• Title/Summary/Keyword: Sunless Days

Search Result 7, Processing Time 0.02 seconds

A Study on the Economic of Electrical Storage Device of Stand Alone PV/Wind Hybrid System Based upon Sunless Days (부조일에 따른 독립형 태양광 풍력 복합발전 시스템에서 전기저장장치의 경제성에 관한 연구)

  • Choi, Byoung-Soo;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.3
    • /
    • pp.16-23
    • /
    • 2012
  • This paper relates to a study on the economic of electrical storage device for supplying power in sunless days, in the stand alone PV/Wind hybrid system, which it is applied to separate houses. In a photovoltaic/wind hybrid power system used in a separate house, when only the battery is used in sunless days, the capacity of the battery is become larger. For example, as in recent days, if cloudy days are frequent due to anomaly climate, it is difficult to supply power stably by only the battery based upon pre-estimated sunless days. Accordingly, in order to supply stably power of new renewable energy such as solar to any separate houses, it is preferable to reduce the capacity of battery by decreasing the number of sunless days when estimating the capacity of battery and to drive the small generator for compensation of the power shortage.

A Study on Sizing of Battery for Effective Operation of Stand-alone Renewable Generation System (독립형 신재생발전 시스템의 효율적인 운영을 위한 배터리 용량산정에 관한 연구)

  • Shin, Hee-Sang;Hue, Jae-Sun;Yun, Sang-Yun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.15-20
    • /
    • 2018
  • This paper presents the method of ESS energy capacity calculation for stand-alone renewable energy generation system consisting of photovoltaic energy. There is almost no power from photovoltaic system during sunless days. So this source is very weak in terms of the power supply reliability. To improve problem of power supply, battery is mainly used Energy Storage System(ESS). The number of sunless days and Depth of Discharge(DOD) is important factor to determine energy capacity of battery. However, a many study for economical design is required due to the high cost of ESS. In this paper, we propose the new method of ESS energy capacity calculation by applying different DOD for operation with and without sun. We determine the Battery capacity using higher DOD of operation during sunless day than the DOD of the normal operation. And we carried out an economic analysis of the calculation results.

The Study on the Controller for Supplying Stably Power with a Stand-Alone Photovoltaic/Wind/Small Generator Hybrid Power Generation System (독립형 태양광, 풍력, 소형발전기 복합시스템에서 안정적인 전력공급을 위한 컨트롤러에 관한 연구)

  • Choi, Byoung-Soo;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.48-56
    • /
    • 2012
  • The object of this paper is the controller for supplying stably power in a separate house in which a hybrid electrical storage system with a stand-alone photovoltaic/wind power generation system and a small generator is applied. In the photovoltaic/wind hybrid power system used in the separate house, when only the battery is used in sunless days, the capacity of the battery is become larger. In particular, as in recent days, if cloudy days are frequent due to anomaly climate, it is difficult to estimate the number of sunless days. Accordingly, it is preferable to build the electrical storage system that numbers of sunshineless days are to be controlled and a shortage amount of the power generation capacity is to be handled by a small generator system. In order to supply stably power of new renewable energy such as solar to any separate houses, it is preferable to reduce the capacity of battery by decreasing the number of sunless days when estimating the capacity of battery and to drive the small generator for compensation of the power shortage. Such system needs components including inverters for photovoltaic and wind power generation system, batteries and controllers for automatically driving the small generator, based upon the nature of the stand-alone house, and it is preferable to use the controller having a simpler and higher stability by adopting the all-in-one scheme to facilitate its maintenance.

Regional Division According to the Annual Change of Sunshine Duration in Korea (일조시간의 연변화에 따른 한국의 지역구분)

