• 제목/요약/키워드: Supply water

검색결과 3,493건 처리시간 0.032초

수돗물 위해요소 리스크 관리를 위한 물안전계획 적용 연구 (A study on the application of water safety plans for the hazard risk management of tap water)

  • 김진근;김두일
    • 상하수도학회지
    • /
    • 제33권4호
    • /
    • pp.259-268
    • /
    • 2019
  • One of the most effective methods to consistently ensure the safety of a tap water supply can be achieved by application of a comprehensive risk assessment and risk management approach for drinking water supply systems. This approach can be termed water safety plans(WSP) which recommended by WHO(world health organization) and IWA(international water association). For the introduction of WSP into Korea, 150 hazards were identified all steps in drinking water supply from catchment to consumer and risk assessment tool based on frequency and consequence of hazards were developed. Then, developed risk assessment tool by this research was implemented at a water treatment plant($Q=25,000m^3/d$) to verify its applicability, and several amendments were recommended; classification of water source should be changed from groundwater to stream to strengthen water quality monitoring contaminants and frequencies; installation of aquarium to monitor intrusion of toxic substances into raw water; relocation or new installation on-line water quality analyzers for efficient water quality monitoring; change of chlorination chemical from solid phase($Ca(OCl)_2$) to liquid phase(NaOCl) to improve soundness of chlorination. It was also meaningful to propose hazards and risk assessment tool appropriate for Korea drinking water supply systems through this research which has been inconsistent among water treatment authorities.

농촌지역 간이상수도시설 개발 및 개선에 관한 연구 (A Study on the Development and Improvement of Simple Piped Water Supply System in Rural Area of Korea)

  • 정용;구자건;김명호;윤석우;김인숙
    • 농촌의학ㆍ지역보건
    • /
    • 제13권1호
    • /
    • pp.19-25
    • /
    • 1988
  • It is very important to supply safe drinking water for rural area not only a prevention of entric diseases but also a promotion of health life. It is estimated that 6,981,000 rural inhabitants were covered by the simple piped water supply system at the end of 1987 in Korea. The programme for improvement of water supply system in rural villages was initiated by the government since 1967. But most of these systems have been operated carelessly by the hands of villagers who have no proper knowledge and experience. Since most of water sources were located nearby farmland, there might be a possibility that the sources could be contaminated by pesticides and fertilizers. For this reason, it is recommended to take underground water as a water source rather than surface water such as a pond or streamwater in rural areas. However, the system is supplied from the surface water, its water quality can be improved by using of simple sand filter and simple chlorinator inexpensively. On the basis of an on-site study, conducted during 1986-87, in San-Buk Village, Keum-Sa-Myon, Yeju-Gun, Kyong-Gi-Do, the new simple piped water supply system was designed by the Institute for Environmental Research, Yonsei University, and constructed by the villagers themselves in September 1987. This simple system which is protected by metal fences consists of three main parts, pump house, vertical sand filter and water tank. The pumped water from underground flows into the upper part of the sand filter, through the sand, and out the water tank which is connected to the bottom of vertical filter. And the simple plastic-bottle chlorinator was installed in the water tank for chlorination. The water quality was remarkably improved after completion of construction. The total bacterial count was not detected from the tap water in households distributed by this simple piped water supply system. The construction cost of this system which was connected 34 households in San-Buk Village, was 4,851,000 won (approximately 6,020 U.S. dollars : 1$=805.8 won) in 1987,77% of expenses was supported by the Community Development Foundation in Korea. This case study for simple piped water supply projects will be applicable to other programme for improvement of water supply system in rural areas of Korea, and other developing countries.

