• Title/Summary/Keyword: Sulfur Particles

Search Result 95, Processing Time 0.021 seconds

Investigation of Plume Opacity Induced by the Combustion of Orimulsion (오리멀젼 연소로 인한 가시백연의 원인 규명)

  • Kim, Young-Hun;Kim, Jong-Ho;Joo, Ji-Bong;Lee, Jeong-Jin;Kim, Jin-Soo;Kwak, Byung-Kyu;Jeong, Jin-Heun;Park, Soong-Keun;Yi, Jong-Heop
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.297-303
    • /
    • 2007
  • Orimulsion, a bitumen-in-water emulsified fuel, has been used throughout the world as a substitute fuel for heavy oil and coal. Orimulsion has relatively high levels of sulfur, nickel, and vanadium, compared to other fuel oils and coals, and has been the subject of much debate regarding the environmental impacts. In Korea, Y power plant has operated boilers with Orimulsion as a fuel, and they has some drawbacks during the plant operation, such as plume opacity. In this study, we investigated the cause of formation mechanism and factors for the plume opacity by investigating the operation data, and measuring the particle size distribution at EP(Electrostatic Precipitator), FGD(Fuel Gas Desulfurization) and TMS(Telecommunications Management System) units. Resulting data showed the primary particles below 1 ${\mu}m$ formed were regrown by the recombination of $SO_3$ in wet-limestone FGD process, and thus the secondary particles are induced to cause the plume opacity.

Size Distributions of Trace Elements in Airborn Particulates Collected using Drum impactor at Gosan, Jeju Island : Measurements in Springtime 2002 (DRUM impactor를 이용한 대기 입자상 물질 중 원소성분의 입경분포 특성 : 제주도 고산지역의 2002년 봄철 (3.29-5.30) 측정 연구)

  • 한진석;문광주;류성윤;안준영;공부주;홍유덕;김영준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.555-569
    • /
    • 2004
  • Size -segregated measurements of aerosol composition using 8-stage DRUM impactor are used to determine the transport of natural and anthropogenic aerosols at Gosan site from 29 March to 30 May in 2002. Separation of ambient aerosols by DRUM impactor offers many Advantages over other standard filtration techniques. Some of the most important advantages are the ability to segregate into details by particle tire, to better preserve chemical integrity since the air stream doesn't pars through the deposit, to collect samples as a function of time, and to have a wide variety of impaction surfaces available to match analytical needs. Although the transport of Yellow sand is a well-known phenomenon in springtime, the result of measurement shows that not only soil dust but also anthropogenic aerosols, including sulfur, enriched trace metals such as Pb, Ni, Zn. Cu, Cr, As, Se, Br, are transported to Gosan in springtime. This study combines the size- and time-resolved aerosol composition measurements with isentropic, backward air-mass trajectories in order to identify some potential source regions of anthropogenic aerosols. As a result, during the NYS period, the average concentration of PM$_{10}$ was 46$\mu\textrm{g}$/㎥, Si, Al. S, Fe, Cl, K, Ca were higher than 1,000 ng/㎥ and Ti was about 100 ng/㎥. The concentrations of Zn, Mn, Cu. Pb, Br, Rb, V, Cr, Ni. At, Se ranged between 1 and 70 ng/㎥. More than 50% typical soil elements, tuck as Al, Si, Fe, Cd. Ti, Cr, Cu, Br. were distributed in a coarse particle range(5.0-12${\mu}{\textrm}{m}$). In other hand, anthropogenic pollutants, luck as S, N, Vi, were mainly distributed in a fine particle range (0.09-0.56${\mu}{\textrm}{m}$). During the YS period, PM$_{10}$ increased about 8 times than NYS period, and main soil elements, such as Al, Si, S, K, V, Mn, Fe also doubled in coarse particle range (1.15-12${\mu}{\textrm}{m}$). But Zn, As, Pb, Cu and Se, which distributed in the time aerosols (0.09-0.56${\mu}{\textrm}{m}$), were on the same level with or decreased than NYS period. Finally. except the YS Period, coarse particles (2.5-12${\mu}{\textrm}{m}$) are inferred to be influenced by soil, coal combustion, waste incineration, ferrous and nonferrous sources through similar pathways with Yellow Sand. But fine particles have different sources, such as coal combustion, gasoline vehicle, biomass burning, oil or coal combustion, nonferrous and ferrous metal sources, which are transported from China, Korea peninsula and local sources.ces.

