• Title/Summary/Keyword: Super-Efficiency

Search Result 360, Processing Time 0.038 seconds

An Efficiency Analysis for the Public Activities Support Projects of Non-Profit Private Organizations using DEA (비영리민간단체의 공익활동 지원사업 효율성분석)

  • Choi, Hong-Geun;You, Yen-Yoo
    • Journal of Digital Convergence
    • /
    • v.12 no.6
    • /
    • pp.181-192
    • /
    • 2014
  • This study suggests consulting directions for non-profit private organizations which were found to be inefficient in the efficiency analysis for the public activities support projects on those organizations performed by the Korean government. An ANOVA analysis on seven types of public activities support projects showed that there were differences among those types. By applying CCB-I, BCC-I, Super efficiency models among DEA, performance efficiencies were analyzed. Four input elements (age of the organization, supported amount, number of members, and the number of workers) and three output elements (project scores, financial scores, and comprehensive scores) were analyzed, and high efficient organizations were found as benchmarking objects, and, through super efficiency analysis, those objects were classified into short, mid, and long-term objects. Through such methods, this research provided organizations with the best information on other organizations to learn from and improve themselves.

An Analysis of Forwarding Companies' Efficiency handling Overseas Construction Project Logistics using DEA (DEA분석을 활용한 건설프로젝트 화물포워딩 업체의 효율성 분석)

  • Lee, Jun-Woo;Park, Sung-Hoon;Oh, Jae-Gyun;Yeo, Gi-Tae
    • Journal of Digital Convergence
    • /
    • v.16 no.6
    • /
    • pp.75-84
    • /
    • 2018
  • Although many logistics companies are interested in project logistics, the existing research has been limited to the growth potential of project logistics market and the high barrier and importance of project logistics. This study analyzes using DEA the operational efficiency of forwarding companies registered in major overseas construction EPC companies and performing logistics services for overseas plant construction projects. For efficiency analysis, Super-SBM analysis and Malmquist analysis are used among DEA analysis techniques. As a result of the Super-SBM analysis, DMU 5 ranked first at 1.807. DMU 5 is more efficient than the other large corporations because it has the stable supply of its parent company H and the smallest input and output variables among the large corporations. As a result of Malmquist analysis, TCI, which is a technological development, showed a fluctuation while TECI showed a relatively stable variation. In addition, there is a difference in scale between major companies and small and medium sized companies. So, it is necessary to identify the efficiency improvement strategy for each group and apply it to the practical work.

증기조건 향상에 따른 증기터빈 기술동향

  • Na, Un-Hak
    • 열병합발전
    • /
    • s.36
    • /
    • pp.16-21
    • /
    • 2003
  • For many years, T/G Supplier has constructed a number of thermal power plants and researched to improve the performance and the reliability of steam turbine, which are achieved by advances in design and materials technology. In recent, interest is renewed in advance steam condition as means of improving economy of thermal power plant and reducing environmental pollution. Improvements in the maximum power have been driven by the development of advanced rotor and bucket material and longer last stage bucket. Improvements in efficiency have been brought through advance in mechanical efficiency and thermodynamic efficiency. This paper describes a number of new steam path design features introduced to the steam turbine product. And also this paper describes new design technologies' development, new technologies' trend and technologies' development for ultra-super critical steam turbine.

  • PDF

Steam Turbine Technology for Advanced Steam Condition (증기조건 향상에 따른 증기터빈 기술 동향)

  • Nah, U.H.;Cho, S.I.;Shin, H.;Kim, Y.S.;Yang, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2174-2179
    • /
    • 2003
  • For many years, T/G Supplier has constructed a number of thermal power plants and researched to improve the performance and the reliability of steam turbine, which are achieved by advances in design and materials technology. In recent, interest is renewed in advanced steam condition as means of improving economy of thermal power plant and reducing environmental pollution. Improvements in the maximum power have been driven by the development of advanced rotor and bucket material and longer last stage bucket. Improvements in efficiency have been brought through advances in mechanical efficiency and thermodynamic efficiency. This paper describes a number of new steam path design features introduced to the steam turbine product. And also this paper describes new design technologies' development, new technologies' trend and technologies' development for ultra-super critical steam turbine.

  • PDF

A study on the Insulation Performance of the SuperWindow considering the Evaluation of Building Energy Rating (건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가)

  • Jang, Cheol-Yong;Kim, Chi-Hoon;Ahn, Byung-Lip;Hong, Won-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend.In addition, the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1) The insulation performance of super window system is $1.44\;W/m^2^{\circ}C$ 2) Super Window compared to a normal window reduce heating energy requirements have been 5.3% 3) Compared to a normal window, Super window savings rate was 4.1% lower 4) Building energy efficiency rating was up to 1 rating from 2 rating.

Study on the High Efficiency Design of IE4 Synchronous Reluctance Motor Replacing IE3 Induction Motor (블로워용 IE3 유도전동기 대체 IE4 동기 릴럭턴스 전동기 고효율 설계 연구)

  • Liu, Huai-Cong;Kim, In-Gun;Jeong, Je-Myung;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.411-418
    • /
    • 2016
  • In accordance with global energy conservation policies such as MEPS(Minimum Energy Performance Standard), electric motor industry is moving to super-high-efficiency machines and research to develop IE4 (International Energy Efficiency Class4) motors has been launched. In this situation, SynRM (Synchronous Reluctance Motor) has been attracting attention in place of induction motor which hardly provides super premium efficiency. As a result, much research on SynRM is being performed at home and abroad. Also, some products have already been appearing in the market. Compared to induction motor, SynRM has better efficiency per unit area and wider operating range. Although the utilization of control system in synchronous motor results in higher prices, we still need to concentrate on developments of SynRM so as to comply with the new policies. This study demonstrated the electromagnetic design methods of super-premium SynRM while maintaining the frame of existing IE3 induction motor for blower. We documented the design procedures for generating high saliency which is the most essential and mechanical stress analysis is also treated. In conclusion, we proved the validity of our design by manufacturing and testing our SynRM models.