  • 문영수
    • Journal of Environmental Science International
    • /
    • v.5 no.3
    • /
    • pp.253-263
    • /
    • 1996
  • This study is an attempt to classify climatic regions of Korea based on the data of sunshine duration and to clarify the characteristics of sunshine for each divided regions. The data used in this study are the mean values of monthly and ten-daily sunshine duration, sunshine percentage, solar radiation and proud amount obtained from 63 weather stations of the Korea Meteorological Administration during the period of 1974~ 1993. The characteristics of annual change of sunshine percentage, annual duration of sunshine, percentage of sunshine, annual radiation, amount of cloud, days of sunshine percentage above 80% and-days of sunless are investigated by the mean values of -the stations belong to divided regions. The ward method of hierarchical cluster analysis is adopted to the analysis of data for the regional division. The results obtained in this study are summarized as follows. (1) The sunshine regions of Korea can be divided into six regions of the central west, central east, south west, souls east, Ullung-do and Cheju-do. These are strongly affected by the dirtribution of inclined slopes taking account of the topographic characteristics of Korea. (2) Annual distribution shows the sunshine duration of 1777~ 2287 hours, sunshine percentage of 40~53%, solar radiation of 3469~4637 MJ/$m^2$, cloud amount of 5.0~6.1, days of sunshine perrentage above 80% of 53~116days and sunless days of 46~71days. (3) The types of annual change of sunshine percentages is classified with four types of minimum in July and maximum in October, minimum in July and maximum in December, high in May and October and low in July and January, high in May and November and low in June and January. (4) The long-term trend of sunshine duration decrease in peninsula area but increase in island area and the Tong-term inclination of cloud amount is almost zero. The author believe this tendency is related to a pollutional turbidity than a cloud amount in inland area.

  • PDF

A Study on Efficient Management of Solar Powered LED Street Lamp Using Weather forecast (기상예보를 이용한 태양광 LED 가로등의 효율적 운용에 관한 연구)

  • Pyo, Se-Young;Kwon, Oh-Seok;Kim, Kee-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.129-135
    • /
    • 2015
  • This study, in the operation of street lamp, suggests appropriate algorithm to extend the number of days of street lamp operation as much as possible if the number of sunless days continues and experimentally determines the value of Weather Factor necessary for this algorithm. This is conducted by reducing electricity consumption and securing battery remains through the use of standby power mode, in which maximum amount of light is maintained if there is a pedestrian, and constant brightness is maintained without utilizing maximum electric power if no pedestrians exist, with the application of WFactor value created by the algorithm considering weather forecast and amount of sunlight.

Optimal Sizing Method of Distributed Energy Resources for a Stand-alone Microgrid by using Reliability-based Genetic Algorithm (신뢰도 기반의 유전자알고리즘을 활용한 독립형 마이크로그리드 내 분산형전원 최적용량 산정 방법)

  • Baek, Ja-Hyun;Han, Soo-Kyung;Kim, Dae-Sik;Han, Dong-Hwa;Lee, Hansang;Cho, Soo-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.5
    • /
    • pp.757-764
    • /
    • 2017
  • As the reduction of greenhouse gases(GHGs) emission has become a global issue, the microgrid markets are growing rapidly. With the sudden changes in the market, Korean government suggested a new business model called 'Self-Sufficient Energy Islands'. Its main concern is a stand-alone microgrid composed of Distributed Energy Resources(DERs) such as Renewable Energy Sources(RESs), Energy Storage System(ESS) and Fuel Cell, in order to minimize the emission of GHGs. According to these trend, this paper is written to propose an optimal sizing method of DERs in a stand-alone microgrid by using Genetic Algorithm(GA), one of the representative stochastic methods. It is to minimize the net present cost with the variables, size of RESs and ESS. In the process for optimization, the sunless days are considered as additional constraints. Through the case study analysis, the size of DERs installed in a microgrid system has been computed using the proposed method in MATLAB. And the result of MATLAB is compared with that of HOMER(Hybrid Optimization of Multiple Energy Resources), a well-known energy modeling software.

A Study on the Installation Angle of the Marine Solar Power Generation System (해상용 태양광 발전 시스템의 설치 각도에 관한 연구)

  • Oh, Jin-Seok;Jang, Jae-Hee
    • Journal of Navigation and Port Research
    • /
    • v.42 no.3
    • /
    • pp.167-176
    • /
    • 2018
  • A solar power generation system on single point moored offshore plant has independent power system In order to satisfy the maritime environment and account for the number of sunless days, it is important to supply stable electric power to the systems. For these reasons, solar panels are installed in multiple directions. However, a partial shading effect occurs because the amount of light incident on each panel is different. The generated power by the solar generation system installed on land is affected by the latitude, then it is installed at an angle of 30 to $45^{\circ}$. in the case of Korea. In the case of a solar power generation system installed in a mooring type of marine plant, there is a possibility that the maximum power point is outside of the controllable range due to the partial shading effect. Therefore, a power generation loss occurs. By reducing the light amount difference between both panels, the maximum power point can exist in a range where the MPPT algorithm can track the power. The purpose is so the power generation efficiency can be further increased. In this paper, simulation results show that the highest power generation efficiency is obtained at an installation angle of $20^{\circ}$.