Deposition Process of Sulfate and Elemental Carbon in Japanese and Thai Forests

  • Sase, Hiroyuki;Matsuda, Kazuhide;Visaratana, Thiti;Garivait, Hathairatana;Yamashita, Naoyuki;Kietvuttinon, Bopit;Hongthong, Bundit;Luangjame, Jesada;Khummongkol, Pojanie;Shindo, Junko;Endo, Tomomi;Sato, Keiichi;Uchiyama, Shigeki;Miyazawa, Masamitsu;Nakata, Makoto;Lenggoro, I. Wuled
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.4
    • /
    • pp.246-258
    • /
    • 2012
  • Particulate matter deposited on leaf surfaces may cause erosion/abrasion of epicuticular wax and the malfunction of stomata. However, the deposition processes of particulate matter, such as elemental carbon (EC), has not been studied sufficiently in Asian forest ecosystems. Deposition processes for particulate ${SO_4}^{2-}$ and EC were studied in a Japanese cedar forest in Kajikawa, Niigata Prefecture, Japan, and in a dry evergreen forest and a dry deciduous forest in Sakaerat, Nakhon Ratchasima province, Thailand. The ${SO_4}^{2-}$ fluxes attributed to rainfall outside the forest canopy (RF), throughfall (TF), and stemflow (SF) showed distinct seasonalities at both sites, increasing from November to February at the Kajikawa site and in March/April at the Sakaerat site. Seasonal west/northwest winds in winter may transport sulfur compounds across the Sea of Japan to the Kajikawa site. At the Sakaerat site, pollutants suspended in the air or dry deposits from the dry season might have been washed away by the first precipitations of the wet season. The EC fluxes from RF and TF showed similar variations by season at the Kajikawa site, while the flux from TF was frequently lower than that from RF at the Sakaerat site. Particulate matter strongly adsorbed onto leaf surfaces is not washed away by rainfall and contributes to the EC flux. At the Kajikawa site, Japanese cedar leaf surfaces accumulated the highest levels of particulate matter and could not be neglected when calculating the total flux. When such leaf-surface particles were considered, the contribution of dry deposition to the total EC flux was estimated to be 67%, 77%, and 82% at the Kajikawa site, and at the evergreen and deciduous forests of the Sakaerat site, respectively. Leaf-surface particles must be included when evaluating the dry and total fluxes of particulate matter, in particular for water-insoluble constituents such as EC.

Study on the Assessment of Air Quality Before and After Action Plan of Atmospheric Environment Improvement Establish at Gimhae, Gyeongnam Province (경남 김해지역의 대기환경개선 실천계획 수립 전후의 대기질 평가에 관한 연구)

  • Park, Jong-Kil;Jung, Woo-Sik;Kim, Seok-Cheol;Kim, Eun-Byul
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1111-1120
    • /
    • 2008
  • In order to study the degree of improved air quality as an outcome of the action plan of Atmospheric Environment Improvement in Gimhae, Gyeongnam Province, we investigated the status and trends of air pollutant before and after the plan. Nitrogen dioxide and ozone, both classified as hazardous substances, were closely monitored with particular attention. The level of sulfur dioxide, nitrogen dioxide, fine particles and ozone (but for carbon monoxide) was decreased after the plan was implemented. The number of days on which ozone exceeded the National Ambient Air Quality Standard has decreased, but the level was still often exceeded. The level of nitrogen dioxide did not surpass until the 2006 standard, but when the revised 2007 standard was implemented, it exceeded 80% of some standards. The yearly level of ozone has decreased since the plan was introduced. The concentration of nitrogen dioxide, however, has reduced in high order area while increased in low order area.

