry in Crystal Space and therefore take advantage of all the benefits a 3D game engine provides, when building haptic applications, An implementation of the support should be as low-cost as Possible by taking advantage of available source haptic API alternatives. The thesis report presents an evaluation of available haptic APIs and comes up with a design and an implementation. The solution has been implemented as a Crystal Space plugin by using modified parts of the e-Touch open module API. The plugin makes it possible to utilize the Phantom haptic device to touch and feel the 3D environments in a Crystal Space application. Two demo applications have also been constructed to show the capabilities of the plugin.

  • PDF

Catalyst Enhanced by Controlling Structure and Shape of Nanocrystals, Support Materials, and Hybrid System in DMFCs (나노입자의 구조와 모양, 담지체 및 하이브리드 시스템 제어를 통한 직접메탄올 연료전지의 촉매 개발)

  • Lee, Young Wook;Shin, Tae Ho
    • Ceramist
    • /
    • v.22 no.2
    • /
    • pp.189-197
    • /
    • 2019
  • Direct methanol fuel cells (DMFCs) have found a wide variety of commercial applications such as portable computer and mobile phone. In a fuel cell, the catalysts have an important role and durability and efficiency are determined by the ability of the catalyst. The activity of the catalyst is determined by the structure and shape control of the nanoparticles and the dispersion of the nanoparticles and application system. The surface energy of nanoparticles determines the activity by shape control and the nanostructure is determined by the ratio of bi- and tri-metals in the alloy and core-shell. The dispersion of nanoparticles depends on the type of support such as carbon, graphen and metal oxide. In addition, a hybrid system using both optical and electrochemical device has been developed recently.

Change in Exposure Concentration in the Cleaning Process after Installing a Local Exhaust System (디클로로메탄 사용 세척공정의 국소배기장치 설치 후 노출농도 변화)

  • Myung Hwa Cho;Seung gi Kim;Hyun Soo Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.3
    • /
    • pp.280-283
    • /
    • 2023
  • Objectives: The purpose of this study was to examine the change in exposure concentration in the cleaning process after installing a local exhaust system. Methods: Dichloromethane measurement was conducted according to the KOSHA Guide (A-19-2019). Results: After the local exhaust device was installed, a total of three measurements were conducted, including temporary work environment measurements, and all of the measurements did not exceed the DCM exposure standard, but were more than 50% of the DCM Time Weighted Average((8-TWA) Conclusions: It is thought that the local ventilation system of a small business needs not only support for the initial installation cost, but also educational support for maintaining the performance of the local ventilation system and support for consumables (adsorbents, filters, etc.) that incur periodic costs.

Secret Information Protection Scheme for Device in Home Network (홈 네트워크에서 디바이스를 위한 비밀 정보 보호 기법)

  • Maeng, Young-Jae;Kang, Jeon-Il;Mohaisen, Abedelaziz;Lee, Kyung-Hee;Nyang, Dae-Hun
    • The KIPS Transactions:PartC
    • /
    • v.14C no.4
    • /
    • pp.341-348
    • /
    • 2007
  • Even though the secret information stored in home device in home network must be handled very safely and carefully, we have no measure for protecting the secret information without additional hardware support. Since already many home devices without consideration of the security have been used, the security protection method for those devices have to be required. In this paper, we suggest two schemes that protect the security information using networking function without additional hardware support, and those hybrid method to supplement the defects of each scheme. We also consider the our proposals in the aspects of security and cost.