• 제목/요약/키워드: Supply and exhaust port

검색결과 17건 처리시간 0.022초

열원이 있는 밀폐된 선박 기관실에서의 난류기류에 관한 수치적 연구 (Numerical simulation of turbulent air-flow in a closed engine room with heat source in a ship)

  • 박찬수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권1호
    • /
    • pp.100-107
    • /
    • 1998
  • Ventilation of the marine engine room is very important for the health of the workers as well as the nomal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-.epsilon. model was carried out. In the present study, the marine engine room is considered as a closed space with a heat source and forced ventilation ducts. The injection angle of air supply is found to be important. Injection with downword angle depresses recirculation flow, causing a strong steam in the wider space of the room. Ventilation and removal of the released heat are promoted with this pattern. There is a possibility of local extreme heating at the upper surface of engine when supply and exhaust ports of air are in bilateral symmetry. The effect of the increase of exhaust port area on ventilation decreases as the number of supply port increases.

  • PDF

도로터널 반횡류환기시스템에서 급배기 포트개도 및 화재시 운영방안에 관한 수치해석적 연구 (Numerical Study on the Supply and Exhaust Port Size and Fire Management Method in the Semi-transverse Ventilation System for Road Tunnel)

  • 유지오;김진수;이동호
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.68-74
    • /
    • 2016
  • 도로터널에 적용하는 반횡류환기방식은 터널의 전연장에 걸쳐서 단위길이당 풍량이 균일하게 될 수 있도록 포트의 개도 조정이 필수적이다. 그러나 현재 국내에서 운영중인 터널의 경우에는 설계시 이에 대한 고려가 적절히 이루어지지 못하고 있는 실정이다. 이에 본 연구에서는 개도계산을 위한 프로그램을 개발하고 반횡류환기방식의 터널에서 포트의 운영방안을 제시하였다. 연구결과, 포트의 개도는 급기방식의 덕트에서는 환기소측에서 덕트의 말단(bulk head)쪽으로 갈수록 증가하였다가 감소하는 경향을 가지며, 최소 개도는 56% 정도로 나타나고 있다. 또한 배기방식에서는 환기소측이 15% 정도로 가장 작고 bulk head 쪽으로 갈수록 증가하는 경향을 보이고 있다. 화재시 300 m 구간의 배연풍량을 검토한 결과, 포트사이즈를 조정하지 않는 경우와 급기방식으로 포트사이즈을 조정한 경우에는 터널중앙부의 배연량이 각각 8.1%와 12.5%로 터널중앙부의 배연풍량이 저조한 것으로 나타났다. 따라서 반횡류환기방식의 터널에서는 평상시 환기효율이 저하하더라도 배연시 균일한 풍량을 얻을 수 있도록 포트의 개도를 설정하여 운영하는 것이 반드시 필요한 것으로 판단된다.

횡류식 도로터널의 급, 배기구 포트 개구면적 최적화 프로그램 개발 연구 (A study on the program development for area optimizing of damper ports in road tunnels with transverse ventilation system)

  • 조형제;전규명;민대기;김종원;백종훈
    • 한국터널지하공간학회 논문집
    • /
    • 제21권1호
    • /
    • pp.177-188
    • /
    • 2019
  • 횡류식 환기 시스템이 설치된 터널에서 급, 배기구 포트 개구면적의 최적화는 외부로부터 터널 내에 급기되는 신선공기의 분배를 균일하게 하고 터널 내 오염물질을 효율적으로 배출하여 터널 이용자에게 안전하고 쾌적한 터널 환경을 제공하기 위한 것이다. 이를 위하여 횡류 환기방식이 적용된 대심도 복층터널 내부에 균일한 급기 또는 배기풍량을 얻기 위해서 급, 배기구 포트 면적계산 및 최적화하기 위한 프로그램이 개발되었다. 개발된 포트 면적 계산 및 최적화 프로그램의 신뢰성 확보를 위해 현재 운영 중인 반횡류 환기방식을 적용하고 있는 터널의 덕트 내 풍속을 측정하였다. 또한 동일한 터널에 대한 3차원 수치해석을 수행하였고 CFD 결과를 측정된 값과 비교하였다. 분석결과, 프로그램이 예측한 값과 현장측정결과의 오차율은 약 6.72%를 보이고 있으며, 3차원 수치해석 결과와의 오차율은 약 4.86%로 나타났다. 두 결과 모두 10% 이내의 오차율을 보이고 있으므로, 이 포트 개구면적 최적화 프로그램을 사용해서 횡류식 터널의 급기 및 배기 포트의 최적화 설계가 가능할 것으로 기대된다.

