• 제목/요약/키워드: Supply air velocity

검색결과 124건 처리시간 0.026초

열원이 있는 밀폐된 선박 기관실에서의 난류기류에 관한 수치적 연구 (Numerical simulation of turbulent air-flow in a closed engine room with heat source in a ship)

  • 박찬수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권1호
    • /
    • pp.100-107
    • /
    • 1998
  • Ventilation of the marine engine room is very important for the health of the workers as well as the nomal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-.epsilon. model was carried out. In the present study, the marine engine room is considered as a closed space with a heat source and forced ventilation ducts. The injection angle of air supply is found to be important. Injection with downword angle depresses recirculation flow, causing a strong steam in the wider space of the room. Ventilation and removal of the released heat are promoted with this pattern. There is a possibility of local extreme heating at the upper surface of engine when supply and exhaust ports of air are in bilateral symmetry. The effect of the increase of exhaust port area on ventilation decreases as the number of supply port increases.

  • PDF

Gasoline Spray Characteristics Impinging onto the Wall Surface in Suction Air Flow

  • Kim, Woo-Tae;Kang, Shin-Jae;Park, Byung-Joon
    • Journal of Mechanical Science and Technology
    • /
    • 제14권12호
    • /
    • pp.1376-1385
    • /
    • 2000
  • This study investigates spray characteristics before and after wall impingingment of gasoline spray in suction air flow. For this study, a rectangular model intake port was made of acrylic glass, and suction air was generated by using the forced air blower contrariwise. The injector for this study was a pintle-type port gasoline injector in which an air-assist adaptor is installed to supply assisted air. A PDPA system was employed to simultaneously measure the size and velocity of droplets near the wall. Measured droplets are divided into "pre-impinging droplets"with positive normal velocity and "post-impinging droplets"were negative normal velocity for the suction flow. The velocities, size distributions and Sauter mean diameter(SMD) of pre-and post-impinging droplets for varions injection angles and air-assists are comparatively analyzed.

  • PDF

페리미터존의 에어배리어 공조방식에 따른 실내 열환경 평가 (Evaluation of Indoor Thermal Environment According to Air-Barrier Air Conditioning System in Perimeter Zone)

  • 박병윤;함흥돈;손장열
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.370-376
    • /
    • 2005
  • For the purpose of investigating the effective removal of heating/cooling load from light-weighted building envelope, two air-conditioning systems, conventional parameter air-conditioning system and air-barrier system, are evaluated and compared by both experiment and simulation with six different cases during heating and cooling season. In addition, the characteristics of window-side building thermal load are assessed by varying supply air velocity in order to seek the optimal system operation condition. The results are as follows. 1) Air-barrier system is more effective to remove heating/cooling load at perimeter zone than conventional parameter air-conditioning system. Moreover, the better effectiveness appears during cooling season than during heating season. 2) The experiment during cooling season provides that indoor temperature of air-barrier system shows $1^{\circ}C$ less than that of the conventional system with similar outdoor air temperature profile, and indoor temperature distribution is more uniform throughout the experimented model space. It concludes that air-barrier system can achieve energy saving comparing to the conventional system. 3) The capturing efficiency of air-barrier system is 0.47 on heating season and 0.2 on cooling season with the same supply air volume. It results that the system performs effectively to remove building thermal load, moreover demonstrates high efficiency during cooling season. 4) The simulation results provide that capturing efficiency to evaluate the effective removal of building load from perimeter zone shows high value when supply air velocity is 1 m/s.

급기가압 제연설비의 내부 유동특성에 대한 수치해석 (Numerical Analysis on Flow Characteristics in the Pressurized Air Supply Smoke Control System)

  • 고권현
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.52-58
    • /
    • 2017
  • 본 연구에서는 급기가압에 따른 건축물 내부의 공기유동에 대한 수치해석을 수행하고 거실, 부속실 및 계단실 간의 차압분포 및 유동 특성을 분석하였다. 유동 해석은 유효누설면적을 측정하기 위해 제작된 누기율 시험설비에 대하여 수행하였으며, 급기가압에 따른 각 실의 압력 및 유속분포 등을 분석하였다. 본 해석에서 공기의 누설은 유효누설면적을 갖는 얇은 틈새를 방화문과 창문에 위치시키는 방법으로 모사하였다. 이러한 방법을 이용한 해석은 계단실과 부속실 간의 차압에 대한 기존 실험의 결과를 적절히 예측하였다. 해석 결과를 통해 국부적인 누설이 급기가압 제연 설비의 전체적인 유동 패턴 및 압력 분포에 큰 영향을 미치지 않음을 확인하였다. 거실-부속실 문 단면에서의 평균속도가 방연풍속에 대한 국가화재안전기준을 만족하였으나 문의 상부와 같은 국부적인 위치에서 부속실로의 유출이 발생할 수 있음을 확인하였다.

릴리프밸브 쿠션기구 내장형 공기압 실린더의 구동 특성 (Driving Characteristics of Pneumatic Cylinder with Relief Valve Cushion Devices)

  • 김도태
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권4호
    • /
    • pp.7-13
    • /
    • 2016
  • This paper presents the meter-out and meter-in speed control characteristics of a pneumatic cylinder with relief valve type cushion device. The piston displacement and velocity are measured to investigate high speed driving performance with variation of the pressure setting in relief valve, air supply pressure, load mass, the supply and exhaust flow rate from the cylinder. Also, the internal pressures and temperatures driving pressure and cushion chamber are measured. The piston displacements and velocities of meter-out and meter-in control are compared experimentally determined data. A comparison experimental data meter-out and meter-in control show that a relief valve type cushion device is suitable for high speed pneumatic cylinders. The desired response characteristics of piston displacement and velocity are satisfactory adjust the pressure setting of a relief valve with varying system parameters such as air supply pressure, load mass and controlled flow rate.

