• Title/Summary/Keyword: Sun-Acquisition Mode

Search Result 16, Processing Time 0.025 seconds

Papers : Attitude Determination Algorithm of LEO Satellites in the Sun - Acquisition Mode (논문 : 태양획득 모드에서 저궤도 위성의 자세결정 알고리즘)

  • An,Hyo-Seong;Lee,Seon-Ho;Lee,Seung-U;Chae,Jang-Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.1
    • /
    • pp.82-87
    • /
    • 2002
  • The attitude determination in LEO Satellite like KOMPSAT is one of the most important issues for Sun-Acquisition. Particularly, in KOMPSAT, the roll axis direction can be determined since the sun sensor gives the information on the Euler angle for pitch and yaw axes in Sun-Acquisition mode. In other words, it is the problem to determine the two unknown axes direction with one axis knowledge. This paper proposes a new effective method for attitude determination of general LEO satellites when one axis information is avilable and proves its usefulness throughout the simulation.

Gyroless Attitude Estimation of the Sun-Pointing Mode Satellite

  • Ahn, Hyo-Sung;Lee, Seon-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.876-881
    • /
    • 2003
  • Reliable attitude estimation during the launch and early orbit phase is a critical issue for a satellite. Typically gyroscopes and other sensors are utilized to estimate the attitude during this phase. It is difficult to estimate the attitude quickly and reliably using gyroscopes because it requires a large computational load and accurate sensor measurements. Furthermore, the gyroscope failure may lead to the loss of the satellite. This paper suggests a simple attitude estimation method of a low earth orbit satellite without using gyroscopes, but only using sun sensors and magnetometers in the sun-acquisition mode. Using Kompsat-I telemetry data, we verified that the suggested algorithm provides attitude estimation within 3 degrees on each axis.

  • PDF

A Study of The Development of an In-vehicle Data Acquisition and Analysis System (자동차 주행 성능 평가를 위한 주행 자료 획득 및 분석 시스템 개발에 관한 연구)

  • SunWoo, Myung-Ho;Ju, Won-Chul;Lee, Jae-In
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.487-489
    • /
    • 1998
  • To evaluate vehicle performances and driving behavior of a vehicle, it is necessary to acquisit and analyze vehicle data during the vehicle driving, which affect fuel economy and emissions. An in-vehicle data acquisition system, which is called Mode Survey System(MOSS), is designed and developed to analyze the traffic and driving patterns of the vehicle. MOSS is a stand-alone system based on the 68HC11 MCU. MOSS logs various data relating to powertrain and vehicle driving such as vehicle speed, engine RPM, gear position, brake, clutch, fuel consumption, and others. The driving patterns are dependent on the driver's habit and the road and traffic conditions, these driving patterns would be able to make a official driving mode to be used in emission, fuel efficiency, shift survey, catalyst durability, and other tests using the analyzed driving patterns.

  • PDF

Development of Confocal Imaging System for Wafer Inspection (개발 웨이퍼 검사위한 Confocal 이미징 시스템의 개발)

  • Ko, Kuk-Won;Nguyen, Cong Dai;Koh, Kyung-Cheol
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05a
    • /
    • pp.108-112
    • /
    • 2010
  • Confocal Imaging System is an essential machine for a wide range of inspection wafer. For concurrent and fast acquiring the image data of four channels, the new image acquisition system used the protocol of camera-link standard with the full mode of configuration in interconnection with a frame grabber integrated in a computer, which is popularly used for many cameras, so the programming environment of image processing is optional such as Visual C++, Matlab. In addition, many conventional methods were coordinately used for contribution to build the high quality of images for precise processing analog signals of PhotoMutiplier Tubes(PMTs), accurate control of scanning device, sensitivity of PMTs, and laser source. The prototype of new image acquisition system, could meet the goal of development, it is used in LSCM for high content screening to investigation the processes of elements of living specimens at the same time by simultaneous grab image data on 4 PMTs channels.

  • PDF

HIGH RESOLUTION IMAGE ACQUISITION MODE USING PANCHROMATIC REDUNDANT CHANNEL

  • Chang, Young-Jun;Kong, Jong-Pil;Huh, Haeng-Pal;Kim, Young-Sun;Park, Jong-Uk
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.800-803
    • /
    • 2006
  • The Space-borne electro-optical camera system, like KOMPSAT has panchromatic redundant image channel as well as primary channel in order to increase reliability of satellite system. In most case redundant channel never been used during the whole mission period. Staggered array configuration using redundant image channel and new operation mode proposed which operates primary and redundant channel simultaneously. Without new hardware design, fast electronics and system complexity, we can get 1.414 times more fine GSD image of original system and aliasing effect which corrupt high frequency information of image can be minimized. To get the more efficiency from staggered array configuration, we introduce masked pixel CCD.