Temporal and Spatial Variation and Characteristics of Ambient Air Quality in Urban Areas in Gyeonggi Province (경기도 도시지역 환경대기질의 시공간적 추이와 특성)

  • Kim, Jong-Chan
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.3
    • /
    • pp.269-276
    • /
    • 2012
  • Objectives: The purpose of this study was to provide policy directions for air pollution reduction by analyzing the variation in the characteristics of air contaminants around the Gyeonggi Province area. Methods: The data used in the study was obtained from air quality monitoring stations operated by the Gyeonggi Provincial Government. The target area was the air quality management area of the Gyeonggi Province region. Results: The concentration of $PM_{10}$ (particles measuring $10{\mu}m$ or less) in 2009 was $60{\mu}g/m^3$, which has been reduced by about 2.7% per year after improvement countermeasures were emplaced. The air pollution control policy was especially more effective for coarse particulate matter (CPM, $PM_{10-2.5}$). The improvement of $NO_2$ pollution was generally very low, especially in cities which had considerable automobile traffic. The concentration of $SO_2$ pollution was rapidly improved in industrial areas, but did not show any difference for multiple and general cities. The predicted concentration of $PM_{10}$ for 2014 based on the trend over 2001-2009 was $53.4{\mu}g/m^3$, which fails to meet the target concentration of $40{\mu}g/m^3$. The predicted concentration of $NO_2$ shows a very low probability of achieving the target concentration of 22 ppb, and thus the current improvement of air quality has proven unsatisfactory. Conclusion: Air pollution control policy should be enforced according to regional pollution characteristics in order to obtain maximum effectiveness in improvement.

Characteristics of Hydrogen Iodide Decomposition using Alumina-Supported Ni Based Catalyst (Ni 기반 촉매를 이용한 HI 분해 반응 특성)

  • KIM, JI HYE;PARK, CHU SIK;KIM, CHANG HEE;KANG, KYOUNG SOO;JEONG, SEONG UK;CHO, WON CHUL;KIM, YOUNG HO;BAE, KI KWANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.6
    • /
    • pp.507-515
    • /
    • 2015
  • HI decomposition reaction requires a catalyst for the efficient production of hydrogen as a key reaction for hydrogen production in sulfur-iodine thermochemical water-splitting (SI) cycle. As a catalyst used in the reaction, the performance of platinum catalyst is excellent. While, the platinum catalyst is not economical. Therefore, studies of a nickel catalyst that could replace platinum have been carried out. In this study, the characteristics of the catalytic HI decomposition on the amount of loaded nickel (Ni = 0.1, 0.5, 1, 3, 5, 10 wt%) were investigated. As the supported Ni amount increased up to 3 wt%, HI decomposition was found to increase in linear proportion. However, the conversion of $Ni/Al_2O_3$ catalyst loaded above 3 wt% was not linear. It was thought that the different HI decomposition characteristics was caused in the size and metal dispersion of Ni particles of catalyst. The physical property of catalyst before and after HI decomposition reaction was characterized by BET, chemisorption, XRD and SEM analysis.

Air Pollutant Variations Observed at Deokjeok Island in the Yellow Sea During April 1999 to June 2000 (1999년 4월부터 2000년 6월까지 황해 덕적도에서 관찰된 대기오염물질 변화 특성)

  • 김영성;이승복;김진영;배귀남;문길주;원재광;윤순창
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.4
    • /
    • pp.347-361
    • /
    • 2003
  • Sulfur dioxide (SO$_2$), ozone, total suspended particulates (TSP) and PM$_{2.5}$ were measured at Deokjeok Island in the Yellow Sea during April 1999 to June 2000. Although the emission amount of air pollutants is quite low in this small island of 36 km$^2$ with 1.4 thousand inhabitants, there are pollutant sources such as an oil -firing power plant and a wharf for ferryboat. The island is also influenced from the emissions from the greater Seoul area in the east and from China in the west. In order to characterize the pollutant variations due to interactions between transport and local emissions. the correlation between variations of SO$_2$ and ozone was investigated. Mass and ion concentrations of TSP and PM$_{2.5}$ were examined on selected episode days of positive and negative correlations between the two gaseous species in spring and winter. The effects of transport were pronounced on the days of positive correlation in spring with higher concentrations of ozone and PM$_{2.5}$. TSP concentrations were also high on these days because of high wind speeds. On the days of negative correlation in spring, frequent fog associated with low wind speeds facilitated SO$_2$ oxidation and increased sulfate accompanied with decrease in nitrate in PM$_{2.5}$ and chloride in TSP. This latter phenomena was noticeable since it showed that chemical composition of fine particles could be significantly altered not only during the transport but also by local environment.ronment.