실내 공기질 개선을 위한 환기기술에 관한 연구 (A Study on the ventilation Technology for Indoor Air Quality Improvement)

  • 장태현;조현욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.540-551
    • /
    • 2005
  • In this research, We'll focus on warm environment and ventilation characteristics when utilizing intake ports, exhaust port and 4-way cassettes for removing heat and polluted air. Four way cassettes have been typical air conditioning units for offices since the multi air-conditioner was introduced. The following installation cases will also be discussed: 1) 4-way cassette's operation without intake ports and exhaust port. 2) Effect of the position of intake port and exhaust ports. 3) cooling air flow, temperature. distribution and local supply index according to the air flow rate from 4-way cassettes.

디젤기관의 LPG 혼합에 의한 오염배출물 저감특성 (Emission characteristics of diesel engine by mixing LPG)

  • 장영준;전충환;이춘우
    • 오토저널
    • /
    • 제15권2호
    • /
    • pp.44-52
    • /
    • 1993
  • In this study, the characteristics of decreasing exhaust gas of diesel engine was examined in dual fuel method by using commertial LPG for automotive. LPG was supplied to engine intake port by fumigation method and flow rate was controlled by using the needle valve. LPG supply ratios were 0, 20, 30% of total fuel amount to be supplied to engine by mass base. We investigated the effect of LPG supply ratio on exhaust gas concentrations related to excess air ratio and engine load at 1600, 1800, 2000 rpm. Soot concentration decreased about 30% in proportion to the increase of the LPG supply ratio. NOx concentration decreased in proportion to the increase of the LPG than diesel only and the increase rate was higher at low engine load. BSFC(Brake specific fuel consumption) was lower in proportion to the increase of the LPG supply ratio at high engine load and to the decrease of LPG supply ratio at low engine load.

  • PDF

포트각도에 따른 2행정기관 실린더내의 유동장 해석 (Analysis of the flow field in two-stroke engine cylinder of different intake ports angles)

  • 홍기배;최영진;유홍선;정인식
    • 오토저널
    • /
    • 제15권1호
    • /
    • pp.55-66
    • /
    • 1993
  • The characteristics of the flow processes in the cylinder of the two-stroke cycle engines have become the subject of increasing and attention owing to the simplicity and the higher power per unit weight of the two-stroke cycle engine. Among the many factors which influence on the scavenging flow, the port angle is important factor. Hence, four different type models with one inlet-port and two side-ports are studied to show the effect of port angle on the laminar scavenging flow. When the inlet-port axial is relatively larger than the side-port axial angle, it is showed that the fresh charge penetrate into the burned gas and displace it first toward the cylinder head and then toward the exhaust port. When the inlet-port axial angle is much less than the side-port axial angle, the fresh charge through the inlet-port directly move toward the exhaust port. The result showed that the model A may suppress the generation of vortices in the vicinity of inlet and side prots which restrict the sufficient supply of fresh charge and obstruct the perfect displacement of all combustion products.

  • PDF

밀폐공간에서 급·배기구 위치에 따른 누출 가스의 환기효과에 관한 실험적 연구 (Experimental Study on Ventilation Efficiency of Leakage Gas Based on Supply and Exhaust Vent Location)