  • PDF

마닐라 광역시 물공급 이슈(Issues) 진단 (The Assessment of Water Supply Issues in Metro Manila)

  • ;김이형;정상만
    • 한국습지학회지
    • /
    • 제10권3호
    • /
    • pp.37-45
    • /
    • 2008
  • The Philippine government enacted the National Water Crisis Act in 1995, as a response to the burgeoning situation of water supply systems in the country. This act led to the privatization of Metropolitan Waterworks and Sewerage System (MWSS), sector having jurisdiction and control over all waterworks and sewerage systems in a service area including Metro Manila. Nowadays, the region's supply of water is still facing a lot of difficulties, both in quality and quantity. The unabated migration of people to the metro which increases its population, tapping from the aged pipelines, lack of water facilities and infrastructure, excessive groundwater withdrawal, environmental degradation, and surface and groundwater pollution are some of the issues that Metro Manila have to deal with. These situations lead to two primary water supply issues suffered by Metro Manila: water shortage and flooding. The purpose of this paper was to present water supply in Metro Manila with respect to the problems in its distribution, environmental implications and quality. In this paper, several technical reports, published literature, and news articles were consulted and became the major basis for identifying gaps and suggesting remedial measures.

  • PDF

상·하수 배관재의 수 환경에서 부식진전도 연구 (Research of Corrosion Growth Degree According in Liquid Environment of Waterworks and Sewer Piping Material)

  • 박경동;기우태;유형주;김동욱
    • 한국기계가공학회지
    • /
    • 제5권4호
    • /
    • pp.33-40
    • /
    • 2006
  • The quality of the supply water which is supplied to consumer is not the thing of water after filtrating but the thing of water from faucet through pipe. As a result, heavy metals and microorganism, that is the major materials, which cause the distrust of the supply water is generated by supply process. Especially, the heavy metal is generated by the corrosion of waterworks. Besides, rupture by corrosion of pipe becomes the factor of supply water's pollution in waterworks and the factor of pollution of the soil and environment in drain pipe. Therefore, this research examined the weight reduction electric potential measure to measure the corrosion degree of piping materials after testing the corrosion of piping materials(Copper Pipe, Galvanized Steel Pipe, Stainless Steel Pipe) which is generally used at the moment in various corrosion environments(subterranean water, supply water, 3.5% NaCl, 3.5% $HNO_3$). And let me show basic design data about problem occurrence such as leakage water, rust water, inside and outside corrosion from this.

  • PDF

BYG형 급수기의 MINI PC 제어 시스템 (Mini PC control system for BYG type water supply units)

  • 박용규;강영모
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.1167-1171
    • /
    • 1993
  • A highly efficient hydropneumatic water supply system type BGY is designed and built in accordance with ISO standard. The technical features of BYG type pump unit can be summarized as follows: - reduce hydropneumatic tank capacity at the ratio of 1/10 - 1/30 compared with conventional method. - ISO standard pumps can be used. - the development of highly efficient water supply system type BYG is based on long-term experiences with the proven constant pressure water supply technique which minimize pressure fluctuation, rapid pilsation, etc. The text contains the operation principle of BYG type water supply system, introduction of closed cycle control process focused on Mini PC and experimental results of type BYG-IVS-90x45.

  • PDF

수력발전소 물 공급 설비에 대한 FTA 모형 (FTA Modeling of Water Supply System for Hydro-power Plant)

  • 전태보;권창섭
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.145-155
    • /
    • 2006
  • High level of reliability in facility operation is specifically required these days. The goal of this study is to secure a methodology for reliability analysis of hydro-power plant so that an appropriate decision for operation and investment can be made. Fault tree analysis of water supply system within hydro-power plant has been performed in this study. We briefly examined the electric power generation facility and water supply system. We then developed fault tree for the water supply system based on failure modes and effects analysis. We conclude this study and provided future research areas.

  • PDF

본포취수장 태양광발전설비의 효과적 운영방법에 관한 연구 (A Study on the Effective Operation of Bonpo Photovoltaic Power System)

  • 조남빈;이재오;최장건;이재훈;최연한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1124-1125
    • /
    • 2008
  • 본 연구는 한국수자원공사에서 국제기후변화협약 등 정부의 신재생에너지 개발계획에 적극 동참하고, 우리공사에서 운영관리하고 있는 수자원시설물의 잠재에너지를 발굴하기 위하여 경남지역본부 본포취수장에 설치하여 운영관리중인 시설용량 99kWp의 태양광발전설비에 대한 주요 설비와 운영관리를 하는데 불편한 사항에 대한 개선내용을 소개함으로써 향후 우리시스템과 유사한 조건(무인사업장)에 시설하여 운영할 설비를 효과적으로 관리하기 위한 내용을 소개하고 있다.

