• Title/Summary/Keyword: Sun Glare

Search Result 19, Processing Time 0.027 seconds

Analysis of Highway Hazardous Area by Sun Glare Intensity Using GIS Simulation (GIS Simulation을 이용한 태양광에 의한 교통사고 위험지역 분석)

  • Kim, Ho-Yong;Baik, Ho-Jong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.4
    • /
    • pp.91-100
    • /
    • 2010
  • Existing traffic safety studies have focused on identifying the relationship among roadway crashes, highway design and incremental weather condition such as rainy/ice weather. However, it is hard to find researches that studied the effect of sun glare on traffic safety although there are abundant evidences demonstrating that fatal traffic crashes are attributed to the sun glare. Affecting drivers'vision particularly during the morning or the evening time when the sun positions close to the horizon, sun glare directly deteriorate drivers'judgmental capability. In this paper, we numerically analyze the effect of sun glare on the drivers'vision in time and space domains. Applied to the roadways around St Louis area in the United States, the GIS based simulation analysis identifies the time of day in a year and the segments of highways that are potentially influenced by the sun glare. This study evidentially confirms the fact that roadway bounded for West and East directions have longer time influenced by sun glare particularly during Spring and Fall season than other roadways. The computational result provides risky time periods of day at intersections or pedestrian crossings where the sun glare potentially endangers traffic safety, which be utilized to reduce the crashes due to the sun glare.

Analysis of Elderly Driver's Visual Function (고령 운전자의 시각적 기능 분석에 관한 연구)

  • Kim, Jung Bok;Hwang, Jeong Hee;Chu, Byoung Sun
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.505-511
    • /
    • 2018
  • Purpose : This study investigated the visual functions of drivers aged over 65 year olds and drivers aged 50~65 year olds. In addition, difference of visual functions between professional drivers and normal drivers were investigated. Methods : Forty Driver aged over 65 year olds and 67 drivers aged less than 67 year olds were participated. All participants had more than 5 years of driving experiences and had no ocular pathology. Demographic data(gender, job, age, body condition) and visual functions such as contrast sensitivity(CS), stereopsis, glare recovery time and discomfort glare index were measured. Results : Constrast sensivity under photopic condition was higher with bus driver group. In addition, difference of CS at 12cpd and 18cpd were signifcantly different between normal drivers(1.57) and bus drivers(1.70) (p<0.05). There was no significant difference for glare recovery time, despite of trend of longer recovery time with age. Discomfort glare index was significantly different that normal drivers with more than 65 year olds had 3, taxi and truck driver presented almost 5 index score (p<0.05). Conclusion : Analysis of visual function of elderly drivers, it was confirmed that their visual functions decreased with age. Therefore, visual function tests such as CS, discomfort glare index and stereopsis in addition to current available test may need to be considered for drivers aged over 65.

Low Power of Safety Oriented Sidewalk Block using Dimming Technic (디밍 기술을 이용한 안전지향 보도블록의 저 전력화)

  • Jung, Heon;Yun, Jin-Yeong;Kim, Ji-Su;Kim, Sun-Gwan;Lee, Seung-Dae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.585-590
    • /
    • 2017
  • In this paper, a low power of safety oriented sidewalk block was implemented using dimming technology using LED and illuminance sensor to prevent glare by high - intensity light source and prevent night traffic accident. The dimming system of this paper used a light bulb color with less fatigue to prevent glare and consumed 6.10Wh power. Also, it is confirmed that the power saving is about 56.9% when compared with the existing system.

Scale Model Experiments on Daylighting Performance of Topside Lighting Systems - Focused on Sun Scoop, Light Scoop and Sun Catcher Systems - (특수형 정측창 시스템의 자연채광성능에 관한 축소모형 실험 - 선 스쿠프, 라이트 스쿠프 및 선 캐처 시스템을 중심으로 -)

  • Kong, Hyo Joo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.45-52
    • /
    • 2008
  • Daylighting systems can improve the luminous quality of indoor environment and reduce the building's electric lighting energy consumption. For designing good daylighting, place the light where it is desired and avoid excessive contrasts, glare and high light levels. Sun scoop, light scoop and sun catcher systems have been used for alternative systems compared to other natural lighting systems. This study aims to evaluate daylighting performance of sun scoop, light scoop and sun catcher systems using scale model experiments. For the purpose, the 1/10 scale models of the systems were made as the same areas of glazing(10 percent of floor area) on the top of the center roof. Totally 15 measuring points of illuminance on the horizontal work plane were monitored from 09:30 to 12:30 on October 29, 2007. Agilent data logger and photometric sensors Li-cor were used. As the results, the topside lighting systems can improve the illumination uniformity than side lighting and top lighting. However, the appropriated shading system should be integrated to prevent the direct sunlight.