  • 김하영;이성민;김별;황광일
    • 한국항해항만학회지
    • /
    • 제48권4호
    • /
    • pp.274-283
    • /
    • 2024
  • 기후변화는 가장 중요한 환경 문제 중 하나로, 이 변화의 주요 원인은 화석연료 사용으로 인한 탄소배출이다. 이에 대응하기 위해 다양한 대체 연료가 주목받고 있다. 이 중에서도 수소는 대용량 저장 및 대규모 운송 등 연료로서 많은 장점을 가지고 있지만 극인화성 기체이며 빠르게 확산되는 특성이 있어 수소를 다루는 시설에서는 환기를 통해 내부 안전을 확보하는 것이 필요하다. 본 연구는 밀폐공간에서 수소가 누출될 경우, 효율적으로 배출시킬 수 있는 급·배기구의 위치를 비교 및 분석하는 것을 목적으로 한다. 실험은 총 6가지의 급기구와 배기구 조합으로 시나리오를 구성하였다. 실험과정의 안전을 고려하여 수소 대신 물리적 성질이 유사한 헬륨을 사용하여 환기시스템이 작동 중일 때의 내부 산소농도를 분석하였다. 실험결과, 6가지 시나리오 중에서 하부측면의 급기구와 상부측면의 배기구를 활용한 환기(Case2)가 4분 30초로 가장 짧은 환기소요시간을 나타내었다. 더 나아가 상·중·하부 영역에 따른 산소농도감소율을 확인한 결과, 상부 영역에서는 상부면 급기구와 상부면·상부측면에 두 개의 배기구를 활용한 환기(Case6)가, 중부와 하부에서는 Case2가 낮은 값을 보였다.

직분식 디젤기관의 메탄올 흡기분사에 의한 기관성능과 배기배출물에 관한 연구 (A Study on the Engine Performance and Exhaust Emission with Intake Port Methanol Injection in a DI Diesel Engine)

  • 김명수;라진홍;안수길
    • 수산해양기술연구
    • /
    • 제36권3호
    • /
    • pp.249-256
    • /
    • 2000
  • In order to investigate the effectiveness of methanol, which has high latent heat of evaporation and oxygen contents, for DI diesel engine performance and exhaust emission, the methanol was injected at the suction port of DI diesel engine. The injector used for test was conventional gasoline engine injector and controlled the quantity of methanol per cycle by the power supply controller which designed specially for injector. The results shown that the maximum pressure point was delayed, the value of maximum pressure was decreased, and the concentrations of both NOx and Soot were decreased, as the methanol injection quantity increased, and also the thermal efficiency of engine injected methanol under the high load condition was similar to no methanol injection but under the medium load condition was decreased within the experimental conditions.

  • PDF

역단류 소기방식을 갖는 2행정 프리피스톤 수소기관의 열효율 향상에 관한 연구 (An Investigation on Enhencing Thermal Efficiency of a Hydrogen Fueled 2 Stroke Free-piston Engine with Reverse Uni-flow Scavenging)

  • 변창희;백대하;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제22권3호
    • /
    • pp.299-304
    • /
    • 2011
  • A hydrogen fueled 2 stroke free-piston engine with reverse uni-flow scavenging have a advantageous structure for the backfire occurrence, but it can reduce thermal efficiency by the circuit-flow to go through a exhaust-port. In this research, varied boost pressure, SVOT and exhaust pressure are used in a 2stroke free-piston engine with hydrogen fueled for studying the possibility of increasing thermal efficiency of free-piston hydrogen engine. As a result, to increase thermal efficiency of free-piston are suitable to supply the mixture after port closed the exhaust rater than to use the scanvenging. And it was increased by the exhaust pressure, to achieve it must be used the lean-mixture at SVOT aBDC $34^{\circ}$.

유공성 수평격판을 가진 열원이 있는 밀폐공간내의 온도분포 특성 (Characteristices of Temperature Distribution in a Closed Space with Heat Source and Porous Horizontal Partition)

  • 박찬수;조대환;전철균
    • 한국해양공학회지
    • /
    • 제13권3B호
    • /
    • pp.29-37
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-${\epsilon}$ model was carried out. In the present study, the marine engine room is separated to two floors with porus horizontal partition and considered as a closed space with a heat source and forced ventilation ducts. The porosity of horizontal partition is found to be important. For the engine room with 2 supply ports & 2 exhaust ports, the increasing of the porosity of horizontal partition is effective to reduce the recirculation flow zone in the second floor. When the engine room is ventilated with three supply air ports & one exhaust port, the increasing of the porosity of horizontal partition is effective to reduce the recirculating flow zone in the exhaust air area, but there is a possibility of local extreme heating at the lower side of engine near bottom.

  • PDF