• Title/Summary/Keyword: Sulfur gas

Search Result 572, Processing Time 0.025 seconds

A Study on the Distribution of Atmospheric Concentrations of Sulfur Compounds by GC/FPD (GC/FPD에 의한 대기 중 황화합물 농도분포에 관한 연구)

  • Yang, Sung Bong;Yu, Mee Seon;Hwang, Hee Chan
    • Analytical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.240-248
    • /
    • 2003
  • Sulfur compounds which are well-known odor-active compounds in industrial area have very low detection threshold values. Trace amounts of volatile sulfur compounds in enviroment air around several odor sources were concentrated in liquid argon bath and determined by gas chromatograph with flame photometric detector (FPD) which exhibits very good selectivity and sensitivity. 25% ${\beta}$,${\beta}$-Oxydipropionitrile on 60/80 Chromosorb W was used as adsorbent for the preconcentration of sulfur compounds in air sample and also as packing material for a packed glass column. Concentration volume of air sample was different from place to place in the range of 0.1~3.0L. Atmospheric concentrations of sulfur compounds in air of residential districts and boundaries of business establishments, and also those in the exhausted gases of emission points such as a sewage disposal plant in industrial area were measured.

Studies on the Effects of Ginseng Extract for Mucociliary Change in Mice Nasal Septum Epithelia Exposured to Sulfur Dioxide gas (인삼(人蔘) 추출액(抽出液)이 SO2 Gas에 폭로(暴露)된 새앙쥐 호흡기상피(呼吸器上皮)의 섬모(纖毛)변화에 미치는 영향(影響)에 관한 연구(硏究))

  • Kim, Moo-Kang;Cho, Sung-Whan;Ryu, Si-Yun;Lee, Geun-Jwa;Han, Kyong-O;Lee, Chul-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.31 no.3
    • /
    • pp.241-251
    • /
    • 1991
  • In order to investigate the effect of Panax ginseng extract and it's degree in mucociliary change of mice nasal septum epithelia exposured to sulfur dioxide, 96 ICR male mice were used. They were at first divided the 4th week, the 8th week or the 16th week groups according to the age after birth and 6 hour or 12 hour groups according to the $SO_2$ gas exposured hour in a day, and at control, 50mg, 100mg and 200mg injection groups according to the dosage of the freeze-drying powder of the ginseng extract which was injected into the mouse peritoneal cavities in the condition of the solution solved with physiological saline solution. Each subgroups which were divided finaly included 4 male mice. The histological tissue sections for observation were made from nasal septum, posterior nasal orfice and trachea. The results obtained by experiments were summarized as followings. 1. The loss of the nasal mucosa epithelial cilia of the mouse exponsure to the $SO_2$ gas after ginseng extract injection was apparently diminish eompare to those exposured only $SO_2$ gas without pretreatment of ginseng extract (p<0.01). 2. The inhibition effect for the loss of nasal mucocilia according to the ginseng extract dosages not found in this research (p>0.05). 3. There were differences in the loss of nasal mucosa cilia according to the $SO_2$ gas exposure time between the control group and ginseng extract pretreatment group (p<0.01). 4. According to the increase of the postnatal time, there were remarkable differences between the control group and the ginseng extract pretreatment groups in the loss of nasal mucosa cilia (p<0.01). 5. Ciliary changes of the posterior nasal orifice and trachea according to the $SO_2$ gas exposure time, mice age and ginseng dosages, were not dearly observed in this light microscopical observation.

  • PDF

A study of NOx performance for Cu-chabazite SCR catalysts by Sulfur poisoning and desulfation (Cu-Chabazite SCR Catalysts의 황 피독 및 탈황에 의한 NOx 저감 성능에 관한 연구)

