• 제목/요약/키워드: Suction cup

검색결과 15건 처리시간 0.03초

영구자석을 이용한 새로운 Suction Mechanism (New Suction Mechanism Using Permanent Magnet)

  • 서성근;이승희;박종현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.962-966
    • /
    • 2004
  • Suction transfer system with air suctioning is widely used and continuously developed in production automation. Air suctioning has some drawbacks in use. To generate vacuum in the suction cup with air suctioning, complex of mechanical component like as air compressor, air tube, air value is need, and it needs continuous air supply. And if the failure of the suction in a cup in the multi-suction cup system which is generally used occurs then the suctions of all of the cup will be fail. To overcome these drawbacks, new suction mechanism which uses permanent magnet for the movement of the suction cup is proposed. The proposed mechanism activates each suction cup separately, so the air leakage of a cup is not critical. The proposed suction system wasdesigned and fabricated in real world. With some experiments, the usability and performance of the suction mechanism was proved. The strong points of the proposed suction mechanism are simple structure, high energy efficiency, and discrete energy supply.

  • PDF

영구자석을 이용한 새로운 Suction Mechanism (New Suction Mechanism Using Permanent Magnet)

  • 서성근;이승희;박종현;장태사
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1645-1652
    • /
    • 2005
  • Pick-and-place systems using suction cups have been being widely used and continuously developed in production automation. There are, however, some drawbacks in constructing such systems. One of them is that it generates high level noise due to air compressors. And the system must have complex constitutions of mechanical component such as air compressors, air tubes, air valves, etc. Moreover, it needs continuous air supply to maintain vacuum in suction cups. If there is a failure in any suction cup, the total suction system may fail owing to air leakage. To overcome these drawbacks, we propose PMS (Permanent Magnet Suction) mechanism which has permanent magnets for vacuuming suction cups with no air compressor. The basic concept of PMS mechanism is to rotate permanent magnets with fixed angle. Simple rotation of permanent magnets changes the direction of the magnetic force applied at the suction cups. Since each suction cup has no direct connection with any of the others, the air leakage at one suction cup is not critical. The proposed suction mechanism was designed and fabricated. With some experiments, the feasibility and performance of the PMS mechanism was shown. The strong points of the PMS mechanism are in its simple structure, generating low noise, high energy efficiency, and no need of continuous energy supply.

Pressure Changes During Layer Cupping in a Skin Model

  • Shim, Dong Wook;An, Soo Kwang;Lee, Ha Lim;Lee, Jae Yong;Lee, Byung Ryul;Yang, Gi Young
    • Journal of Acupuncture Research
    • /
    • 제38권2호
    • /
    • pp.159-164
    • /
    • 2021
  • Background: Cupping is widely used in Korean medicine, but there is a risk of bacterial infection if the suction pump (used for inducing negative pressure) and the patients' skin are not separated. This study aimed to investigate the effect of layer cupping by comparing the pressure changes between layer cupping and conventional cupping. Methods: To evaluate pressure changes the study was designed with 3 types of conditions applied to a skin model: (1) a Dongbang cup with a manual or motor suction pump (conventional cupping); (2) layer cupping with 2 Dongbang cups; and (3) layer cupping with a cup made by 3D printing and a Dongbang cup. Results: When a manual suction pump was used (conventional cupping), the pressure did not decrease steadily, and in 1 section there was an increase in pressure. When layer cupping was used, the pressure in the lower cup (which would be directly applied to the patient's skin), decreased steadily. Conclusion: In the pressure change graph for layer cupping in this skin model, the pressure in the lower cup (which would be placed on the patient's skin) steadily decreased, and reached equilibrium. Therefore, the layer cupping model may help to reduce the risks of bacterial infection.

Elevation of Depressed Skull Fracture with a Cup of Breast Pump and a Suction Generator : A Case Report in Technical Aspects

  • Kim, Young-Jin;Lee, Sang-Koo;Cho, Maeng-Ki;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권4호
    • /
    • pp.346-348
    • /
    • 2007
  • Surgical elevation of the depressed bone is known to be the conventional treatment usually recommended for a simple depressed skull fracture in the adult or pediatric age. The authors introduce, however, a case of depressed skull fracture in an infant which was elevated by means of a cup of breast pump and a suction generator without surgical elevation. In our case, without surgery, a 'cup-shaped' depressed skull fracture in an infant was safely elevated with no neurological signs. This method is considered a simple, effective, safe, and alternative procedure in an infant with simple depressed skull fracture.