  • PDF

농촌마을종합개발사업에서 상하수도시설의 합리적 계획방향에 관한 기초적 연구 (A Study on the Rational Planning of Water Supply and Sewage System for Rural Village Development Projects)

  • 김환용
    • 한국농촌건축학회논문집
    • /
    • 제8권2호
    • /
    • pp.62-71
    • /
    • 2006
  • This study on the rational planning of water supply and sewage system for rural village development projects. Present, when establishment and standard about maintenance of water supply and sewage system were not presented in rural village synthesis development projects, it is real condition that service industry is depending on presenting simple plan in basis planning phase and business enforcement step. This study wishes to present basic data so that can be planned more rationally and enforce and contribute in rural village synthesis development projects water supply and sewage system that is enforced as part of rural village synthesis development projects.

  • PDF

바닥복사 난방시스템의 공급온수온도가 실내 열환경에 미치는 영향 (The Effects of Hot Water Supply Temperature on Indoor Thermal Characteristics for Floor Radiant Heating System)

  • 안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.13-19
    • /
    • 2018
  • The Effects of hot water supply temperature on indoor thermal characteristics for floor radiant heating system in residential apartment were researched by computer simulation. The parametric study on hot water supply temperatures with different outdoor air temperatures was done with regard to energy performance and control characteristics, respectively. As a result, the maximum overshoot of indoor air temperature and energy consumption were reduced by adjusting the hot water supply temperatures with outdoor air temperatures.

부족분 공급방식의 한강수계 저수지 시스템 용수공급능력 평가 (Water Yield Evaluation of a Reservoir System Based on a Deficit Supply in the Han River Basin)

  • 최영제;이은경;지정원;이재응
    • 대한토목학회논문집
    • /
    • 제40권5호
    • /
    • pp.477-484
    • /
    • 2020
  • 우리나라의 용수공급은 대부분 저수지 운영에 의존하고 있어 저수지 운영은 안정적인 용수공급에 직접적인 영향을 미치게 된다. 하지만 최근 강우의 시공간적 변동성이 증가함에 따라 심도 깊은 가뭄의 발생이 잦아지고 있으며 동일 유역 내에서도 강우의 공간적 편차가 커지고 있다. 이러한 기후의 변화는 하류 지점의 안정적인 유량을 유지하기 위한 저수지 시스템의 운영에도 어려움을 증가시키고 있다. 본 연구에서는 이러한 문제를 해결하기 위한 방안으로 부족분 공급방식의 저수지 운영을 적용하여 저수지 시스템의 용수공급능력을 평가하고자 하였다. 이를 위해 한강유역에 위치한 9개 댐을 대상으로 저수지 모의운영을 실시하고, 분석결과의 평가지표로는 기간신뢰도, 양적신뢰도, 회복도 등을 활용하였다. 저수지 모의운영 모형은 일정량 공급방식 적용, 부족분 공급방식 적용, 부족분 공급 및 화천댐 실측방류량 적용 케이스 등 총 3개 케이스의 모형을 구축하였다. 그 결과 부족분 공급방식을 적용하였을 때 신뢰도와 회복도 등 모든 지표에서 저수지 시스템의 용수공급능력이 증가하는 것으로 분석되었다. 특히 기간신뢰도는 30 % 이상 증가하고 양적신뢰도는 약 4 % 증가하는 효과를 거둘 수 있는 것으로 분석되었다. 따라서 수계 내의 모든 저수지가 각각 부여받은 용수공급량 충족이라는 목적과 동시에 하류 동일 지점의 안정적 유량유지를 목적으로 운영될 경우 수계전체의 용수공급능력 증대라는 효과를 얻을 수 있는 것으로 판단되었다. 또한 본 연구를 통해 부족분 공급방식의 저수지 운영이 강우의 공간적 변동성 증가와 같은 기후변화에 대응 가능한 효율적인 저수지 운영방안임을 확인할 수 있었다.