  • Nam, Jeong-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.855-861
    • /
    • 2013
  • Small-pore Cu-chabazite SCR catalysts with high NOx conversion at low temperatures are of interest for marine diesel engines with exhaust temperatures in the range of 150 to $300^{\circ}C$. Unfortunately, fuels for marine diesel engines can contain a high level of sulfur of up to 1.5% by volume, which corresponds to a $SO_2$ level of 500 ppm in the exhaust gases for an engine operating with an A/F ratio of 50:1. This high level of $SO_2$ in the exhaust may have detrimental effects on the NOx performance of the Cu-chabazite SCR catalysts. In the present study, a bench-flow reactor is used to investigate the effects of sulfur poisoning on the NOx performance of Cu-chabazite SCR catalysts. The SCR catalysts were exposed to simulated diesel exhaust gas stream consisted of 500 ppm $SO_2$, 5% $CO_2$, 14% $O_2$, 5% $H_2O$ with $N_2$ as the balance gas at 150, 200, 250 and $300^{\circ}C$ for 2 hours at a GHSV of 30,000 $h^{-1}$. After sulfur poisoning the low-temperature NOx performance of the SCR catalyst is evaluated over a temperature range of 150-$300^{\circ}C$ to determine the extent of the catalyst deactivation. Desulfation is also carried out at 600 and $700^{\circ}C$ for 30 minutes to determine whether it is possible to recover the NOx performance of the sulfur-poisoned SCR Catalysts.

Separation of Sulfur Dioxide by Circulatory Porous Polymer Membrane Contactor (순환식 고분자 분리막 접촉기를 이용한 이산화황 분리)

  • Lee, Yong-Taek;Jeon, Hyun-Soo;Ahn, Hyo-Seong;Song, In-Ho;Jeong, Heon-Kyu;Lee, Hyung-Keun
    • Membrane Journal
    • /
    • v.17 no.4
    • /
    • pp.302-310
    • /
    • 2007
  • The effects of various system parameter on the absorption of sulfur dioxide into the absorbent liquid were investigated in a circulatory porous polymer membrane contactor. A feed gas and an absorbent used in the study were the gas mixture of air and $SO_2$ and the $Na_2SO_3$ aqueous solution, respectively. The separation of sulfur dioxide was measured in terms of the concentration of $Na_2SO_3$ absorbent, the concentration of sulfur dioxide, the feed flow rate, the absorbent velocity and the different membrane material. As the concentration of absorbent increased from 0.05 to 0.2 M, the removal efficiency increased from 74 to 100%. By increasing the concentration of sulfur dioxide from 700 to 2,500 ppm, the removal efficiency decreased from 100 to 75%. Also as the absorbent velocity increased from 2.5 to 15 mL/min, the removal efficiency increased from 85 to 100%. As the porosity of the membrane increased, the removal efficiency increased.

Study on Wet Scrubber for SOX/NOX Treatment in Ship Flue Gas (선박 배가스내 SOX/NOX 처리용 습식 스크러버에 대한 연구)

  • Choi, Jin-Sik;Kim, Jae-Gang;Park, Byung Hyun;Lee, Ju-Yeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.183-188
    • /
    • 2017
  • This study deals with $de-SO_X$ and $de-NO_X$ process of a wet scrubber for small size ship engines. The experiment was conducted according to the E3 mode of the $NO_X$ technical code. In order to discharge the sulfur containing flue gas, ditertiarybutyldusulfide was added to the diesel fuel to increase the sulfur content. NO gas, which occupies most of the nitrogen oxides in the exhaust gas, was oxidized into $NO_2$ and absorbed by a wet scrubber. The developed equipment of this work achieved 100% of removal efficiency for highly soluble $SO_2$ gas in an aqueous solution.

Characteristics of Acidic Gas Emissions from Combustion with Preblending of Coal and Sludge (석탄과 슬러지의 예혼합연소에 따른 산성가스 배출특성)

  • Shim, Sung-Hoon;Jeong, Sang-Hyun;Min, Hyo-Ki;Lee, Sang-Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.2
    • /
    • pp.103-108
    • /
    • 2014
  • Using dried sludge as a secondary fuel of a coal-fired power plant is proposed as an alternative option for sludge disposal. Because elemental contents of sludge are different from those of coal, different levels of acidic gas emissions are expected from the co-combustion of sludge with coal. In this study, sludge samples were obtained from 7 sewage treatment plants in Korea. Each sludge sample was combusted together with coal in a lab-scale combustor, and the concentrations of nitrogen oxides ($NO_x$), sulfur dioxide ($SO_2$), hydrogen chloride (HCl), chlorine ($Cl_2$) in the flue gas were analyzed. Compared to the combustion of coal only, $NO_x$ concentration was slightly higher in the flue gas from the co-combustion of coal and sludge. $SO_2$ emission increased with the combustion of sludge due to the higher content of sulfur in sludge than in coal. For most of the tested samples, the concentrations of HCl and $Cl_2$ were varied depending on the chlorine content in the sludge sample.