A Numerical Study on the Reduction of Water Hammering in a Simple Water Supply Pipe System

  • Lim, Ki-Won;Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.51-61
    • /
    • 2001
  • A numerical study has been conducted to characterize the transient pressure in a simple water supply pipe system with an air chamber by utilizing a commercial code that employs the method of characteristics. Some results produced for validation in the study agree quite well with the previously reported. Several parameters are than varied. Among them are the valve closure time, the wave speed, the static pressure, the polytropic exponent, the air chamber volume, the diameter and the shape of orifice in the air chamber, etc, while the water temperature and velocity are kept constant at $20^\circ{C}$ and 0.8m/s, respectively. Results reported in this parametric study may be useful to understand the unsteady behavior of the system.

  • PDF

공동주택 화장실의 기계 환기시스템에 관한 연구 (A Study on the Mechanical Ventilation System of Bathroom in Apartment House)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제12권3호
    • /
    • pp.141-148
    • /
    • 2001
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$\textrm{m}^2$, were made and installed in a laboratory. These ventilation mock-ups were available for control of air supply and exhaust, and the sizes of supply openings were 40cm${\times}$1cm, 40cm${\times}$3cm, and 40cm${\times}$5cm. They were installed at five positions, spaced 45cm at a height of 5cm from the floor. The exhaust fan was designed for its operating voltage to be set to five steps(100V, 130V, 150V, 180V and 220V) in order to control its air flow rates. When the size and position of each supply opening were changed with the wind velocity of the exhaust fan set to the step 5, the ventilation rates were measured and analyzed by the concentration decay method of tracer gas method, in order to present an efficient mechanical ventilation system. The results of the study revealed that the ventilations rates would increase in the presence of supply openings, compared to the absence of supply openings, and that the larger the size of the supply opening, the more the ventilation rates. Therefore, it was found necessary to take air supply into consideration.

  • PDF

핀-튜브 열교환기에서의 습증기 발생 메커니즘의 파악을 위한 실험적 연구 (An Experimental Study on Understanding of Production Mechanism of a Mist from Fin-Tube Heat Exchanger)

  • 박상균;윤석훈;김경근;김명환;오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.595-604
    • /
    • 2001
  • As an improvement in the standard of living and economic growth, the demand for air conditioning equipment is increasing rapidly. Nowadays, air conditioning equipments are being used for industry, large building, house and car. There equipments were concentrated on improving heat efficiency of economic aspects while thy design heat exchanger for cooling and heating. These air conditioning equipments using heat exchanger cause a discomfort to user due to generating mist at the beginning of operating. Therefore, the user demand air of high class and quality. In this experimental study, to acquire elementary data for development of heat exchanger which be able to supply air of high quality, that is to say, possess a restraint effect of mist generation. We estimate an effect on cooling plate quality, supply air velocity, supply air temperature, cooled plate temperature and supply air relative humidity which have an influence on outlet air condition of heat exchanger.

  • PDF

클린룸의 상부 플레넘 설계를 위한 유동특성 실험 (Airflow Characteristic Experiments for the Upper Plenum Design of Clean Room)

  • 오명도;배귀남;김석철;이춘식
    • 설비공학논문집
    • /
    • 제1권4호
    • /
    • pp.276-289
    • /
    • 1989
  • The airflow characteristics in both the upper plenum and the clean space of clean room are investigated by measuring the pressure distribution of the upper plenum and the velocity profile in the clean space, at the various conditions of the supplied airflow rate, the volume of upper plenum and the air supply type. The performance of vertical air supply type and horizontal air supply type is analyzed in terms of the airflow uniformity which is frequently used in indicating the clean room performance, and the relations among the volume of upper plenum, the supplied airflow rate and the airflow uniformity are confirmed. The results of this experimental study can be applied to the designing of the upper plenum of clean room.

  • PDF

화재 시뮬레이션(FDS)을 이용한 거실제연설비 개선에 관한 연구 (A Study on Improvenment of Livingroom Smoke-control System using the FDS)

  • 김미선;백은선
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.26-34
    • /
    • 2017
  • 본 논문은 거실제연설비의 인접구역 상호제연방식의 성능 확인 및 향상을 위한 논문으로써 국가화재안전기준(NFSC)과 NFPA 연기제어에 관한 규정을 비교 분석하였다. 분석방법은 화재 시뮬레이션(FDS)을 통해 모델링을 실시하여, 급기량 변화, 제연경계의 폭, 화재실내 가연물 변화, 유입공기의 풍속차이를 통해 이루어졌다. 그 결과 청결층 확보를 위해 급기량을 배출량 이하로 하였을때 화재실에서의 청결층 확보에 유리한 것으로 나타났으나 급기실에서는 급기량을 배출량 이상으로 하였을때 청결층 확보에 유리한 것으로 나타났으며, 제연경계의 폭이 길어질수록 성능 확보에 유리한 것으로 나타났다. 또한 가연물의 종류에 따라 급기량과 배출량을 고려해야 하며, 공기유입구 풍속은 급기량을 감소시킴과 동시에 공기유입구 풍속을 낮게 하므로써 화재실의 청결층 확보에 유리한 것으로 나타났다.