A Fundamental Study on the Workability and Engineering Properties of Super High Strength Concrete Replaced Cement As Fly ash (플라이애쉬를 대체한 초고강도 콘크리트의 시공성 및 공학적 특성에 관한 기초적 연구)

  • 류광일;윤병수;김진만;남상일;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.5-10
    • /
    • 1993
  • Recently, owing to efficiency of the concrete work and the rationalization of construction structures, concrete is required to be super high strength. Furthermore, it is take a growing interest in execution and manufacture for super high strength concrete. This study is to investigate and analyze the influenced of flyash affecting on workability and engineering properties of super high strength concrete. In this experiment, the 28day's compressive strength of concrete using 15mm size of aggregate and flyash is over 800㎏/㎠ in the 20°/wt of water∼cement ratio. And the concrete using flyash have higher tensile strength than plain concrete.

  • PDF

A study on the Insulation Performance of the Super Window applied to building energy efficiency rating (초단열 슈퍼윈도우의 건물에너지효율등급 적용 연구)

  • Jang, Cheol-Yong;Kim, Chi-Hoon;Ahn, Byung-Lip
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.205-210
    • /
    • 2009
  • Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend. According to the flow of energy is lost from the building, will be achieved through the walls and roof and windows. Among these, the window through the loss of about 45% of the entire building is big enough to rate. In addition, the building regulation U-value Limitation of window is $3.3W/m^2$ K in southern regions, while U-value Limitation of wall is $0.35{\sim}0.58W/m^2$ K. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1)Thermal performance of insulated Super Window measured as $1.44W/m^2$ $^{\circ}C$ 2)Required energy for heating was cut down about 5.3% from 266.99 $MJ/m^2$ yr to 252.85 $MJ/m^2$ yr 3)Super Window's reduction rates increased 4.1% from 31.48% to 35.58% when it is compared to normal windows. 4)Building energy efficiency rating elevated from 2nd rating to 1st rating.

  • PDF

A Study on the Characteristic of Energy Consumption in the Super High-rise Mixed-use Housing (초고층 주상복합 아파트의 에너지 소비특성에 관한 연구)

  • Lee, Byunghee;Lee, Jaehyuk;Je, Heaseong;Kang, Dongho
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.63-69
    • /
    • 2010
  • Recently, by the increase of demand on Super High-rise mixed-use housing and it's advanced quality, the interest on it has been raised socially. In accordance with it, the matter of resident's health and energy efficiency has been controversial in terms of living in super high-rise housing. This study started from the idea that it is necessary to have an objective data which that has many residents in narrow space with high density. The purpose of this study are as follows; Firstly, with the quantitative data analysis on energy, it will confirm the objective information on the unclear negative idea of super high-rise mixed-use housing. Secondly, it will establish the fundamental data on the energy of super high-rise mixed-use housing by examining the characteristic of energy consumption of the complex which was built more than 5 years ago. There are 4 methods of this study. Firstly, it follows the steps of theoretical view, and defines concept to study on the characteristic of super high-rise mixed-use housing. Secondly, referring to the previous study, it provides better understanding on th stream of this research and the limit as well to guide the direction in terms of energy consumption. Thirdly, it evaluates the characteristic of monthly consumption by researching the use of electricity energy and heating energy of super high-rise mixed-use housing. The major conclusions of this study are as follows; Firstly, the heating use of apartment complex is same, which is not influenced by the type of the building. Secondly, the electricity use of super high-rise mixed-use housing is from 1,2 to 1.5 as high as the normal apartment.

Measurement and Comparison of Wi-Fi and Super Wi-Fi Indoor Propagation Characteristics in a Multi-Floored Building

  • Hwang, Gyumin;Shin, Kyubo;Park, Sanghyeok;Kim, Hyoil
    • Journal of Communications and Networks
    • /
    • v.18 no.3
    • /
    • pp.476-483
    • /
    • 2016
  • Super Wi-Fi is a Wi-Fi-like service exploiting TV white space (WS) which is expected to achieve larger coverage than today's Wi-Fi thanks to its superior propagation characteristics. Super Wi-Fi has been materialized as an international standard, IEEE 802.11af, targeting indoor and outdoor applications, and is undergoing worldwide field tests. This paper demonstrates the true potential of indoor Super Wi-Fi, by experimentally comparing the signal propagation characteristics of Super Wi-Fi and Wi-Fi in the same indoor environment. Specifically, we measured the wall and floor attenuation factors and the path-loss distribution at 770MHz, 2.401 GHz, and 5.540 GHz, and predicted the downlink capacity of Wi-Fi and Super Wi-Fi. The experimental results have revealed that TVWS signals can penetrate up to two floors above and below, whereas Wi-Fi signals experience significant path loss even through a single floor. It has been also shown that Super Wi-Fi mitigates shaded regions of Wi-Fi by providing almost-homogeneous data rates within its coverage, performs comparable to Wi-Fi utilizing less bandwidth, and always achieves better spectral efficiency than Wi-Fi. The observed phenomena imply that Super Wi-Fi is suitable for indoor applications and has the potential of extending horizontal and vertical coverage of today's Wi-Fi.