A Study on the Daylight Illumination Environment of a Classroom and a Glare Phenomenon on the Blackboard (교실의 주광 조명환경과 철판의 눈부심 현상에 관한 연구)

  • 임윤빈;장우진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.42-48
    • /
    • 1996
  • Glare phenomenon by sun's altitude and strong sunlight make a much visual handicap. And so, it reaches to unreadable situation although enough illumination in the fore site student of a window site and passage site. In school student seat arrange in the order of their height. So, cause the eyesight acuity according to distance is different, eyesight of backseat's student drop 1.0 and less in spite of 1.0, a learning effect reduces rather then that of the fore site student for site and Passage sitestudents. Therefore. in school, the conclusion's alteration of school structure, position's alteration and material quality's improvement of blackboard are needed, should be local lighting in blackboard. Therefore, we think that in other in improve the effect of lesson by the student, the student seats are not given by uniform disposition in the order of their height but change by a specified period.

  • PDF

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.

A study on the efficiency of sloped type Double-skin System for the Curtailment of Heating/Cooling Load (냉난방부하 절감을 위한 경사형 이중외피시스템의 성능연구)

  • An, Hyung-Jun;Kim, Young-Tag;Choi, Chang-Ho;Lee, Hyn-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.77-87
    • /
    • 2004
  • BIPV or double skin applied to the surface of the building, power and thermal load cannot both be increased. In the case of BIPV, because it is applied to the facade, incident solar energy decreases and efficiency drops off. The system in this paper complements these disadvantages and aims to decrease the heating & cooling load by transforming solar energy to electronic and thermal energy. The research in this paper is about the applicability of the clear PV attached double-skin system. And the PV electronic generation and the factors that affect the heating & cooling load such as the daily radiation, sun shading ratio, heating & cooling load, daylight luminance and glare distributions in the building are simulated.

An Evaluation of Daylight Distribution with Korean Traditional Paper and Roller Shading Systems in the Mock-up model (Mock-up 실험을 통한 전통한지와 차양장치의 주광유입 특성 평가)

  • Lee, Soon-Ji;Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.85-88
    • /
    • 2008
  • The purpose of this study is to analyze daylight distribution and light characteristics on the Ma-ji and Roller Shade fabric, and to investigate a possibility of using it as a shading system. Using a 1/2 Mock-up model, daylight distribution is analyzed with the Ma-ji and Sun-ji (Korean traditional paper) which have good efficiency and less glare. Ma-ji has the best daylight distribution, so that daylight experiment is conducted with the Ma-ji and Roller Shade fabric. In current office buildings and apartment houses, daylight characteristics of Korean traditional paper windows could be used as preliminary data to develop a window system which makes better daylight performance.

  • PDF

A Study on TRIZ Applied Design for Photovoltaic System with Reversal Tracking Reflector (역추적식 반사체를 가진 태양광 발전 시스템의TRIZ(6SC) 응용 설계)

  • Huh, Yong Jeong;Hong, Sung Do
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.3
    • /
    • pp.27-31
    • /
    • 2012
  • This paper presents a study on the design of photovoltaic system with reversal tracking reflector. The reversal tracking reflector is conceptually designed by using TRIZ. The 20 to 30% of incident rays cannot produce the current and reflected back to the glass surface because of high refractive index of solar cell which are produced from Si, GaAs. The solution of this problem has been derived using 6SC(6 steps creativity)TRIZ. The reflector which has the actuator can be trackback the sun. Reversal tracking reflector which mounted on the top of the system prevents the shadowing loss and improve the efficiency of track back function. The anti-glare reflector prevents the heat due to the concentrated reflected light rays.

A Study on High Efficiency Certification Standards of Metal-Halide Lamps and Reflectors using HID Lamps (메탈할라이드 램프 및 HID용 고조도 반사갓의 고효율에너지기자재 인증기술기준 연구)

  • Jeong, Hak-Geun;Lee, Sun-Keun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.160-162
    • /
    • 2004
  • The aim of this study is to make the technical standards for certificating a high efficiency metal-halide lamps and reflectors using the high intensity discharge lamps, to accomplish the practical energy saving effect. Metal-halide lamps are certificated by stabilzed and restarting time, lamp voltage, current, power and light output efficiency. The high illumination reflectors using HID lamps are certificated by testing reflective index, fading, the melting point, glare and install spacing factor.

  • PDF