태양광발전시설 무인 유지보수 로봇 개발 (Development of Unmanned Cleaning Robot for Photovoltaic Panels)

  • 이현규;이상순
    • 반도체디스플레이기술학회지
    • /
    • 제18권3호
    • /
    • pp.144-149
    • /
    • 2019
  • This paper describes the results of a study on the unmanned maintenance robot that simultaneously performs the cleaning and inspection of the photovoltaic panels. The robot has a special adsorptive device, an infrared sensor, a vacuum level sensor and a camera. The robot uses two SSC (Sliding Suction Cup) adsorptive devices to move up and down the slope. First, the forces generated when the robot moves up the slope are mechanically analyzed, and the required design and control of the adsorption system are suggested. The robot was designed and manufactured to operate stably by using the presented results. Next, the normal force between the panel and the wheel was measured to confirm that the robot was manufactured and operated as intended, and the robot motion was tested on the inclined panel. It has been proven that robots are well designed and built to clean and inspect sloped panels.

대평판 이송을 위한 비접촉 헤드 설계 (Design of Non-Contact Pick-Up Head for Carrying Large Flat Sheets)

  • 김준현;김영글;안성욱;김용성
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.937-944
    • /
    • 2013
  • This paper describes an improved model that can be used for configuring a non-contact pneumatic head to handle a large sheet of glass. The cylindrical head model is of a large size (70 mm). It operates on vortex flow, which can simultaneously generate suction and repulsion over the flat object's surface. The head allows for the minimal non-contact lifting of objects weighing over 3N by using reference conditions (working pressure and head dimensions). Additionally, a functional flow-guide is applied for inducing a developing tangential vortex flow to increase suction and repulsion to the reference head. The cylindrical flow-guide is associated with relatively low tangential velocity. The improved model generates greater lifting force than the reference model, as verified experimentally.

An Experimental Study on the Relationship Between Temperature and Pressure Inside the Cup During Cupping Procedures

  • Lee, Ha Lim;An, Soo Kwang;Lee, Jae Yong;Shim, Dong Wook;Lee, Byung Ryul;Yang, Gi Young
    • Journal of Acupuncture Research
    • /
    • 제38권1호
    • /
    • pp.41-46
    • /
    • 2021
  • Background: Pressure changes related to temperature variation during cupping may lead to dropout. This study aimed to investigate pressure changes related to temperature variations in the cup during the cupping procedure. Methods: Changes in temperature and pressure were measured for 15 minutes after the procedure was performed using the alcohol rub method with glass cups and with the addition of infrared irradiation. Changes in temperature and pressure were also measured for 15 minutes after pumping 3 times using the valve suction method, and with the addition of infrared irradiation. Results: In a comparison between the alcohol rub method with glass cups and with the addition of infrared irradiation, the negative pressure increased over time in the absence of infrared irradiation, whereas it decreased when performed with infrared irradiation p = 0.094. However, in a comparison between pumping 3 times using the valve suction method, and with the addition of infrared irradiation, the negative pressure decreased in both cases, but this was more significant with infrared irradiation p = 0.172. There was a significantly higher temperature in the glass cups (p = 0.004) and the valve cups (p = 0.001) exposed to infrared radiation, compared with no infrared irradiation. Conclusion: The reduction in negative pressure inside the cups exposed to infrared radiation was greater than without infrared irradiation. Temperature increases inside the cup can lead to the risk of dropout.

Computed Radiography 영상에서 Parameter에 의한 Artifact 원인과 해결방안 (Cause and Solution of an Artifact Generation by Parameter in Computed Radiography System)

  • 동경래;최준구;홍성일
    • 한국콘텐츠학회논문지
    • /
    • 제9권5호
    • /
    • pp.145-155
    • /
    • 2009
  • CR방식의 도입으로 인해 많은 장점을 가지게 되었으나 기존의 Film/Screen방식에서 발생되지 않았던 Artifact가 새롭게 발생하였다. 따라서 본 논문에서는 광주에 위치한 일개 종합병원에서 획득한 CR 영상 중 Artifact가 발생한 경우를 3가지로 나누어 측정하였다. 시간 지연과 농도변화에 의한 Artifact는 시간이 경과할수록 자연방사선에 의한 영향으로 1일보다 5일후에 67%의 농도가 증가 되었으며 잠상퇴행에 의한 Artifact는 즉시보다 10시간 후의 빛의 방출도가 33%감소하여 시판이 경과할수록 영상의 질이 저하되었다. 술자에 의한 Artifact는 Collimation에 의한 Artifact가 53%, 기기에 의한 Artifact는 Guiding plate, Suction cup으로 인한 Artifact가 65%로 가장 많이 발생되는 것으로 나타났다. 따라서 Artifact에 대한 정확한 인식을 정기적인 점검을 통해 해결방안을 모색한다면 영상의 질 및 진료의 만족도를 높여 갈 수 있을 것이다.