Thoracic Actinomycosis - A Case Report - (흉부 방선균증-1례 보고-)

  • 박찬범;최시영;조덕곤;문석환;조규도;조건현;왕영필;이선희
    • Journal of Chest Surgery
    • /
    • v.35 no.12
    • /
    • pp.914-916
    • /
    • 2002
  • Actinomycosis of the lung is a chronic, suppurative granulomatous infection which is caused by Actinomyces israelii. It is believed to enter the thorax by way of the bronchial tree, by aspiration of contaminated aerosol particles in the upper digestive tract. Symptoms of chronic cough, sputum, hemoptysis, low grade fever, chest pain, and weight loss are common. Chest X-ray shows mass like lesion, pulmonary infiltration, abscess, and tuberculosis like lesion, which makes differential diagnosis from lung cancer very difficult. Surgical intervention is needed for the diagnosis and treatment, and diagnosis of actinomycosis is achieved when histologic examination reveals sulfur granules containing filamentous organisms. Penicillin is the drug of choice. Two or three months of penicillin treatment is recommended to treat the oropharyngeal or dental abscess to avoid recurrences. We present a case of actinomycosis which is suspected to malignant with review of literatures.

A Study on Particulate Matter Formed from Plasma Decomposition of SF6 (SF6의 플라즈마 분해로부터 생성된 입자상 물질에 관한 연구)

  • Kim, Seon-Woo;Kim, Jong-Bum;Kim, Jae-Hwan;Kim, Rae-Hyeong;Ryu, Jae-Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.4
    • /
    • pp.326-332
    • /
    • 2017
  • $SF_6$ (sulfur hexafluoride) gas has an extremely high global warming potential (GWP). Therefore, there has been an effort to reduce of $SF_6$ its emission into atmosphere. In this study, $SF_6$ was injected into the plasma reactor directly, decomposed particulate matter of $SF_6$ was analyzed. Destruction and removal efficiency (DRE) of $SF_6$ were tested with varying degrees of plasma power and initial concentrations of $SF_6$ (1,000 ppm). This study is conducted with plasma power which are 4.4 kW, 5.5 kW, 6.0 kW, 6.6 kW, 7.6 kW, 8.1 kW and 9.1 kW. It was confirmed through experiment that the decomposition efficiency of $SF_6$ is 100% at 7.6 kW of the plasma power. In addition, the particulate matter is formed as minute particles of which size is $1{\mu}m$ and the main component of particulate matter is identified as $AlF_3$.

Reduction Effect of Airborne Pollutants in Pig Building by Air Cleaner Operated with Plasma Ion (플라즈마 이온 방식의 공기정화기를 이용한 돈사내 공기오염물질 저감 효과)

  • Kim, Yoon-Shin;Kim, Ki-Youn;Cho, Man-Su;Ko, Moon-Suk;Ko, Han-Jong;Jung, Jin-Won;Oh, Mi-Seok;Youn, Baek;Kim, Jung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.306-312
    • /
    • 2010
  • This field study was performed to evaluate the efficiency of a plasma ion-operated air cleaner in temporal reduction of airborne pollutants emitted from a pig housing facility. In the case of gaseous pollutants, the plasma ion air cleaner was not effective in reducing levels of ammonia, hydrogen sulfide, nitrogen dioxide, or sulfur dioxide (p>0.05). In the case of particulate pollutants, however, the air cleaner was effective in reducing levels of particulate matter ($PM_{2.5}$ and $PM_1$) by 79(${\pm}6.1$) and 78(${\pm}3.0$)%, respectively. Unlike the case of these fine particle fractions, the reduction of total suspended particles (TSP) and $PM_{10}$ following treatment was almost negligible. In the case of biological pollutants, the mean reduction efficiencies for airborne bacteria and fungi were relatively low at 22(${\pm}6.6$) and 25(${\pm}8.7$)%, respectively. Taken together, these results indicate that in terms of air pollutants released from this pig housing facility, the plasma ion air cleaner was primarily effective in reducing levels of $PM_{2.5}$ and $PM_1$.