  • PDF

The Evaluation of Dynamic Continuous Mode in Brain SPECT (Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가)

  • Park, Sun Myung;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.15-22
    • /
    • 2017
  • Purpose During Brain SPECT study, critical factor for proper study with $^{99m}Tc-ECD$ or $^{99m}Tc-HMPAO$ is one of the important causes to patent's movement. It causes both improper diagnosis and examination failure. In this study, we evaluated the effect of Dynamic Continuous Mode Acquisition compared to Step and Shoot Mode to raise efficacy and reject the data set with movement, as well as, be reconstructed in certain criteria. Materials and Methods Deluxe Jaszczak phantom and Hoffman 3D Brain phantom were used to find proper standard data set and exact time. Step and Shoot Mode and Dynamic Continuous Mode Acquisition were performed with SymbiaT16. Firstly, Deluxe Jaszczak phantom was filled with $Na^{99m}TcO_4$ 370 MBq and obtained in 60 minutes to check spatial resolution compared with Step and Shoot Mode and Dynamic Continuous Mode. The second, the Hoffman 3D Phantom filled with $Na^{99m}TcO_4$ 74 MBq was acquired for 15 Frame/minutes to evaluate visual assessment and quantification. Finally, in the Deluxe Jaszczak phantom, Spheres and Rods were measured by MI Apps program as well as, checking counts with the frontal lobe, temporal lobe, occipital lobe, cerebellum and hypothalamus parts was performed in the Hoffman 3D Brain Phantom. Results In Brain SPECT Study, using Dynamic Continuous Mode rather than current Step and Shoot Mode, we can do the reading using the 20 to 50 % of the acquired image, and during the test if the patient moves, we can remove unneeded image to reduce the rate of restudy and reinjection. Conclusion Dynamic Continuous Mode in Brain study condition enhances effects compared to Step and Shoot Mode. And also is powerful method to reduce reacquisition rate caused by patient movement. The findings further indicate that it suggest rejection limit to maintain clinical value with certain reconstruction factors compared with Tomo data set. Further examination to improve spatial resolution, SPECT/CT should be the answer for that.

  • PDF

Study on the Exposure Dose(mAs) and acquisition Image set up Density Display and Sensitivity of control Panel for the Digital Flat-Panel-Detector (디지털 평판형 검출기에서 Control Panel의 Density Display와 Sensitivity 설정이 조사선량(mAs)과 획득영상에 미치는 영향에 관한 연구)

  • Kim, Byung-Ki;Kim, Sang-Keun;Cha, Seon-Hwa;Choi, Jun-Gu;Lee, Jun;Kim, Min-Woo;Kim, Sun-Bae;Kim, Gyeong-Sun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.17-21
    • /
    • 2007
  • The purpose to recognize change of average pixel value of acquisition image by control panel's density and right set up method of speed (sensitivity) and exposure dose(mAs) change that dose in purpose digital flatpanel-detector. X -ray generator DHF-158H2(Hitachi, Japan). Detector CXDI 4OG(Canon, Japan), 12 : 1 grid and exposure ray 135 kVp, 250 mA, 10 ms. focus-detector distance 180 cm and used AEC mode. DICOM reflex analysis program used image J that is digital reflex analysis program that offer in United States America National Health Center(National Institutes of Health : NlH) phantom used chest phantom(Anthromorphic : Flukebrome.medicaI USA). An experiment chest phantom that consist by formation equivalence material use because density value( -3${\sim}$+3) in X-ray control panel and seep that is speed step(slow, medium, fast) each control experimentalize. image analysis reflex neted through an experiment using image j each image compare. These was change in dose according to slow, medium, fast and density's change in an experiment result. According to detector sensitivity and density condition set, dose was relationship dissimilarity 500% from 200%. The dose came highest when is density +3 to slow. and dose more increases gray scale's extent could know that rise. Could know whether how equipment set is important through this experiment. cause of disease which change by digital radiography system forward is thought to increase more, it is considered that suitable education by this and continuous interest about equipment need absolutely.

  • PDF

Influence of Resin-Infiltrated Time on Wood Natural Materials Using Conventional/Air-Coupled Ultrasound Waves

  • Park, Je-Woong;Kim, Do-Jung;Kweon, Young-Sub;Im, Kwang-Hee;Hsu, David K.;Kim, Sun-Kyu;Yang, In-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.3
    • /
    • pp.235-241
    • /
    • 2009
  • Composite wood materials are very sensitive to water and inspection without any coupling medium of a liquid is really needed to wood materials due to the permeation of coupling medium such as water. However, air-coupled ultrasound has obvious advantages over water-coupled experimentation compared with conventional C-scanner. In this work, it is desirable to perform contact-less nondestructive evaluation to assess wood material homogeneity. A wood material was nondestructively characterized with non-contact and contact modes to measure ultrasonic velocity using automated data acquisition software. We have utilized a proposed peak-delay measurement method. Also through transmission mode was performed because of the main limitation for air-coupled transducers, which is the acoustic impedance mismatch between most materials and air. The variation of ultrasonic velocity was found to be somewhat difference due to air-coupled limitations over conventional scan images. However, conventional C-scan images are well agreed with increasing the resin-infiltrated time as expected. Finally, we have developed a measurement system of an ultrasonic velocity based on data acquisition software for obtaining ultrasonic quantitative data for correlation with C-scan images.

The Consideration of Consistent Use of Sample Standard Deviation in the Confidence Interval Estimation of Population Mean and Population Ratio (모평균과 모비율의 구간추정에서 표본표준편차의 일관된 사용에 대한 고찰)

  • Park, Sun Yong;Yoon, Hyoung Seok
    • Journal of Educational Research in Mathematics
    • /
    • v.24 no.3
    • /
    • pp.375-385
    • /
    • 2014
  • This study compares the confidence interval estimation of population mean with that of population ratio, and considers whether these two estimations ensures consistency. As a result, this study suggests the following acquisition method of consistency : dealing with population mean and population ratio in the same mode, substituting the observed or experimental value of sample standard deviation for standard deviation in population in setting a confidence interval of both population mean and population ratio, and distinguishing population ratio $\hat{P}$ from its observed vale $\hat{p}$.

  • PDF

Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.