Analysis of SF6, N2 Pressure Characteristic of Spark Gap According to Simulation (시뮬레이션을 통한 스파크갭의 SF6, N2 압력 특성 분석)

  • Choi, Sun-Ho;Lee, Tae-Woo;Bang, Jeong-Ju;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.3
    • /
    • pp.172-177
    • /
    • 2014
  • Industrial, medical, environment and agriculture application of pulse power technology have been developing rapidly in many field. In order to make use in the form of pulses is applied to the pulse forming technique. At this time, spark gap is generally used for the pulse forming. Spark gap may be possible to simulate the shape of the electrode, to know the uniform or non-uniform electric field of the electrode structure. Further, it can be determined using Paschen's law applied pressure of the insulating gas in accordance with the voltage which is created using the value of the electric field. In this paper, we tried to found using a formula and the simulation process to determine the pressure. The value of the electric field is different according to the shape of the electrode. So, the range of pressure applied also varies. In order to withstand the 100 kV with a gap of 5 mm, the nitrogen gas must be applied to about 7 bar in the electrode structure. On the other hand, in the same conditions, Sulfur hexafluoride gas must be applied to about 2 bar. Consequently, the Sulfur hexafluoride gas has a higher insulation properties than nitrogen gas may be applied to low pressure at the same conditions.

A study on effect of additives upon A.C. partial discharge in insulating oil (절연유의 교류부분방전에 미치는 첨가물의 영향에 관한 연구)

  • 국상훈
    • 전기의세계
    • /
    • v.29 no.8
    • /
    • pp.532-537
    • /
    • 1980
  • Effect of Argon and Sulfur hexafloride in the transformer oil are experimented under non-uniform A.C. electric field. The result has shown that the corona frequency and corona charge quantity in liquid dielectrics were varied with gas condition in the oil and affected by the additives. SF$_{6}$ that has the effects of pressure and electrical negative characteristic is the most effective. The corona is considered to be the breakdown of bubble produced by gas contained in the oil or by dissociated ion of the oil molecules.s.

  • PDF

On the Short Term Air Pollution Dispersion Model for the Single Souce -Diffusion Experiment With Tracer Gas- (單一 排出源大氣汚染 短期모델에 관한 硏究 -Tracer Gas에 의한 擴散實驗-)

  • 李鍾範;姜寅求
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.84-96
    • /
    • 1989
  • To evaluate the short term air pollution dispersion model, the diffusion experiment was conducted on the flat terrain near Chuncheon. Sulfur hexafluoride $(SF_6)$ gas was used to determine the horizontal spread of plume $(\sigmay)$ for calculated by CRSTER model. Results show that CRSTER model underestimates $\sigma$y because averaging time adjustment is not applied to calculate the $\sigma$y. The scheme that can estimate the atmospheric stability more accurate than Turner method, was presented.

  • PDF

Studies on the Deodorization in the Nightsoil Treatment Plant with liquid Phase Catalytic Oxidation Method by Utilization of Fe-EDTA (Fe-EDTA계 액상촉매 산화법에 의한 분뇨처리장 악취제거에 관한 연구)

  • 이인화
    • Journal of Environmental Science International
    • /
    • v.1 no.2
    • /
    • pp.105.1-113
    • /
    • 1992
  • The present study was performed to develop the removal system of the offensive gases, including hydrogen sulfide of acid gas, ammonia or amice of base gas, from the nightsoil treatment plant. In order to remove the offensive gases, the Fe-EDTA system liquid phase catalytic oxidation method with the bubble lift column reactor was employed. From the results obtained, it was confirmed that the offensive gases can be deodorized simultaneously and also hydrogen sulfide of acid gas, ammonia of base gas completely removed at pH 6.45. In addition, as input gases feed rate the efficiency of acid gas did not change but the efficiency of base gases decreased to approximately 90 % at pH 6, 0. From the result of particle size analyzer, it was found that the particle sizes including sulfur and other impurites grew up to $21{\mu}m$ over 72hour reaction time.

  • PDF